Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.5 L+₹1.0 L (3.56%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹34.4 L+₹5.0 L (16.9%)Rejected-Finance 0 BINOVA NAGAR KAMRUP ASSAM 781018 UDYAM AS 03 0029196 | KAMRUP METRO | ASSAM | 781018 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Documents not submitted as per NIT and DD not submitted |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
9 Dec 2019, 6:00 pmClosed
GE Narangi
GE Narangi C/O 99 APO Guwahati
PROVN OF STORM WATER DRAIN AND SPL REPAIR TO SAA BURNING PIT AT FAD AND SPL REPAIR TO BLDG. NO T-188 OF HQ CORPS (TAC) AND SPL REPAIR TO TOILET BLOCK AT ABOD UNDER GE NARANGI
2019_MES_296416_1
8503/NAR/E8
Open Tender
Civil Works
Works
180 days
GE Narangi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Narangi
₹63,000
Yes
14 Jan 2020
11 Nov 2019
12 Dec 2019
11 Nov 2019
9 Dec 2019
25 Nov 2019
Amount
Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed.
Removing excavated soil to distance n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point etc complete all as specified and directed.
Demolition of brick or stone masonry work built in cement mortar as in wall including all quoins, arches, pillars etc complete all as directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed.
Demolition of plain cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
Demolition of plain cement concrete (un-reinforced) in ground floors and paving exc 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface etc. complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and directed.
M&L for PCC 1:2:4, type B2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and directed
M&L for 75mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base, floor etc. complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4, type B2 (using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in floor, finished the surface even and smooth using extra cement complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4, type B2 (using 40mm graded stone aggregate) as in path/paving/hard standing/floor and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed
M&L for PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed.
M&L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough etc. including for use of necessary formwork (straight or curved) complete all as specified and as directed.
S&F 3mm thick 38mm width glass dividing strip and inserted in position conform to design complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description or in any position not otherwise specially provided for complete all as specified and as directed.
M&L for Precast RCC 1:1.5:3, type A1 (using 20 mm graded stone aggregate) as in cover slab with plain fair faces including chamfers, weathering and setting in cement mortar (1:6) including form work complete all as specified and directed. Note : Reinforcement will be measured and paid seperately.
M&L for RCC, 1:1.5:3, type A1 (using 20mm graded stone aggregate) as in beams and lintels over 1.5m span complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. in rough finished flat surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cutting cranking, hooking end and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed.
M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St.-240 complete all as specified and directed.
S & F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening complete all as specified and directed.
M & L for rolled mild steel as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) conforming to Fe-410-W(Gde-E-250) completed all as specified and directed.
S & F for 12mm thick mild steel plate, plain or chequered, in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square length of bolt n exc 30 cm long and dia of neck 20mm complete all as specified and as directed.
M&L for loose filling with broken brick aggregates of gauge 80 to 150 mm in soakage pits, soakage wells including taking out old broken brick bats and removing from site complete all as specified and as directed.
Taking down plaster of any description in cement mortar from brick/concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick/concrete surfces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar 1:4, in two layers, under coat of 10 mm thick & top of 5 mm thick, to fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specifed and directed by Engineer-in-Charge. Note : Water proofing compound shall be measured and paid separately as "Supply only.
M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in cement mortar 1:3 on fair faces of concrete surfces as in ceiling, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying three coat of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coat of oil bound distemper over one coat of primer complete all as specified and directed .
M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over one coat of primer complete all as specified and as directed.
M & L for complete removal of old treated surfaces on walls and applying two coats of weather proof exterior acrylic emulsion paint in Camouflage pattern (as directed by Engr-in-Charge/GE) over 1mm thick wall care putty complete all as specified and directed.
M&L for preparation of old decorated wall surface by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
Dismantling of unframed timber scantling 40Sqcm and over in section in any position complete all as specified and directed.
M&L for second class hard wood, in scantlings, clean sawn timber un framed work complete all as specified and directed.
Taking down chowkats with shutters including builders hardware(without taking off shutters from the frame) n.exc. 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each including shutter with builders hardware (without taking off shutters from the frame) complete all as specified and as directed.
Taking down shutter of any description exc 1 sqm but n exc 2 Sqm each including builders hardware complete all as directed.
M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
M & L for 1.25mm thick mild steel pressed steel frames of size 125 mm x 60 mm for doors with single rebates including necessary fixing lugs, 100 mm size mild steel butt hinges, lock strike plate, etc complete all as specified and directed.
S & F 30 mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S & F 35 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (with out sash bar), edges of framing with plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 30mm thick second class hard wood, glazed and skeleton shutters, open rebated divided into square and prepared to receive glass, gauge etc (with sash bar of any number), edges of framing with plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
S & F PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F for factory made EPS core solid PVC door shutter with wood free EPS board 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on front face and 2mm plain colour PVC sheet on back face. The door on all the edges to be sealed with lipping of 10mm (5mm x 2) thick X25mm wide PVC sheet for 3 sides and 60mm wide PVC sheet for lock side. The lipping shall be bonded to the 2mm moulded / plain PVC sheet with solvent cement complete all as specified and directed.
S & F mild steel butt hinges 100mm size, cold rolled, medium weight complete all as specified and as directed.
S&F mild steel butt hinges 75mm size, cold rolled, medium weight complete all as specified and as directed.
S & F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S & F 125 mm in size aluminium handles, cast type, anodised complete all as specified and directed.
S & F 100 mm in size aluminium handles, cast type, anodised complete all as specified and directed.
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S & F mild steel flat iron hold fasts fixed to chowkats confirming to Fe-310-O etc, complete all as specified and directed.
S & F second class hard wood small fittings such as brackets of any type, latch and hinge blocks shaped door and window stops and the like including all necessary labours, articles not exceeding 200 cu.cm each complete all as specified and directed.
S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or aluminum wire staples complete all as specified and directed.
S & F in repair stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or aluminum wire staples complete all as specified and directed.
Hacking out old broken glass of any thickness, size quality or description from wooden frames glazed with putty or fixed with bead complete all as specified and as directed.
S & F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed..
S & F 3 mm thick frosted sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50sqm in each pane complete all as specified and directed.
M&Lfor preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, not otherwise described exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of old wooden surface over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treating with two coats of creosote oil complete all as specified and directed.
M & L for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed.
M & L for coloured non skid cermic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layers in cement mortar (1:6) complete all as specified and as directed..
M&L for glazed ceramic coloured tiles of size 300 mm x 200 mm x 7 mm thick on vertical surfaces set, jointed and pointed in net cement slurry and pointed in white cement mixed with colour pigments to match the existing surface over and including 10mm thick rendering in CM 1:4 complete all as speciified and directed.
M&L for glazed ceramic coloured tiles of size 300 mm x 450 mm x 7 mm/300 mm x 600 mm x 7 mm thick fixed in verticle surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:4 complete all as speciified and drected.
Demolition of stone slab and tiles of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified and directed.
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F in repairs for pre polished chequered cement concrete tiles area exc .06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 15 mm thick cement mortar (1:4) for laying floor finishes complete all as specified and directed.
S & F in repairs, GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repairs, GI tubing 20 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M & L for cutting chases in brick wall for concealed pipe where required and pointing in cement mortar 1:3 etc. complete all as specified and directed.
S & F in repairs bib taps 15 mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15 mm bore pillar taps, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S & F in repairs 15 mm dia of stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed
S & F in repairs 15 mm dia of concealed stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed
S & F in repairs tubular towel rail of 20mm dia and 60cm in length, D shaped, with brass chromium plated brackets complete all as specified and directed.
S & F in repairs Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
S & F in repairs, 500 litres capacity rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed.
S & F in repairs 20mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with cruth or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repairs vitreous china wash hand basin, white flat back size 550 mm x 400 mm including brackets including pillar tap 15 mm bore chromium plated cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe complete all as specified and as directed.
S & F vitreous china squatting pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed
S & F in repairs vitreous china bowl urinal flat back, size of 465 mm x 355 mm x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed
S & F in repairs 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets etc complete all as specified and directed.
Demolition and breaking up drain pipe SGSW/CI/PVC pipes of 110/150mm dia from trenches including cement concrete haunching etc complete all as specified and directed.
S&F 150mm dia PVC (SWR) pipes, having pressure rate 6 Kgf, single socketed in any length with rubber ring joints and laid in trenches as in waste/soil pipe complete all as specified and as directed
S&F 110mm dia PVC (SWR) pipes, presure rate having 6 Kgf single socketed in any length with rubber ring joints and laid in trenches as in waste/soil pipe complete all as specified and as directed.
M&L for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested for 150mm dia complete all as specified and as directed.
M & L for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested for 110mm dia complete all as specified and as directed.
S&F 75mm Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors with all fittings and fixed as in spout pipe complete all as specified and as directed.
Dismantling PVC drain pipes any size and in any position including all fittings complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall as in waste/soil pipe complete all as specified and as directed
S&F 75 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
S&F 75 mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and directed.
S&F 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC flexible connections 15 mm dia 600 mm long with brass check nuts complete all as specified and directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 with mixing of WPC @ 3% weight of cement or as per manufactuers instructions and surface finished fare and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
Taking down carefully any type of point wiring (light, fan, bell socket or power), complete excluding fittings such as DBs etc. but including switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including casing caping on walls/ceiling, and also including sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers for One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) in and including casing caping on walls/ceiling, and also including sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) in and including casing caping on walls/ceiling, and also including sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers for One 5 Amp, 3 pin switch socket outlet on same board complete all as specified and directed.
M & L for point wiring with 4 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) in and including casing caping on walls/ceiling, and also including sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers for 6 pin, 15 Amp, switch socket combination outlet on independent board complete all as specified and directed.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp, flush type complete all as specified and directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp, flush type, complete all as specified and directed.
S&F lamp holder insulated,PVC/polycarbonate /bakelite body complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as specified and directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S & F LED box type fitting pre-wired including LED tube 1x20W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and directed. Make- Havells Cat No ENDURALINEARNEOBS20WLED865SPCWH or Surya Cat No SLE BTN T8 20W or Crompton Cat No LDLSR20-WW or equivalent model of make Philips/Bajaj
S&F in repairs, decorative hexagonal bulk head LED luminaire 10 Watt, 6000K with IP 66 protection complete all as specified and directed. Make- Havells Model- HEXAFT10WLED857SSYMBOPC or equivalent model of make Philips/Bajaj /Crompton.
S&F single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar 230 volts grouted in wall with PCC 1:2:4, type B1, using 20 mm graded stone aggregates complete all as specified and directed. Make :- Legrand Cat No 6077 11 or equivalent model of make Siemens/Schnider
S&F MCB, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed. Make :- Legrand Cat No 4085 87 to 4085 95 or equivalent model of make Siemens/Schnider.
S&F MCB, SPN 40 to 63 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed. Make :- Legrand Cat No 4086 18 to 4086 20 or equivalent model of make Siemens/Schnider
M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
M/S SHARMA CONSTRUCTION
KAMAKHYA CONSTRUCTION AND BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .