Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹34.5 L+₹1.1 L (3.20%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹35.1 L+₹1.6 L (4.76%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹35.1 L+₹1.6 L (4.76%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹37.8 L+₹4.3 L (12.9%)Rejected-AOC 23 8 SANJAY COLONY AKHNOOR 181201 JAMMU KASHMIR | AKHNOOR | JAMMU | JAMMU KASHMIR | 181201 | L5 | Rejected-AOC Other than L1 |
Tender Value
₹45.4 L
EMD Value
₹90,840
Closing Date
29 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(North) Akhnoor
Garrison Engineer(North) Akhnoor PIN 181201 CO 56 APO
SPL REPAIR TO BLDG NO P-73 (JCOs MD ACCN) AT RLT VIHAR INCLUDING BLDG NO T-4, T-5, P-10 AND P-11 AT BSO UNDER GE (N) AKHNOOR
2024_MES_648355_1
CANO- GE(N)/AKH-74/2023-2024
Open Tender
Job Works
Item Rate
180 days
Akhnoor
Class D Cat a i
8 documents required · 8 mandatory
₹500
Yes
GE (North) Akhnoor
₹90,840
Yes
9 Sept 2024
30 Mar 2024
6 May 2024
30 Mar 2024
29 Apr 2024
15 Apr 2024
Amount
Taking down old unsv roof treatment including PCC padding if any, plastering, removing existing bitumen felt treatment including brushing, cleaning top surface of roof slab, brooming etc complete all as specified and directed.
Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound on fair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra lime or cement ) all as specified and directed. (Rate quoted shall be deemed to include Water proof compound.)
Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as specified and approved including demolition and filling of sunken floor with & including PCC 1:5:10 type E-2 (using 40mm brick aggregate). (a) First layer of slurry of cement @0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours. (b) Second layer of slurry of cement @0.242 kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/Sqm. This layer allowed to air cure for 4 Hours. (c) 15mm thick plaster in CM 1:3 mixed with WP compound to be provided while concrete is still green. (d) Joint of/Trap/WC/Soil pipes shall be properly sealed with sealing compound. Note:(a) Concrete for sunken slabs shall be mixed with WP compounds as per manufacturer's instructions. Before carrying out water proofing treatment the sunken slab shall be tested with water for 48 hours for any leakage /dampness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested before passing for next stage. (The rate quoted includes water proofing compound as per manufacturers instructions). (b) Please note that only floor area shall be measured for payment purpose.
Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with & including screed bed 15mm thick in CM 1:4, complete all as specified and directed.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified.
Taking down cement plaster on stone or brick walls/ceiling etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
Rendering 10mm thick cement plaster with cement mortar (1:6) on other than fair faces of brick work or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Applying 2mm thick wall care putty on old/ newly plastered surfaces of walls and prepare to receive painting complete all as specified and directed.
Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed.
Preparation of old painted surfaces by washing, rubbing down and stopping of distempered or painted walls and applying two coats of oil bound distemper complete all as specified and as directed.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and as directed.
Preparation of plastered or unplastered surfaces of wall by washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of cement based paint all as specified and directed.
Preparation of old plastered surfaces on ceiling and applying two coats of oil bound distemper complete all as specified and directed.
Two coats oil bound distemper over a coat of approved primer (alkali resistant priming paint) on newly plastered surfaces of ceiling including preparation of surfaces complete, all as specified and directed
Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:3 including formwork/scaffolding work upto height 7.00mtr above ground level of bldg complete all as specified and as directed.
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for including removing the rubbish off the premishes complete all as specified and directed.
Reinforced cement concrete nominal mix Type B-0 1:2:4 (12.5 mm graded aggregate) for cooking platform ,Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including sup- ports, overhangs, etc. complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed
Green Marble work 18mm to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) inclduing pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Green marble with & including 15mm thick screed bed/base in CM 1:4, roughening/cleaning to existing surface of old concrete floor by picking, sweeping clean and washing down with water to remove dirt/dust and brushing neat cement slurry with 3.0 kg of cement per sqm all as specified and as approved.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with & including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
Ditto as per srl item No 27 but in dado/skirting including 10mm thick rough plaster in cement and sand mortar 1:4, complete all as specified and directed.
Glazed ceramic tile 450mmx350mmx6-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4, complete all as specified and directed.
20-25mm thick Machine cut Kota stone slab flooring, bedded and jointed with grey cement slurry and pointed with grey cement mixed with admixture or pigment to match the shade of Kota stone slab as approved by GE, laid over and including screed bed or bedding layer of mortar 20mm thick in Cement Mortar (1:3) including cutting, grinding and mirror polishing complete, all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar, jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete laid over & including 10 mm thick in CM 1:3 screed for laying Kota Stone, complete all as specified and as directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed.
Pressed steel frames of sizes 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar, all as specified and directed.
Pressed steel frames of sizes 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar, all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
PCC 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in filling of pressed steel frame as in 50 mm parapet coping or in lintels upto 1.5m clear span, cills, plinth courses, string courses, coping, kneelers etc all as specified and directed.
PCC 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed.
35 mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 199 (Part-I). Flush door shutter shall be internally lipped as per clause 8.52.2 of SSR-2009 Part-I complete all as specified and directed.
Glazed and skeleton shutters 30 mm thick second class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for sucuring witre mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a).
Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
100 mm butt hinges, medium weight cold rolled mild steel all as specified and directed.
Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed.
Aluminium anodised barrel tower bolt 150 mm, extruded section all as specified and directed.
Hasp and stapple safety type of aluminium anodised 100 mm long as in cupboard locker all as specified and directed.
75 mm butt hinges, medium weight cold rolled mild steel all as specified and directed.
Aluminium anodised sliding door bolts round nuckle with hasp and stapple extruded section or cast aluminium alloy 300 mm long complete all as specified and directed.
Steel window/ventilator (Box type) factory made with double shutter (wire gauged shutter and glass/glazed shutter, wire cloth and glass paned shall be measured and paid separately of size 79mm x 39 mm, 16 guage rectangular tubular frame with side hung. fixed in repairs complete all as specified and as per drawing No CEUZ/TD/1269/2008 Sheet 1/1 to 1/3.
-Ditto- All as per item No 48 above but W/O glazing bar.
Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed all as specified and directed.
Glazing with sheet glass 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Figured glass sheet, 4.00mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,nodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
12mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as in kitchen cupboard and bottom shelf of cooking platform complete all as specified and directed.
External teak wood lipping 6 mm thick fixed with nails for 12mm thick board, complete all as specified.
Curtain rod, 20 mm dia Stainless steel ,chromium plated incl taking down of old curtain rods, all as directed.
Preparation of new steel and iron surfaces over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with one coat of synthetic enamel paint all as specified and directed.
Preparation of new untreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed.
Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed.
Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc., complete all as specified and as directed.
Mild steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Mild steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
15 mm bore Gun-metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed high pressure with crutch or butterfly handle fixed in repairs complete all as specified and as directed.
20 mm bore Gun-metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed high pressure with crutch or butterfly handle fixed in repairs complete all as specified and as directed.
Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) fixed in repairs complete all as specified.
PVC valve less, symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections fixed in repairs, complete all as specified and directed..
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'P' trap 110mm bore, connection to trap and flush pipe fixed in repairs complete all as specified and directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make specified in list make as approved by GE.
Vitreous china wash basin, white, flat back, size 550x400mm including waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe etc., fixed in repairs complete all as specified and as directed. Cat Part No-10086 of Hindware for Wash basin or its equivalent cat part of make specified in list make as approved by GE.
PVC connection 15 mm size, of length 600mm, with PTMT nuts supplied and fixed in repairs complete all as specified.
Tubular towel rail 60cm long 20mm dia D type aluminium anodised incl necessary brackets, fixed, complete all as specified and directed.
Brass chromium plated shower rose 125mm size with or without swivel joints, with arm any size, including fixing to steel pipe or union complete all as specified and directed
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern), including all fittings, heads , shoes bends , swan-necks etc complete all as specified and directed.
110mm bore PVC SWR Type-B (Pressure not less than 6 Kg cm2) pipes single socket in any length with rubber joints fixed in floors etc all as specified and directed.
75mm bore PVC SWR Type-B (Pressure not less than 6 Kg cm2) pipes single socket in any length with rubber joints fixed in floors etc all as specified and directed.
PVC (SWR) bends any radius 110mm dia with oval access doors fixed in repairs complete all as specified and directed.
PVC (SWR) bends any radius 110mm dia fixed in repairs complete all as specified and directed.
PVC (SWR) bends any radius 75mm dia with oval access doors fixed in repairs complete all as specified and directed.
PVC SWR 110mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
PVC SWR 75mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
PVC (SWR) branch piece of 110 bore pipe, single (single Y) equal or unequal ordinary or inverted (spigot or socket type) provided with access door fixed in repairs complete all as specified and directed.
PVC (SWR) junction four face Tee equal or unequal of 75mm bore provided with access door fixed in repairs, complete all as specified and directed.
PVC (SWR)110 mm junction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door fixed in repairs all as specified and as directed.
PVC cowls 110mm fixed in repairs complete all as specified and directed.
PVC cowls 75mm fixed in repairs complete all as specified and directed.
PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement fixed in repairs complete all as specified.
Plate rack made of stainless steel 0.8mm thick overall size 786mm x 610mm x 254mm fixed in repairs, complete all as specified and directed.
Sinks with drainage board made of stainless steel (1mm thick) kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm as approved by Engr-in-Charge, fixed in repairs complete all as specified and directed.
CP angle valve/concealed stop cock (weight not less than 0.40Kg cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore fixed in repairs complete all as specified and directed.
15 mm CP Bib taps (Long body and weight not less than 0.40Kg fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fixed in repairs complete all as specified and directed.
Brass Chromium plated wall mixture with Telephonic shower arrangement for mixing hot cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type fixed in repair complete all as specified and directed. Make:- Jaquar cat part No CON-217KN or equivalent cat part of make as specified in P.S..
CP Brass Mixture For Kitchen Sink , cast copper alloy (ISI Marked) fancy type chromium plated for mixing hot and cold water screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore fixed in repairs complete all as specified and directed.
Stainless steel Soap dish, any type, fixed with plugs chromium plated brass screws fixed in repairs complete all as specified and as directed.
Corner Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 Cm wide with chromium plated bracket guard and railing 60cm long fixed in repairs complete all as specified and directed.
Mild steel Framed work such as Water tank stand,Cooler stand(Incl fasteners for cooler stand) etc.with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290.Gde-E-165
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for including removal complete all as specified and directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, finishing even & rough to receive wearing surface complete all as specified and directed.
Sand filling under floors 25 mm thick each layer or in foundation including watering and consolidation for laying inter locking tiles/paver blocks, complete all as specified.
Machine pressed precast concrete interlocking paver block of any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 grade, laid jointed & pointed with grey cement and pigments, with & including 25mm thick sand filling under pavers and paking the joints of paver block with sand including watering and consolidation all as specified and directed by Engr-in-Charge. Note:-The shape, size and colour of paver block shall be as approved by EIC.
Plain Cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) for protecting interlocking tiles rounded or chamfered on edges complete all as specified and directed.
Bathroom mirror cabinet 400 x 500mm fixed to wall including complete accessories. Make : Prayag Cat Part No-554 or its Equivalent of Hindware, Cera as approved.
Pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs including use and waste of necessary formwork complete all as specified and directed.
Mild steel TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth as in foundation etc. and getting out in any type of soil, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 mm diameter incl fittings, complete all as specified and directed.
RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed.
Plain Cement concrete bed (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in concrete bed to150mm dia drain pipe including packing under and haunching against the side of the pipe after they are laid and tested including use and waste of necessary formwork, complete all as specified & directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified.
M&L for construction of Septic tanks including excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab in M-25 Design mix including RCC precast manhole cover with angle iron frame Vent shaft and sludge chambers etc., complete for 25 users, complete all as specified and shown on drg No CE/TD/1202/03 Sheet 1/2 & 2/2.
Soakage well exc in any type of soil, foundation in pcc 1:3:6,well of honeycombed and soil in M-25 concrete including intercepting champer,screen champer brick work in CM,RCC cover slab in M-25/RR masonary/filling with brick bats (size 2.4 M dia X 3.00M deep) Drg No CE/TD-1202/03 sheet 1/2 & 2/2.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 but except bricks, complete all as specified.
25 mm thick PCC 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate), as in levelling course finished even and rough complete all as specified and directed.
75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in bays complete including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling of AC corrugated or semi-corrugated in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed.
Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified.
Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
Pre-painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified.
35mm thick, IInd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified & as directed.
35 mm thick, 2nd class soft wood, glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and as directed.
250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified.
200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed.
03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
Mild steel framed work as in grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed.
Preparation of old steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint to match the existing surfaces complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed.
Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed.
Providing & fixing of 4mm thick designer ceiling board fixed with screw as per manufactures instructions, laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanized steel sheet & of size 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of Gl wire 4mm dia to be fixed by approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200 long cross tee with (double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300mm long of white colour all as per instruction complete all as specified & directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for theOne light point/fan /bell point controlled by one switch. (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One light point controlled by two way switch.
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing including taking down existing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Modular type switch 6 Amps, single pole,1 way, 240V with cover plate, ISI Marked Complete all as specified and directed. Makes of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved.
Modular type switch 6 Amps, single pole, 2 way, 240V with cover plate, ISI Marked Complete all as specified and directed.
Modular type switch 16 Amps, single pole, 1way, 240V, ISI Marked Complete all as specified and directed. Makes of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. Makes of Crabtree (Havells) or its equivalent in Anchor, Legrand, Seimens as approved.
Modular white cover plate with frame 1 module complete all as specified and directed.
Modular white cover plate with frame 2 module complete all as specified and directed.
Modular white cover plate with frame 3 module complete all as specified and directed.
Modular white cover plate with frame 4 module complete all as specified and directed.
Modular white cover plate with frame 6 module complete all as specified and directed.
Modular type socket 6 Amps /16 Amps, 2/3 Pin combined shuttered socket 2 module with cover plate with light indication ,240V,AC ISI Marked Complete all as specified and directed . Makes of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Seimens as approved by GE.
Fan regulator modular type electronic compatible suitable for BLDC fan, stepped type 100 Watts, 2 module with cover plate 240Volts, AC ISI marked complete all as specified and directed. “Cat part No ACVRFHW008 of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Seimens as approved by GE”.
Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed.
Modular Bell push 6A 1 module, 240V, ISI Marked Complete all as specified and directed. Makes of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Seimens as approved by GE.
Energy saving LED lamps retrofit type 12 watt, 230 volts, 50 HZ ,base holder B22 type. complete all as specified and as directed. Make- Havell Cat part No-LHLDDEHEML8R013 or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, Complete all as specified. Cat part No LW07-141-XXX-57 G1 Make Wipro or equivalent in Phillips, Crompton, Havells, bajaj as approved.
LED light fitting 1x10W, 220V, for mirror AC decorative type with driver holder high out put diffuser 2 feet including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make- Havell Cat part No-RUGBYGENXFTS10WLED865SSYMBOPC or equivalent of Make-Phillips, Crompton, wipro, bajaj as approved.
Supply and fixing in replacement integral sleek mounted LED fitting fixture (4 feet length), 18 watt with integral electronic driver complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size cable incl testing after fixing all as specified and directed by Engr-in-Charge. The specification of the light fitting should meet the following. (a) Housing of light fitting: Aluminum Extruded. (b) Operating voltage : 150V to 270V. (c) Operating temperature : 10 to 45 degrees. (d) Lumen efficacy : 100 lumen per watt. (e) System lumen : Not less than 1800 Lumens. (f) Colourtemperature : Not less than 5700K. (g) Surge voltage protection : Up to 2 KV. (h) Ingress protection : IP20. (j) Total harmonic distortion : Not less than 20%. (k) Power factor : Not less than 0.90. (l) Input frequency : 50 HZ. (m) Line protection : Under/Over voltage protection. "Cat Part No LL20-281-XXX-65-AL1 of Wipro, or its equivalent in Havells, GE, Oshram, Phillips”
35 Watt LED energy saving light fitting environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed. (Make- Havells, cat part No ENDURASUNDOWNSL35WLED765PASYBOPC or Bajaj/Philips/Crompton Greaves or its equivalent).
Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) including taking down old unsv fan, complete all as specified and directed. Make:- Cat Part No Zinger of Make Havells or its Equivalent cat part of make-BAJAJ,CROMPTON GREAVES, GEC, KHAITAN,ORIENT as approved by GE Note : Old unsv fans taken down shall be deposited with MES store yard and the same shall be entered in the register duly verified before making payment in RAR/Final Bill.
Sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp rated bus bar including blanking plates where required complete all as specified and as directed. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
MCB single pole & neutral 40 to 63 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSPF040or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
S & F in repairs, installation, commissioning and testing Polycarbonate CPRI approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. Contd to srl item No 165.01...
The gasket should be internally embedded made of polyurethane and Enclousers make Hensel/Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 100A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nos Operated by Flip Cover. Indicator Provided on each phase. Four Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 4 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel/Rittal/Emitter/Schneider.
Taking down existing unsv cable of size 16sqmm x 4 core all as specified and directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade of size 16 Sqmm nominal cross section x 4 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be recorded for payment putpose.
Taking up or down GI pipe incl fitting fixture of pipe size 50mm dia bore complete all as specified and directed.
Taking up or down GI pipe incl fitting fixture of pipe size 15mm dia bore complete all as specified and directed.
Taking up or down GI pipe incl fitting fixture of pipe size 20mm dia bore complete all as specified and directed.
GI tubing 50mm dia bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for GI tubing with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc all as specified and directed.
GI tubing 20mm dia 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for GI tubing with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc all as specified and directed.
GI tubing 15mm dia 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for GI tubing with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc all as specified and directed.
Cutting the existing 50mm tubing and inserting new GI Tee of size 50 x 50 x 15mm dia and including necessary screwing threading, tail pieces, short pieces, jointing material etc complete all as specified and directed.
Cutting the existing 50mm tubing and inserting new GI Tee of size 50 x 50 x 20mm dia and including necessary screwing threading, tail pieces, short pieces, jointing material etc complete all as specified and directed.
Modular type switch 10 Amps ,1 way, single pole, 1 or 2 module with cover plate, 240V, ISI Marked complete all as specified and directed.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
20 Watt LED batten/inverter capacity having charging time 8 hours, driver efficiency > 85% , power factor > 95% and operating voltage 270 volt with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable fixed in repairs complete all as specified and directed . (Make- Havells, cat part No LHEXACP7FN1W020 or Bajaj/Philips/Crompton Greaves or its equivalent).
Surface mounted square LED surface panel light capacity 12 watt downlight aesthetically designed aluminium housing expousre with constant driver all as specified and directed. Make HPL cat part No Jonex plus sq 12 watt WW or equivalent in Phillips, Wipro as approved.
25 Watt LED energy saving light fitting in replacement environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed. Cat Part No LR26-251-XXX-65-XX of Wipro or its equivalent in Havells, Philips, Bajaj, Surya, Crompton.
Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 8 way for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed. Make:- Legrand cat Part No. 5076 21 8 way / Hager cat Part No.VYS08G / L&T Cat Part No:-DBSPN008GD as approved
Supply & fixing and in repair MCB SPN 32 to 40 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed.Make:- Legrand cat No.4086 17 to 4086 18/ Hager cat part No:- NCN232N /Havells cat part No.DHMGCSNF040 / L&T cat part NoBB20400C as approved
Exhaust fan single phase metal body, AC 230 Volt, 50 Hz, 900 RPM of size 300mm sweep with louvers shutter complete with all accessories including connecting up from ceiling rose complete all as specified and directed. Make:- Cat part No:- Turbo Force 1P Grey of Havells or its Equivalent cat part of make-BAJAJ,CROMPTON GREAVES, GEC, KHAITAN,ORIENT as approved by GE
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 16 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
S&F GI bracket pipe of size 40mm dia medium grade of 1.2mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including suitable fabricate MS Flat iron clamps of 25x 6mm thick-02 Nos suitable for fixing any places with nuts, bolts and washers including grouting on wall etc and including removing of old unsv items complete all as specified and directed.
M/S Mahajan Construction Co.
PACHNANDA BUILDERS
M/S KARAN SINGH CONTRACTOR
M/s Sekinder Paul Sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .