Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 8 34A FATHIMAPURAM KOLLEMCODE P O KANYAKUMARI 629 160 | KOLLEMCODE | KANYAKUMARI | TAMIL NADU | 629160 | Admitted-Finance |
| 2 | Admitted-Finance 2ND FLOOR PAPPOOTTY COMPLEX VAZHAKULAM MUVATTUPUZHA KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | Admitted-Finance |
| 3 | Admitted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Prequalification criteria not fulfilled and Tender Acceptance Letter not submitted |
Tender Value
Refer Docs
EMD Value
₹69,750
Closing Date
27 Jan 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Mechanical Engineer, VOC Port Trust
Administrative Office, VOC Port Trust, Tamil Nadu 628004
Replacement of existing TANGEDCO 4 Pole Structure (OH) outside VOCPT premises and HT Structure of Metering Point (OH) inside VOCPT premises by 2 nos. of Outdoor Ring Main Units with Load Break Switch under supervision of TANGEDCO Engineers
2022_VOCPT_101004_1
VOCPT/MEE/69236/2021-22
Open Tender
Electrical Works
Lump-sum
120 days
VOC Port Trust
As per Tender Document
15 documents required · 15 mandatory
₹0
₹69,750
Yes
11 Mar 2022
8 Jan 2022
28 Jan 2022
8 Jan 2022
27 Jan 2022
8 Jan 2022
120 days
Amount
Supply, erection, testing & commissioning of 1 No. double pole cable structure using PSC pole (HT 9m PSC pole) in position including fitting 2 channel cross arms, digging and backfilling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing. The double pole structure shall be provided with 200Amps 22KV AB switch (complete set), HG Fuse, lightning arrestor, 22KV Pin Insulator with Pin, along with Strain Disc, metal parts, stay set, MS bolts & nuts, hardwares, etc.
Design, Supply, Erection, Testing and Commissioning of 22kv, 630A, 21kA for 1s, SF6 insulated, outdoor type DA compatible 4way Extensible Ring Main Unit with 3 Nos. of Motorized Vacuum Circuit Breaker and 1No. Manual operated Load Break Switch for the following specifications with all standard accessories including provision of terminal protector boots & extension modules, actuators for remote operations, power & control wiring and connections, providing terminal protector, suitable foundation, base plates, fixing anchor bolts, handling, erection, alignment, allied works, inter connecting RMU bus bar and control cables, providing metered supply from nearest source. Providing 2 Nos pipe earthing cable mounting & terminations, giving connections after ascertaining proper phase sequence, providing location name& warning boards, conducting all precommissioning tests as required, complete. Technical specifications: Service voltage: 22Kv, Rated voltage:24Kv,Power Frequency voltage withstand: 50kV, Impulse Voltage withstand: 125kVp, Rated Current Busbar: 630A, Rated Current Switch: 630A, Rated Current Breaker: 630A, Rated short-time current: 21kA for 1s, Short circuit making current: 40kA, Frequency:50HZ, Environment temperature range: - 5ºC / 40 ºC Relative Humidity: 95% Altitude: <1000m, Installation type : Outdoor, Compact Metal clad Switchgear, SF6 insulated, Switching Tech.: SF6 (Switches), Protection degree: IP54, Main Busbar: Copper 400 sqmm, Earth Bus: Copper 240 sqmm, SF6 Tank Material: Stainless Steel, Interlocks: Standard Colour: RAL 7012 / RAL 7032 / RAL 7035 or its equivalent; Label language: English Package: Corrugated Cardboard, Standards : IEC 62271-1, IEC 62271-100, IEC 62271-200; Common items & Accessories: Manometer with Green & Red zone for indicating pressure of gas inside the tank fitted on RMU.-1No, Operating Handle (Supplied Loose with RMU) - 1Set; The combined unit shall consist of the following: 1set of 630Amps continuously rated copper bus bars with proper insulations, positive standard mechanical interlocks to avoid unsafe operations, padlocking for open, close, Earth position in correct sequence. Air insulated cable box with gland plate suitable for bottom entry of 3Core cable up to 400 sqmm., Over current & earth fault relay with digital display & self-powered., Current Transformers-3Nos provided in cable box having ratio of 100-150-200/5A, Protection: Class 5P 10, 2.5VA, Actuator kit for motorized operation, Capacitive voltage indicators-LED Display, Mimic diagram on front panel, complete with status indicators(ON-OFF-EARTH), Epoxy molded low Energy tripping coil for tripping the circuit breaker in fault condition, Local Push to trip mechanism for emergency trip, Cable termination busing suitable for 1 run size upto 3cx400sqmm XLPE cable- 1set, 22kV Touch proof boot suitable for-22kv-1set. The erection / testing / commissioning of the RMU sahll be done using contractors own men and materials as per the standard industrial safety practices / procedures and TANGEDCO guidelines if any, including all the civil engineering works required for the installation of the RMU and in a manner as directed by Engineer in charge. [Note: 1. Obtaining necessary drawing approval for RMU from TANGEDCO is under the contractor's scope of work. 2. One No. of Non-directional, 3 O/C + 1 E/F Numerical relay and 1 No. high speed tripping relays are to be provided in the VCB panels] Makes of RMU: ABB/SIEMENS/SCHNEIDER/C&S/CG/ LUCY ELECTRIC/SAFVOLT
Design, Supply, Erection, Testing and Commissioning of 22kv, 630A, 21kA for 1s, SF6 insulated, outdoor type DA compatible 1way Extensible Ring Main Unit for Board Side Metering with provision for metering module with energy meter, 150/5A CT arrangements for the following specifications with all standard accessories including provision of terminal protector boots & extension modules, actuators for remote operations, power & control wiring and connections, providing terminal protector, suitable foundation, base plates, fixing anchor bolts, handling, erection, alignment, allied works, inter connecting RMU bus bar and control cables, providing metered supply from nearest source. Providing 2 Nos pipe earthing cable mounting & terminations, giving connections after ascertaining proper phase sequence, providing location name& warning boards, conducting all precommissioning tests as required, complete. Technical specifications: Service voltage: 22Kv, Rated voltage:24Kv,Power Frequency voltage withstand: 50kV, Impulse Voltage withstand: 125kVp, Rated Current Busbar: 630A, Rated Current Switch: 630A, Rated Current Breaker: 630A, Rated short-time current: 21kA for 1s, Short circuit making current: 40kA, Frequency:50HZ, Environment temperature range: - 5ºC / 40 ºC Relative Humidity: 95% Altitude: <1000m, Installation type : Outdoor, Compact Metal clad Switchgear, SF6 insulated, Switching Tech.: SF6 (Switches), Protection degree: IP54, Main Busbar: Copper 400 sqmm, Earth Bus: Copper 240 sqmm, SF6 Tank Material: Stainless Steel, Interlocks: Standard Colour: RAL 7012 / RAL 7032 / RAL 7035 or its equivalent; Label language: English Package: Corrugated Cardboard, Standards: IEC 62271-1, IEC 62271-100, IEC 62271-200; Common items & Accessories: Manometer with Green & Red zone for indicating pressure of gas inside the tank fitted on RMU.-1No, Operating Handle (Supplied Loose with RMU) - 1Set; The combined unit shall consist of the following: 1set of 630Amps continuously rated copper bus bars with proper insulations, positive standard mechanical interlocks to avoid unsafe operations, padlocking for open, close, Earth position in correct sequence. Air insulated cable box with gland plate suitable for bottom entry of 3Core cable up to 400 sqmm., Over current & earth fault relay with digital display & self-powered., Current Transformers-3Nos provided in cable box having ratio of 100-150-200/5A, Protection: Class 5P 10, 2.5VA, Actuator kit for motorized operation, Capacitive voltage indicators-LED Display, Mimic diagram on front panel, complete with status indicators(ON-OFF-EARTH), Epoxy molded low Energy tripping coil for tripping the circuit breaker in fault condition, Local Push to trip mechanism for emergency trip, Cable termination busing suitable for 1 run size upto 3cx400sqmm XLPE cable- 1set, 22kV Touch proof boot suitable for-22kv-1set. The erection / testing / commissioning of the RMU sahll be done using contractors own men and materials as per the standard industrial safety practices / procedures and TANGEDCO guidelines if any, including all the civil engineering works required for the installation of the RMU and in a manner as directed by Engineer in charge. [Note: 1. Obtaining necessary drawing approval for RMU from TANGEDCO is under the contractor's scope of work. 2. One No. of Non-directional, 3 O/C + 1 E/F Numerical relay and 1 No. high speed tripping relays are to be provided in the VCB panels] Makes of RMU: ABB/SIEMENS/SCHNEIDER/C&S/CG/ LUCY ELECTRIC/SAFVOLT
Supply & laying of 3 X 400 Sqmm 22KV HT XLPE UG cable with stranded compacted circular aluminium conductor, XLPE insulated, sheathed, extruded semi conducting XLPE compound screening, followed by a layer of copper tape, cores laid up with fillers, wrapped layer of copper tape, thermoplastic tape, extruded PVC Type ST2 inner sheath, GS Round wire armoured and over all conforming to IS: 7098 (II)/1985 with latest amendments, in a excavated trench, threading through pipes and elsewhere, jointing, testing and commissioning in approved manner, with suitable cable length in places as directed by Engineer in Charge. For laying cable, trench to be excavated at a depth of 1mtr putting 0.15meter layer of sand and covering the cable completely with box side bricks and sand and refilling the sand as per site requirement. Cable identification tags at 5mtr intervals shall be provided. (A. Cable from 4 way RMU to 1 way metering RMU, 2 runs; B. Cable from existing 4 pole structure to 4 way RMU, 2 runs; C. Cable from DP structure to 4 way RMU, 2 runs) Make: RPG/Universal/ Havells/ Polycab
Supply & fixing of outdoor cable end termination kit of heat shrinkable type suitable for 3 X 400 Sqmm 22KV HT XLPE UG cable and terminating thereof complete in a manner as directed by Engineer in charge. Make: Raychem / Elmer / RPG / G-Seal / Denson
Supply & providing straight through joint kit for XLPE 3 X 400 Sqmm. 22KV HT UG cable including excavation of cable from ground and refilling the sand or from outdoor structure and making good as per site requirement, as directed by Engineer in charge. Make: Raychem / Elmer / RPG / G-Seal / Denson
Dismantling existing UG cable (2runs from 4 pole strucutre to HT metering point of DP strucutre and transporting to store / stacking place of Section Engineer in charge duly following standard industrial and safety practices / procedures using contractor's men and materials complete in a manner as directed by Engineer in charge at site.
Dismantling of existing 4 pole strucutre after disconnecting existing terminations / HT equipments, stays, leading, etc. and transporting to store / stacking place of Section Engineer in charge duly following standard industrial and safety practices / procedures using contractor's men and materials complete in a manner as directed by Engineer in charge at site.
Dismantling the existing metering point 2 pole strucutre and metering set after disconnecting existing terminations / HT equipments, stays, leading, etc. and transporting to store / stacking place of Section Engineer in charge duly following standard industrial and safety practices / procedures using contractor's men and materials complete in a manner as directed by Engineer in charge at site.
Dismantling of exisitng 22KV line with 7/2.59mm ACSR (three conductors) including dismantling crossarm, insulators, disc, disconnecting jumper connections. disconnecting existing terminations / HT equipments, stays, leading, etc. and transporting to store / stacking place of Section Engineer in charge duly following standard industrial and safety practices / procedures using contractor's men and materials complete in a manner as directed by Engineer in charge at site.
Earthing as per the ISI specification with an earth electrode of 2.1 Mtr. of class"B" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonary work and with 38mmRCC cover slab for the brick masonary including digging separate pit (0.45x0.45x2.5mtr) at standard distance of 1.5 mtr away from the pole/strucutre in ordinary soil & backfilling the pit with 1.5cm alternate layer of charcoal, salt and sand upto 90cm from the bottom.
Supply and laying / leading / connecting the earth electrodes with MDB / Cubicle panel / Ring Main Unit or elsewhere using 50mm X 6 mm hot dip galvanized GI flat duly buried in ground / floor, embedding in wall or elsewhere complete in a manner as directed by Section Engineer in charge at site.
LINSTA SERVICES
vk sam engineering
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .