Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.9 LAccepted-AOC 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹81.0 L+₹61,729 (0.77%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹82.0 L+₹1.6 L (2.04%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹83.0 L+₹2.6 L (3.25%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹84.5 L+₹4.1 L (5.10%)Rejected-Finance NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
29 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF CERTAIN SACTIONED WORKS AND CERTAIN MINOR WORKS IN DOMESTIC AS WELL AS TECHNICAL AREA AT AFS SULUR
2022_MES_566633_1
8535/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹1.5 L
Yes
9 Jan 2023
2 Dec 2022
30 Dec 2022
2 Dec 2022
29 Dec 2022
23 Dec 2022
2 Dec 2022 - 19 Dec 2022
Amount
SCHEDULE A BOQ
Surface dressing not exc 15 cm deep as in any type of soil all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil, complete all as specified and as directed.
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L Plain Cement Concrete 1:2:4 type B-1 (using 20 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , straight rough finished surfaces complete all as specified and as directed
M&L Rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
S & F mild steel framed work such as grills grating etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars, barrel iron doors ladders framed balusters walk ways railing frame work of water tanks and similar work confirming to Fe-410-O or Fe 310-O all as specified and directed.
M & L Preparation of new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Note for item No 9 :- (a) All synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L Brickwork with fly ash bricks using old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed
M&L Rendering 10 mm thick on brick or stone or concrete surfaces, in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L applying two coats of cement based paint including preparation of new plastered wall surfaces of any description, complete all as specified and as directed.
Supply, installation, commissioning and testing of Stainless steel Retro-fit Emission control equipment of size 500X500X2500 mm of weight 250 Kg able to capture specified particulate matter (PM 2.5) emitted from 125KVA stand by DG with capturing efficiency of minimum 90% and hold 5.5 kibipascal backpressure excerted by DG sets, with min operating Temperature (-)15 Deg celsius, Max operating Temperature 750 Deg Celsius, Operating Humidity up to 90% (Non - Condensing) corrsion resistive construction complete all as specified and directed. Location- Rubber Store/Rotable Division.
Supply, installation, commissioning and testing of Stainless steel Retro-fit Emission control equipment of size 500X500X2500 mm of weight 250 Kg able to capture specified particulate matter (PM 2.5) emitted from 100KVA stand by DG with capturing efficiency of minimum 90% and hold 5.5 kibipascal backpressure excerted by DG sets, with min operating Temperature (-)15 Deg celsius, Max operating Temperature 750 Deg Celsius, Operating Humidity up to 90% (Non - Condensing) corrsion resistive construction complete all as specified and directed. Location- Dornier Hanger.
Note for Item No 21 & 22 :- (a) The Retro-fit Emission control equipment shall be provided with pressure relieve valve, by- pass valve and other safety precautions to ensure no demage to be done to the engine operations under any circumstances.
(b)The Retro-fit Emission control equipment to be closely coupled with engine to ensure 100% for the exhaust passes through it.
(c) Anti-Vibration mountings is provided for complete Retro-fit Emission control equipment in case of flexible coupling with the diesel generator exhaust
(c) Retro- fit Emission control equipment shall be work whenever the DG set/engine is running to reduce/control particulate matter (PM-2.5) emission
(d) The storage tank shall be provided with piping (between storage tank and the Retro-fit Emission control equipment), valves, level indication and all standard accessories as per specification and direction of Engineer-in- Charge.
(e) The installation work of Retro-fit emission control equipment and its constituent parts shall be generally confirming to the extent possible, CPWD General specification for Electrical Works, Part- VII- latest.
(f) Interconnecting power and control cable between Retro-fit Emission Control device and DG set control panel shall be done by the contractor.
(g) The cable shall be ISI marked PVC insulated, armoured cable (FR Grade), with copper conductor rated voltage 1100 volts.
(h) The contractor shall be submitted warrenty for the equipment for a period of 12 months from the date of completion and shall be provided quarterly free service by OEM for a period 12 months from the date of completion
(j) The quoted rate is deemed to be inclusive for comprehensive maintenance of the equipment for a period of 12 months from the date of completion on quarterly basis only through OEM.
(k) Contractor shall be provided NABL accredited lab test report of complete product to prove the conformity of product as per specification and Emission Control Certificate from International Centre for Automative Technology, Manesar (Haryana).
(l) The contractor shall be sole responsible for any mishap/ accident during execution of work.
(m) Any loss or any damage to machinery/ equipments due to faulty operation/ mishandling shall have to made good by the contractor at his risk and cost. In the event of failure, suitable recovery shall be affected from the contractor’s bill for which decision of Accepting officer will be final and binding on the contractor.
(n) Necessary foundation for the equipment, if required shall be measured and paid seperately under relevent items here-in-after.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for laying XLPE cable, foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/ dense soil complete all as specified.
Note for Item No 37:- The quoted rate deemed to be inclusive for the following:-
(a) Excavating either straight or curved on plan
(b) Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance except in the case of surface dressing which includes for all the foregoing except clearing away of trees
(c) Bailing out, pumping out or otherwise removing all water which may accumulate in the excavations
(d) Setting out the work profiles, etc. as well as for all tools and plant
(e) All materials and labour required for protecting against risk of accidents, etc.
(f) Watching and lighting, whenever necessary.
(g) Forming (or leaving) ‘Dead men’ or ‘Tell tales’ in borrow pits and their removal after record of measurements where required
(h) Forming (or leaving) steps in sides of deep excavations and their removal or covering up, after record of measurements
(j) Excavation for insertion of planking and strutting where necessary
(k) Removing slips or falls in excavations
(l) Authorised battering or benching of excavations
(m) Slinging or supporting pipes, electric cables, etc. met with during excavation
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and as directed.
Note for Item No 53 :- In case sufficient sand not obtained from excavation, the required additional qty shall be obtained from out side MD land as directed by the Engineer-in-Charge and the rate is deemed to be included the above provision also.
Supply and lay fly ash bricks sub class B brick for cable protection size 23x11.5 x7.5cm complete all as specified and as directed.
M & L disconnecting existing incoming (01 No) and outgoing (04 Nos) cable connections carefully from the existing unserviceable VCBs and taking down complete with all accessories from the foundation all as specified and directed.
Supply, Installation, testing, and commissioning of Indoor type 11KV, 800 Amps, 25 KA, for 3 sec HT Vaccum circuit Breaker panel Board Indoor type 01 no incomer ,04 nos Out goings all as specified and as directed for main receiving station as per the below details . Make :- ABB/ Siemens /Schneider or equivalent as per PS
(a) 11 KV ,800 A ,25 KA Horizontal Draw out VCB fitted with Manual / motor operated spring charging mechanism with 230 V AC Motor & Motor control switch , Mechanical ON / OFF indication operation Counter , Automatic Safety shutters & Mech push Buttion
(b) Voltage Sensors , Sensors are Core -less devices, for Sensing Line Voltage in Medium Voltage System .
(c) 22 KV , 20 A to 415 A ,05 set current sensors , coreless type does not saturate , Rated current 250 A, Suited for load current of 20 A to 415 A
(d) 110V DC Auxiliary Supply , Numerical ,comprehensive feeder manager MF 90C with inbuilt features of protection / Measurement / Automation / cummunication /Kont rol, Maximum demand and control management , Feeder manger accepts Inputs from current and voltage Sensors ,10 protection group settings , 100 Fault records , 500 Event records with 120 simultaneous events facility in each record , 15 Digital Inputs , 8 Digital Outputs , with Digital CB Control , Front Universal Serial Bus (USB) Port can be used to connect to a laptop / personal computer . Rear end RS 485 Port also provided , protocol : IEC 60870-5-103 or Modbus
(e) Hooter (Dual tone ) 110 DC
(f) Aluminium Bus bar with PVC sleeve 11 KV ,800 A ,25 KA Earth Bus
(g) BATTERY BANK WITH CHARGER FOR AUXILLARY SUPPLY - 01 SET. Battery bank 24 volt consisting of 02 Nos 100 AH, 12 volts cells, maint free lead acid alongwith Racks & connections with suitable rating copper bus bar covered with PVC sheet and suitabale rating of float cum boost battery charger of rating 230 volt AC i/p, protection for i/p & o/p. 2 core, 10 sqmm, copper conductor un-armured cable (25 RM Approx) with crocodile clamps/lugs on ends from LT Panel to charger for 230 volts AC Supply and battery charger to VCB panel. Make of battery :- Exide/ Amaron / Luminous
(h) Heater ON/Off switch with filament type space heater & thermostat , single phase switch with socket , lamp for panel illumination with snap type door limit switch , fuses /MCBs for AC/DC control 240V
(j) MS Sheet steel enclosure of thick 3.1 mm & installation suitable for Indoor IP 54 / and power pack (230V AC /110V DC -2 Nos )
(k) Surge Arrester 9 KV , 10KA
(l) Castell interlock and Key (2 Base + 1 Key ) - 1 NO
(m) Cost of suitable base platform/foundation as per OEM recommendations is demmed tobe included in quoted rate.
The contractor shall submit guarantee certificates issued buthe manufacturers to the Engineer -in Charge.
Supply and fixing in repairs cable jointing kit 11KV grade cable for indoor termination Heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured all conductor cable of size 185 sqmm complete all as specified and directed.
Supply and fix in repairs cable jointing kit for 11 KV grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 sqmm, Indoor/Outdoor type complete all as specified and directed.
M&L Earthing complete with Copper earth plate electrode 60x60cmx3.15mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with copper earth strip 20mmx3mm thick and GI bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, ane provn of test point complete including dismantling of existing earthing all as specified and directed.
Note for Item No 73:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
(e) Copper strip 20x3mm upto 7.5 Mtrs shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately.
S&F in repair Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as directed.
Note fopr Item No 79 : All Joints should be joined by Exothermic Welding or Brazing.
M&L Un-reinforced precast concrete cable cover class HV Type 1, flat size 300mm x 180 mm x 40 mm thick including taking down existing cable cover complete all as specified and as directed.
Supply and laying in trenches/through pipes or bare in road crossings/paths/ drains/ ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11 KV grade, of cross sectional area 185 Sqmm x 3 core including taking down existing unserviceable XLPE cable complete all as specified and directed. Make : RPG Asian, Havells, Polycab
Note for Item No 82:- Excavation and earth work riddling sand, bricks etc shall be measured and paid seperately
Supply, installation, testing and commissioning of high quality standalone integrated full diffuser LED Troffer with a min system lumen of 3600 Lm (+/- 100 Lm tolerance) and system wattage not exceeding 36W (+/-5% tolerance) with an efficiency 100 lumen /watt. CCT of 6500K with SDCM of <5 and CRI >80. The housing should be of high quality CRCA & PS diffuser with PF > 0.95 and THD <= 10% input voltage range of 140-270V. Lifetime of 50000 hours @ L70. Product should be suitable for continuous operation (14-16)hrs per day)m. The LED light Engine (PCB) should be rectangular /square boards and not strip type, should be FR4 with 1mm thickness with more than 300 LEDs symmetrically mounted over it to maintain the potical and thermal stablity of the system over the life time. the sensor should be a motion detector and should be a connected with a digital interface to the led driver and it can be converted to a standard luminaire if this interface is not connected.(plug and play device) The time delay in the sensor should be min 15 (+5) mins. The coverage of the sensor should be 1.5m redius when installed in height of 8 ft. the luminaire should be class B serviceability (Driver needs to be seperate and can be changed at site. The same family of luminairy should be available in the both the version high Lumen (3600 Lm) and Low lumen (2800 Lm) . The LED used in the luminaire shall be of LG innotech, Lumileds APT Electronics , Nichia and CREE or equivalent. The driver should have min of 3KV surge/burst protection. Standby mode power of the system should be less than 1 watt avg. Driver should be protected for open circuit & short circuit protection for LED side. Make :Philips RC 383B LED 36S-6500 PSU OD WH PIR or similar in OSRAM/GE.Standby mode : when the occupency sensor has turned off the luminaire.
S & F CRCA housing of size 2'x2' suitable for mounting the LED light on ceiling with all accessories and fittings complete all as specified and directed.
M&L for point wiring with 1.5 Sq mm, FRLS, PVC insulated, single core, copper conductor cable, 1100 Volt grade, multi stranded in and including stove enamelled Steel Conduit pipe with and including continuous 1.5 Sqmm PVC insulated single core copper conductor cable earth continuity conductor connected to common earth and earth dolly all as specified and directed for the following:- Make of Wire : Plaza/ Polycab/ Havells or equivalent approved make.
One light point/fan point controlled by one switch.
One switch socket out let 5 Amps on independent board.
All as per item No 2 here in before but with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and fix modular switch 1 way, 6 Amp, 1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and fix modular switch 1 way 16 amp.1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and fix modular switch 1 way 16 amp.1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and fix modular metal flush box 3 module all as specified and as directed.
Supply and fix modular white cover plate 3 module all as specified and as directed.
Supply and fix modular metal flush box 2 module all as specified and as directed.
Supply and fix modular white cover plate 2 module all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl steel conduit of size 32 mm dia and all accessories fixed to wall/floors along with 2 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 98:- (a) 4 runs of 4 sqmm cable along with 2 runs of 4 sqmm cable for earth conductor and one run of steel conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for lamp holder PVC/ Polycarbonate type with cord grip suitable for pendent fittings complete all as specified and directed.
Supply and fix factory made powder coated distribution board SPN, 4 way single door including bus bar rated 200 Amps, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 complete all as specified and directed Make : Siemens/ Schnieder/ ABB or equivalent approved make.
S & F MCB SP 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified and as directed.
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified and as directed.
M&L XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 70 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, etc all as specified and directed.
Note for Item No 105 :- Excavation and earth work riddling sand, bricks etc shall be measured and paid seperately
M&L for earthing complete with Galvanised steel plate electrode of size 600X600X6 mm thick buried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground lvel, earth plate surrounded frm all sides by 15 CM thick packed alternate layers of charcoal dust and common salt,magnesium sulphate (1:1:5), electrode connections using GI strip of 32X6 mm thick (upto body of equipment) by means of brazing / welding connected to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40 mm dia boreand watering pipe 20 mm dia bore GI medium grade with funnel and wire mesh including all necessary (excavation & earth work, PCC chamber in PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical Plate No.3 of MES schedule part-1 (2009) testing on completion, complete including dismantling of existing earthing all as specified and directed.
Note for Item No 107:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Supply and fix IP 65 polycarbonate MCCB distribution board of size 680X420x160mm with polycarbonate hinges, complete with 4 pole, 100 Amp, 25 KA, 415 V MCCB conforming to IS :8623 and 4 pole, 63 Amp, 25 KA, 415V MCCB fitted with color coded sheathed bus bars RYB & Neutral bar, earth bar,DIN channel with IP 65 polycarbonate window for operation of MCCB without opening the enclosure. The enclosure should be dust & water proof with anti cracking, high temp resistant silicon sealing gaskets for weather proof outside mounting. It should be CE for safety of retardant UL 94 VO, UV resistant, Impact conforming to IEC60529, the enclosure should be suitable for wall/flush mounting. All hardware used should be made of SS304 Make:- L&T/ Schneider /Grasp
Supply installation, testing & commissioning of maintenance free chemical earthing consisting of copper bounded pre-welded electrode of 10 feet length, 17.2 mm dia made of high tensile low carbon steel rod with 250 micron (average) molecularly bounded copper on the outer surface confirming requirements of UL- 467 with exothermically joint together should be tested on 25 KA fault current with provision for connection clamp of size 150 mm long, 5 mm thickness with 12 mm dia hole of 4 numbers for termination on top of copper bonded rod along with 50 Kg eco friendly Back Fill compound with each earth rod including taking down old unserviceable earthing materials. The Back Fill compound should be tested to achieve 0.02ohms. The Back fill Compound should comply to IEC 62561-7 having passed leaching, corrosion, sulphur and resistivity test as per IEC-62561-7 by NABL accredited Lab, size of bore 6-8 inch, 11 feet depth, distance between each bore shall be 3 mtrs long the above installation shall be completed with 10 liters of Super Charger Earthing liquid tested by any NABL agreated laboratory tested as per IEC-62561-7, read with ASTM G57-06, CI 3.4.A. Make : ISG Global / SafeTrode/ Errico or equivalent
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (copper strip shall be measured and pair seperately .
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
M&L Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : ISG Global or equivalent make of SafeTrode/ Errico.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as specified and directed.
S&F epoxy base insulators of suitable size 40mm height for fixing copper earth strip on wall/ceiling/floor/poles etc complete all as specified and directed.
M&L for recharging of existing defective earth pit after excavation upto one feet depth of surrounding the earth pit as notified by the Engr-in-Charge by pouring the Earth Re-charger Hydrate Crystalline Gel Earthing Compound packing of 6 Kgs Bucket for each earth pit, it is a Water Soluble soil Reactivation Earthng Compound for earth resistence enhancement it can be used in all type of existing earth pits, the same will be enviromentally & metallurgically Safe, Non-Corrosive, eco friendly, and purity of the compound is 98-100%, the same will be effective for min 12 to 18 months. Make :- DSS or equivalent make as per specification
Note for Item No 135 :- Earth pit will be checked pre and post recharging the pit
Resistance after using the gel should reduced by 60-70%
Testing and commissioning shall be done by the contractor
devan enterprises
KUMAR AGENCIES
K T ASSOCIATES
LAKSHMI ELECTRICAL ENTERPRISES
SUPER COOL
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .