Tender Value
Refer Docs
EMD Value
₹97,800
Closing Date
21 Sept 2022, 6:00 pmClosed
GE (AF) SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE REPAIR/MAINT OF INFRASTRUCTURE EXTERNAL WATER SUPPLY BY AUTOMATION SYSTEM THROUGH OEM INCLUDING CERTAIN ALLIED WORKS AT AF STN SULUR
2022_MES_542661_1
8504/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE (AF) SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) SULUR
₹97,800
Yes
20 Oct 2022
2 Aug 2022
22 Sept 2022
2 Aug 2022
21 Sept 2022
30 Aug 2022
2 Aug 2022 - 10 Aug 2022
Amount
SCHEDULE A BOQ
Supply and fixing in repairs PLC (Programmable Logic Controller) having CPU speed 0.3 micro second for Bool inspection, 0.6 micro second for word instruction with Input power 9.6W complete all as specified and directed. Make :Mitsubishi/SIEMENS/ or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs I/O module for Programmable Logic Controller having operation voltage range 10.2 to 28.8 V DC, related output voltage 12/ 24 V DC, all modules shall possess a status LED per output complete all as specified and directed. Make :Mitsubishi, Siemens or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs HMI for Programmable Logic Controller having port type 1 x ethernet, 1 x RS 232, 1 x RS422/ 485, 1 x USB port and compatible for supply voltage 24 V DC all as specified and directed. Make :Mitsubishi, Siemens or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply only Relay 24V DC with base and having Contact configuration 4 PDT, coil voltage 24 V DC, current 6A product range RV serious, relay mounting socket coil type - Latching single coil approval standards LE, LSA, TUV, UL complete all as specified and directed. Make : IDEC/Leone or existing make/brand of defective components/ spare parts or any reputed suitable make as approved GE.
Supply and fixing in repairs water Level Controller PCB-10 Level suitable for power supply (12-14 V DC) or 16-18 V DC/ 100 MA relay out put : 240V/ 3 A Max complete all as specified and directed. Make: Splash/ICS or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Pressure switch 0-10 Kg/sqcm having maximum test pressure : 22 bar, maximum working pressure : 17 bar, pressure connection type: G-1/4 male and electric connection size 6-14mm complete all as specified and directed. Make : Danfoss/Indfoss/Rapid Controls or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE
Supply and fixing in repairs Coil for Solenoid Valve 25mm suitable for standard 24-110-220-230V/ 50-60 Hz AC, Voltage tolerance : +10% - 5% for DC, +10% - 15% for AC complete all as specified and as directed. Make: JOHNSON CONTROLS/ AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Coil for Solenoid Valve 10 mm suitable for standard 24-110-220-230V/ 50-60 Hz AC, Voltage tolerance : +10% - 5% for DC, +10% - 15% for AC all as specified and asdirected. Make: JOHNSON CONTROLS/ AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing in repairs Cast Aluminium Top cover for Actuator suitable for 50/80/100mm dia of Butterfly Valve complete all as specified and directed
Supply and fixing in repairs Capacitor for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm bore of Motorized Butterfly Valve complete all as specified and directed
Supply and fixing in repairs SMPS suitable for input 230 V/AC, Output 24V DC, 5A out put current output power 120W, line regulation : 0.5% (full load), load regulation : 1% (230 V AC I/P), operating temparature (°C) : -20 to +70 complete all as specified and directed. Make: NHP/ TELEMEACHNIQUE or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs single phase Preventor suitable for supply voltage : 100 - 120/ 220 -240/ 380 - 440 V AC + 20% complete all as specified and directed. Make - Minilec or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Comprehensive maintenance as required for all modernised infrastructure as described below under GE(AF) Sulur as follows:- (a) Servicing and repair/ maint/ replacement of defective components /spare parts of PLC based control panels including all accessories modem, antenna etc. installed at various pump houses, OHTs and Master control station for monitoring of water supply.
(b) Repair/maintenance by disconnecting connection for cleaning, lubricating, greasing for wear and tear complete servicing, refixing, lathing installing and commissioning of all motorised, solenoid valves, Pressure Switches, Ultrasonic and magnetic Level sensors etc complete as directed by Engineer-iniCharge.
(c) Servicing and maintenance /repair of defective components of PLC based control panels including all accessories, modem, antenna etc. installed at various locations for the monitoring of street light circuits.
The scope of work also covers the following : (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of items covered under this AMC)
(ii) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of items covered under this AMC)
Note for item No 15 to 19 :- (a) The comprehenive maint/ repair shall be carried out through the authorised representative of the OEM only.
(b) Cost of labour element towards removing of unserviceable/ defective spare part and re-fixing the serviceable spare part shall be deemed to be included in unit quoted rate. Supply only spare part shall be measured and paid seperately under the relevent item.
(c) Any other spare parts which have not covered in the relevent item given here in below but are required to make system in functional condition deemed to be included in the unit quoted rate.
(d) The unit quoted rate shall be inclusive of One Engineer/ Supervisor per day, Two Technician per day having minimum 05 years experience in SCADA system. Documentary proof of experience of engineer/ technician shall be produced to Enginner-in-Charge before commencement of work. If extra manpower is required for smooth functioning of above mentioned system, rate for same deemed to be inclusive in unit quoted rate.
(e) Service Engineer of OEM or authorised service centre shall visit at least once in every month and during major break down or as and when required for the inspection, servicing, repair, rectification of problem and submission of report.
(f) All the charges for the communications, i.e. 01 Nos broad band connection with static IP at Kalpa Pump House and GPRS enabled data cards used in all PLC based panel related to this scope of work deemed to be inclusive in the quoted unit rate.
(g) SCADA reports related to above mentioned system shall be mailed to Engineer-in-Charge/ concerned JE on weekly basis.
(h) All complaints related to unservicability/ break down of the system shall be attended with in 8 hours, if failed to rectify the system within the stipulated time, a penalty @ Rs. 500 per day will be deducted from the dues of the contractor.
(j) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(k) The decision of the Accepting Officer in this regard shall be final and binding.
(l) The servicing of Motorised valve, PLC base control Panels, communication Panels, shall be done by authorized representative of the Manufacturer only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him .
(m) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer (OEM) of PLC based Panels only. The programmer shall submit a letter from the manufacturer as proof of his being an authorized representative of the manufacturer. The programmer shall also submit a signed report on original letter head of the manufacturer (OEM) that servicing has been carried out by him.
(n) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer of PLC based Panels only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him.
Supply and fixing in repairs LED Indicator Colour/Red complete all as speicifed and directected. Make TELEMEACHNIQUE/ESBEE/TEKNIC or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs key pad base HMI having 128 x 64 pixel display, RS 232 or RS 485 USB port TR1 PLC host link protocols for Programmable Logic Controller complete all as specified and directed. Make :Mitsubishi, Siemens or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Relay 230 V AC with base and having contact configuration 4 PDT, coil voltage 24 VDC, current 6A product range RV serious, relay mounting socket coil type - Latching single coil approval standards LE, LSA, TUV, UL complete all as specified and directed. Make : IDEC/Leone or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs solenoid Valve 10mm 230V AC suitable for maximum operating pressure (MOP) upto 25 bar with 12W coil Complete all as specified and directed. Make: JOHNSON CONTROLS/ AVCON/ DANFOSS or existing make/ brand of defective components/spare parts or any reputed suitable make as approved by GE
Supply and fixing in repairs Magnetic Level switch having contact rating : 10W, switching voltage 24 VDC, switching current : 0.5A, temparature rating - 10/ +85°C complete all as specified and directed. Make: MAHALAXMI/ CRYSTAL or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Pressure gauge 0-100 Pascal having measuring range : 0-10 Kg/cm², dial size : 100mm connection : 3/8" BSP (M), mounting : Bottom, Dial size : 4 inch, material : casing :MS, internal : brass complete all as specified and directed. Make Fiebag/Manometer or existing make/brand of defective components/spare parts.
Supply and fixing in repairs Butterfly valve for 50 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AUDCO or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Butterfly valve for 100 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AUDCO or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Resistor for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm bore motorized Butterfly Valve complete all as specified and directed
Supply and fixing in repairs Limit switch with degree of protection IP 67, operating speed 1mm/s to 5m/s for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm dia of motorized Butterfly Valve complete all as specified and directed.
Comprehensive maintenance as required for all modernised infrastructure as described below under GE(AF) Sulur as follows: :- (a) Servicing and repair/ maint/ replacement of defective components /spare parts of PLC based control panels with all accessories modem, antenna complete with electrical connection panel installed at various locations for DG set control and monitoring.
(b) Servicing and repair/ maint/ replacement of defective components /spare parts of PLC based control panels with all accessories modem, antenna complete with electrical connection panel installed at various locations for the monitoring of LT feeders for street lights.
(c) Servicing and repair/ maint/ replacement of defective components /spare parts of AMR panel installed at various locations for the monitoring of Energy meters of DG sets.
(d) Servicing and repair/ maint/ replacement of defective components /spare parts of street lights installed at various locations for the monitoring of Energy meters.
The scope of work also covers the following : (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC).
(ii) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC)
Note for item No 43 :- (a) The comprehenive maint/ repair shall be carried out through the authorised representative of the OEM only.
(b) Cost of labour element towards removing of unserviceable/ defective spare part and re-fixing the serviceable spare part shall be deemed to be included in unit quoted rate. Supply only spare part shall be measured and paid seperately under the relevent item.
(c) Any other spare parts which have not covered in the relevent item given here in below but are required to make in functional condition deemed to be included in the unit quoted rate.
(d) The unit quoted rate shall be inclusive of One Engineer/ Supervisor per day having minimum 05 years experience in SCADA system. Documentary proof of experience of engineer/ technician shall be produced to Enginner-in-Charge before commencement of work. If extra manpower is required for smooth functioning of above mentioned system, rate for same deemed to be inclusive in unit quoted rate.
(e) Service Enginner of OEM or authorised service centre shall visit at least once in every month and during major break down or as and when required for the inspection, servicing, repair, rectification of problem and submission of report.
(f) All the charges for the communications, i.e. 01 Nos broad band connection with static IP at Kalpa Pump House and GPRS enabled data cards used in all PLC based panel related to this scope of work deemed to be inclusive in the quoted unit rate.
(g) SCADA reports related to all above mentioned system shall be mailed to Engineer-in-Charge/ concerned JE on weekly basis.
(h) All complaints related to unservicability/ break down of the system shall be attended with in 8 hours, if failed to rectify the system within the stipulated time, a penalty @ Rs. 500 per day will be deducted from the dues of the contractor.
(j) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(k) The decision of the Accepting Officer in this regard shall be final and binding.
(l) The servicing of Motorised valve, PLC base control Panels, communication Panels, shall be done by authorized representative of the Manufacturer only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him .
(m) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer (OEM) of PLC based Panels only. The programmer shall submit a letter from the manufacturer as proof of his being an authorized representative of the manufacturer. The programmer shall also submit a signed report on original letter head of the manufacturer (OEM) that servicing has been carried out by him.
(n) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer of PLC based Panels only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him.
Supply, Installing, Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 meters, Accuracy : 0.5 % minimum Supply Voltage : 24V, DC Output : 4-20 MA, Sensor Beam : Ultrasonic, connetion : Flying leads, IP rating : IP67, protected against reverse polarity and transient over voltages including taking down existing unserviceable one complete all as specified and directed. Make: BANNER/NIVELCO/VISIONTEK/MAESTRO/E+H/SIEMENS or existing make/brand of defective components/spare parts.
Supply and fixing in repairs diesel Level Sensor with 200mm float body length and suitable for 1.5 Amps switching current, 30 Amps carry current complete all as specified and directed.
Supply and fixing in repairs power contactor 250 A 4P complete all as specified and directed. Make: Schnider/Siemens/L&T
Excavation in trenches not exceeding 1.5 mtr depth and n exc 1.5 mtr wide and getting out in soft/ loose soil complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25 Cms thick after laying and testing of cable complete all as specified.
Removing of excavated material to a distance not exceeding 50 meter and depositing where directed at level not exceeding 1.5 meter above the starting point complete all as specified and as directed
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
M&L in replacement cable protection cover with sub class ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
Supply and fix 2 core 1.5 sqmm PVC insulated and armoured cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Supply and fixing 4 core 1.5 sqmm PVC insulated and armoured cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Comprehensive maintenance of CMDS including operation of CMDS equipments, data collection, assigning of task through concerned JE, updation of feed backs of services carried out, compiling of entries related to MES services from different sources, preparation of daily, weekly, monthly summary of services of different categories, submission of reports to concerned AGEs/GE as per laid down format complete all as directed.
Note for item No 72 :- (a) The contractor shall employ round the clock one operator at CMDS centre having sound knowledge in complaint monitoring disposal system (CMDS) related software/ system.
(b) The operator shall be smart enough to deal with customers of MES regarding registration, lodging, assigning of complaint of user to concerned JEs, updation of jobs/ complaints after carried out by the contractor etc.
(c) Operator is responsible for compilation of user complaints in category wise like E&M, B&R & BS from different sources like manual registers, What'sApp groups, CMDS lodged entries, etc and forwarding of same to the concerned JE's on daily basis.
(d) Operator shall also be responsible to collect the completion/ update of work from concerned contractor/ JE and updation of job status in CMDS system.
(e) The operator shall submit lodged and compliance summary of complaints to the concerned AGE's/ BSO on regular weekly basis or as directed by GE.
(f) The cost of stationary, printer and cartridge required till the completion of the contract shall be deemed to be included in the quoted unit rate .
(g) In case of any failure in functioning of CMDS or task mentioned in above Para (b), (c), (d) & (e), a penalty @ Rs 500/- per day will be deducted from the dues of the Contractor.
(h) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(j) The decision of the Accepting Officer in this regard shall be final and binding.
Supply and fixing 6 core 1.5 sqmm PVC insulated and armoured cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Supply and fixing 5 pair 0.5sqmm PVC insulated and armoured communication cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Supply and fixing in repairs joint kit complete all as specified and directed. Make : Clip - Seal or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing MCCB 4P 63 Amps, 415V, 25 KA with nuts, bolts, washers and suitable size of lugs including taking down existing one complete all as specified and directed. Make : L&T, ABB, Schneider
Supply and fixing in repairs water Level Controller PCB-5 Level suitable for Power supply (12-14 VDC) or 16-18 VDC/ 100 MA relay out put : 240V/ 3 A Max complete all as specified and directed. Make: Splash/ICS or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs solenoid Valve 25mm, 230 V AC complete all as specified and directed. Make: JOHNSON CONTROLS/AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Electric motor suitable for actuator of 50/80/100mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing in repairs Butterfly valve for 80 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make:- L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply and fixing in repairs Cast Aluminium Top cover for Actuator suitable for 150/200mm dia of Butterfly Valve complete all as specified and directed
M&L in repairs G.I. tubing light grade 50mm bore for protection of cable under roads, crossings/culverts incl jointing at ends complete all as specified and directed. Make: Prakash Surya/ Jindal/ Tata
Comprehensive maintenance for SCADA servers:- a). At Kalpavihar: HP make CPU, LG make 40” monitor, Key board & mouse- HP make, HP Laser jet printer DLink broad band modem, DLink Ethernet switch b). Repair/ maint of any other hardware installed for monitoring of SCADA system also covered under this item. all as directed including necessary updation, antivirus etc. upkeep the service for the mentioned period.
Supply and fixing in repairs MCB 2P 16Amps complete all as specified and directed
Supply and fixing in repairs 1 KVA UPS with Maximum configurable (watts) : 800 watts, output frequeny (sync to main) 50 Hz normal input 230V AC, LED status display with indicators complete all as specified and directed. Make : APC/TATA liebert/ Lumnious/ Numeric
Supply and fixing in repairs in replacement UPS Battery complete all as specified and directed
Supply and fixing in repairs LT CTs complete all as specified and directed
Supply and fixing in repairs Electric motor suitable for actuator of 150mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing in repairs Butterfly valve for 150 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make:- L&T, AUDCO or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing in repairs Motorized actuator suitable for 50/ 80/ 100 mm bore of Butterfly valve complete all as specified and directed. Make: Hassel Hoffner/Rotork/ SD Tork/ Emerson or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing in repairs Hand Wheel for Actuator suitable for 50/80/100 mm dia of Butterfly Valve complete all as specified and directed
Supply, Installation, Testing and Commissioning of GPRS communication Modem along with suitable external antenna, patch chord and mounting accessories as given below including removal of existing unserviceable one:- (i) GSM - Quadband (ii) GPRS - Class 10. (iii) Voice/Data/FAX/SMS facility (iv) TCP/IP - Full ( FTP & E Mail add) Functional Features (i) Input/output Digital -01 (ii) Down load over the air iii) At command set ( GSM 07.05, GSM 07.07 and Wave com)>300 (iv) Auto restore -time reset.
Voice ,Data and SMS Features (i) Data circuit synchronous , transparent and non transparent up to 14,400 bits (ii) Automatic tax group 3 ( class 1 & class 2) (iii) MNP @ V, 42 BIS (iv) Text & PDU SMS (v) Point to point SMS ( MT/MO) (vi) UC S2 character set management
(vii) Din rail mounting (viii) casing- Metal/plastic (ix) Operating status LED INTERFACES (i) SIM Plug in card reader - 1.813 V (ii) PS 232 on 15 Pin Sub.D connector (iii) Pin power supply connector -04 pin DC (iv) SMA Antenna connector Temp Range (i) Operating range - 20+55 degreec/ -25 to 70 degree C (ii) Power supply -5 to 32 V DC (iii) Protection Class-IP 55 (iv) Certification -CE Certification, GCG Certification, ROHS Compliance. (v) Programming /Parameterization 01 modem - Direct. Make: MOTOROLA / VISIONTEK /MAESTRO/ SOLPRO/ MARSH AUTOMATION/ INTEGRATED CONTROL SYSTEM
Supply and fixing in repairs 9DB Antenna GPRS Modem complete all as specified and directed
Supply and fixing in repairs Temprature Sensor complete all as specified and directed : Make: Existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing in repairs MCB 4P 60Amps complete all as specied and directed.
Supply and fixing in repairs Electric motor suitable for actuator of 200mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Butterfly valve for 200 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AAUDCO or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs Motorized actuator suitable for 150 mm bore of Butterfly valve complete all as specified and directed. Make: Hassel Hoffner/Rotork/ SD Tork/ Emerson or existing make/ brand of defective components/spare parts
Supply and fixing in repairs single phase modbus compatible energymeter Module complete all as specified and directed. Make:- Adept or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing in repairs controller for AMF panel compatible for RS 485/ RS 232/ modem/ modubus communication complete all as specified and directed. Make: L&T/Siemens/ EPCOS/ GE
Supply and fixing in repairs Hand Wheel for Actuator suitable for 150/ 200mm dia of Butterfly Valve complete all as specified and directed
Supply, Installation, Testing and Commissioning of outdoor type power coated PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel made out of 1.6mm thick CRCA sheet for control and monitoring of 01 Nos Ultra Sonic Level Sensor, 02 Nos of motorised valves along with provision of arrangement for controlling of one more motorised valve as future expansion including taking out existing unserviceable one:- The panel shall consist of the following equipments; (i) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC . (ii) 4" LCD HMI (iii) Transformer with regulated output voltage of 230V +/-5%, (iv) SMPS of Suitable rating (v) Set of Control Relays and suitable MCB (vi) Audio visual generator (vii) Suitable No. of LED Indicators for easy visualisation (viii) Selecetor Swtiches (ix) Push Buttons / Illuminated Push Buttons (x) 0.5 sqmm multistrand internal wiring with ferruling and suitable lugs. (xi) Ethernet Card 6020 (xii) Media Converter (xiii) Ethernet Switch (xiv) LIU(Light Interface Unit)box patch chord and mounting accessories with following specification. Communication: Primary- OFC, Stand by: GPRS Make of Control Panel: RUBIX AUTOMATION / INTEGRATED CONTROL SYSTEMS /MARSH AUTOMATION
Note for item No 113 : The unit quoted rate shall be inclusive of the following :-
(a) The cost of communication for a period of 12 months from the date of completion of work.
(b) Creating additional screens in the existing SCADA system for monitoring and controlling of the motorised valves.
(c) Excavation , earth work , Provision of PCC plinth etc required for instllation of panel
Supply and fixing in repairs 6F HDPE sheathed armoured uni-tube SM optical Fibre cable with central loose tube with jelly compound and high quality electro chromium coated corrugated steel type laid over head on existing available supports all as specified and directed Make : Polycab / Plaza / Havells.
Note :- Due to security reason, it will be the responsibility of the contractor to submit the list of labour i.e Site Engineer, Supervisor and killed labour before commencement of work to the Engineer-in Charge for police verification. Labour employed by the contractor against the work should carry photo identity card issued by the contractor
PRIYA ENTERPRISES
KSR AND COMPANY
eurekaenterprises
Recktronic Devices and Systems
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .