| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹37.4 L+₹2.7 L (7.86%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹37.4 L+₹2.8 L (8.08%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹38.0 L+₹3.3 L (9.58%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹40.3 L+₹5.7 L (16.5%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
5 Jun 2021, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
REPAIR AND REPLACEMENT WORKS TO EXTERNAL ELECTRIFICATION INFRASTRUCTURE, STEEL TUBULAR POLES, LT CABLES, LT PANESL, APFC PANELS, LT SWITCHGEAR AND CONNECTED ITEMS AT LRDE UNDER GE (I) R ND D (WEST) BENGALURU
2021_MES_437552_1
GE(I) R ND D (WEST)/BAN/02 OF 2021-22 8872E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BENGALURU
Not applicable. Refer NIT attached
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹96,000
Yes
27 Jul 2021
24 Apr 2021
12 Jun 2021
26 Apr 2021
5 Jun 2021
22 May 2021
26 Apr 2021 - 20 May 2021
Amount
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft / loose soil all as directed.
Returning and filling in, soils, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Demolition of plain cement concrete as in foundation base of transformers, poles, panels, sign boards, coping, etc including providing necessary supports to ensure that existing installation / poles / panels do not fall which demolition, removing of debris outside MD land complete all as directed by Engineer-in-Charge.
Material and labour for plain cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate as in mass concrete foundations of transformers, poles, panels, sign boards, etc., including necessary formwork, complete all as specified and as directed.
Material and labour for plain cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate as in coping to poles, panels, etc., including necessary formwork, complete all as specified and as directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
Material and labour for cushioning of river sand, for Cables in ducts of sub stations, complete all as directed and specified. Note : For the purpose of payment punned thickness will be measured.
Material and labour for laying of burnt bricks sub class `B’ bricks of size 230 x 115 x 75 mm, laid in trenches for cable protection all as directed and specified
Re-laying of burnt bricks sub class `B’ bricks in trenches for cable protection all as directed and specified Note : Serviceable brick covers obtained while excavating for replacement of unserviceable cables shall be reused under this item.
Taking out old unserviceable joints, Supplying, jointing new indoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 95 sq mm, testing, complete all as specified and as directed
Taking out old unserviceable joints, Supplying, jointing new indoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 185 sq mm, testing, complete all as specified and as directed
Supplying, jointing new Straight through cable jointing kit suitable for 11 K V, UG XLPE cable of size 3 core 95 sq mm, testing, complete all as specified and as directed
Supplying, jointing new Straight through cable jointing kit suitable for 11 K V, UG XLPE cable of size 3 core185 sq mm, testing, complete all as specified and as directed
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches, 50 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches, 80 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches, 150 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Preparation of old painted steel pole surfaces of 8.5 to 9 m long, applying zebra marking painting with two coats of synthetic enamel paint of approved make above ground level / coping 1.5 m height with alternate strip each of 30 cm width, silver and blue or any other colour, and remaining length with two coats of aluminium paint, painting pole terminal box, white wash to the coping etc., writing pole numbers on each pole to match with existing one, complete all as specified and directed .
Material and labour for writing letters of size up to 1.5 inch height, with exterior grade enamel water proof paint on panels / feeder pillar boxes, etc., including representing incoming and outgoing connections complete all as per directions of Engineer-in-Charge.
Material and labour for writing letters of size up to 2 inch height, with exterior grade enamel water proof paint on panels / feeder pillar boxes, etc., including representing incoming and outgoing connections complete all as per directions of Engineer-in-Charge.
Detection /localization of fault in HT 11 KV UG cable of any size and length, by means of cable fault locator including pinpointing the exact location of fault ,retrieving the exposing damaged portion carefully for further inspection and repairs complete all as specified and as directed . NOTES :- (i) Charges for cable fault equipment carried out by BESCOM/ other agencies are deemed to be included in the item rate quoted (ii) Contractor on demand by the department has to arrange the above equipment without any delay failing which necessary penalty will be levied by the department. (iii) HT cable, joints and earthwork shall be measured and paid for separately under respective items.
Taking out old unserviceable MCCB, Supply and fix, adjustable MCCB, 4 pole, 415 volts, 100 amps, 25 kA breaking capacity, making additions / alterations in MCCB panel compartment, complete all as specified and as directed.
Taking out old unserviceable MCCB, Supply and fix, adjustable MCCB, 4 pole, 415 volts, 160 amps, 25 kA breaking capacity, making additions / alterations in MCCB panel compartment, complete all as specified and as directed.
Taking out old unserviceable MCCB, Supply and fix, adjustable MCCB, 4 pole, 415 volts, 200 amps, 36 kA breaking capacity, making additions / alterations in MCCB panel compartment, complete all as specified and as directed.
Taking out old unserviceable MCCB, Supply and fix, adjustable MCCB, 4 pole, 415 volts, 400 amps, 36 kA breaking capacity, making additions / alterations in MCCB panel compartment, complete all as specified and as directed.
Taking out existing old or burnt or defective LT UG cable, including loop of under mentioned cable sizes from panels / ducts / trenches / loop etc., near the sub stations / poles / buildings / panels including disconnecting cables on both ends, tracing out the fault with the help of megger and other tests complete all as directed by Engineer-in-Charge. Note: i) Excavation and earthwork will be measured and paid for separately under respective items. ii) Serviceable brick covers shall be stacked aside for re-use.
All as per Serial Item No 26.00, but 1100 V grade XLPE Cable of size up to 4 Core, 25 Sq mm,
All as per Serial Item No 26.00, but 1100 V grade XLPE Cable of size 3.5 Core 35 Sq mm to 3.5 Core 50 Sq mm
All as per Serial Item No 26.00, but 1100 V grade, XLPE Cable of size 3.5 Core 70 Sq mm to 3.5 Core 95 Sq mm
All as per Serial Item No 26.00, but 1100 V grade, XLPE Cable of size 3.5 Core 120 Sq mm to 3.5 Core 185 Sq mm
All as per Serial Item No 26.00, but 1100 V grade, XLPE Cable of size 3.5 Core 240 Sq mm to 3.5 Core 300 Sq mm
All as per Serial Item No 26.00, but 1100 V grade, XLPE Cable of size 3.5 Core 400 Sq mm to 3.5 Core 630 Sq mm
Laying only serviceable cable of following sizes as per site requirement, connecting to existing cable with and including new lugs, complete all as specified and as directed by Engineer-in-Charge. Note : Serviceable cables obtained from Sl Item Nos 26.01 to 26.06 shall be reused under this item.
All as per Serial Item No 27.00, but 1100 V grade XLPE Cable of size up to 4 Core, 25 Sq mm,
All as per Serial Item No 27.00, but 1100 V grade XLPE Cable of size 3.5 Core 35 Sq mm to 3.5 Core 50 Sq mm
All as per Serial Item No 27.00, but 1100 V grade XLPE Cable of size 3.5 Core 70 Sq mm to 3.5 Core 95 Sq mm
All as per Serial Item No 27.00, but, 1100 V grade XLPE Cable of size 3.5 Core 120 Sq mm to 3.5 Core 185 Sq mm
All as per Serial Item No 27.00, but, 1100 V grade XLPE Cable of size 3.5 Core 240 Sq mm to 3.5 Core 300 Sq mm
All as per Serial Item No 27.00, but ,1100 V grade XLPE Cable of size 3.5 Core 400 Sq mm to 3.5 Core 630 Sq mm
Laying only cables of following sizes as per site requirement, in trenches / ducts / near the building / panels etc., connecting to existing cable with and including new lugs, complete all as specified and as directed by Engineer-in-Charge. Note : i) Cables will be issued under Schedule 'B' free for laying. ii) Necessary excavation and earthwork (as applicable) shall be measured separately under respective items.
All as per Serial Item No 28.00, but XLPE Cable 1100 V, of size up to 3.5 Core, 50 Sq mm,
All as per Serial Item No 28.00, but XLPE Cable 1100 V, of size 3.5 Core 70 Sq mm
All as per Serial Item No 28.00, but XLPE Cable 1100 V, of size 3.5 Core 95 Sq mm
All as per Serial Item No 28.00, but XLPE Cable 1100 V, of size 3.5 Core 120 Sq mm
Supply and laying New 1100 V XLPE LT cable, insulated, screened, bedded galvanized steel strip armoured heavy duty with aluminum conductor, of cross sectional area 630 sq mm 3.5 core with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, including necessary lugs, jointing and testing complete all as specified and as directed.
Supplying, jointing new Straight through cable jointing kit, epoxy type, suitable for 1100 V, LT UG XLPE cable of following sizes and testing, complete all as specified and as directed
All as per Serial Item No 30.00, but, 1100 V grade XLPE Cable of size up to 4 Core, 16 Sq mm,
All as per Serial Item No 30.00 but, 1100 V grade XLPE Cable of size 4 Core 25 Sq mm to 3.5 Core 50 Sq mm
All as per Serial Item No 30.00 but, 1100 V grade XLPE Cable of size 3.5 Core 70 Sq mm to 3.5 Core 95 Sq mm
All as per Serial Item No 30.00 but, 1100 V grade XLPE Cable of size 3.5 Core 120 Sq mm to 3.5 Core 185 Sq mm
All as per Serial Item No 30.00 but, 1100 V grade XLPE Cable of size 3.5 Core 240 Sq mm
All as per Serial Item No 30.00 but, 1100 V grade XLPE Cable of size 3.5 Core 300 Sq mm
Checking of old and existing out door LT feeder boxes of any size located at various locations, taking down old broken / corroded / damaged / dented LT Outdoor feeder box doors / sheets of any type and of area not exceeding 0.5 Sq m from existing positions carefully in and including addition / alterations to doors / hinges as per site requirement with repairing, denting, machining work, welding works, applying two coats of spray painting matching of existing colour to panel complete over a coat of primer as per panel site conditions, provision of pad locking arrangements, aldrops, pad lock with three keys, etc., for proper locking of doors / fixing of sheets complete all as per directions of Engineer-in-Charge. Note : i) The Contractor shall visit the site before quoting the rate in the tender. All spares required as per site requirement shall deemed to be included in quoted rate. ii) Cost of disconnecting, taking out cable from trench etc., reconnecting with new lugs as per site requirements shall deemed to be quoted in quoted rate, iii) PCC work shall be measured and paid separately under respective items.
Taking down GI / acrylic sign boards of any type and size from existing locations/ top of buildings / near the sub station buildings carefully, carrying out repairs to damaged portions matching with adjacent surfaces complete all as directed by Engineer-in-Charge. Note : Demolition of PCC supports / base and earthwork will be measured and paid under respective items.
Supply, fabricating and fixing, steel board stand made of 50 mm dia stainless steel heavy duty pipe of SS 304 grade, suitable for outdoor purpose as per site requirement for fixing Aluminium Composite Panel of various sizes duly lettered and emblems, fixed with nuts, bolts of screws or any other arrangement, along with frame of 20 mm dia SS pipe complete all as directed by Engineer-in-Charge. Note : Necessary excavation and earthwork, PCC for embedding pipes, 20 mm dia SS pipe for frame and ACP sheet will be measured and paid for separately under respective items.
Supply, fabricating and fixing, steel board frames, posts and connecting pipes made of 20 mm dia stainless steel heavy duty pipe of SS 304 grade, suitable for outdoor purpose boards, as per site requirement for fixing Aluminium Composite Panel of various sizes, fixed with nuts, bolts of screws or any other arrangement, complete all as directed by Engineer-in-Charge. Note : ACP Sheet will be measured and paid for separately under respective items.
Supply and fix, ACP sign board sheets of not less than 4 mm (2 mm sheets sticked back to back) of various sizes, including writing details of installations / machinery, both sides vinyl pasting on radium sticker with self glowing letters, emblems along with lamination on both sides as per directions of Engineer-in-Charge.
Supply, fabricate and fixing stainless steel hollow balls of dia not less than 50 mm on stainless steel stand complete all as directed by Engineer-in-Charge.
Checking of HT 11 KV, existing bus bar system of VCB unit consisting of one indoor and three out door units (indoor type) located at GM Sub station, supply fabricate and fixing HT 11 KV cable end joint box manufactured from CPRI certified panel manufacturer on the right side on outer body of the VCB unit in and including provision, addition / alteration and extension of suitable rating copper bus bar from existing VCB unit to new cable end box properly complete all as directed by Engineer-in-charge. (Location : GM Sub Station)
Disconnecting old unserviceable existing HT cable of size 185 Sq mm 3 core both ends from VCB Panels ducts carefully, taking down HT cable, meggering the cable, removing unserviceable cable end joint, supply and jointing HT heat shrinkable epoxy end joint with jointing material - 1 No of size 3 core 185 Sq mm and reconnecting HT cable to VCB panel from cable end box, testing complete all as specified and as directed by Engineer-in-Charge. (Location : GM Sub station)
Servicing and repairing of LT Air Circuit Breaker of any type and rating in and including replacement of non functional components, charging mechanism and all connected accessories, tightening of cable in / out connections all as per requirements complete all as specified and as directed by Engineer-in-Charge. Note : The quoted rate shall be inclusive of replacing of all spare parts for switching ON / OFF, functioning of charging mechanism and tripping mechanism in all respects and no extra amount will be paid in this regards.
Supply, install, test and commissioning of LT bus bar chamber (fabricated by CPRI certified and approved manufacturers), made out of 3 mm thick CRCA sheet steel enclosure outdoor cubical type (size 600 mm x 600 mm x 400 mm), double door with front and rear opening facility, tower bolt locking, pad locks - 2 Nos, Provn of earthing bolts and nuts with GI Strip, four side slanting canopy of roof top, dust, vermin, weather proof duly powder coated with seven tank process, IP-54, and all as per IE rules including mounted on MS angle iron frame of size 75 x 75 x 6 mm (1 m height 4 Nos) welded to shape, mild steel base frame with channels of size 75 x 75 x 6 mm, including necessary grouting with PCC 1:4:8 type D2 with 20 mm graded stone aggregate with legs 50 cm in ground and 40 cm above ground including necessary excavation and earth work complete with necessary compartments, fitted with TPN aluminium bus bar 600 Amps with colour code sleeves mounted on porcelain/SMC/DMC insulators, including provision of doors on front with neoprene gaskets, internal control wiring with PVC insulated copper wire. Note: The quoted rate shall deemed to be inclusive of connections of incoming & outgoing, UG cable, terminating with suitable cable end glands, aluminium lugs, excavation and earthwork, taking down old cable with LT switches complete all as specified and as directed.
Checking of copper / GI strip or GI wire earthing of any type near all E/M installations, by following all safety methods carefully, tightening of all earthing connections, pouring water in the earth pits through earth pit funnel, testing of earthing pit using earth tester after 24 Hours of water pouring. (The arrangement of earth tester is the responsibility of the Contractor), white washing to earth pit, marking & painting information of pit with exterior paint mentioning date of earth result checked, test results, to which equipment earthing pit pertains, complete all as directed by Engineer-in-Charge. Note : i) The job shall be paid twice in the contract period with interval of six month periodicity. ii) Earthwork, demolition of PCC, PCC new work, RCC earth pit cover and GI strip as applicable shall be measured and paid separately under relevant items.
Taking down broken RCC covers, providing material and labour, for Pre-cast Reinforced Cement Concrete, (1:2:4), type B1 using 20 mm graded stone aggregates as in cover slabs of earth pit, set in CM(1:4) complete all as specified and as directed. NOTE :- Steel for Reinforcement will be measured and paid separately.
Material and labour, for reinforcement of concrete with Mild steel TMT bars of 8 mm dia, cut to length, bent to shape required, including cranking, bending, spirally looping for columns, hooking ends & binding with and including mild steel annealed wire of not less than 0.9 mm dia or securing with clips complete all as specified
Demolishing old earthing pit, and providing new earthing pit with material and labour for earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth strip of 32 x 6 mm by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 50 mm bore (light grade) connected to earthing test point all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in cement concrete (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B-1, reinforced with 8 mm dia MS round bars @ 75 mm c/c both ways for cover and MS frame etc., and achieve resistance below 2 Ohm complete all as specified and as directed NOTES :- (i) The quoted rate deemed to include earth strip and protection pipe up to 7.5 metre from earth plate / earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Material and labour, Galvanized earth strip of size 32 x 6 mm earth continuity or main earthing lead fixed to Wall/ trenches /ducts / buried in ground (beyond 7.5 m through Galvanized iron pipe including necessary clamps, nuts, bolts, etc., and connecting up complete all as specified and as directed.
Fixing only, Galvanized earth strip of size 32 x 6 mm earth continuity or main earthing lead on Wall/ floors fixing with necessary clamps, nuts, bolts, etc., and connecting up complete all as specified and as directed.
Supply and fixing of synthetic Rubberized insulated mats, 2 mm thick, of size 2 m x 1 m, suitable to resist electric shock safety for voltage up to 3.3 KV as per IS 15652-2006 (superceding IS 5424), complete all as specified and as directed.
Supply and fixing of synthetic Rubberized insulated mats, 2.5 mm thick, of size 2 m x 1 m, suitable to resist electric shock safety for voltage of up to 11 KV as per IS 15652-2006 (super ceding IS 5424), complete all as specified and as directed.
Sahara Engineers
B5BUILDING SOLUTIONS
ARUNOTHAYA TRADERS
Meghana and Gowda Enterprises
Sai Ram Builders
Solar Electricals and Electronics
GS TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .