Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
16 Oct 2026, 1:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
35 conditions · 6 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of Air-conditioning system at PWI and IOW Office FKG,MXN,SLGR(E),SLGR(W),NAM,NTSK over TSK Division. In Connection with work "Furkating Jn.-Jorhat Town-Mariani Jn.(SL)-TBR-49.500 Tkm Work.
LV-T-14-TSK-964~NFR
LV-T-14-TSK-964
Open
Works - General
6 Months
Tinsukia, Assam
₹0
₹18,400
24 Sept 2026
24 Sept 2026
2 Oct 2026
23 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,21,455 | ||
| — | 10.00 | — | — | ||
| Supply, fitting, fixing of Inverter Split Air Conditioner 1.5 Ton , BEE 5 Star Rated , ISEER: Not less than 5.0, Cooling Capcity: Not Less than 4800 Watts ,Compressor: Rotary, Refrigerant: R32/R290/R410A,5-in -1 supper convertible cooling option, 100% copper tube of condenser coil, operating on 230V AC 50Hz, provided with HD filter and Antivirus protection including required copper connecting pipe & bracket for fixing of outdoor unit on wall. | — | — | — | 4,42,810 | |
| — | 10.00 | — | — | ||
| Providing and fixing of casing-capping/recessed wiring for AC point with 6.0 sq.mm copper conductor cable, including suitable MCB-protected power point with rating of 16 Amps, switch/push starter, necessary accessories, connections, testing and commissioning, complete as required. | — | — | — | 18,100 | |
| — | 50.00 | — | — | ||
| Supply, laying of PVC pipe 20 mm dia(Medium gaige) with all acesories. | — | — | — | 2,175 | |
| — | 50.00 | — | — | ||
| Supply, laying of UPVC pipe 20 mmdia Schedule 40 for AC Outlet Pipeline with required Bends, Coupler etc as per direction of Engineer Incharge at Site. | — | — | — | 18,600 | |
| — | 120.00 | — | — | ||
| Supply, laying,connection, testing and commissioning of cable size 16 mm.sq. 4 core ,LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured cable having Aluminium Strip, Glavanised Wire Solid Aluminum Conductor, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. As per PCEE DRWG:PCEE/ELG/DRG/2024/2 Dated:04.10.2024 | — | — | — | 1,20,240 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing of Bus Bar Chamber 3 phase and Neutral (4P) with Copper Busbar 100 Amps, 8 way .The busbar chamber to be fabricated using sheet steel (CRCA) of 1.6mm thickness and epoxy powder coated to give superior & lasting finish. The bus bar sections to be made of ETP grade copper & dull tin plated and the bus bar supports are made of DMC (Dough moulding compound). The neutral bus bar to be fully rated. The Bus Bar Chamber should conform to IS:8623/IEC 60439 (Panel sub assemblies) IS: 2147/IEC60529 (Degree for protection). | — | — | — | 1,68,950 | |
| — | 5.00 | — | — | ||
| Supply , fitting fixing of SPN MCB DB Double Door 8 Way, IP 45 with (i) MCB DP 63 A C series-1 No, (ii)MCB DP 32A C series-3 Nos | — | — | — | 38,250 | |
| — | 100.00 | — | — | ||
| Supply,Laying ,testing & commissioning of 10 mm.sq. Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volt Conforming to IS 694 | — | — | — | 21,100 | |
| — | 10.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe , 6 SWG GI wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 41,430 | |
| — | 50.00 | — | — | ||
| Supply of copper tube pipe line 1/2"+1/4" copper tube with insulation sleeve with 4core copper cable 1.5 sq.mm suitable for AC units upto 1.5Ton Capacity. | — | — | — | 34,850 | |
| — | 10.00 | — | — | ||
| Supply of MCB Protected Power Unit Having DP MCB 25A 10KA BC C series-1 No., 25A Heavy Duty Socket, push starterEnclosed in 6 Module PVC Box and Cover Plate | — | — | — | 14,950 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument964.pdf
ATTACHMENT
GCCAPRIL2022WITHALLACS.pdf GCC 2022 WITH ACS
ATTACHMENT
AnnexuresSectionVII.pdf
ATTACHMENT
GCCAPRIL2022WITHALLACS.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .