| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48,450Admitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹49,760+₹1,310 (2.70%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S Bharat Enterprises L1 | M/S MIR ELECTRICALS and MECHANICAL ENG WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | Repairs to FASD Mug 50 starter by way of providing and fitting of Single-Phase Preventer (Type: Controller SDz5) with the supply voltage of 380 Volts compatible to the Starter at Water Supply Scheme Danihama. The job includes removal of old damaged Single-phase preventer followed by replacement of the new one. The job further includes checking of all the circuit wiring and necessary repairs if required. The cost on account of all consumables required for carrying out the said job is included in the scope of work. Once connected the system is to be tested on load for gauging the performance. | 1 | Job | 6,970 ₹6,970 Lowest | 8,000 ₹8,000 |
| 2.00 | Providing, installation, testing and commissioning of Power supply monitoring device to replace old damaged devices and providing new one wherever required, for the protection of Motors of reputed make to be installed at various Water Supply Schemes of Rural Sub-Division Srinagar. The Device shall have following features and shall protect against following: -
. Monitors Power supply
. Protects against Phase loss
. Protects against Phase reversal
. Protects against Phase asymmetry.
. Adjustable over and under voltage trip level
. Fixed operate time and release time delay
. LED indication for Power and fault condition
. Automatic recovery on fault removal.
Technical Speciation: -
Type - Phase, Neutral and Voltage control.
Supply voltage - 415 Volt AC, 3Phase 4-wire.
Frequency -47 to 53 HZ.
Trip settings UV - 55% to 95% of Supply voltage
OV- 105% to 125% of Supply voltage
Time Delay ON Delay-0.5sec to 15 Min (Selectable)
Trip time (Off Delay)- 5 sec
The job includes fixing of the device to the system and includes cost on account of copper cable, thimbles etc and other consumables required for carrying out the said job. Once connected the system is to be tested on load.
1) WSS Zawoora 2nd, 2) WSS Balhama Old, 3) WSS Zaffron Colony, 4) WSS Athwajan -------------(Khonmoh Belt)
5) WSS Danihama, 6) WSS Mulfaq, 7) WSS Yehal Chatterhama, 8) WSS Naqashband Colony----------- (Zakura Belt) | 8 | Jobs | 2,830 ₹22,640 | 2,670 ₹21,360 Lowest |
| 3.00 | Providing and fitting of Digital Voltmeter with range of 0-500 Volts to replace old damaged volt meter
Make: AE/ L&T/ Rishabh. (1 No each for Panel and Stabilizer)
1) WSS Danihama, 2) WSS Yehal Chatterhama,
3) WSS Khimber, 4) WSS Naqashband Colony, 5) WSS Mulfaq,
6) WSS, Tailbal. | 12 | Nos | 1,570 ₹18,840 Lowest | 1,700 ₹20,400 |
Tender Value
₹49,900
Closing Date
25 Nov 2025, 11:30 amClosed
Executive Engineer JS PHE Mech. Rural Div. Sgr.
Executive Engineer JS PHE Mech. Rural Div. Sgr.
Providing and Fitting of Essential Electrical Items for various Water Supply Schemes at Jal Shakti (PHE) Mechanical Rural Sub-Division Srinagar
2025_PHE_295592_1
PHE/MRD/TS 49 OF 11/2025
Open Tender
Miscellaneous Works
Item Rate
5 days
Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹50
Executive Engineer JS PHE Mech. Rural Div. Sgr.
26 Nov 2025
18 Nov 2025
25 Nov 2025
18 Nov 2025
25 Nov 2025
18 Nov 2025
Amount
Repairs to FASD Mug 50 starter by way of providing and fitting of Single-Phase Preventer (Type: Controller SDz5) with the supply voltage of 380 Volts compatible to the Starter at Water Supply Scheme Danihama. The job includes removal of old damaged Single-phase preventer followed by replacement of the new one. The job further includes checking of all the circuit wiring and necessary repairs if required. The cost on account of all consumables required for carrying out the said job is included in the scope of work. Once connected the system is to be tested on load for gauging the performance.
Providing and fitting of Digital Voltmeter with range of 0-500 Volts to replace old damaged volt meter Make: AE/ L&T/ Rishabh. (1 No each for Panel and Stabilizer) 1) WSS Danihama, 2) WSS Yehal Chatterhama, 3) WSS Khimber, 4) WSS Naqashband Colony, 5) WSS Mulfaq, 6) WSS, Tailbal.
M/S MIR ELECTRICALS and MECHANICAL ENG WORKS (BID ID -2650702)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_956961.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .