Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.3 L+₹2.4 L (10.6%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹25.5 L+₹2.6 L (11.5%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹28.1 L+₹5.2 L (22.6%)Rejected-Finance GANGA NAGAR NEAR TUSHARCHAKRA MISAMARI 784506 | SONITPUR | ASSAM | 784506 | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹29.2 L+₹6.3 L (27.5%)Rejected-Finance | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
Refer Docs
EMD Value
₹65,400
Closing Date
25 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE TENGA
HQ CWE TENGA PIN-900194 C/O 99 APO
SPL REPAIR OF BLDG NO P-21AND SPECIAL REPAIR TO HARDSTANDING OPP IOC DEPOT AT MISSAMARI UNDER GE MISSAMARI.
2020_MES_390578_1
8208
Open Tender
Civil Works
Item Rate
180 days
MISSAMARI
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
Yes
GE MISSAMARI
₹65,400
Yes
17 Feb 2021
28 Oct 2020
27 Nov 2020
28 Oct 2020
25 Nov 2020
11 Nov 2020
28 Oct 2020 - 9 Nov 2020
75 days
Amount
Demolition of cement concrete (unreinforced) of of any descriptions, in Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level, complete all as specified and directed.
Taking down cement plaster of any description on Brick Walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, remove dust, debries/rubbish etc complete all as specified and as directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
Taking down Shutter from the frame exc 1 sqm but n.exc 2 sqm and refixing after cutting in straight line to reduce the size in same opening complete all as specified and directed
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge.
S& F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed.
S& F Steel ventilators with top hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F Sheet glass frosted 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&Fin repair Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
M & L 75mm thick PCC 1:3:6 Type C2 using 40mm graded aggregate as in plinth protection complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L Marble of green shade other than white and black, 18 to 20mm thick (table rubbed and polished) in steps, bathroom self, corner (including necessary cutting chasing) jambs,pillars, window cills, cocking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed
M&L Glazed ceramic colour tiles of size 300 x 600- 7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed.
M&L machine cut Kota stone slab flooring 20-25mm thick , size not less than 550 x 550 mm over & incl. 15mm thick screed bed or bedding layer in CM 1:6 as in floor laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl. rubbing with mirror polish complete all as specified and directed.
M & L for Rendering 15mm thick in cement mortar 1:6 on INTERNAL fair faces of Brick walls or on concrete surfaces, finished even and smooth W/O using extra cement complete all as specified and as directed.
M&L 15mm thick rendering in Cement Mortar 1:4 on External Fair Faces of Brick Walls or on Concrete Surfaces plastered Surfaces Finished Even and Smooth without using Extra Cement with WPC complete all as specified and as directed
M&L Rendering 5mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc., plastered surfaces finished Even and Smooth, without using Extra Cement, complete all as specified and as directed.
Supply only Integral water proofing compound (WPC), conforming to IS and as approved, complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and directed.
M&L for White wash, three coats on new ceiling surfaces including necessary preparation of surfaces, complete all as specified and as directed.
M& L for complete removal of existing treatment by scrapping, wire brushing from walls and applying two coats of oil bound distemper including preparation of surfaces,complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer ,complete all as specified and directed.
M&L for Preparation old decorated plastered surfaces of wall and applying one coat of cement base paint all as specified and directed.
M &L Preparation of old wood and wooden based surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint.
M &L for preparation of new or previously untreated surfaces steel surface and apply two coat of synthetic enamel paint over a coat of red oxide primer all as directed.
M&L for preparing old steel surface and applying one coat of symthetic enamel paint, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any descriptions,as in roof padding(including APP membrane), chajjaas and similar items, complete all as specified and directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof Slab. (ii) Applying one coat of cold bituminous primer (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction and sealing the joints with application of cold bitumen. (iv) Applying Two coat of aluminum paint over the APP membrance .
S&F in repair PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, Singe Socketed, in any length with Rubber Ring Joints with and including all fittings like bend, tee, floor/gully trap. or junction etc fixed to Walls or laid in floors complete all as directed.
S&F in repairs PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, Singe Socketed, in any length with Rubber Ring Joints with and including all fittings like bend, tee, floor/gully trap. or junction etc fixed to Walls or laid in floors, complete all as directed.
Surface dressing uneven surfaces of natural ground/road berms not exceeding 15 cm deep in soft/loose soil, levelling the ground by filling the low laying patches of ground with the same soil, waering, well ramming to make the surface even and removal of surplus soil & vegetation not exceeding 50 mtrs complete all as specified and as directed.
M&L for scarifying or picking gravelled, macadam or bituminus macadam surface in area not exc 400 Sqm and depth exc 50mm and not exc 100mm depth, complete all as specified and directed.
M & L for 7.5cm thick (compacted thickness) WBM with coarse aggregates of grading 2 (63 to 40mm size) spread, rolled and consolidated to gradient and camber required with 8 to 10 tonne power roller (type of agg granite trap or basalt) complete all as specified and directed.
All as per item no. 36 here in before but except materials(use material received from above Item no. 35), complete all as specified and directed.
Rolling and consolidating formation Water bound macadam (except laterite, kankar and broken brick aggregates) using power roller exc 8/12 ton capacity including watering as necessary, complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block of any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 with grey cement and no Pigment and incl laid over 25 mm thick sand cushioning complete all as specified and directed.
M & L for providing precast cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in kerbs stone (150mm thick) or mud stops, rounded or chamfered on edges complete fixed in position & set in CM (1:4), complete all as specified and directed.
Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) of any description on batten/conduit complete with fittings /fixtures such as switches, sockets, ceiling rosse, fan regulators,bracket and making good disturbed surfaces of Ceiling, Walls, etc. so as to match the existing Finishes complete all as specified and as directed.
Taking out/down burnt/unserviceable Main Switches, DB's, Bus-bars Chambers including all Fittings & Fixtures, etc. from existing Main Board and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed. NOTE : Quoted Unit Rate against DB's will deemed to be included for taking out/ down of MCB SP/SPN/ TPN.
Taking down of existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down unserviceable UG Cables of any cross sectional area and connection of any description laying in trenches or fixing with wall or poles, complete all as specified and directed.
Taking down unserviceable Security light of any type including removing of all electrical connection carefully from pole, complete all as specified and directed.
M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant (FR) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping high grade of suitable size and its Accessories, mounted on PVC boxes of suitable size including fixing/ grouting sunken/surface as per Site requirement for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light Point controlled by One 1-Way Switch 5 Amp, complete all as specified and as directed.
All as per Item no.46 here in before but for One Ceiling Fan/Exhaust Fan Point controlled by One 1-Way Switch 5 Amp and Regulator, complete all as specified and as directed.
All as per Item no. 46 here in before but for for One 3 Pin 5 Amps Switch Socket Outlet Point controlled by One 1-Way Switch on Same Board, complete all as specified and as directed.
All as per Item no. 46 here in before but for One 3 Pin 5 Amps Switch Socket Outlet Point controlled by One 1-Way Switch on Independent Board, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant (FR) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping high grade of suitable size and its Accessories, mounted on PVC boxes of suitable size inluding fixing/ grouting sunken/surface as per Site requirement for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 2.5 Sqmm Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for 5/15 Amps Switch Socket Combination Point, complete all as specified and as directed.
S&F Switch Piano, Flush type, Single Pole, 1-Way, 5 Amps, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Socket Outlet, 2-in-1, Flush type, multi-purpose, 3 Pin, 5 Amp, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination, 2-in-1, Flush type, multi-purpose, 2/3 Pin, 5 Amp, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 2-in-1, Flush type, multi-purpose, 3/5 Pin, 5/15 Amp, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Ceiling Rose, Surface Bakelite of size 65x50mm, 3 Terminals, AC, 50 Hz, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator, Step type, Flush type, heavy duty, suitable to work on 230 Volt, AC supply and connecting up, complete all as specified and as directed.
S&F Lamp Holder Surface Bakelite with Back Plate insulated body suitable for Batten/Angle Fittings and fixed with Wooden Round Block, conforming to IS and connecting up, complete all as specified and as directed.
S&F LED ADORE 10 Watt with B 22 CDL 5 STAR LAMP with B22 base capacity 1200 lumen, complete all as specified and as directed. Make: LHLDEUEBML8Z010 orequivalent of Crompton Greaves/Bajaj/Havells.
S&F Sheet Metal Enclosure MCB VTPN, 6-Way double door ready to use DBs provided with vertical phase bus bars/neutral bars with shrouds/ earth bars/ sticking saddles/ cement spill protector/ color coded interconnecting wire set/ cable ties/ blanking plates and circuit identification labels with provision for 4pole MCCB 100A as incommer and SP/SPN MCBs as outgoing, complete all as specified and directed.
S&F Sheet Metal Enclosure MCB DB, SPN, 8-Way with 200 Amp rated Bus-bar, 240 Volt, Double Doors and connecting up, complete all as specified and as directed.
S&F MCB DP, 20 Amp, 240/415Volt for fixing on MCB DB’s, 10 kA, 50 Hz, 'C' Curve confirming to IS/IEC 60898 breaking capacity and connecting up, complete all as specified and as directed. Make: L&T, Cat No. BB20200B or Equivalent in Schneider/Legrand.
S&F MCB SP, 6 Amp, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz 'C' Curve confirming to IS/IEC 60898 breaking capacity and connecting up, complete all as specified and as directed. Make: L&T, Cat No. BB10060B or Equivalent in Schneider/Legrand.
S&F Wall mounted LED 18 Watts, Batten ttype T5 light fitting,230 volts with extruded Aluminium Heat Sink provided for Efficient Heat Dissipation and Intregrated Electronic Driver Connector Block, etc. complete with all Accessories internally pre-wired and neccessary mounting arrangements, and including provision of new 3 Core multi-stranded Copper Conductor of size 23/0.193 from Ceiling Rose to Fitting including Ultra bright LED polycarbonate(T8) tube(Single side connection) 4'X18watts with G13 lamp holder complete all as specified and as directed. Make:REGALBATTENT01X18DSBSWH for Batten fitting and Model - PHOTONULTRAE2.0121T8SSTL18WLED865SPC for T8 tubelight of Make -HAVELLS, Cat part no. LHLDCLXEUL83018,LHFYBPNIA1W022 or Euivalent make of BAJAJ/CROMPTON.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and pc COVER top OPENING separate driver compartment with IP 66 protection and impact resistance of IK07 with electronic driver of capacity 15watts with pre wired and necessary mounting arrangements and provision of new 3 Core multi-stranded Copper Conductor of size 23/0.193 from Ceiling Rose to Fitting and GI pipe bracket made out of GI pipe medium grade, 32 mm dia 1.5 mtr long bend to required shape complete all as specified and as directed. Make : HAVELLS, Model No. ENDURAPEARLSL15wled757sasytopcmp OR Equivalent Make of BAJAJ/CROMPTON.
Excavating in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & laying locally available, well burnt Sub-class ‘B’ Bricks, laying perpandicular to UG Cable laid in trenches over Sand Cushion as Cable Protection, complete all as specified and as directed.
Supply & laying LT UG Cable PVC insulated, sheathed and armoured 1100 Volt grade with Aluminum Conductor with necessary End Terminal/ Cable Glands as per Site requirement including connecting to Main Switches/ Cut outs MCB/MCCB with necessary Lugs after cutting to required length, cross sectional area 50Sqmm 3.5Core, laid in Trenches or passing through GI Pipe including Brass Cable Glands, Mild Steel Clamps, Bolts, Nuts, etc., complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
S&F Galvanised Iron Pipe 50mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
Fixing only Serviceable tubelight/decorative fitting of any type and make obtained from Item no. here in before including replacement of 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting, complete all as specified and directed.
Taking down Ceiling Fan/Exhaust Fan of any Sweep after disconnecting Electric Connection, keep in safe custody and re-hanging/re-fixing the same Position and electrically connecting up with and including Copper Conductor Cable of size 23/0.193 multi-stranded, 3 Core, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of Single Core 6.0 Sqmm PVC insulated Flame Retardant (FR) unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable drawn through and including concealed PVC Conduit, ISI marked and its Accessories including 1-Run of Single Core6.00 Sqmm PVC insulated insulated Flame Retardant (FR) unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, fixed on Walls, Ceilling, etc., complete all as specifed and as directed. NOTE : (a) Cost of PVC conduitg with all Fittings/Accessories will deem to be included in the Quoted Unit Rate. (b) Cables as mentioned in Schedule ‘A’ Items and 1-Run of PVC conduit with all Fittings/Accessories will be measured and paid as One Unit. (c) Sub-main Wiring will be measured PVC conduit only. Wire required for looping, etc as ordered will deem to be included in the Quoted Unit Rate.
M&L Earthing complete with Galvanised Steel Earth Plate Electrode 600x600x6mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0 mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) ‘light grade’ upto 1.0 Metre above the Floor Level of Building where Main Switch/DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc 150mm thick PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggregate), reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’ including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, complete all as specified and as directed.
M/S Krishna Construction Co.
M/S Yadav Corporation
M/S K.K.TRADERS
M/S B.N. Prasad
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .