| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.4 L+₹76,160 (3.53%)Rejected-Finance B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹25.4 L+₹3.9 L (17.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹27.5 L+₹5.9 L (27.4%)Rejected-Finance 00 00 BAIRIYA NEAR KALI MAA MANDIR BALLIA UTTAR PRADESH 277502 | BALLIA | UTTAR PRADESH | 277502 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | SAMEER ELECTRICAL SUPPLIER L2 | Neha Enterprises L4 | Raj Contruction L3 | S S TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||||
| 1.10 | Dismantling of ceiling fans, single phase, 230 volts AC of 1200 mm/ 1400 mm sweep of any make / model except of old vintage fans, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing gauge including cleaning of slots and providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, binding with cotton thread and varnishing over all with winding varnish, cleaning of bearing, housing and shaft, replacing minor spare parts such as split pins, blade screws etc as required and re-assembling and depositing the repaired fan to MES store yard after testing complete all as specified and directed. | 200 | Each | 200 ₹40,000 Lowest | 330 ₹66,000 | 250 ₹50,000 | 270 ₹54,000 |
| 2.00 | All as per item No. 1.00 here in before but exhaust fan, 400/ 450 mm sweep, single phase, 230/240 volts AC. | 8 | Each | 300 ₹2,400 | 280 ₹2,240 Lowest | 300 ₹2,400 | 350 ₹2,800 |
| 3.00 | All as per item No. 1.00 here in before but exhaust fan, 300/ 380 mm sweep, single phase, 230/240 volts AC. | 30 | Each | 250 ₹7,500 Lowest | 250 ₹7,500 Lowest | 280 ₹8,400 | 350 ₹10,500 |
| 4.00 | All as per item No. 1.00 here in before but exhaust fan, 230/ 250 mm sweep, single phase, 230/240 volts AC. | 30 | Each | 200 ₹6,000 Lowest | 210 ₹6,300 | 250 ₹7,500 | 350 ₹10,500 |
| 5.00 | All as per item No. 1.00 here in before but wall / pedestal fan, of any sweep and capacity, single phase, 230/240 volts AC
Notes for item no 1 to 5:-
(i) The quoted rate deems to include for all minor repairs required for making the complaint functional.
(ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in present of concern JE E/M and winding wire sample produced for sample before winding work start.
(iii) Contractor staff will collect defective fans from concern JE E/M for checking the fans and after opening it, defects will be intimated to JE E/M before repairing.
(iv) Bearing of fan shall be measured and paid seperately. | 10 | Each | 300 ₹3,000 | 250 ₹2,500 Lowest | 250 ₹2,500 Lowest | 350 ₹3,500 |
| 6.00 | Dismantling of BLDC ceiling fans (with/ without remote control) of sizes 1200mm/ 1400mm sweep of any make / model except old vintage fans, dismantling its stator, rotor, taking out burnt PCB and providing new PCB, 35-40 W, AC single phase, 230 volts of existing size including cleaning of slots, cleaning of bearing, housing, shaft and replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES store yard after testing complete all as specified and directed. | 100 | Each | 750 ₹75,000 | 500 ₹50,000 | 300 ₹30,000 Lowest | 800 ₹80,000 |
| 7.00 | S&F in replacement of LED slim square/ circular panel light fitting for surface ceiling light, 12 watts, colour warm white including making connection with 3 core, 23/0.0076 copper insulated cable from celing rose to fittting connector complete all as specified and directed. | 20 | Each | 600 ₹12,000 | 450 ₹9,000 | 500 ₹10,000 | 300 ₹6,000 Lowest |
| 8.00 | S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed. | 200 | Each | 5 ₹1,000 Lowest | 12 ₹2,400 | 10 ₹2,000 | 10 ₹2,000 |
| 9.00 | S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nut, bolt, washer and split pin complete all as specified and directed. | 100 | Each | 10 ₹1,000 Lowest | 20 ₹2,000 | 20 ₹2,000 | 20 ₹2,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
9 Dec 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL 3 EME CENTER BHOPAL PIN 462030
COMPREHENSIVE REPAIRS AND MAINT OF INTERNAL ELECTRIFICATION EM WORKS INCL GEYSER CEILING FANS EXHAUST FANS WALL MOUNTED FAN AIR CIRCULATING FAN RO AND SUMMER APPLIANCES SWH AND CONNECTED WORKS OTM ACCN AT SI LINES AND SUKHI SEWANIYA UNDER GE BHOPAL
2025_MES_737862_2
8446/E8
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹70,000
Yes
28 Feb 2026
25 Nov 2025
11 Dec 2025
25 Nov 2025
9 Dec 2025
2 Dec 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Dismantling of ceiling fans, single phase, 230 volts AC of 1200 mm/ 1400 mm sweep of any make / model except of old vintage fans, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing gauge including cleaning of slots and providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, binding with cotton thread and varnishing over all with winding varnish, cleaning of bearing, housing and shaft, replacing minor spare parts such as split pins, blade screws etc as required and re-assembling and depositing the repaired fan to MES store yard after testing complete all as specified and directed.
All as per item No. 1.00 here in before but exhaust fan, 400/ 450 mm sweep, single phase, 230/240 volts AC.
All as per item No. 1.00 here in before but exhaust fan, 300/ 380 mm sweep, single phase, 230/240 volts AC.
All as per item No. 1.00 here in before but exhaust fan, 230/ 250 mm sweep, single phase, 230/240 volts AC.
All as per item No. 1.00 here in before but wall / pedestal fan, of any sweep and capacity, single phase, 230/240 volts AC Notes for item no 1 to 5:- (i) The quoted rate deems to include for all minor repairs required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in present of concern JE E/M and winding wire sample produced for sample before winding work start. (iii) Contractor staff will collect defective fans from concern JE E/M for checking the fans and after opening it, defects will be intimated to JE E/M before repairing. (iv) Bearing of fan shall be measured and paid seperately.
Dismantling of BLDC ceiling fans (with/ without remote control) of sizes 1200mm/ 1400mm sweep of any make / model except old vintage fans, dismantling its stator, rotor, taking out burnt PCB and providing new PCB, 35-40 W, AC single phase, 230 volts of existing size including cleaning of slots, cleaning of bearing, housing, shaft and replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES store yard after testing complete all as specified and directed.
S&F in replacement of LED slim square/ circular panel light fitting for surface ceiling light, 12 watts, colour warm white including making connection with 3 core, 23/0.0076 copper insulated cable from celing rose to fittting connector complete all as specified and directed.
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nut, bolt, washer and split pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod complete all as specified and directed
S&F in replacement gun metal bush, self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement flexible copper conductor stranded 1100 Volt PVC insulated cable, three core, 23/0.0076 size complete all as specified and directed.
S&F in replacement fan condenser 2.5 mfd, 230 volts complete all as specified and directed.
S&F in replacement fan condenser 3.15 mfd, 230 volts complete all as specified and directed.
S&F in replacement fan condenser 4.0 mfd, 230 volts complete all as specified and directed.
S&F of bearing No. 6201 'ZZ' of fan complete all as specified and directed.
S&F of bearing No. 6202 'ZZ' of fan complete all as specified and directed.
S&F of bearing No. 6203 'ZZ' of fan complete all as specified and directed.
S&F of bearing No. 6204 'ZZ' of fan complete all as specified and directed.
Taking down ceiling / wall fan from fan hook after disconnecting from ceiling rose including dismantling of fan parts i.e. down rod and connector/ condenser, nut, bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc. complete with and incluidng servicing the same by cleaning, greasing/oiling in side surface of rotar by CTC with sand paper and repair and re-fitting / reassembling and making the fan fuctional and fixing the fan in position after testing complete all as specified and directed. Note:- Defective rubber packing (garari), condenser, condenser carrier clip (PVC), in build connector two way shall be measured and paid separately.
Taking down exhaust fan after disconnecting from ceiling rose including dismantling of fan parts i e. connector/ condenser, nuts, bolts, condenser carrier clip (PVC), in build connector two way, etc. complete with and incluidng servicing by cleaning, greasing/oiling in side surface of rotar by CTC with sand paper and repair and re-fitting / reassembling and making the fan fuctional and fixing the fan in position after testing complete all as specified and directed. Note:- defective rubber packing (garari), condenser, condenser carrier clip (PVC), in build connector two way shall be measured and paid separately.
S&F in replacement down rod for ceiling fans duly painted with synthetic enamelled paint, 300 mm long & 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed.
S&F in replacement down rod for ceiling fans duly painted with synthetic enamelled paint, 600 mm long & 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed.
S&F in replacement exhaust fan metal blade duly powder coated suitable for 450 mm/380 mm sweep as per existing complete all as directed.
S&F in replacement exhaust fan metal blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as directed.
S&F in replacement blade assembly of celling fan of 1200 mm sweep (set of three) of approved make, colour and pattern as per existing complete all as specified and directed.
S&F in replacement blade assembly of celling fan of 1400 mm sweep (set of three) of approved make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nuts, bolts etc and all other connected accessories duly painted suitable for 450 mm/ 380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan (any sweep) of approved make, colour and pattern as per existing model complete all as specified and directed
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc and all other connected accessories duly painted suitable for 230 mm / 300 mm sweep exhaust fans complete all as specified and directed.
M&L for cleaning, washing and preparation of old painted surfaces of ceiling fan upto 1200/1400 mm sweep and applying painting with two coats of DUCO paint, white, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed. Note:- Taking down and fixing of fan will be measured seperately.
M&L for cleaning, washing and preparation of old painted surfaces of exhaust fan of 280/ 300/ 380/ 450 mm sweep and applying painting with two coats of DUCO paint, smoke grey, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed. Note:- Taking down and fixing of fan will be measured seperately.
S&F of ceiling fan regulator, electronic step type, 240 Volts, AC 50 Hz, single phase, 100 watts, flush type complete all as specified and directed.
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nuts, bolt, etc and reassembling, re-fixing and testing the fan complete all as specified and directed.
Removing unserviceable fan bearing shaft (of any type & any sweep fans) and welding broken area of shaft including threading in lathe machine of appropriate size and refixing in ceiling fan, any type complete all as specified and directed.
Taking down unservicable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface complete all as specified and directed .
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three, single core, PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area including PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire including and drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note:- Three runs of 6.0 sqmm cable & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three, single core, PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area including PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire including and drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note:- Three runs of 6.0 sqmm cable & PVC conduit pipe shall be measured as one unit length.
Taking down carefully existing point wiring (any type and size) with wooden batten/ surface PVC conduit (with its fittings)/ PVC casing-capping or any other type of light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface complete all as specified and directed.
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one, one way switch complete with and including single core PVC insulated unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694:2010, ISI marked, annealed multistranded copper conductor drawn through and including medium grade PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site but not less than 20 mm noninal size including modular / non modular type all accessories/ fitting, metal flush box, junction boxes, inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multi stranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chases and making good to distrubed surfaces of wall in cement mortor 1: 3 including white wash / distemper/ other painting complete all as specified and directed. Note:- Cost of cutting chases and making good shall be included in the quoted rates.
All as per srl item No 40.00 here-in-before but for one switch socket combination, 5/6 Amp on independent board complete.
All as per srl item No 40.00 here-in-before but for one three pin socket outlet, 5 Amp on same board with other switches complete.
All as per srl item No 40.00 here-in-before but for one switch socket combination, 6 pin, 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete.
All as per srl item No 40.00 here-in-before but for one switch socket combination, 6 pin, 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete.
M&L for casing caping/ surface conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010, ISI marked, annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm noninal size including modular / non modular type all accessories/ fitting, metal flush box, junction boxes, inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multi stranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chases and making good to distrubed surfaces of wall in cement mortor 1: 3 including white wash / distemper/ other painting complete all as specified and directed. Note:- Cost of cutting chases and making good shall be included in the quoted rates.
All as per srl item No 45.00 here-in-before but for one switch socket combination, 5/6 Amp on independent board complete.
All as per srl item No 45.00 here-in-before but for one three pin socket outlet, 5 Amp on same board with other switches complete.
All as per srl item No 45.00 here-in-before but for one switch socket combination, 6 pin, 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete.
All as per srl item No 45.00 here-in-before but for one switch socket combination, 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete.
S&F in replacement building security light fitting complete with 36 watt LED type, pressure die-cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution. fixed on bracket made out of GI pipe 32 mm dia (light grade) 1.2 metre long and MS clamps, nuts, bolts, washers and connected with twin core cable 1.5 sqmm from ceiling rose to fitting complete all as specified and directed.
S&F of switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC complete all as specified and directed.
S&F of socket outlet multipurpose 2-in-1 having provision for 3 pin, 6 Amp, flush type, 230 volt AC complete all as specified and directed.
S&F of switch socket combination, multipurpose, 3 pin, 5-15 Amp, flush type including PVC gang box, ISI marked complete all as specified and as directed.
Dismantling geyser of 25 ltrs capacity and of any description including M&L for cleaning and de-scaling the inner tank and other parts / accessories such as inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using & circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/ scale is removed and brazing for stopping the leakage of copper inner tank by gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing, fixing and installating the geyser in position after testing complete all as specified and directed. Notes:- (i) De-scaling chemical shall be concentrated HCL of approved make. (ii) Painting of Geysers shall be measured and paid for separately under appropriate item of sch. (iii) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (iv) Spares parts required shall be measured and paid seperately.
All as per item srl No. 54.00 here-in-before but geyser of capacity 50 Ltrs complete.
S&F of 1.5 KW capacity heating element (ISI marked) round type/ thread/ triangle/ push/ screw base type with ‘O’ ring including making electrical connections complete all as specified and directed.
S&F of 2.0 KW capacity heating element (ISI marked) round type/ thread/ triangle/ push/ screw base type with ‘O’ ring including making electrical connections complete all as specified and directed.
S&F of 1.5/ 2.0 KV electronic heating element (ISI marked) fitted with auto cut thermostat suitable for 25/ 50 ltrs geyser including making electrical connections complete all as specified and directed.
S&F in replacement SS geyser assembly suitable for 25 ltrs capacity, ISI marked complete all as specified and directed.
S&F in replacement SS geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified and directed.
S&F in replacement thermostat suitable for 25/ 50 Ltrs geysers (ISI marked) with setting range 30 to 80 degree centigrade, 230 volts AC electric supply complete all as specified and directed.
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geysers complete all as specified and directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geysers complete all as specified and directed.
S&F in replacement outer tank made of steel sheet duly powder coated suitable for 25 Ltr geysers complete all as specified and directed.
S&F in replacement outer tank made of steel sheet duly powder coated suitable for 50 Ltr geysers complete all as specified and directed.
S&F in replacement mild steel bottom cover suitable for 25 Ltr geysers complete all as specified and directed.
S&F in replacement mild steel bottom cover suitable for 50 Ltr geysers complete all as specified and directed.
S&F in replacement indicating lamp (set of two), 230 volts, 50 HZ AC suitable for geyser any type (round, square or rectangular type) for any capacity geysers complete all as specified and directed.
M&L for cleaning, washing and preparation of old painted surfaces of 25 ltrs capacity geysers and applying painting with two coats of DUCO paint, white, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed.
M&L for cleaning, washing and preparation of old painted surfaces of 50 ltrs capacity geysers and applying painting with two coats of DUCO paint, white, using spray painting machine including writing MES Nos on ceiling and exhaust fans complete all as specified and directed.
S&F in replacement of single pole and neutral sheet metal enclosure with two pin and earth, plug and socket, single phase, 240 V with and including one No single pole MCB of capacity 20 Amps having `C` charactristic, breaking capacity 10 KA including industial plug top complete all as specified and directed.
S&F in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in replacemnt PVC connections 15 mm size with brass nuts, nylon braided, heavy duty, 600 mm long including rubber washers (suitable for hot water) complete all as specified and directed.
S&F in replacement of pressure release valve suitable for 25/ 50 Ltr capacity geysers complete all as specified and directed.
S&F in replacement PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified and directed.
S&F in replacement LED decorative aluminium casted edge ceiling light, recess mounting LED 2' x 2' luminaire, 36 watt with all accessories internally pre-wired and connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm, two core complete all as specified and directed.
S&F in replacement coral post top lantern fitting, 25 Watt, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with accessories complete all as specified and directed.
S&F in replacement of LED tube light fitting, surface mounted luminanaires, 40 watt, 240 V, decorative ultra slim round/ square profile, LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient with bipin holders, LED lamps, connector block, etc with all accessories, internally prewired and making connection with flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement of white LED tube light fitting, two feet, 10 watt, slim design, 230 volts including making connection with 3 core 23/0.0076 insulated copper wire from celing rose to fitting connector complete all as specified and directed.
S&F in replacement of warm LED tube light fitting, two feet, 10 watt, slim design, 230 volts including making connection with 3 core 23/0.0076 insulated copper wire from celing rose to fitting connector complete all as specified and directed.
S&F of PVC insulated unsheathed, FRLS copper cable, 1.5 Sqmm, 230 Volts AC complete all as specified and directed.
S&F of PVC insulated unsheathed, FRLS copper cable, 2.5 Sqmm, 230 Volts AC complete all as specified and directed.
S&F of modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular bell push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular socket outlet, 2-in-1, 5 pin, 6 Amps, two module, 240 volts, controlled by one switch complete all as specified and directed.
S&F of modular socket outlet, 2-in-1, 2/3 pin, 6/16 Amps, two module, 240 volts, complete all as specified and directed.
S&F of modular switch socket combination, multipurpose, 6 pin, 16 Amp, 3 module, 240 Volts complete all as specified and directed.
S&F of modular fan regulator, electronic type, 5 step, high speed, 2 module, 240 Volts complete all as specified and directed.
S&F of modular metal flush box of 12 module complete all as specified and directed.
S&F of modular metal flush box of 6 module complete all as specified and directed.
S&F of modular metal flush box of 4 module complete all as specified and directed.
S&F of modular white cover plate with frame of 12 module complete all as specified and directed.
S&F of modular white cover plate with frame of 6 module complete all as specified and directed.
S&F of modular white cover plate with frame of 4 module complete all as specified and directed.
Taking down old unserviceable MCCB/ MCB DB of any size and capacity including MCCB/ MCB with wooden boards complete all as specified and directed.
S&F of factory made sheet epoxy powder coated sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 Amps rated bus bar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003, IP 54 protection over and including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. Note:- MCB shall be measured and paid seperatly.
S&F of factory made epoxy powder coated distribution board TP & N, 4 way (VTPN MCCB DB) and space for MCCB as incomer with metal door (IP-54 protection) fabricated from CRCA sheet and fixed semi flush to wall with and including isolated neutral bar, insulated bus bar assembly, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed. Note:- MCCB shall be measured and paid seperatly.
S&F of factory made sheet epoxy powder coated sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated bus bar, 8 way, double door enclosure made up of CRCA sheet steel, RAL 9003, IP 54 protection concealed in wail suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid seperatly.
S&F of factory made sheet epoxy powder coated sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated bus bar, 12 way, double door enclosure made up of CRCA sheet steel, RAL 9003, IP 54 protection concealed in wail suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid seperatly.
S&F of MCCB, 160 Amps, 3 Pole of breaking capacity 36 KA and making electrical connections by appropriate size of copper lugs complete all as specified and directed.
S&F of MCB, SP, 6 to 32 Amps, 240 Volts, 10 KA breaking capacity, 'B' curve and making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SP, 40 Amps, 240 Volts, 10 KA breaking capacity, 'B' curve and making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SPN, 6 to 32 Amps, 240 Volts, 'B' curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SPN, 40 to 63 Amps, 240 Volts, 'B' curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, TPN, 63 Amps, 240 Volts, 'B' curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, TPN, 100 Amps, 240 Volts, 'B' curve with over load and short circuit protection and rupturing capacity not less than 10 KA and making connection with suitable size copper lugs complete all as specified and directed.
S&F in replacement 3 pin plug top, AC-230 V, 15 Amps complete all as specified and directed.
S&F in replacement 500 ltrs capacity rotational moulded 3 layers HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia tank nipple complete all as specified and directed
S&F in replacement 1000 ltrs capacity rotational moulded 3 layers HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia tank nipple complete all as specified and directed
S&F in repairs 25 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and fixed with fittings such as (socket, nipple, union) etc. complete all as specified and directed.
S&F in repairs 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and fixed with fittings such as (socket, nipple, union) etc. complete all as specified and directed.
M&L for cleaning and degermination inside of RCC/ PVC water storage tanks of capacity not exceeding 500 Ltrs of any description and in any position comprising seven stage cleaning and sterilization of water tanks through bacteriological treatment complete all as specified and directed comprising of following stages:- (a) First stage is to drain out the water by using exit valve or high capacity dewatering systems or any other suitable method. (b) Second stage is to clean all algae formation inside the tank by using Terbac G5/ Inchlor-5/ NB-10 and scrubbing the walls of the tanks. (c) Third stage is for cleaning with fresh water by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and sterilization by using Terbac G5/ Inchor-5/ NB-10. (e) Fifth stage is for cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is for second bacteria screening and sterilizing method by using ultra violet ray ejector covering 360 degree with in the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend Terbac G65/ Inoxi-60/ NB-69. Notes:- (i) Test certificate of chemicals from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of defects occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/ blockage of outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
All as per item No. 113.00 here-in-before but of capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete.
S&F of solar energy collector panel made of aluminium body with 5mm thick toughened glass complete with copper fins of capacity 200 litres per day as per existing make complete all as specified and directed.
S&F of solar energy collector panel gasket made out of superior quality rubber to make system air tight, dust and water proof of capacity 200 litres per day as per existing make complete complete all as specified and directed.
S&F of compressed glass wool (insulation materials) 48 mm thick between solar energy collector panel copper tubes frame and aluminium body panel including securing it on panel by means of necessary adhessive complete all as specified and directed.
Supply and filling anti freezing liquid (20 ltrs can) for solar water heater system complete all as specified and directed.
Supply and filling oil coolant additive concentrate (pack of 10 Ltrs) suitable for DG set including taking out old one complete all as specified and directed.
Supply and filling distrilled water (5 ltrs can) for use in the batterys complete all as specified and directed.
Removing defective window/ split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair work as per requirement including cleaning the air conditioner with water and air pressure and to replacing un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as directed. Note: All spare parts such as compressor, fan motor, relay, capacitor, etc. shall be measured and paid separately under respective item.
S&F in replacement of battery lead of PVC insulated multi stranded copper conductor cable 25 Sqmm, single core complete all as specified and directed.
S&F in replacement of battery terminal of brass suitable for 12 V, 180 AH battery complete all as specified and directed.
S&F in replacement of battery charger with variable voltage and current setting suitable for charging 2 x 12 V battery in steel sheet cabinet with internal and external wiring including all measuring and control accessories/ instruments complete all as specified and directed.
Taking out window/ split type air conditioner of any make and capacity from position and cleaning the complete cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing including checking of electrical connection and re-fixing the same or other location after testing complete all as specified and directed.
S&F of new hermetically sealed rotary type compressor of 1.5 TR capacity AC's including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Kirloskar/ Carrier /Hitachi /Blue Star as approved by GE.
S&F of new hermetically sealed rotary type compressor of 2.0 TR capacity AC's including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas including testing complete all as specified and directed. Make: Kirloskar/ Carrier /Hitachi /Blue Star as approved by GE.
S&F of FHP motor of capacity 1/5 to 1/18, single phase, 920 RPM with starting and running capacitor suitable for window/ split AC's complete all as specified and directed.
S&F of starting capacitor 80-100 MFD/ 100-120 MFD/ 120-150 MFD suitable for window/ split AC's complete all as specified and directed. Make: Epcos or equivalent as approved by GE.
S&F of running capacitor 45 MFD suitable for window/ split AC's complete all as specified and directed. Make: Epcos or equivalent as approved by GE.
S&F of running capacitor 36 MFD suitable for window/ split AC's complete all as specified and directed. Make: Epcos or equivalent as approved by GE.
S&F of starting relay suitable for 1.0/ 1.5/ 2.0 TR AC's compressor complete all as specified and directed. Make: Classic or equivalent as approved by GE.
S&F of thermostat suitable for window/ split type AC's complete all as specified and directed. Make: INDFOSS/ Godrej or equivalent as approved by GE.
S&F of outer cover of GI sheet heavy duty duly powder coated painted for window type AC's of capacity 1.5/ 2.0 TR complete all as specified and directed.
S&F of front grill for window type AC's of any model as required at site complete all as specified and directed. Make: LG/ Lancer/ Blue star/ Carrier.
S&F of condenser/ cooling fan blade suitable for window type AC's of any make & capacity complete all as specified and directed.
S&F of blower fan motor suitable for split AC's of any capacity & make complete all as specified and directed.
M&L for repairing of PCB for window/ split type AC of any capacity & make complete all as specified and directed.
S&F of blower both end coupling complete set suitable for 1.5 / 2.0 TR split AC's of any make complete all as specified and directed.
S&F of cooling coil copper tube suitable for 1.5/ 2.0 TR capacity split type AC's complete all as specified and directed.
S&F of copper liquid line filter, one/ two way suitable for 1.5/ 2.0 capacity AC's complete all as specified and directed.
S&F of remote for window/ split AC's as per sample complete all as specified and directed.
S&F of PVC rounded 3 core, 4.0 Sqmm copper work shop cable complete all as specified and directed.
S&F in replacement wiring loom complete suitable for 1.5/ 2.0 TR capacity AC's complete all as specified and directed.
S&F of condenser/ cooling coil suitable for 1.5/2.0 TR capacity AC's including refrigerant gas, gas charging and welding etc. complete all as specified and directed.
M&L for rewinding of stator of FHP motor of size 1/5 to 1/18, single phase, 920 RPM with super quality copper wire of existing size complete with varnishing, backing and testing complete all as specified and directed.
M&L for cutting damaged tray from window type AC's and replacing same with existing shape and size including nuts, bolts, drilling, welding etc. suitable for 1.5 / 2.0 TR AC's complete all as specified and directed.
S&F in replacement outdoor PCB board suitable of inverter AC,s complete all as specified and directed.
S&F in replacement common sensor suitable for inverter AC,s complete all as specified and directed.
S&F in replacement BLDC door blower motor suitable of inverter AC,s complete all as specified and directed.
S&F in replacement PVC drain water pipe, 1/2" & 3 mtr long complete all as specified and directed.
S&F in replacement 5/8'' or 1/4'' or 1/2'' size brass outlet valve suitable for split AC,s complete all as specified and directed.
S&F in replacement BLDC inverter compressor suitable for 1.5/ 2.0 Ton capacity AC,s complete all as specified and directed.
S&F in replacement copper pipe of 5/8'' or 1/4'' or 1/2'' suitable for AC,s complete all as specified and directed.
S&F in replacement PVC insulated 2.5 Sqmm, 4 core copper cable complete all as specified and directed.
S&F in replacement outdoor condensor fan motor suitable for 1.5/ 2.0 TR capacity split AC,s complete all as specified and directed.
S&F in replacement copper condensor coil suitable for 1.5/ 2.0 TR capacity split AC,s complete all as specified and directed.
S&F in replacement PCB for non inverter indoor type split AC,s complete all as specified and directed.
S&F in replacement coil sensor and room sensor suiatble for split AC,s complete all as specified and directed.
S&F in replacement indoor cooling coil sensor suitable for split AC,s complete all as specified and directed.
S&F in replacement PCB suitable for single door refrigerator complete all as specified and directed.
S&F in replacement PCB suitable for double door refrigerator complete all as specified and directed.
M&L for filling and charging of refrigerant gas (R-22) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc. and testing complete all as specified and directed.
M&L for filling and charging of refrigerant gas (R-32) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc. and testing complete all as specified and directed.
M&L for filling and charging of refrigerant gas (R-410) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc. and testing complete all as specified and directed.
M&L for filling and charging of refrigerant gas (R-404) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc. and testing complete all as specified and directed.
M&L for filling and charging of refrigerant gas (R-600) (200 gms cans) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc. and testing complete all as specified and directed.
M&L for filling and charging of refrigerant gas hydro carbon (200 gms cans) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc and testing complete all as specified and directed.
M&L Charging of refrigerant gas (R-134A) (450 gms cans) including all necessary work such as refrigerant gas, welding to refrigerant pipe line etc and testing complete all as specified and directed.
S&F in replacement sealed compressor of inverter refrigerator upto 200 ltrs capacity including testing complete all as specified and directed.
S&F in replacement sealed compressor of inverter refrigerator of 200 and upto 400 ltrs capacity including testing complete all as specified and directed.
S&F in replacement thermostate, 240 V, 50 Hz suitable for refrigerator complete all as specified and directed.
S&F in replacement relay, 240 V, 50 Hz suitable for refrigerator complete all as specified and directed.
S&F in replacement OLP (Over load Protector), 240 V, 50 Hz suitable for refrigerator complete all as specified and directed.
S&F in replacement refrigerator bulb complete all as specified and directed.
S&F in replacement refrigerator timer complete all as specified and directed.
S&F in replacement refrigerator heater complete all as specified and directed.
S&F in replacement brass capillary tube, 0.31/ 0.36 mm dia and 3 mtrs long for refrigerator complete all as specified and directed.
Taking out unserviceable voltage stabilizers of capacity 0.5 KVA to 5 KVA from MES storeyard/ at various locations and repairing the same in MES work shop complete all as specified and directed. Notes: (i) Burnt transformer shall be re-winded in the contractor workshop and will be measured and paid seperately under respective item. (ii) Other spare parts shall be measured and paid seperately under respective item.
S&F of main relay, 25 Amps, 24 Volts, suitable for 0.5 KVA to 5 KVA voltage stabilizers complete all as specified and directed.
S&F of main control circuit (PCB) suitable for 0.5 KVA to 5 KVA voltage stabilizers complete all as specified and directed.
S&F of output terminal, 32 Amps suitable for 0.5 KVA to 5 KVA voltage stabilizers complete all as specified and directed.
S&F of sensor transformer suitable for 0.5 KVA to 5 KVA voltage stabilizers complete all as specified and directed.
S&F of voltmeter of any shape & size as per existing makes suitable for 0.5 KVA to 5 KVA voltage stabilizers complete all as specified and directed.
S&F of 2–3 minute time delay for low (180V AC) and high (260V AC) voltage cut-offtime suiatble for voltage stabilizers complete all as specified and directed.
Taking out old burnt winding work with and including M&L for re-winding the same with super enameled copper winding wire of existing gauge of 5 KVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed.
Taking out old burnt winding work with and including M&L for re-winding the same with super enameled copper winding wire of existing gauge of 3/ 4 KVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed.
Taking out old burnt winding work with and including M&L for re-winding the same with super enameled copper winding wire of existing gauge of 1/ 2 KVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed.
Transporting refrigerator of any make and capacity from MES store yard to contactor’s workshop for carrying out necessary repair work for its smooth funtioning including depositing back to MES store yard after repair and testing complete all as specified and directed.
S&F of new sealed compressor suitable for refrigerator/ deep freezer of capacity 165 Ltr/ 286 Ltr/ 310 Ltr/ 500 Ltr including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Kirloskar/ Whirl pool/ LG/ Blue star as approved by GE.
S&F of relay suitable for 165/ 286/ 310 Ltrs capacity refrigerator/ deep freezer complete all as specified and directed. Make: INDFOSS/ Godrej/ Whirl pool as approved by GE.
S&F of over load protector suitable for 165/ 286/ 310 Ltrs capacity refrigerator/ deep freezer complete all as specified and directed. Make: INDFOSS/ Godrej/ Whirl pool as approved by GE.
S&F of thermostat suitable for 165/ 286/ 310 Ltrs capacity refrigerator/ deep freezer complete all as specified and directed. Make: INDFOSS/ Godrej/ Whirl pool as approved by GE.
S&F of PVC freezer door suitable for refrigerator of any make & capacity complete all as specified and directed.
S&F of PVC chiller tray of any make and capacity suitable for refrigerator complete all as specified and directed.
S&F of transperant plastic vegetable tray suitable for refrigirator of any make & capacity complete all as specified and directed.
S&F of transperant plastic shelves suitable for refrigirator of any make & capacity complete all as specified and directed.
S&F of magnetic rubber door gasket suitable for refrigerator of any make & capacity complete all as specified and directed.
S&F of freezer temp control fan motor, single-phase suitable for refrigirator of any make and capacity complete all as specified and directed.
S&F of automatic timer box suitable for refrigerator double door of capacity 200/ 310 Ltrs complete all as specified and directed.
S&F of PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified and directed.
S&F of aluminium freezer box/ chiller assembly complete with coil and chamber of any make and capacity suitable for refrigerator complete all as specified and directed.
S&F of fan motor suitable for deep freezer of any make and capacity complete all as specified and directed.
Taking down/out water cooler of any make and capacity from various locations and transporting to contractor’s workshop for carrying out repair work including transporting back to its existing position after repair including testing complete all as specified and directed.
Taking out unserviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade, single phase of 1/8 to 1/35 HP suitable upto 150 Ltr capacity water coolers including testing complete all as specified and directed.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position after testing complete all as directed.
S&F of new hermitically sealed unit compressor for 40/ 80 Ltr capcity water coolers including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Whirl pool/ Kelvinator/ Hitachi/ Electrolux as approved by GE.
S&F of new hermitically sealed unit compressor for 60/ 120 Ltr capcity water coolers including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Whirl pool/ Kelvinator/ Hitachi/ Electrolux as approved by GE.
S&F of new hermitically sealed unit compressor for 150 Ltr capcity water coolers including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Whirl pool/ Kelvinator/ Hitachi/ Electrolux as approved by GE.
S&F of relay & OLP suitable for water cooler of any make & capacity complete all as specified and directed. Make: HI-tech/ Classic as approved by GE.
S&F of thermostat switch suitable for water cooler complete all as specified and directed. Make: INDFOSS/ Godrej/ Whirl pool as approved by GE.
S&F of push taps, brass chromium plated suitable for 150 ltrs capacity water cooler (as per sample) complete all as specified and directed.
S&F of blade of fan motor, size 12" sweep suitable for FHP motor of water coolers complete all as specified and directed.
S&F of PVC flexible pipe transparent 15 mm dia, heavy grade (as per sample) complete all as specified and directed.
S&F of 15 mm bore PVC float valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball complete all as specified and directed.
S&F of running capacitor 4 MFD suitable for water cooler complete all as specified and directed. Make: Epcos or equivalent as approved by GE.
S&F of condenser coil complete with copper tube and aluminium fins for water cooler of any make and capacity as per sample complete all as specified and directed.
Taking down/ out desert cooler of any make and capacity from various locations, transporting to MES store yard and dismantling all unserviceable parts for repair/ overhauling, re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed. Note: Unservicable spare parts will be measured and paid seperately.
M&L for replacement of wood wool pad 15 mm thick made out of chicken wire mesh duly filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed.
S&F of condenser, 3.5/ 4 MFD, 230 Volts for fan motor of desert cooler complete all as specified and directed.
M&L for rewinding of stator of exhaust fan/ kit fan, 18” sweep, 900 RPM of any make with super quality of winding copper wire of existing gauge complete with varnishing, backing, testing including painting with synthetic enamel paint of grey colour complete all as specified and directed.
M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical members fabricated out 22 SWG PGI sheet of size not more than 81.5 x 80.5 x 97.5 cm with double diversion grills and grill box suitable for 18” sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spraying water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 Amps piano type switch and indicator etc complete all as specified and directed.
S&F in replacement submersible water lifting pump of suitable capacity for 1.25 M head, 230 Volts complete all as specified and directed.
S&F of kit fan motor, 450 mm sweep, 1350/ 1400 RPM complete all as specified and directed. Make: Everest/ Summer Cool/ Khaitan as approved by GE.
S&F of PCB suitable for plastic body desert cooler as per sample complete all as specified and directed.
S&F of plastic elbow (3 Nos) and distributer (1 No) for flow of water along three sides of desert cooler complete all as specified and directed.
S&F in replacement polypropylene (PP) filter of RO water purifier complete all as specified and directed.
S&F in replacement 100 GDP membrane for RO water purifier complete all as specified and directed.
S&F in replacement sediment filter of RO water purifier complete all as specified and directed.
S&F in replacement water filter housing of RO water purifier complete all as specified and directed.
S&F in replacement ultra filtration filter of RO water purifier complete complete all as specified and directed.
S&F in replacement ultravoilet choke 12/ 24 V of RO complete all as specified and directed.
S&F in replacement carbon filter of RO water purifier complete all as specified and directed.
S&F in replacement RO SMPS adapter 24 V DC, 2.5 Amp, 240 Volts complete all as specified and directed.
S&F in replacement RO booster pump, 100 GPD, 24 V DC, noiseless, copper winded, corrosion resistant motor pump complete all as specified and directed.
S&F in replacement high pressure switch (HPS), black, 220 V/ 10A (DC&AC) for RO water purifier complete all as specified and directed.
S&F in replacement ultraviolet water purifier sterilizer filter complete all as specified and directed.
S&F in replacement water inlet valve coupling and ball valve set for RO water purifier complete all as specified and directed.
S&F in replacement RO low pressure switch complete all as specified and directed.
S&F in replacement RO float valve switch complete all as specified and directed.
S&F in replacement RO float ball valve complete all as specified and directed.
S&F in replacement PCB (Printed Circuit Board) suitable for Aqua Guard RO water purifier complete all as specified and directed.
S&F in replacement solenoid valve, 24 V, SV high copper for RO water filters complete all as specified and directed.
S&F in replacement 1/4 inch locking clips for RO water purifier complete all as specified and directed.
S&F in replacement 6.35/ 9.50 mm dia polyethylene tubing for RO water purifier complete all as specified and directed.
S&F in replacement 3/8 inchs PVC pump elbow fitting, one side threaded for RO water purifier complete all as specified and directed.
S&F in replacement plastic RO water tap complete all as specified and directed.
S&F in replacement 1/4 inchs PVC elbow connector for RO water purifier complete all as specified and directed.
S&F in replacement 1/4 inch flow restrictor valve (FRV) for RO water purifier complete all as specified and directed.
S&F in replacement TDS controller kit screw switch valve with 2 Pcs T connectors and 2 Mtrs 1/4 Inch Pipe for RO water purifier complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 78022.00
SAMEER ELECTRICAL SUPPLIER (BID ID -3493410)
Raj Contruction (BID ID -3493513)
Neha Enterprises (BID ID -3499566)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_830262.xls
BOQ • 1.11 MB
TENDER_DOCU_8446.pdf
Tender Documents • 0.78 MB
CREDIT8446.pdf
Additional Documents • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .