Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 1076 BEHERA SAHI NAYAPALLI BHUBANESWAR 751012 | KHORDHA | ODISHA | 751012 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance HOUSE NO HIG 4 3 HOUSING BOARD COLONY CHANDRA SEKHAR PUR BHUBANESWAR KHURDA ODISHA 751016 | KHORDHA | ODISHA | 751016 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.4 L
EMD Value
₹2,876
Closing Date
5 Mar 2026, 3:00 pmClosed
DIRECTOR NISER
NISER Bhubaneswar, Jatni
Provision for Power point installation, cable laying, Light and AC point fixing in the Utility-Cum-Store Room Behind Room 008, SPS
2026_NISER_900278_1
NISER/IWD-ELECT/SPS/25-26/14
Open Tender
Electrical Works
Works
15 days
NISER Bhubaneswar, Jatni
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2,876
Yes
6 Mar 2026
25 Feb 2026
6 Mar 2026
25 Feb 2026
5 Mar 2026
26 Feb 2026
Supplying and fixing following 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required along with 2 nos. of 32 Amp DP MCB. Make-Legrand/Hager/Schnieder/Havells
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make-Legrand/Hager/Schnieder/Havells
Supply and installationof 40 watt LED batten Light- Essential SmartBright, light weight and screwless linear batten with high efficacy for modern commercial applications. The luminaire comprises of extruded aluminum housing offering superior finish, long life and high transitivity polycarbonate diffuser for high efficacy and uniform lighting. IP40. BN170C LED40S-6500 PSU L120 (Philips/Sygnify)
Supplying and fixing of 6 Module Modular PVC Surface Flush Box with base and cover plate with 1 nos. of 6/16A socket outlet with 4 nos. of Modular switch including installation, fixing of switch and socket and connection.) in the surface. Make: Legrand (Mylinc/Myrius)
SITC of BLDC Ceiling Fan, White colour,1200MM Sweep with mounting bracket and extended mounting rod, S hook, Anchor Bolt as required. Make- Almonard/Crompton/Havells (Fan Efficiencia Prime BLDC Fan, Make- Havells)
SITC of 3phase, 415 Volt, 1400 RPM, Heavy duty Exhaust Fan of 380MM/14" Grey colour, Metal Exhaust Fan, 1400 RPM speed, to be fixed after cutting the wall surface. Make- Almonard/Crompton/Havells
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Make: Polycab/Universal/Finolex/RR
Supply & Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. Make: Polycab/Universal/Finolex/RR
Supply & Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. Make: Polycab/Universal/Finolex/RR
Supply & Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. Make: Polycab/Universal/Finolex/RR
Supply and fixing of following sizes of Casing Capping as per site condition (Size:- 38x16 mm) or Medium Class PVC conduit (Color-White) along with Accessories in surface/recess including cutting the wall and making good the same in case of making recessed conduit as required. Size:-Conduit Size:- 25 MM Dia , Make:- Precesion/ Kinjal/Modi Casing Capping Size:- 38x16 mm , Make:- Legrand/AKG/Panduit
Dismantling and reinstallation of three phase and single phase point complete with connections, testing and commissioning.
Rewiring for 2.5 sq.mm to 16 sqmm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
Tendernotice_2.pdf
PDF • 0.42 MB
BOQ_946277.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .