Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 CrAccepted-AOC | ₹21.3 Cr | L1 | Accepted-AOC OK |
| 2 | L2₹23.5 CrRejected-AOC | ₹23.5 Cr | L2 | Rejected-AOC OK |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive as per Cl Section 2 4.2(f) |
| 4 | Rejected-Technical BALUMATH LATEHAR | LATEHAR | JHARKHAND | 822111 | - | - | Rejected-Technical Non Responsive as per Cl Section 2 4.2(a) |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non Responsive as per Cl Section 2 4.2(a) |
Tender Value
₹22.4 Cr
EMD Value
₹44.8 L
Closing Date
22 Mar 2024, 5:00 pmClosed
CE, JSRRDA
JSRRDA, 3RD FLOOR, FFP BUILDING, DHURWA, RANCHI
Construction and Maintenance of Roads
2024_CEJHR_132983_1
JH-P3-23-24-KHU-02
Open Tender
Civil Works - Roads
455 days
KHUNTI
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
₹44.8 L
24 Aug 2024
16 Mar 2024
22 Mar 2024
16 Mar 2024
22 Mar 2024
16 Mar 2024
Amount
Details
Road-1 (T07-RUGRI TO GORATOLI IN MURHU (KHUNTI CHAIBASA MAIN ROAD NH-75E) VIA KOLME, CHICHIGARHA, HETHGOA) Setting out etc all complete job as per specification and directioni of E/I
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical specification Clause 201.
Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. SOR 3.2
Dismantling of Cement Concrete Pavements as per Technical Specification clause 202 Dismantling of Pavement by mechanical means using pneumatic tools breaking of pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000m, stacking serviceable and unserviceable materials separately. SOR NO.2.15
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. ( Dismantling of cement concrete)
Dismantling of Rubble masonary/Brick masonary in cement mortar Vide SOR 2.6/2.7 (B)
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. up to 600mm
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. up to 600mm to 900mm dia Hume pipe
Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Compacting original ground supporting subgrade: Loosening, of the ground upto level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of of Tables 300.1 and 300.2 for subgrade construction as per Technical Spe
Construction of embankment with approved material obtained from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 Qty (Free Lead)
Construction of embankment with approved material obtained from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (Lead upto 250m))
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. GRADING-I
Wet Mix Macadam (WMM) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Providing and applying Primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification
Providing and applying Tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared non-bituminous surfaces (cement concrete pavement) cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing and laying bituminous macadam (BM) with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,clause1501 of MoRD SOR NO. 6.4
ROAD FURNITURE Providing and fixing of typical PMGSY informatory Sign Board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick top and middle plate duly welded with MS flat iron 25mmx5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mmx25mm x5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm x 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All MS will be stoe enameled on both sides. Lettering and printing arrows, border etc will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy as per drawing. SOR NO. 10.16
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing
Providing and fixing of retro- reflectorised cautionary, mandatory and Traffic Sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing
Reinforced cement concrete M-15 grade 5th Kilometer stone (Precast)/Local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) stone/Local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703. SOR NO. 10.10
Reinforced cement concrete M-15 grade 200m stone (Precast) stone/Local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Boundary pillar: Reinforced cement concrete M-15 grade boundary pillars/Local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 704. (Boundary pillar/ FI Post)
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surface as per drawing and Technical Specification Clause 1701 SOR NO. 10.5
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810
Painting of hazardous objects like electric pole etc all complete job as per specification.
Painting of hazardous objects trees etc all complete job as per specification and direction of E/I
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. Zebra Crossing
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-C Type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. Temple/Mosqe and other religious place
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-C Type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. School
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-C Type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.Village Board
DRAIN Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (SOR 14.5)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (SOR 12.5) PCC 15 (1:2:4)
Stone masonry in cement mortar for foundation & Plinth complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 (SOR 11.6)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (SOR 12.5) PCC 15 (1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204.
Providing and laying reinforced cement concrete in superstructure as per drawing Deck Slab (M25) (50% of Drain covered by Slab).
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 (SOR 13.3)
Protection Work Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 including setting out,construction of shorting and bracing, removal of stumps and other deleterious matte, dressing of sides and bottom and backfilling with approved material. SOR NO, 11.1
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 PCC Grade M-15 SOR NO. 12.5
Stone masonry in cement mortar (1:4) random rubble masonry for foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 SOR NO.11.6
Stone masonry in cement mortar (1:4) random rubble masonry for superstructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 SOR NO. 13.17
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 PCC Grade M-15 SOR NO. 12.5
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 SOR 12.9
Pointing with cement mortar (1:3) :-- Pointing with cement mortar (1:3) on Stone Masonry work as per drawing and technical specification Clauses 613.3 and 1204
HUME PIPE CULVERT 1nx1m dia Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing M10 (PCC 1:3:6) as levelling course in foundation :-- Providing PCC M 10 (1:3:6) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Providing and laying 1000 mm Dia RCC pipe NP-3 for culverts on first class bedding of PCC M10 (1:3:6) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works,backfilling concrete and masonary works in head
Pointing with cement mortar (1:4 ) on brick work in sub-structure as per Technical Specifications
R C C Culvert 1nx1.5mx1.5m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parrapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Pointing with cement mortar (1:4 ), 15 mm Thick on brick work in sub-structure as per Technical Specifications Clause 613.4 & 1204.
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
R C C Culvert 1nx2mx2m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
RCC Culvert 1nx3mx2m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
RCC Culvert 1nx6mx3m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
RCC Culvert 1nx6mx4m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
Stone masonry work in cement mortar in foundation (1:4) Rubble complete job as per drawing and technical specification clauses 702, 704, 1202 & 1203. . no. 11.6 (III) (ii)
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specification clause 802, 803, 1201 & 1203. (11.4 (ii) PCC Grade M-15
Plastering with cement mortar (1:4) 15mm thick on stone work in parapet as per technical specifications clause 613.4 abd 1208.4 SOR 13.19)
MAINTENANCE For 1st Year
For 2nd Year
For 3rd Year
For 4th Year
For 5th Year
T07-RUGDI TO GODATOLI, MURHU (KHUNTI-CHAIBASA MAIN ROAD NH-75E) VIA KOLME, CHICHIGARA, HETHGOBA ROADEarthwork in excavation of foundations for structures including all leads and lifts complete as per drawings and MORT&H specifications clause 304.(a) In all types of soil
Earthwork in excavation of foundations for structures including all leads and lifts complete as per drawings and MORT&H specifications clause 304.(b) In soft/ordinary rock
Providing & laying filter media behind abutments, wing walls, return walls and box structures with well packed material to the specified thickness with smaller size towards the soil and bigger size towards the wall complete with all leads and lifts as per drg. and MORT&H specifications clause 305 and clause 710.1.4 of IRC:78.
Providing & laying plain cement concrete / Reinforced Cement Concrete in foundations / levelling course including form work but excluding the cost of reinforcement complete as per drg. and MORT&H specifications sections 1500, 1700 and 2100.a) M-10 grade
Providing & laying plain cement concrete / Reinforced Cement Concrete in foundations / levelling course including form work but excluding the cost of reinforcement complete as per drg. and MORT&H specifications sections 1500, 1700 and 2100.d) M-30 grade
Providing & laying plain cement concrete / Reinforced Cement Concrete in sub-structure including form work but excluding the cost of reinforcement complete as per drg. and MORT&H specifications sections 1500, 1700 & 2200.d) M-30 grade
Providing & laying Reinforced Cement Concrete in super-structure including form work but excluding the cost of reinforcement complete as per drg. and MORT&H specifications sections 1500, 1700 & 2300.ii) M-30 grade
Supplying, placing and fixing TMT/HYSD bar reinforcement complete as per drg. and MORT&H specifications section 1600.a) For sub-structure
Supplying, placing and fixing TMT/HYSD bar reinforcement complete as per drg. and MORT&H specifications section 1600.b) For super-structure with Crash Barrier/Railing
Supplying, placing and fixing TMT/HYSD bar reinforcement complete as per drg. and MORT&H specifications section 1600.c) For foundations
Supply & fixing of bearings complete as per drg. and MORT&H specifications section 2000.b) Elastomeric bearing
Providing & fixing of expansion joints complete as per drg. and MORT&H specifications section 2600
Providing & fixing drainage Spouts complete as per drawing & MORT&H Specifications Clause 2705.
Providing & laying 75mm thick wearing course of M30 Concrete as MORT&H specifications section 2700.
Providing cement concrete railing in M-25 grade including form work and reinforcement complete as per drawing & MORT&H Specifications sections 1500, 1600, 1700, 2200 & 2703.
Providing & laying plain cement concrete in levelling course under the approach slab complete as per drg. and MORT&H specifications sections 1700, 2100 and 2700.a) M-15 grade
Providing & laying reinforced cement concrete in approach slab including form work and excluding reinforcement.a) M-30 grade
Providing & laying filter material underneath stone boulder pitching on slopes complete as per drg. and MORT&H specifications section 2500.
Providing & laying stone boulder pitching on slopes with cement mortar filled joints in 1:3 (1 cement : 3 coarse sand) complete as per drg. and MORT&H specifications section 2500.
Providing weep holes in brick masonry / plain / reinforced concrete abutments, wing walls / return walls etc. with 100mm dia A.C. pipe, extending through the full width of structure with slope of IV:20H towards draining face complete as per drg. and MORT&H specifications clause 2706.
Painting of Bridge No. and span arrangement as per drg., IRC:7-1971 and MORT&H specifications section 800.
Confirmatory Boring (in Rock)
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.
PMGSY Logo
Boundary Pillar
GUARD WALLE/W in excavation of foundation trenches do-do-all complete job as per specification and direction of E/I
Providing P.C.C.M15 with nominal mix (1:2:4) in foundation -do-do-all complete as per specification and direction of E/I
Providing R.D.R.R. Stone masonary with c.m.(1:3) in foundation -do-do- all complete
Providing R.D.R.R. Stone masonary with c.m.(1:3) in substructure -do-do- all complete
Providing P.C.C.M20 in substructure -do-do- all complete
providing Filter media -do-do- all complete
APPROACH ROADClearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.By Manual Means
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For grading- II Material
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.WMM
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.BM
Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respectsBC
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.30 to 0.35 kg per sqm on the prepared non-bituminous surfaces (cement concrete pavement) cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 1.2-1.5 kg/sqm using mechanical means as per Technical Specification Clause 502.
DIVERSION ROAD & DISMANTLINGClearing and Grubbing the road land,(Clearing and grubbing the road land including uprooting rank vegetation,grass,bushes,shrubs,saplings and trees girth upto 300mm ,removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of sercviceable materials to be used or auctioned upto a lead of 1000 mts. including removal and disposal of organic soil not exceeding 150mm in thickness.
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m (including royality @ Rs. 24.00 per cum , watering, rolling & compaction)
Construction of embankment with approved material obtained fromborrow pits with all leads and lifts ,trasporting to site ,spreading ,grading to required slope and compacting to meet requirement of table300-2 including cost of watering ,rolling and compaction all complete as per specification and direction of E/IRolling with vibratory Roller
Construction of embankment with approved materials deposited at site from road way cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2 including cost of watering ,rolling and compaction all complete as per specification and direction of E/IRolling with vibratory Roller
Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.
Providing stone metal Gr-II( 63mm to45 mm size) with crushable type screening material in road embankment -do-do- all complete job as per specification and direction of E/I
Providing stone metal Gr-III( 53mm to 22.4 mm size) with crushable type screening material in road embankment -do-do- all complete job as per specification and direction of E/I
Providing and applying primer coat with bitumen emulsion on prepared surface of granular base including clearing of the road surface and spraying primer @0.60 kg/sqm using mechanical means . As per MOSRT&H specification 502 (4th revision ) & as per direction of E/I.
Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades.
Maintaining the Diversion during construction period as and when required all complete job as per specification and direction of E/I
E/W in excavation of foundation trenches in ordinary Soil -do-do-all complete job as per specification and direction of E/I
Providing P.C.C. M15 with nominal mix (1:3:6) in foundation trenches and plinth -do-do-all complete job
Providing R.D.R.R stone masonary with c.m.(1:3) in foundation and plinth -do-do- all complete as per spn.
Providing P.C.C. M15 with nominal mix (1:2:4) in Substructure -do-do-all complete job
Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets .
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres(i)R.C.C. by mechanical means
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres(ii) Masonary work in C.M.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres(iii) PCC
First Year
Second Year
Third Year
Fourth Year
Fifth Year
Labour Cess @ 1%
Satyendra Kumar Construction Pvt Ltd
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid