Manager- Electrical
2nd Floor NICT Building ,NSCBI Airport Kolkata700052
Upgradation and Rearrangemant the Electrical Distribution System Including Replacement of some Old Wires. Fitting and DB s in Cargo shad and Upgradation and Rearrangement the Street Light Distribution System Including Replacement of some Old Fitting
2021_AAICL_70983_1
AAICLAS/KOL/ELEC/IXB/01
Open Tender
Electrical Works
Item Rate
120 days
CPC Complex Bagdogra Airport
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
AAICLAS CO LTD
₹18,357
24 Mar 2021
23 Feb 2021
8 Mar 2021
23 Feb 2021
6 Mar 2021
23 Feb 2021
23 Feb 2021 - 25 Feb 2021
Amount
Upgradation and Rearrangemant the Electrical Distribution Systyem Including Replacement of some Old Wires.Fitting and D.B's in Cargo shad Bagdogra Airport.
Wiring For Circuit /submain alon with earth wire with the folloing size of FRLS insulated copper conductor singe core cable in surface/Recessed PVC Conduit as required (Make -KEI/Polycab) 2x4 sq. mm + 1x4 sq. mm.
2x6 sq. mm. + 1x6 sq. mm.
2x2.5 sqmm. + 1x2.5 sq. mm.
Supply and fixing of 8 way doudle door SPN Distribution Bord 415 v. on Surface complete with interconnections.power painted including earthing etc.( Make-LEGRAND/L&T)
Suply and fixing 5-32 Amp.Rating 240 v. 10 KA C curve Single pole MCB suitable for inductive load of following poles in the existing MCB DB complete with connectins testing and commissioning etc as required (Make-Legrand/L&T)
supply and fixing 20Amp .Rating 240V.10 KA C curve Double pole isolator suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required ( Make - Legrand/L&T)
supply and fixing 20Amp .Rating 240V.10 KA C curve Double pole isolator suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required ( Make - Legrand/L&T)
Supply and laying folloing sized ISI marked XLPE insulated and PVC sheathed alumonium conductor armoured U.G cable of 1.1 KV grade on wall surface /U.G/HDPE pipe as reqired,including lugs and brass compression Gland etc.(2core x 6 sq. mm) (Make -KEL/Polycab/Havvels)
Supply and laying of 50mm dia HDPE p[ipe ( Mediam class) in ground (0.75m. Deep) including excavation and refiling the trench etc as required.(Make: Supreme)
Providing and laying following dia G.I pipe (Medium class) in ground complete with accessories including trecching and refilling etc as required
wiring forground controlled (Loop) light point /fan point (without independent swit etc.)with 1.5sq.mm.FRLS PVC insulated copper conductor single corecable in surface/Recess PVC conduit with modular switch .modular plate suitable GI box and earting the point with 1.54 sq. mm . FRLS PVC insulated copper conductor single cord cable etc as required
SITC of surface mounted 2' x 2' LED luminare made of CRCA whith powre coated housing on ceiling complete with electronic constsnt current driver connecting with 3 x 1.5 1.5 sq .mm. FRLS PVC insulated copper conductor single core wire etc as required ( Make -Philip/crompton/jaquar/BAJAJ)
supply and fixing of 3 module GI box alongwith base cover plate for modular swich box including conncetions as required (Make-Legrand/mk/Anchor)
supply and fixing of following modular switch /shockets on the existing modular switch box including connection as required(Make-Legrand/MK/Anchor)
3pin 15/16 Amp.Switch
3pin 15/16Amp.Socket
3pin 5/6 Amp.Switch
3pin 5/6 Amp.socket
supply and fixing of folowing modular fan regulator on exising modular switch box including connection as required ( Make -Legrand/MK/Anchor )
supplying and fixing modular blanking plate on the existing modular switch box including connactions and excluding modular plate as required. (Make -Legrand/MK/Anchor)
supply and fixing of following single phase modular Ac/Motor starter on the modular switch box including 15/25 amp. Socket and 25 amp plug top and connection as required (Make-Legrand/MK/Anchor)
SITC of surface /recess mouting vertical type 6way double door 415 volt TPN MCCB Distribution Bord of the sheelt steel, dust protected (IP-43) power painted, inclusive of mounting MCCB'swith 63amp .4pole 25KA. BCCB as incomer ,(but without MCB'as )complete with interconnections. including earting etc.(Make-Legrand/L&T)
Removed old damage tube light fitting including statter and chock and replace them with new LED tube light with necessary connection as required including cleaningb and refixing the fitting to make it work properly as required
supply and delivery of 18 w master led tube light (Make : Philips/Crompton)
supply and laying following size ISI marked XLPE insulated and PVC sheathed aluminium conductor armoured U.G cable of 1.1 KV grade on wall surface / U.G/ HDPE pipe as requiredv , including Lugs and brass compression Gland etc (4core x10sq.mm)(Make-KEL/Polycab/Havvels)
dismantling the whole Electrical distribution system/damaged DBs/Burnt out motor /Feeder pannels etc. as Directed by the Authority.
Upgradation and Rearrangement the Street Light Distribution System Including Replacement of some Old Fitting .Cables and Loop Box In the Compound of Cargo shed At Bagdogra Airport
Wiring For Circuit/Submain along with eath wire with the folloing sizes of FRLS insulated Copper Conductor single cord Cable in surface/ Recessed PVC Conduit as reqired(Make-KEI/Polycab) 2x2.5 sq.mm. + 1x2.5 sq.mm.
Supply and laying folloing sized ISI marked XLPE insulated and PVC Sheathed aluminium conductor armoured U.G cable of 1.1KV grade on wall surface/U.G/HDPE pipe as reqired,including Lugs and brass Compression Gland etc.(2core x 10 sq .mm.)(Make-KEL/Polycab/Havvels)
Supplying and Laying of 50 mm dia HDPE pipe in ground (0.75 m. deep )including excavation and refilling the trench etc as required.(Make: supreme)
providing and laying following the dia G.I pipe(Medium class) in ground complete with accessories including trecching and refilling etc as required
Supplying and embedding following dia G.I pipe(40mm medium class)in pole collar / foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Dismantling the old damaged street light fillings from the existing pole and supply and drawing 3 x 1.5 sq. mm.FRLS PVC insulated copperv conductor single cord wire from cable loop box to fittings connection etc. as required.
Cleaning the existing 9 mtr. Street light poles from top to bottom including header, and painting the same by two coat of synthetic enaamel paint after one cote of red oxide iron primer (by approved brand) etc as required.
Lifiting and Lowering of Submersile motor Pumping set along with 80 mm Dia G I Colum pipe of length 60 mtr> ( Approx) in the Existing Bore well including thorough servicing and repairing the same, supplying and Connerction with 3 core 4 sq, mm. Copper conductor Flat Cable from the starter to the Submersible pump (qnti as reequired at site). Supplying and Fixing of 6 mm . dia PVC coated Steel wire Rope along with accessories for holding the submersible pump ( qnty. as required at site).
Supplying and laying of following size GI pipe ( 80 mm . Dia Medium Class) with heavy duty sockets in the existing bore well as column pipe including cutting and threading etc as required.
Supplying and fixing the following accessories on the existing common delivery / suction line i/c threading, painting, testing as required 40 mm. dia GI Elbow- 1 no. 40 mm dia GI Nipple- as required. 40 mm dia GI Socket- 1 no. 40 mm dia GI Union- 1 no. 40 mm dia Gun metal Gate Valve- 1 no. 80 mm dia Gun metal Gate Valve- 1 no. 80 mm dia GI Nipple- as required.
SITC of LED street light luminaire having light output minimumm 4500 lumens, with pressure die-cast housing with toughened glass and IP 66 protection in existing street light pole suitable for 230V single phase, 50 Hz, AC supply complete with all accessories (MAKE: Crompton- LSTP -45-CDL/BAJAJ-BRTFG 45W LED WW/ or Equivalent to Philips)
SITC of LED street light luminaire having light output minimumm 2500 lumens. With pressure die-cast housing with toughened glass and IP 66 protection in existing strreet light pole suitable for 230 V single phase, 50 Hz , AC supply complete with all accessories i/c supply and drawing 3 x 1.5 sq . mm. FRLS PVC insulated copper conductor single core wire from cable loop box to fittings connection etc. As required. (Make: Crompton - LSTS-25- CDL/ BAJAJ-BCLST 25W LED I V2/ or Equivalent to Philips.
Supply and Fixing of 200 mm x 200mm x100mm size (approx) cable entry moulded outdoor cable loop box made out made out of poly carbonate andhaving hinged cover plate . Incliding 4 way heavy duty connector , bin bar for MCB ,1 no, 6amp. SP MCB , fixing with existion pole by providing and fixing 25x5 mm MS clamp etc as required (make: Syntex/Hensal)
SITC of 40 Amp. 4pole Isolator. ( Make: L&T/Legrand)
SITC of Outdoor type 32 Amp. 5 PIN Industrial socket with IP-66 protection and having provision of MS Iron Stand/Frame For smooth operation.
M/S. KRISHNA COMMERCIAL CORPORATION
SUPER BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .