Sr. Mgr. E and M
Samrat Hotel, 50B, KautilyaMarg, Chanakyapuri, New Delhi-110021
Supply and fixing of chilled water Pot Strainer and Cooling Tower of D.G set at Hotel Samrat, New Delhi.
2026_ITDC_295353_1
Engg/EM/PS/CT/26-27
Open Tender
Miscellaneous Works
Works
120 days
New Delhi
As per tender document
21 documents required · 21 mandatory
₹0
₹25,600
31 Oct 2026
23 Oct 2026
31 Oct 2026
23 Oct 2026
30 Oct 2026
23 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, Testing and commissioning of Pot Strainer FOR 350mm dia pipe line of chilled water system of AC plant, Top cover and main body shell fabricated with M.S plate as confirming IS 2062 or 251 (New Grade ), SS 304 basket 18 gswg with 3mm perforation, Inlet outlet pipe connection with ERW "C" confirming to IS: 1239 PART-1,BS- 10 table E flanges, Overall Size D: 920mmx H: 955mm. | 1 | No. | - | - |
| 2Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes up to 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. | |||||
| 2.01 | Condenser water piping of nominal size -150mm dia | 12 | Mtr. | - | - |
| 3Supplying, Fixing, testing and commissioning of following valves gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile sheet & O-Ring PN 16 pressure rating as specified. | |||||
| 3.01 | 350 mm Dia | 2 | Nos | - | - |
| 3.02 | BUTTERFLY VALVE (MANUAL) of 150 mm dia | 4 | Nos | - | - |
| 4 | Supplying, installation, Testing and commissioning of Induced draft FRP cooling Tower 3750 LPM, Cap 2249755 Kcal/Hr as per below specifications:
a) Hot Water Temperature 42°C, Cold Water Temperature 32°C, Cold Water Temperature 32°C
b) Design Wet Bulb Temperature 28°C, Range 10°C, Approach 4°C
c) Heat Rejection Capacity 2249755 Kcal/Hr
d) Evaporation Loss 1.53 %
e) Number of Fans 1 No. Diameter 2100, Fan Speed 570 RPM
f) Motors- 1 No, Squirrel Cage Induction Motor, Enclosure TEAO Weather-Proof (IP 55)
g) Motor Rating 12.5 HP / 570 RPM, Efficiency Class IE2, 415V / 3Ph / 50Hz, Insulation Class F
h) Electrical Characteristics
i) Basin FRP Material Drift Eliminator PVC ‘C’ Type Fill Type PVC, Honey Comb, Cross Fluted.
j) Bolt, Nuts & Washers HDGMS, Ladder Galvanized Iron. | 1 | No. | - | - |
| 5Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expanded polystyrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing etc. as per specifications and as required complete in all respect. | |||||
| 5.01 | Insulation with Expanded polystyrene of thickness 50mm on existing pipe. | 7 | Sqm. | - | - |
| 6 | Dismantling/removing and buy back of the existing Pot Strainer FOR 350mm dia pipe line of chilled water system of AC plant | 1 | No. | - | - |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_344269.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .