Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC lowest | |
| 2 | L2₹18.2 L+₹67,385 (3.84%)Rejected-AOC | L2 | Rejected-AOC not found lowest | |
| 3 | L3₹19.2 L+₹1.6 L (9.37%)Rejected-AOC | L3 | Rejected-AOC not found lowest | |
| 4 | L4₹19.4 L+₹1.8 L (10.2%)Rejected-AOC GOVT CONTRACTOR VILL NAYA SUJAN FEROZPUR KALAN TEH DIST PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L4 | Rejected-AOC not found lowest | |
| 5 | L5₹19.4 L+₹1.8 L (10.4%)Rejected-AOC | L5 | Rejected-AOC not found lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
17 Jun 2022, 6:00 pmClosed
GE Basoli
GE Basoli PO lakhanpur Distt Kathua JK
REPAIR AND MAINTENANCEOF SECURITY LIGHTS, ROAD LIGHTS, SOLAR LIGHTS AND STAND BY GENERATOR SETS AT MADHOPUR STATION UNDER GE BASOLI
2022_MES_525618_1
GE/BAS-17/2022-23
Open Tender
Civil Works
Item Rate
180 days
Madhopur area under GE Basoli
class E Catg b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Basoli
₹40,000
Yes
29 Dec 2022
23 May 2022
20 Jun 2022
23 May 2022
17 Jun 2022
10 Jun 2022
Amount
Repair / rectification for street light/ perimeter light/ flood light any type, capacity & make, to make the security / street lights in serviceable condition as intimated by JE EM/ Engineer-in-Charge after rectification/ tracing out the fault which includes removing of street/ security light fitting from LT Steel tubular/PCC poles/ Swan neck poles, refixing after repair, tightening of loose connection in ACSR conductor / with bus bar chamber / in DB, replacement of lamp, lamp holder, capacitor, replacement of connection wire not less than 1.5 sqmm or any other part and re-fixing in proper alignment on GI Pipe bracket or by other means as per site requirement including replacement of screws, nuts , bolts washers as required, proper connection with PVC insulation tape etc complete to keep the light in serviceable condition throughout the period of contract by repairing on time all as directed to the entire satisfaction of Engineer-in-Charge Note:- (i) Worn out / damaged/ Unserviceable parts to be replaced shall be measured and paid for separately under relevant items of Sch " A' as supply only and fixing is deemed to be included under this item. (i) All the T&P and transportation required for the work shall be arranged by the contractor which shall be deemed to be included in quoted rate. Contractor shall provide the all type of T&P i.e. tools, insulation tape, ladder any type etc to electrician for attending the complaints. The quoted rate include the cost of minor items i.e. screws, nuts, washers for light fitting etc. (ii) The work will be carried out on at as per direction of JE/ Engr-in-Charge. (iii) An inventory for the parts/ spares which are found unserviceable and require replacement with new parts/ spare shall be prepared and kept in record duly signed by Engineer-in-Charge and Contractor. detail shall be maintain with signature of JE EM , Engineer-in-Charge and Contractor. In case of any discrepancies the decision of accepting officer shall be final and binding.
Supply only and replaced under the item No.1 Driver electronic compact type suitable for LED street light fitting 45 Watt as per sample/required at site complete all as specified and directed.
Supply only and replaced under the item No.1 Driver electronic compact type suitable for LED street light fitting 60 Watt as per sample/required at site complete all as specified and directed.
Supply only and replaced under the item No.1 Driver electronic compact type suitable for LED street light fitting 90 Watt as per sample/required at site complete all as specified and directed.
Supply only and replaced under the item No.1 LED Street Light bulb threaded type of capacity 30 Watts complete all as specified and directed.
Supply only and replaced under the item No.1 LED Street Light bulb threaded type of capacity 40 Watts complete all as specified and directed.
Supply only and replaced under the item No.1 porcelain Lamp holder suitable for 30/40 watt LED Lamp fitting thread type complete all as specified and directed.
Supply and fix in repair / replacement LED street light fitting of capacity 45 Watt energy saving & environmental friendly long life versatile pressure die cast aluminum with protection IP66 and impact resistance of IK07 with high power LEDs as light source with electronic chip and driver (lamp type 45W LED) efficacy 100 Lm/W 5700 K suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement LED street light fitting of capacity 60 Watt energy saving & environmental friendly long life versatile pressure die cast aluminum with protection IP66 and impact resistance of IK07 with high power LEDs as light source with electronic chip and driver (lamp type 60WLED) efficacy 100 Lm/W 5700 K suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement LED street light fitting of capacity 35 Watt energy saving & environmental friendly long life versatile pressure die cast aluminum with protection IP66 with high power LEDs as light source with electronic chip and driver (lamp type 35WLED) efficacy 100 Lm/W 5700 K suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed ,
Supply and fix in replacement flood light of capacity 45 Watt energy saving & environmental friendly long life versatile pressure die cast aluminum with protection IP66 made out pressure die cast aluminum housing suitable lens & toughened glass with high power LEDs as light source with electronic chip and driver with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement flood light of capacity 50 Watt energy saving & environmental friendly long life versatile pressure die cast aluminum with protection IP66 made out pressure die cast aluminium housing suitable lens & toughened glass with high power LEDs as light source with electronic chip and driver with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix in replacement flood light of capacity 60 Watt energy saving & environmental friendly long life versatile pressure die cast aluminum with protection IP66 made out pressure die cast aluminum housing suitable lens & toughened glass with high power LEDs as light source with electronic chip and driver with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed.
Supply and fix replacement of three core copper conductor multi-stranded type PVC insulated and sheathed of 2.5 sqmm, 1100 volts grade and connected to the street light from over head line or Junction boxes complete all as specified and directed
Supply and fixing in replacement PVC conduit 25mm dia medium grade for fixing along the pole with 02 Nos clamps per pole the connections from junction box to street lights all as specified and directed.
M&L for supply and fixing new MS poles in replacement of existing unserviceable Steel tubular swaged poles, complete with cast iron plate, bolt, nuts & screws as specified type 410 SP-31 (09 mtr long) with 250mmx250mmx6mm mild steel plate continuously welded to Pole, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats black bituminous paint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30cm high with super enamel paint (Black and Yellow/white) from ground level/coping, up to 1.5M painting with two coats of aluminum paint for the remaining height complete all as specified and directed. Note:- Excavation, earth work and PCC in coping/foundation shall be measured and paid for separately.
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly, complete all as specified and as directed.
Supply and laying, replacement in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 10 sq mm X 2 core stranded conductor, complete all as specified and directed.
Supply andlaying, replacement in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 10 sq mm X 4 core stranded conductor, complete all as specified and directed.
Supply and laying, replacement in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 16 sq mm X 2 core stranded conductor, complete all as specified and directed.
Supply and laying, replacement in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 16 sq mm X 4 core stranded conductor, complete all as specified and directed.
Supply and laying, replacement in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 25 sq mm X 3.5 corestranded conductor,complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5 mtr deep and getting out in any type of soil complete all as specified and directed .
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. NOTE :- Punned thickness shall be measured.
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.
Supply and fix in replacement for junction box of size 300x250x150mm made out of 1.6 mm thick CRCA sheet powder coated front hinged door with openable and self closing arrangements including aluminium bus bar 3 Phase 4 wire system of size 20mm x 5mm fixed on SMC/DMC insulators and cable entry glands for connections and MCB SP 6 Amps-01 No all as required and fixed to poles with MS clamp made out of MS flat iron of size 25x5mm and including nuts, bolts and washers complete all as specified and directed.
S&F in replacment of smart integrated solar street light LED with built in mono crystalline panel, litheium ferro phosphate battery MPPT charge controller and PIR Sensor with colour temperature 6000 to 6500 K capacity 15 W all in one standard complete.
Supply and fix in replacement Off load change over switch four pole with sheet metal enclosure of capacity 100 Amps , 415 Volts,Ac with necessary nuts, bolts and washers including necessary electric connections incl taking down all as specified and directed
Supply and fix in replacement Off load change over switch four pole with sheet metal enclosure of capacity 63 Amps , 415 Volts,Ac with necessary nuts, bolts and washers including necessary electric connections incl taking down all as specified and directed
S&F in structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, including taking down old corroded structural steel all as directed.
Comprehensive maintenance and repair of diesel engine of DG sets 63 KVA capacity installed at various locations, by periodical servicing maintenance as per OEM and BOO recommendations, repair including replacement of defective/ unserviceable spare parts, tracing & removing of any fault/error indication or meassage showing/ indicating on display screen, greasing to doors/ over hauling to various parts, cleaning of DG set, inspecting the serviceability of all parts and testing on full load after periodical service/ repair by manufacturer's authosied workshop , complete all as specified and as directed. (Spare Parts shall be measured and paid for seperately under respective items and shall be replaced on recommandations of BOO. The maintenance of above mentioned DG sets carried out will be measured as one unit)
All as per Srl Item No 33 above but DG Set of 40 KVAcapacity complete all as specified and as directed by Engineer-In-Charge (Note: The maintenance of above mentioned DG set carried out will be measured as one unit)
Notes for Sr Item No 33 to 34:- The BOO will examine the DG set at the time of opening of DG set by approved firm engineer or trained mechanic by the approval of GE, the following shall be covered as under :- (i) New spare parts and engine oil shall be measured and paid separately under respective items. (ii) Labour charges for replacement of old engine oil and old defective spare parts shall be deemed included in quoted rates. (iii) Cost of routine lubrication/ greasing to spare parts, lubricants/grease, tightening of nut, bolts and washers etc. shall deemed included in quoted rates. (iv) Cost of fixing and transportation of all components/ spare parts required being repair, of DG sets from site to workshop for repair and workshop to site after repair shall be deemed included in quoted rates. (v) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per TI-04 of 1984 and maintenance record, prepared/ maintained by contractor and signed by concerned JE E/M, Engineer-In-Charge and Contractor. This maintenance record shall be produce to Garrison Engineer whenever asked. (vi) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per following periodicity: a) Stage-I (Monthly): (i) Cleaning of air cleaner/ filter. (ii) Changing of lubricants and oil filter elements. (iii) Cleaning of fuel tanks and cleaning of fuel filter elements. (iv) Cleaning of radiator cooling fins and top up of coolant. v) Cleaning of line cylinder head fins, in case of air cooled engines. (vi) Checking of all electrical instruments/indicating or any other gauge i.e. frequency meter,voltmeter, ammeter, revolution meter, Hrs run meter, water temp gauge, fuel gauge etc for satisfactory functioning. (b) Stage-II (Quarterly): (i) Changing of engine oil, if required, and clean the pre-cleaner bowl. (ii) Check/ open radiator fins, and clean, if chocked/ blocked. (iii) Check button filter in banjo bolt of feed pump. (iv) Drain the water from water separator, if provided. (v) Check all external fasteners as per specified torques. (vi) battery lead connections. (vii) Check belt alignment and belt condition. (viii) Check turbo changer. (ix) Leakage in air take/ exhaust of exhaust piping (x) Lubrication to the turbo charger,Oil filter. (xI) Cleaning of fuel tank of any capacity for DG set 40 KVA to 63KVA any type(inbuilt in canopy/ separate storage tank) DG Set by removing all silt /dirt/ all residual, foreign particles any type etc, removing any type of leakage by welding/brazing and writing date of cleaning with synthetic enemel paint.
Replacement of existing Unserviceable parts with new parts (fixing shall be paid against Srl item No. 34 of DG set 63/62.5 KVA a) Fuel Filter
(b) Oil filter
( c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
(f) Air filter
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 35 of DG set 40KVA (a) Fuel Filter
(b) Oil filter
( c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
(f) Air filter
Replacement of old damaged battery lead with new battery lead of copper conductor of 50 Sqmm cross-sectional area, multistranded, single core, PVC insulated fitted with lugs/ terminals at one end and brass terminals at other end, complete all as specified and as directed. (Note: The battery lead replaced shall have colour as per colour coding. The brass terminal provided on battery end side shall be measured & paid separately.)
Taking out old defective repairable injection nozzle from existing DG set of 63/62.5 KVA capacity and transport to workshop for any type of repair, overhauling and calibration including installation back to same DG set, including testing, complete all as specified and as directed.
All as per Srl Item No 33 above but DG Set of 40 KVA capacity complete all as specified and as directed by Engineer-In-Charge.
Supply only coolant fluid of make as approved by GE suitable for radiator of DG set of any capacity/make shall be top up during compreahansive serviceing as per recommandations of BOO, complete all as specified and as directed .
Supply only Engine oil/ lubricant, 20 W 40 grade or any other grade as recommended by OEM of Engine or BOO suitable for DG set of any capacity and any make, shall be top up during compreahansive serviceing, complete all as specified and as directed.
Taking out FIP from DG set of 63/40 KVA capacity, transportation to manufacturer's authorised service centre and recallibration & transpotation to same or other location as directed incl. replacement of all necessary spare parts such as delivery valves , plunger , 'O' ring spring etc complete all as specified and directed.
Repair and maintenance of DG set control panel, checking all the electrical connections of engine/alternator/ control panel instruments ie lub oil, pressure gauge,temprature gauge, ameter, battery , volt meter,ac volt meter,ac ameter, frequecny meter etc, calibration of modules microprocessor, tightening all the connection, replacement of defective wiring & cable and lugs of DG set of cap 40KVA to 63KVA DG set and replacing of the following parts as under :-
Voltmeter digital/analog type 96x96mm having range as per existing
Ammeter digital/analog type 96x96mm having range as per existing
Replacement of battery 12 volt, 150 AH heavy duty maintenance free including initial charged complete in all respects. Make Exide
Earthing complete with G.l earth plate electrode 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore including 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Supply and fixing in replacement aluminium conductor steel re-inforced (ACSR) Ferret/of size 6/1x3.00 mm /of size 6/1x2.59 mm (weasal) and 6/1x2.11 mm of . for LT lines on concrete poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and directed.
Supply and fixing in replacement of street light brackets and Light grade GI pipe 40mm dia and length 1.5 m , bend to shape at 120 degree and welded as required inclufing MS flat iron clamps, bolts, washers and nuts including painting clamps with primer and two coats of aluminium paint, complete all as specified and as directed.
S&F DWC high density polyethelene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed.
Standard engineers
G.M. ENGINEERING SERVICES
BALKRISHAN GUPTA AND SONS
KALSI CONSTRUCTION CO
M/S SURINDER KUMAR MAHAJAN
M/s. Jaswant Singh Govt Contractor
DASHMESH BUILDERS
Ms International Engineers
Om Sai Ram Builders
Substantial Const. Co.
m/s pankaj soni
R K Builders
Ms Narinder Kumar Sehgal
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .