| 1 | L1₹4.9 CrAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹4.9 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹5.2 Cr+₹25.8 L (5.23%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹5.2 Cr+₹25.8 L (5.23%) | L2 | Rejected-Finance Not L1 bidder |
| 3 | L3₹5.4 Cr+₹46.8 L (9.49%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹5.4 Cr+₹46.8 L (9.49%) | L3 | Rejected-Finance Not L1 bidder |
| 4 | L4₹5.4 Cr+₹49.3 L (9.99%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹5.4 Cr+₹49.3 L (9.99%) | L4 | Rejected-Finance Not L1 bidder |
| 5 | L5₹5.5 Cr+₹59.1 L (12.0%)Rejected-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹5.5 Cr+₹59.1 L (12.0%) | L5 | Rejected-Finance Not L1 bidder |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
22 Sept 2022, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
UPGRADATION OF ELECTRICAL SYSTEM AND ADDITION/ALTERATION TO STREET LIGHTS AT HISAR MIL STN
2022_MES_547312_1
CEJZ/NIT/HSR-04 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
HISAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE Hisar
₹6.8 L
Yes
25 Oct 2022
26 Aug 2022
24 Sept 2022
26 Aug 2022
22 Sept 2022
17 Sept 2022
Amount
Supply, installation, testing and commissioning of LT Panel board, outdoor type, double door, floor mounted, CPRI type tested, factory assembled made out of 3.15mm thick CRCA sheet with both side hinged (front and back), angle iron pedestal frame, compartmental type, weather, dust and vermin proof, IP-54 protection, free standing suitable for working on 415V, 3 Phase, 50 Hz AC supply, painted internally and externally with powder coating as per seven tank process and mounted on angle iron frame, cable alley, cable entry hole at bottom including aluminium bus bar of capacity 1.5 times of Incoming MCCB for 3 Phase and neutral with non-adhesive colour coded insulation sleeves mounted on bus bar insulators, drilled holes on bus bar strips for tapping aluminium strips of suitable size for connecting of MCCBs including nuts, bolts and washers complete and comprising of following items Location :- Near 561 Block , Joginder Vihar
Taking out the old unserviceable LT underground cable upto 25 Sqmm, 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed. Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply , laying , jointing, testing and commissioning of size10 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed. Note : Excavation, earth work, sand cushion & brick protection shall be measured and paid separately.
Supply & Fixing for street light PVC junciotn box of size not less than 310mm x 285mm x180mm made out of polycarbonate, having front side openable duly provide with locking arrangement and also provide with 2 No alumunium bus bar of rating 20 Amps of 6 Amps MCB single pole and provison of 2 No cable entrees complete fixed LT pole with proper MS clamp and connected complete all as specified.
Supply and fixing FRLS PVC insulated copper conductor three core 1.5 Sqmm fixed on pole/wall as required complete all as specified and directed
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with and fixed complete to walls and ceilings or laid in floors for protection of LT electric cable complete all as specificied and directed.
M&L for Galvanized iron tubing, 100 mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete.
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 25mm x 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 mmx 25mm x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 25mm x 4 mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
Dismantling of ACSR conductors of any size complete all as directed.
Dismantling of Earth Wire conductors of any size complete all as specified.
Dismantling cross-arms of M.S. channel or angle sections including nuts & bolts etc complete all as as specified.
Dismantling insulators any type and any size complete all as directed.
Dismantling unserviceable concrete/steel tubular pole of any size removing from site etc complete all as specified and directed. Note : Cost of dismantling of ACSR conductor MS work,insulators etc are not included in the unit rate of this item
Supply, fixing, installing and commissioning of Octagonal Hot-Dip Galvanised Street light Pole 8 mtr long, Top dia (A/F), bottom dia (A/F), base plate dimensions & foundation bolts dimensions etc shall be all as mentioned in manufacturer’s Cat Part, sheet thickness 3mm, single arm bracket, suitable for 1100 Volts grade including cost of nuts, bolts and all accessories as supplied by the manufacturer, door locking arrangement, Terminal Plate consisting of 2 Nos 10A, 4 Pole neutral links including connections etc with suitable connecting arrangement for 2 Nos (incoming & outgoing), including cost of foundation, excavation and earthwork in soft/loose soil, RCC {1:1.5:3 type A1} for foundation of shape & size all as per manufacturer’s instruction complete all as specified and directed, Material specification mast & pole shaft : BSEN 10025, ASTM A572, IS 5986, Foundation – IS 2062/E250A, Base Plate IS-2062, Galvanization IS:4759/2629 and ASTM A123. Make:- Jindal Cat Part No JIL8010C / Crompton Cat Part No HM-1108P / Bajaj Cat Part No BOP8030.
Supply, fixing, installing and commissioning of Octagonal Hot-Dip Galvanised Street light Pole 9 mtr long, Top dia (A/F), bottom dia (A/F), base plate dimensions & foundation bolts dimensions etc shall be all as mentioned in manufacturer’s Cat Part, sheet thickness 3mm, double arm bracket, suitable for 1100 Volts grade including cost of nuts, bolts and all accessories as supplied by the manufacturer, door locking arrangement, Terminal Plate consisting of 2 Nos 10A, 4 Pole neutral links including connections etc with suitable connecting arrangement for 2 Nos (incoming & outgoing), including cost of foundation, excavation and earthwork in soft/loose soil, RCC {1:1.5:3 type A1} for foundation of shape & size all as per manufacturer’s instruction complete all as specified and directed, Material specification mast & pole shaft : BSEN 10025, ASTM A572, IS 5986, Foundation – IS 2062/E250A, Base Plate IS-2062, Galvanization IS:4759/2629 and ASTM A123. Make:- Jindal Cat Part No JIL9010C / Crompton Cat Part No HM-1109P / Bajaj Cat Part No BOP9030.
Material and labour for 15 mtr long High galvanised mast light suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6mm dia 97/19 guage and double drum winch with luminaire mounting arm, pulley assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height complete all as specified and directed Note :- The scope includes raising & lowering system (R&L), trailing cable, power tool, feeder pillar for switching operation of luminaries, lightning finial and aviation obstruction light. The R & L system will comprise of double drum winch, SS wire rope not less than 6mm, head frame and lantern carriage. The Job also includes RCC foundation work as per manufacturer’s instructions suitable for 15 mtr long High mast light.
Supply and fixing LED street light fitting LED 60 watt 230 Volt AC out door type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complee all as specified and directed . Make: Crompton Cat Part No LST-60-CDL-M / Havells Cat part No ENDURAOMNIPLUSSL60WLED757SASYTOPC/ Wipro Cat Part No LR02-671-XXX-57-G3
Supply and fixing LED street light fitting LED 90 watt 230 Volt AC out door type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection Make: Crompton Cat Part No CRP-404-90-57-SL-GL-NSG / Havells Cat part No ENDURAOMNIPLUSSL90WLED757SASYTOPC/ Wipro Cat Part No LR02-102-XXX-57-G2
Supply and fixing LED Flood light 120 Watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp suitable high mast incl all accessories for fixing on mounting Make:- Crompton Cat Part No LFLN-120-WW/60-M / Havells Cat part No JETAIRISFL120WLED757ARNBLTG/ Wipro Cat Part No LF34-132-060-57-XX
Supply & fixing nature switch ( using infra Red sensor technology ) based automatic street light control. The panel should be suitable enough to take three load of 5 kW with 3 Nos contactors, 3 Nos incoming MCB & 3 Nos outgoing MCB of rating 20-25 Amps & main load circuit wiring of 10sqmm. The system should be enclosed in IP 54 enclosure with angle frame to mount on it with PCC foundation complete all as specified and directed. Make: Healer enterprises/BHUPAL digital timer/ Legrand
Taking down existing street light fittings any capacity fixed in any position i.e. on wall/ pole/ watch tower for repairing, opening & checking the fitting in presence of Engineer-in-Charge . Note : (i) Old unsv security lights shall be of the contractor property and amount of old material / fittings shall be recovered from the contractor as per sch of credit (ii) Serviceable lights will be deposited in MES store yard for refixing and shifting to another places
S&F LED street light fittings 45 Watt, 230 AC, outdoor type with high pressure die cast housing and heat resistant complete with driver lamp bracket with impact in corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection, Make – Havells / Philips/Bajaj/ Crompton/ C&S or equivalent in approved list of SWC
Fixing only the serviceable security lights in any position i.e. on wall/pole/watch tower complete all as specified and directed .
S&F in replacement street light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 meter length fixed with & including necessary MS Calmps of size 40x5mm including nuts, bolts and washers on pole etc including paint to MS clamp with two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for rigid non-metallic PVC conduit 25 mm dia including fixing on pole/wall with fittings such as tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc. complete all as specified and as directed .
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete Note :- GI pipe shall be measured and paid in respective Item of BOQ.
Earth work in excavation in all kind soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed. Note :-Cost for removing bricks laid as cable cover is deemed to be included in the rate quoted
Earth work in excavation in all kind soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift exc1.5 m but n exc 3.0m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed. Note :-Cost for removing bricks laid as cable cover is deemed to be included in the rate quoted
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick. Etc complete all as specified and directed
M&L for sand cushioning 230mm thickness with river dry sand (One layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as specified and directed. Note : For the purpose of payment, only punned thickness shall be measured
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as directed.
M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc complete all as specified and directed.
Labour only fortaking out & refixing the serviceable MCCB in any existing panel whose MCCB got damaged/Burnt complete with all accessories as specified and directed .
Dismantling of existing u/s LT panel after removing all electrical connections, cables etc and removing the same from site complete all as specified and directed.”
Dismantling the existing earthing from site complete all as specified and directed.
Supply and fix earth continuity conductor or earthing lead fixed to wall or buried in ground or drawn in conduit/pipe or fixed to pole etc as required of size 25mmx4mm galvanised strip in 40mm bore GI pipe light grade complete all as specified and as directed.
S & F Cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm.
S & F Cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
stage.html
html • 0.10 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .