Pre-bid Tie up of COMPRESSED AIR SYSTEM for 4X700 MW ASHVINI MAHI BANSWARA UNIT 1-4 Nuclear Island Mega EPC Package (NIMEP).
2026_BHEL_65404_1
77/26/6158/SAN
Open Tender
Mechanical Tools and Equipment
Lump-sum
900 days
Banswara
Refer NIT for PQR and NDA
4 documents required · 4 mandatory
₹0
₹40 L
Yes
17 Oct 2026
28 Sept 2026
17 Oct 2026
28 Sept 2026
17 Oct 2026
28 Sept 2026
Total lump sum firm price for Supply part, Services part, Mandatory Spares and Engineering Charges comprising of design (i.e. preparation and submission of drawing /documents including “As Built” drawings and O&M manuals), engineering, manufacture, fabrication, assembly, inspection / testing at vendor's & sub-vendor’s works, painting, maintenance tools & tackles (as applicable), fill of lubricants & consumables, nameplates, mandatary spares along with spares requried for erection, start-up spares and commissioning spares, forwarding, proper packing, shipment and delivery at site, in-site transportation, unloading & handover to BHEL, supervision of erection & commissioning, trial run at site and carrying out Performance guarantee tests at site, training of BHEL & Customer O&M staff at project site and handover in flawless condition of the package to the end customer complete with all accessories for the total scope defined as per BHEL NIT & tender technical specification as specified above, amendments & agreements till placement of order.
MAJOR BREAK-UP OF PRICES GIVEN IN 1.0 ABOVE
Total lump sum firm price inclusive of all prevailing taxes, duties and other levies for Supply part comprising of manufacturing, fabrication, assembly, inspection / testing at vendor's & sub-vendor’s works, painting, maintenance tools & tackles (as applicable), fill of lubricants & consumables alongwith spares requried for erection, start-up and commissioning, forwarding, proper packing, parts / spares required during warranty period (against defects in design, materials, construction and workmanship) shipment and delivery at site, for the total scope defined as per BHEL NIT & tender technical specification as specified above, amendments & agreements till placement of order for MBRAPP-1 & 2. (Break-up as per Annexure-I)
Total lump sum firm price inclusive of all prevailing taxes, duties and other levies for Supply part comprising of manufacturing, fabrication, assembly, inspection / testing at vendor's & sub-vendor’s works, painting, maintenance tools & tackles (as applicable), fill of lubricants & consumables alongwith spares requried for erection, start-up and commissioning, forwarding, proper packing, parts / spares required during warranty period (against defects in design, materials, construction and workmanship) shipment and delivery at site, for the total scope defined as per BHEL NIT & tender technical specification as specified above, amendments & agreements till placement of order for MBRAPP-3 & 4. (Break-up as per Annexure-II)
Total lump sum prices for visits (should include travel expenses to/ fro site, visa/ insurance as applicable, intermediary stay) for Supervision of assembly, erection and commissioning, trial run at site & Training to O&M staff for MBRAPP-1 & 2.
Total lump sum prices for visits (should include travel expenses to/ fro site, visa/ insurance as applicable, intermediary stay) for Supervision of assembly, erection and commissioning, trial run at site & Training to O&M staff for MBRAPP - 3 & 4.
Total lump sum prices including service charges, local transportation, boarding, lodging & other related exepenses for Supervision of assembly, erection and commissioning, trial run at site & Training to O&M staff for MBRAPP-1 & 2.
Total lump sum prices including service charges, local transportation, boarding, lodging & other related exepenses for Supervision of assembly, erection and commissioning, trial run at site & training to O&M staff for MBRAPP - 3 & 4.
Total Lump sump price including site visit charges, all transportation charges, boarding, lodging & other related exepenses for successful conductance of Performance Guarantee test and handover in flawless condition of the package to the customer for MBRAPP-1 & 2.
Total Lump sump price including site visit charges, all transportation charges, boarding, lodging & other related exepenses for successful conductance of Performance Guarantee test and handover in flawless condition of the package to the customer for MBRAPP-3 & 4.
Total Lump sump price for training of employees of customer at manufacturer's works (3 persons for 2 days including lodging and boarding) for MBRAPP-1 & 2.
Total Lump sump price for training of employees of customer at manufacturer's works (3 persons for 2 days including lodging and boarding) for MBRAPP-3 & 4.
Total lumpsum firm price for Mandatory spares comprising of manufacture, fabrication, assembly, inspection / testing (as applicable) at vendor's & sub-vendor’s works, painting, forwarding, proper packing, shipment, delivery at site & handover of mandatory spares to BHEL/End Customer, for the total scope defined as per BHEL NIT & tender technical specification as specified above, amendments & agreements till placement of order for MBRAPP-1 & 2. (Break-up as per Annexure-III & IV)
Total lumpsum firm price for Mandatory spares comprising of manufacture, fabrication, assembly, inspection / testing (as applicable) at vendor's & sub-vendor’s works, painting, forwarding, proper packing, shipment, delivery at site & handover of mandatory spares to BHEL/End Customer, for the total scope defined as per BHEL NIT & tender technical specification as specified above, amendments & agreements till placement of order for MBRAPP-3 & 4. (Break-up as per Annexure-V & VI)
Total lumpsum firm price for Engineering Charges comprising of design (i.e Preparation & submission of drawings/documents including " AS-BUILT" drawings and O&M Manuals and engineering (including product design & engineering, as applicable) as per tender technical specification above, amendments & agreements till placement of order for MBRAPP-1 & 2.
Total lumpsum firm price for Engineering Charges comprising of design (i.e Preparation & submission of drawings/documents including " AS-BUILT" drawings and O&M Manuals and engineering (including product design & engineering, as applicable) as per tender technical specification above, amendments & agreements till placement of order for MBRAPP-3 & 4.
4 X 700 MWe ASHVINI MAHIBANSWARA, RAJASTHAN
COMPRESSED AIR SYSTEM
PE-TS-551-555-A001
DESCRIPTION
Compresssor House - 1 for MBRAPP-1 as specified in technical specification
Compressors - Reciprocating, Non-lubricated, Two-stage, Horizontal, Doubleacting, Opposed pistons of Capacity 20 Nm³/min. @ 8.5 Kg/cm2 (g).
Air Drying Plant - Heat convection blower activated type with Silica gel as adsorbing media of Capacity 20 Nm³/min.
Air Receivers required for Compressed Air System of minimum 9.35 Cu.M capacity each with instruments, relief valve, isolation valve, drain connection with automatic trap stations (zero purge air loss type) and other accessories as specified.
Inter connecting cooling water, drain piping and compressed air piping as specified including fittings, strainers, valves etc. for complete Compressed air system as per system P&ID's attached with the technical specification.
Instruments within skids of Air Compressor, Air Drying Plant, Air Recevier and outside these skids as per system P&ID's attached with the technical specification.
Local Control panel for each Air Compressor, Air Dryer, Interface module(s), JB's for the overall control & monitoring of compressed air system.
Service Air & Mask Air Filters for Compressed Air System as per system P&ID's attached with the technical specification.
Compresssor House - 2 for MBRAPP-2 as specified in technical specification
Compressors - Reciprocating, Non-lubricated, Two-stage, Horizontal, Doubleacting, Opposed pistons of Capacity 20 Nm³/min. @ 8.5 Kg/cm2 (g).
Air Drying Plant - Heat convection blower activated type with Silica gel as adsorbing media of Capacity 20 Nm³/min.
Air Receivers required for Compressed Air System of minimum 9.35 Cu.M capacity each with instruments, relief valve, isolation valve, drain connection with automatic trap stations (zero purge air loss type) and other accessories as specified.
Inter connecting cooling water, drain piping and compressed air piping as specified including fittings, strainers, valves etc. for complete Compressed air system as per system P&ID's attached with the technical specification.
Instruments within skids of Air Compressor, Air Drying Plant, Air Recevier and outside these skids as per system P&ID's attached with the technical specification.
Local Control panel for each Air Compressor, Air Dryer, Interface module(s), JB's for the overall control & monitoring of compressed air system.
Service Air & Mask Air Filters for Compressed Air System as per system P&ID's attached with the technical specification.
Additional below listed items to be supplied for MBRAPP-1 & for MBRAPP-2 as specified in technical specification
SAETY RELIEF VALVE,SA 216 WCB
SAETY RELIEF VALVE,SA 216 WCB
FCS Strainers of Compressed Air Plant, 15NB
FCS Strainers of Compressed Air Plant, 25NB
Automatic Mechanical Drain Traps for Main Air Reciever, FILTER
SS Strainers of Compressed Air distribution, 15NB
SS Strainers of Compressed Air distribution, 25NB
FSS Strainers of Compressed Air distribution, 50NB
4 X 700 MWe ASHVINI MAHIBANSWARA, RAJASTHAN
COMPRESSED AIR SYSTEM
PE-TS-551-555-A001
DESCRIPTION
Compresssor House - 3 for MBRAPP-3 as specified in technical specification
Compressors - Reciprocating, Non-lubricated, Two-stage, Horizontal, Doubleacting, Opposed pistons of Capacity 20 Nm³/min. @ 8.5 Kg/cm2 (g).
Air Drying Plant - Heat convection blower activated type with Silica gel as adsorbing media of Capacity 20 Nm³/min.
Air Receivers required for Compressed Air System of minimum 9.35 Cu.M capacity each with instruments, relief valve, isolation valve, drain connection with automatic trap stations (zero purge air loss type) and other accessories as specified.
Inter connecting cooling water, drain piping and compressed air piping as specified including fittings, strainers, valves etc. for complete Compressed air system as per system P&ID's attached with the technical specification.
Instruments within skids of Air Compressor, Air Drying Plant, Air Recevier and outside these skids as per system P&ID's attached with the technical specification.
Local Control panel for each Air Compressor, Air Dryer, Interface module(s), JB's for the overall control & monitoring of compressed air system.
Service Air & Mask Air Filters for Compressed Air System as per system P&ID's attached with the technical specification.
Compresssor House - 4 for MBRAPP-4 as specified in technical specification
Compressors - Reciprocating, Non-lubricated, Two-stage, Horizontal, Doubleacting, Opposed pistons of Capacity 20 Nm³/min. @ 8.5 Kg/cm2 (g).
Air Drying Plant - Heat convection blower activated type with Silica gel as adsorbing media of Capacity 20 Nm³/min.
Air Receivers required for Compressed Air System of minimum 9.35 Cu.M capacity each with instruments, relief valve, isolation valve, drain connection with automatic trap stations (zero purge air loss type) and other accessories as specified.
Inter connecting cooling water, drain piping and compressed air piping as specified including fittings, strainers, valves etc. for complete Compressed air system as per system P&ID's attached with the technical specification.
Instruments within skids of Air Compressor, Air Drying Plant, Air Recevier and outside these skids as per system P&ID's attached with the technical specification.
Local Control panel for each Air Compressor, Air Dryer, Interface module(s), JB's for the overall control & monitoring of compressed air system.
Service Air & Mask Air Filters for Compressed Air System as per system P&ID's attached with the technical specification.
Additional below listed items to be supplied for MBRAPP-3 & for MBRAPP-4.
SAETY RELIEF VALVE,SA 216 WCB
SAETY RELIEF VALVE,SA 216 WCB
FCS Strainers of Compressed Air Plant, 15NB
FCS Strainers of Compressed Air Plant, 25NB
Automatic Mechanical Drain Traps for Main Air Reciever, FILTER
SS Strainers of Compressed Air distribution, 15NB
SS Strainers of Compressed Air distribution, 25NB
FSS Strainers of Compressed Air distribution, 50NB
4 X 700 MWe ASHVINI MAHIBANSWARA, RAJASTHAN
COMPRESSED AIR SYSTEM
PE-TS-551-555-A001
DESCRIPTION
Mandatary Spares for MBRAPP-1 & for MBRAPP-2. (Break up of PRICES GIVEN IN 2.11 OF MAIN SHEET)
Horizontal Reciprocating Compressor as per NPCIL specifiaction No-PC-E-753
Packing ring
Big end bearing for connecting rod
Big end bearing half
Main bearing for Crank shaft
Main bearing lower half
Main bearing upper half
Suction & discharge valves
Connecting rod bolt with nut & lock nut
Motor Spare Parts for motors Refer spec no:PC-E- 502 Clause no:7.0
Motor drive end bearing sets
Non drive end bearing sets
One set space heater
Seal & other material required at periodic replacement
Bearing RTD one of each type
V-Belt Sets
Piston ring & wear ring for HP cylinder
Piston ring & wear ring for LP cylinder
Set of unloader spring for HP &LP
Oil Filter elements
Air suction filter element assembly
Oil Scraper
Contactors & MCB used
Gasket for HP cylinder
Gasket for LP Cylinder
Rubber 'O ring after cooler sets
Rubber 'O' ring for inter cooler sets
Air Compressor motors
Automatic electrical drain trap
Safety relief valve (50NBX80NB)
Heat Convection Blower Activated type air dryer as per NPCIL Specification No-PC-E-752.
Filter elements for Pre filters and After filters sets
Desiccent (One Set = One additional filling for 2 nos of Dryers in air tight pack condition (Qty as per dryer design calculations))
Safety relief valve (25NBX25NB)
Spares for Blowers
Bearings for Blowers
Bearings for Motors
Couplings
Mechanical seal assembly.
Impeller Assembly
Vibration Isolation pad
Gaskets and elastomers
Motors
Filter panel (Blower Inlet)
Heater Element for each of the Base & trim heaters (3 Nos)
Filter elements for SA & MA filters sets
Instruments, PLC (control Panel for Air Compressor & Air Dryer)
Field instruments (e.g. PTs, DPTs, LTs, RTDs, clamp on Ultrasonic flowmeters, magnetic level gauge, In line conductivity cells, Temperature Transmitters, Conductivity transmitters, Gauges, Switches etc.), limit switches for valves, limit switches & torque switches for motorized valves, position transmitters for control valves, etc. for all systems supplied under CAS Package (One LOT = Minimum 2 nos. of field instruments for each type & each range or 20% of each type and each range whichever is higher)
Electronic modules for Ultrasonic Flow Meters for all systems supplied under CAS PACKAGE. (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher)
Relays, indicating lamps, indicators, Panel indicating meters, MCBs and fuses, Hand switches, Push buttons, Loose electronic components not mounted of PCB (such as capacitor, choke, diodes etc) for all systems and equipments (e.g. PLC panels, Operator Consoles, Electrical valve actuators, etc.) supplied under CAS PACKAGE (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher)
Electronic cards/modules (such as I/O module, processor module, power supply module, interface module, communication module, diagnostic modules, signal conditioning units, signal isolator, frequency modulator, Hub, etc.), peripherals associated with PLC etc. for all systems and equipments (e.g. PLC panels, Electrical valve actuators, etc.) supplied under CAS PACKAGE
Instrument Support Stand (ISS), junction boxes, terminal blocks, cable glands & lugs, mounting accessories, for all systems supplied under CAS PACKAGE (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher )
Secondary instruments (such as E/A converter, valve positioner etc.), tube, tube fittings, 3/5 valve manifolds, instrument isolating valves, drain valves, solenoid valves, PRVs, etc. for all systems supplied and engineered under CAS PACKAGE. (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher )
Mounting accessories for all instruments/systems supplied under CAS PACKAGE. (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher )
Wired spare slots (wired to panel / JB terminals). (One LOT = 20% for future expansion)
I&C wires and cables including LAN, FO cables of each type as used in system engineering (One LOT = Minimum 10% of total length requirement.)
HMI SYSTEMS (One LOT = For all individual modules of HMI, which includes apart from PCs, peripherals and other cards, interconnecting cables and power supplies a minimum of 20 % spares or 2 modules/units (e.g. PC, monitor, LIU, Ethernet Switches, SMPS, Patch cords, MCBs, etc.) of each type & rating, whichever is higher shall be supplied along with the HMI system. )
RH meter cum temperature transmitters
dew point sensor transmitter
Filters panels
Vibration Monitoring System (VMS) for compressor & motor (as applicable)
Field sensors with integral cable, extension cable, monitors, power supply modules, processor modules, interface modules, signal conditioning units, measuring attachment card, signal isolator, frequency modulator, MCBs, monitors, each type of electronic/relay modules (for each variety/version), terminal block, cable glands used in the system, accessories, Junction boxes
Wherever set is mentioned, one set of the spares of that item shall be for complete replacement of that particular item for one equipment.
Any fraction of a item shall mean the next higher integer.
Wherever quantity has been specified as percentage (%), the quantity of mandatory spares to be provided by contractor shall be the specified percentage (%) of the total population of the plant. In case the quantity so calculated happens to be fraction, the same shall be rounded off to next higher whole number.
Wherever the quantities have been indicated for each type, size, thickness, material, radius, range etc., these shall cover all the items supplied and installed and the breakup for these shall be furnished in the bid.
In case spares indicated in the list are not applicable to the particular design offered by the bidder, the bidder should offer spares applicable to offered design with quantities generally in line with the approach followed in the above list.
4 X 700 MWe ASHVINI MAHIBANSWARA, RAJASTHAN
COMPRESSED AIR SYSTEM
PE-TS-551-555-A001
DESCRIPTION
Mandatary Spares for MBRAPP-1 & for MBRAPP-2. (Break up of PRICES GIVEN IN 2.11 OF MAIN SHEET)
COMPRESSOR DATASHEET: DS. NO. : 700MWe/75102/2301/DS
Motor bearings
Compressor Bearings
Liners
Piston Rings (Standard & Ist Oversize)
Set of gaskets
Set of Valve Assemblies
Automatic Moisture Drains
Set of Piston , Pins & Connecting Rods
Motors
Instruments
Filters panels
AIR DRYER DATASHEET: DS. NO. : 700MWe/75106/2301/DS
Desiccant for one additional filling of one complete Dryer in air tight pack condition
Valves & valve consumables
Safety valve for air drying plant
Instruments
Filter Elements & accessories for Pre filters
Filter Elements & accessories for After filters
Bearings of Fan
Bearings of Motor
Coupling
Mechanical seal assembly for Shaft
Impeller Assembly
Vibration isolation pad
Gaskets and Elastomers
Motors
Filters panels
SA & MA FILTERS : DS. NO. : 700MWe/75105/2301/DS
Filter Elements & accessories
Wherever set is mentioned, one set of the spares of that item shall be for complete replacement of that particular item for one equipment.
Any fraction of a item shall mean the next higher integer.
Wherever quantity has been specified as percentage (%), the quantity of mandatory spares to be provided by contractor shall be the specified percentage (%) of the total population of the plant. In case the quantity so calculated happens to be fraction, the same shall be rounded off to next higher whole number.
Wherever the quantities have been indicated for each type, size, thickness, material, radius, range etc., these shall cover all the items supplied and installed and the breakup for these shall be furnished in the bid.
In case spares indicated in the list are not applicable to the particular design offered by the bidder, the bidder should offer spares applicable to offered design with quantities generally in line with the approach followed in the above list.
4 X 700 MWe ASHVINI MAHIBANSWARA, RAJASTHAN
COMPRESSED AIR SYSTEM
PE-TS-551-555-A001
DESCRIPTION
Mandatary Spares for MBRAPP-3 & for MBRAPP-4. (Break up of PRICES GIVEN IN 2.12 OF MAIN SHEET)
Horizontal Reciprocating Compressor as per NPCIL specifiaction No-PC-E-753
Packing ring
Big end bearing for connecting rod
Big end bearing half
Main bearing for Crank shaft
Main bearing lower half
Main bearing upper half
Suction & discharge valves
Connecting rod bolt with nut & lock nut
Motor Spare Parts for motors Refer spec no:PC-E- 502 Clause no:7.0
Motor drive end bearing sets
Non drive end bearing sets
One set space heater
Seal & other material required at periodic replacement
Bearing RTD one of each type
V-Belt Sets
Piston ring & wear ring for HP cylinder
Piston ring & wear ring for LP cylinder
Set of unloader spring for HP &LP
Oil Filter elements
Air suction filter element assembly
Oil Scraper
Contactors & MCB used
Gasket for HP cylinder
Gasket for LP Cylinder
Rubber 'O ring after cooler sets
Rubber 'O' ring for inter cooler sets
Air Compressor motors
Automatic electrical drain trap
Safety relief valve (50NBX80NB)
Heat Convection Blower Activated type air dryer as per NPCIL Specification No-PC-E-752.
Filter elements for Pre filters and After filters sets
Desiccent (One Set = One additional filling for 2 nos of Dryers in air tight pack condition (Qty as per dryer design calculations))
Safety relief valve (25NBX25NB)
Spares for Blowers
Bearings for Blowers
Bearings for Motors
Couplings
Mechanical seal assembly.
Impeller Assembly
Vibration Isolation pad
Gaskets and elastomers
Motors
Filter panel (Blower Inlet)
Heater Element for each of the Base & trim heaters (3 Nos)
Filter elements for SA & MA filters sets
Instruments, PLC (control Panel for Air Compressor & Air Dryer)
Field instruments (e.g. PTs, DPTs, LTs, RTDs, clamp on Ultrasonic flowmeters, magnetic level gauge, In line conductivity cells, Temperature Transmitters, Conductivity transmitters, Gauges, Switches etc.), limit switches for valves, limit switches & torque switches for motorized valves, position transmitters for control valves, etc. for all systems supplied under CAS Package (One LOT = Minimum 2 nos. of field instruments for each type & each range or 20% of each type and each range whichever is higher)
Electronic modules for Ultrasonic Flow Meters for all systems supplied under CAS PACKAGE. (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher)
Relays, indicating lamps, indicators, Panel indicating meters, MCBs and fuses, Hand switches, Push buttons, Loose electronic components not mounted of PCB (such as capacitor, choke, diodes etc) for all systems and equipments (e.g. PLC panels, Operator Consoles, Electrical valve actuators, etc.) supplied under CAS PACKAGE (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher)
Electronic cards/modules (such as I/O module, processor module, power supply module, interface module, communication module, diagnostic modules, signal conditioning units, signal isolator, frequency modulator, Hub, etc.), peripherals associated with PLC etc. for all systems and equipments (e.g. PLC panels, Electrical valve actuators, etc.) supplied under CAS PACKAGE
Instrument Support Stand (ISS), junction boxes, terminal blocks, cable glands & lugs, mounting accessories, for all systems supplied under CAS PACKAGE (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher )
Secondary instruments (such as E/A converter, valve positioner etc.), tube, tube fittings, 3/5 valve manifolds, instrument isolating valves, drain valves, solenoid valves, PRVs, etc. for all systems supplied and engineered under CAS PACKAGE. (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher )
Mounting accessories for all instruments/systems supplied under CAS PACKAGE. (One LOT = Minimum 2 nos. for each type or 20% of each type whichever is higher )
Wired spare slots (wired to panel / JB terminals). (One LOT = 20% for future expansion)
I&C wires and cables including LAN, FO cables of each type as used in system engineering (One LOT = Minimum 10% of total length requirement.)
HMI SYSTEMS (One LOT = For all individual modules of HMI, which includes apart from PCs, peripherals and other cards, interconnecting cables and power supplies a minimum of 20 % spares or 2 modules/units (e.g. PC, monitor, LIU, Ethernet Switches, SMPS, Patch cords, MCBs, etc.) of each type & rating, whichever is higher shall be supplied along with the HMI system. )
RH meter cum temperature transmitters
dew point sensor transmitter
Vibration Monitoring System (VMS) for compressor & motor (as applicable)
Field sensors with integral cable, extension cable, monitors, power supply modules, processor modules, interface modules, signal conditioning units, measuring attachment card, signal isolator, frequency modulator, MCBs, monitors, each type of electronic/relay modules (for each variety/version), terminal block, cable glands used in the system, accessories, Junction boxes
Wherever set is mentioned, one set of the spares of that item shall be for complete replacement of that particular item for one equipment.
Any fraction of a item shall mean the next higher integer.
Wherever quantity has been specified as percentage (%), the quantity of mandatory spares to be provided by contractor shall be the specified percentage (%) of the total population of the plant. In case the quantity so calculated happens to be fraction, the same shall be rounded off to next higher whole number.
Wherever the quantities have been indicated for each type, size, thickness, material, radius, range etc., these shall cover all the items supplied and installed and the breakup for these shall be furnished in the bid.
In case spares indicated in the list are not applicable to the particular design offered by the bidder, the bidder should offer spares applicable to offered design with quantities generally in line with the approach followed in the above list.
4 X 700 MWe ASHVINI MAHIBANSWARA, RAJASTHAN
COMPRESSED AIR SYSTEM
PE-TS-551-555-A001
DESCRIPTION
Mandatary Spares for MBRAPP-3 & for MBRAPP-4. (Break up of PRICES GIVEN IN 2.12 OF MAIN SHEET)
COMPRESSOR DATASHEET: DS. NO. : 700MWe/75102/2301/DS
Motor bearings
Compressor Bearings
Liners
Piston Rings (Standard & Ist Oversize)
Set of gaskets
Set of Valve Assemblies
Automatic Moisture Drains
Set of Piston , Pins & Connecting Rods
Motors
Instruments
Filters panels
AIR DRYER DATASHEET: DS. NO. : 700MWe/75106/2301/DS
Desiccant for one additional filling of one complete Dryer in air tight pack condition
Valves & valve consumables
Safety valve for air drying plant
Instruments
Filter Elements & accessories for Pre filters
Filter Elements & accessories for After filters
Bearings of Fan
Bearings of Motor
Coupling
Mechanical seal assembly for Shaft
Impeller Assembly
Vibration isolation pad
Gaskets and Elastomers
Motors
Filters panels
SA & MA FILTERS : DS. NO. : 700MWe/75105/2301/DS
Filter Elements & accessories
Wherever set is mentioned, one set of the spares of that item shall be for complete replacement of that particular item for one equipment.
Any fraction of a item shall mean the next higher integer.
Wherever quantity has been specified as percentage (%), the quantity of mandatory spares to be provided by contractor shall be the specified percentage (%) of the total population of the plant. In case the quantity so calculated happens to be fraction, the same shall be rounded off to next higher whole number.
Wherever the quantities have been indicated for each type, size, thickness, material, radius, range etc., these shall cover all the items supplied and installed and the breakup for these shall be furnished in the bid.
In case spares indicated in the list are not applicable to the particular design offered by the bidder, the bidder should offer spares applicable to offered design with quantities generally in line with the approach followed in the above list.
4X700 MWe ASHVINI MAHI BANSWARA UNIT 1-4 (NIMEP)
Volume/Section
TECHNICAL DEVIATION
COMMERCIAL DEVIATION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 15.73 MB
Tendernotice_2.pdf
PDF • 8.17 MB
PF.xls
Additional Documents • 0.19 MB
CORRIGENDA02.pdf
PDF • 0.49 MB
CORRIGENDA01.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .