Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAccepted-AOC | ₹5.1 Cr | L1 | Accepted-AOC L1 Tender |
| 2 | L2₹6.2 Cr+₹1.1 Cr (21.0%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹6.2 Cr+₹1.1 Cr (21.0%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹7.3 Cr+₹2.2 Cr (44.0%)Rejected-Finance | ₹7.3 Cr+₹2.2 Cr (44.0%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹8.4 Cr+₹3.3 Cr (65.2%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | ₹8.4 Cr+₹3.3 Cr (65.2%) | L4 | Rejected-Finance Other than L1 |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
23 Sept 2023, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer Navy Visakhapatnam Station Road Visakhapatnam-530 004
INCOMPLETE ITEMS OF PROVISION OF STORAGE AND PROCESSING FACILITIES FOR MK82 CHAFFS_FLARES OF P81 AIRCRAFT AT INS RAJALI ARAKKONAM INCLUDING RECTIFICATION OF DEFECTS
2023_MES_609872_1
88699 RandC
Open Tender
Civil Works
Lump-sum
180 days
Arakkonam
As per NIT
14 documents required · 14 mandatory
₹3,000
GE M NAS Arakkonam
₹5.5 L
Yes
Chief Engineer Navy Visakhapatnam
10 Nov 2023
20 Jul 2023
25 Sept 2023
20 Jul 2023
23 Sept 2023
11 Sept 2023
31 Jul 2023
Amount
SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XII: Note: Schedule 'A' Part-I to Part-XII are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lumpsum price worked out by the contractor for 'Buildings, Structures and Parking Shed' as listed in Schedule 'A' Part-I
Lumpsum price worked out by the contractor for 'SITE CLEARANCE/AREA DEVELOPMENT/ EARTHWORK EXCAVATION' as listed in Schedule 'A' Part-II
Lumpsum price worked out by the contractor for 'INTERNAL WATER SUPPLY'as listed in Schedule 'A' Part-III
Lumpsum price worked out by the contractor for 'INTERNAL ELECTRIC SUPPLY'as listed in Schedule 'A' Part-IV
Lumpsum price worked out by the contractor for 'EXTERNAL WATER SUPPLY'as listed in Schedule 'A' Part–V
Lumpsum price worked out by the contractor for 'EXTERNAL ELECTRIC SUPPLY' as listed in Schedule 'A' Part-VI
Lumpsum price worked out by the contractor for 'ROAD, HARDSTANDING ,PATH AND CULVERT' as listed in Schedule 'A' Part-VII
Lumpsum price worked out by the contractor for 'SEWAGE DISPOSAL]' as listed in Schedule 'A' Part–VIII
Lumpsum price worked out by the contractor for 'AREA DRAINAGE' as listed in Schedule 'A' Part-IX
Lumpsum price worked out by the contractor for 'LIGHTENING PROTECTION' as listed in Schedule 'A' Part-X
Lumpsum price worked out by the contractor for 'FIRE FIGHTING' as listed in Schedule 'A' Part-XI
Lumpsum price worked out by the contractor for 'COPPER EARTHING' as listed in Schedule 'A' Part-XII
Schedule 'A' Part-XIII (MISCELLANEOUS ITEMS) (TO BE QUOTED BY THE TENDERER IN BOQ):
INTERNAL ELECTRIC SUPPLY:
Energy efficient LED ceiling light fitting 08 watt, minimum 800 lumen output integral round shape, 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with sutiable size. Make : Philips/Bajaj/Havells/GE/ Wipro/Surya
LED security light fitting with tube 20W or minimum lumen output is not less than 2000 lumens, New generation Energy saving and environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LED's as source and HF electronic driver prewired with 1.5 Sq mm copper conductor cable upto connector including 1.5 Mtr long GI tubing medium grade 32 mm dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directed. Make: Philips/Bajaj/ Havells/GE/Wipro/Surya
Ceiling fans AC single phase 230V of size 1200mm sweep with complete set with fixtures, 5 star rating, metallic body complete all as specified and directed. Make : Havells/Bajaj/CG/Orient
Exhaust fan 300 mm sweep , metal body (Heavy duty), complete with louvers suitable for operation on 230V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubed surfaces etc complete all as specified and as directed. Make Havells/ Bajaj/ CG/Orient.
MCB vertical TPN DB 4 way 415V, 50 Hz double door, IP 43 protection with 200A rated bus bar for provision MCCB as incommer and MCBs for outgoing circuits complete, fill empty with blanks, making good the disturbed area complete all as specified and directed. Make: LEGRAND/ Siemens/ ABB/ C&S/ GE/ Schneider
MCB TPN 415V, 50Hz, 10KA of capacity 63 Amp. Make : Each LEGRAND/Siemens/ABB/C&S/GE/ Schneider
Flame proof LED tube light fitting 2x16 Watt or minimum lumen output is not less than 3200 lumens, 240 volts with complete drive all as specified and directed. Make : CG or equalent Sudhir/Baliga/Shyam (for Magazine and amunation wksp)
Flame proof well glass LED light fitting 100 Watt or minimum lumen output is not less than 10000 lumens with complete Fulham drive and all accessories, 240 volts with complete set all as specified and directed. (for magazine and amunation wksp) Make : M/s Sudhir cat No WG 1239 or equalent CG/Baliga/Shyam
Flame Proof LED bulk light fitting 40 Watt or minimum lumen output is not less than 4000 lumens, 240 volts with complete drive all as specified and directed. Make : CG or equalent Sudhir/Baliga/Shyam (for Magazine and amunation Wksp)
Energy efficient LED light fitting with tube 38 watt or minimum lumen output is not less than 3800 lumens, 230V surface mounted LED batten type with extruded aluminium/CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Philips/Havells/GE/Wipro
Flame proof MCB DB TPN 6 way as per IS with MCB TPN 63 A- 01 as incomer & MCB SP 16 Amps -02 Nos (Magazine 600LT AHU Room and Ammunition work shop (HTL) and steel phospetised powder painted with 200 amps rated bus bar 240 volts neutral link, making good the disturbed area as per existing surface complete. (For Magazines), Make : Sudhir/Baliga/Shyam
Flame proof MCB DB TPN 8 way as per IS with MCB TPN 63 A-01 as incomer and MCB SP 16Amps-08 Nos (Ammunition work shop(HTL lighting Circuit) and steel phospetised powder painted with 200 amps rated bus bar 240 volts netural link, making good the disturbed area as per existing surface complete. Make : Sudhir/Baliga/Shyam.
Flame proof MCB DB TPN 8 way as per IS with MCB TPN 63 A- 01 No as incomer and MCB SP 16 Amps-10 Nos (Magazine 600 LT) and steel phospetised powder painted with 200 amps rated bus bar 240 volts neutral link, making good the disturbed area as per existing surface complete. (For Magazines), Make : Sudhir/Baliga/Shyam.
Earthing complete with GI earth plate electrode 60cmx 60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/ dense soil., PCC 1:3:6 type C-1 as in pit, 20 mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe connected upto DBs and suitable C.I top cover with handle, funnel, strainer, charcoal and testing on completion all as specified and directed. Note: Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type B2 in pad and pit complete all as specified and directed.
Earthing complete with GI earth plate electrode 60cmx60cmx6mm thick, burried directly in underground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and include GI earth strip 32x6 mm alternate 5 layer ofn charcoal (250kg) & salt crystal (200kg) and top two inches layer with back filling compound (100kg) , in 40mm dia GI pipe light grade by means of nuts bolts, washer and necessary earth work in any type of soil , PCC (1:3:6) Type C-1 chamber and RCC (1:2:4) Type B-1 covers and watering pipe 20mm dia medium grade with funnel complete with mesh, refiling with black cotton soil , testing on completion all as specified and directed. Note -(i) Rate quoted deemed to be include necessary excavation and earth work in any type of soil with PCC type B2 chamber, RCC cover, reinforcement, removal of surplus soil, site clearance complete all as specified and directed.
(ii) GI Earth strip 32x6 mm, GI tubing light grade 40mm dia up to 7.5m deemed to be included the rate quoted by the contractor (iii) Beyond 7.5m the gi earth strip 32x6mm & GI pipe light grade 40mm dia shall be measured under the respective item of the schedule. Desired earth resistance shall be not less than one OHM ,if the desired result is not acheived, the earthing will be re done No Extra Cost. Earthing pit display boards made out of 3mm thick MS sheet of size 30x35 cm welded to 75 cm long 25x25x5 mm thick MS angle iron grouted in PCC 1:3:6 (using 20mm graded stone aggregate ) to a depth of 20 cm below GL and including applying two coats of synthetic enamel paint of approved colour over coat of red oxide primer on all exposed steel surfaces and writing the letter on plate for showing the details:- Earthing pit No: Date of measurements : Next due date: standard valve: valve obtained; ON testing after completion from test point.
EXTERNAL WATER SUPPLY:
Construction of Valve chamber of size 900x 900x 600mm (internal dimentions) including excavation of earth work in any type of soil,100mm thick PCC 1:4:8 type D2 as in foundation , made out of 230mm thick brick work in cement mortar 1 :6 with 15mm thick plastering in cement mortar 1:4 internally complete and upto 150mm below ground level for external faces with 100mm thick plain cement concrete 1:3:6 type C1 using 20mm graded aggregate as in coping, cover frame made up of 50x50x6mm and 3.15mm thick MS sheet as cover with two Nos of hinges and one No handle made out of MS round bar 10mm dia with neccssary locking arrangement including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of white wash on plastered surfaces complete all as specified.
EXTERNAL ELECTRICAL SUPPLY:
LED street light 24W of minimum 2400 lumens output pressure die cast housing with epoxy powder coated dark graphite with heat resistant puffend glass and IP 65 protection in and including GI tubing medium grade 25 mm dia of 1.5 mtr length bent to shape including flat iron clamps of 20x3mm- 02 Nos with nut bolts and washers complete all as directed. Make : Philips Cat No BRP20 1x24 HP LED or equivalent of WIPRO/K LITE/CG.
Junction box (weather proof) on street light pole made out of themoplastic of size 275 mmx 135mm x 110 mm size with 01 No four pole connector with nuts & bolts for 03 phase and 01 neutral and including provision of 01 No MCB SP 6 Amp with DIN Channel to control the pole light circuit with MS clamps made out of FI 32x4 mm for fixing the box to pole complete with nuts, bolts and washers including necessary cable connection with suitable size cable lugs, complete all as specified and directed. Make: Sintex/Hensel. Make for MCB: Legrand/Siemens/L&T
FLAT/ROUND cable weather proof PVC insulated PVC sheathed multistranded 1100 volts grade with copper conductor 3 core 2.5 sqmm from loop in box to street light fittings all as specified. Make: Finolex/Gloster/Polycab
CI cable route indicator of oval shape with letter embossed as LT or HT UG Cable fixed to MS Angle of size 40 x 40 x 6mm, 6 cm long embedded in PCC block of size 40 x 40 x 25cm (LxWxH) in PCC 1:2:4 type B1 using 20mm graded aggregate including painting of exposed steel surface all as specified.
Laying only, testing cable XLPE insulated screened PVC bedded galvanised steel strip (or) wire armoured electric power cable (heavy duty) 1100 Volts grade with strandard aluminium conductor of size 3.5 core 240 Sqmm all as specified.
Laying only, testing cable XLPE insulated screened PVC bedded galvanised steel strip (or) wire armoured electric power cable (heavy duty) 1100 Volts grade with strandard aluminium conductor of size 4 core 16 Sqmm all as specified.
Laying only, testing cable XLPE insulated screened PVC bedded galvanised steel strip (or) wire armoured electric power cable (heavy duty) 1100 Volts grade with strandard aluminium conductor of size 2 core 10 Sqmm all as specified.
ROAD, HARDSTANDING, PATH AND CULVERTS:
150mm compacted thickness wet mix macadam (WMM) laid/rolled in two layers (each layer 75mm thick compacted seperately) with slip form paver rolled, consolidated and compacted to required gradient and camber all as specified and directed .
FIRE FIGHTING:
Construction of Valve chamber of size 900x900x600mm (internal size) including excavation of earth work in any type of soil,100mm thick PCC 1:4:8 type D2 as in foundation, made out of 230mm thick brick work in cement motor 1 :6 with 15mm thick plastering in cement mortar 1:4 internally complete and upto 150mm below gorund level for external faces with 100mm thick plain cement concrete 1:3:6 using 20mm graded aggregate all around and reinforcement cement concrete slab 1:2:4 type B1 using 20mm size graded stone aggregate of size 95x95x5 cm thick with 10mm dia deformed bars @ 12 cm centre to centre on both the direction with 10mm dia mild steel handle 250mm long bent to shape and fixed with steel angle iron and flat iron including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of wihte wash on plastered surfaces complete all as specified.
Foam spray nozzle 63mm x 19 mm dia complete all as specified.
Atmospheric Foam tank concentrate tank 4500 Ltrs made out of stainless steel or carbon steel with thermoplastic internal lining., externally fire red epoxy coating with expansion dome including provisional inbuilt ladder, pressure guages, drain out valve arrangements, vent valve , filling connection, return connection, foam mixing arrangements in and inlcuding with Foam maker induction tank with angle iron frame work of 100x100mm with internal bracing placed on RCC pedestals of 01M height above GL including with all required accessories complete and initial filling of foam capacity complete all as specified and directed.
Fire hydrant stand post type for provision of single out let of size 63mm dia completed all as specifed.
COPPER EARTHING:
Earthing complete with copper earth plate electrode 60cm x 60cm x 3mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to copper strip of size 20 x 3 mm by brazing only earth strip protected with light grade GI pipe 40mm dia bore from copper earth plate electrode and upto in and including the earth test point made of gunmetal phosporous bronze of size 75x75x25 mm including 25mm bore water pipe medium grade GI tubing including GI Funnel, wiew mesh. alternate 5 layers of charcoal (100 Kg) & salt crystal (75 Kg) and top two inches layers with back filling compound (100Kg) including excavation in strata, refiling with black cotton soil above the back filling compound and removal of the excavated soil and depositing at the place where directed. PCC pit in PCC (1:3:6) Type C1 using 20 mm graded stone aggregate, RCC (M) cover 40mm thick in RCC (1:2:4) type B1 usign 20mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm C/C both ways including MS angle iron frame of 40 x 40x3 mm etc watering the earth pit to acheive earth resistance below 01OHM incl testing all as directed and specified. (for secondary ground). Note: Copper earth strip of size 20x3mm and GI Pipe 40 mm bore light grade up to 7.5 M length deemed to be included in the rate quoted by the contractor beyond 7.5 M copper strip of the size 20x3mm and GI pipe 40 mm bore light grade shall be measured and paid under the respective item of the schedule. 2. desired earth resistance shall be not less than OHM. 3. If the desired result is not acheived, the earthing will be re done no extra cost. earthing pit display boards made out of 3 mm thick MS sheet of size 30 x 35 cm welded to 75 cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC 1:3:6 (using 20 mm graded stone aggregated) to a depth of 20 cm below GL and including applying two coats of synthetic enamel paint of approved color over a coat of red oxide primer on all exposed steel surfaces and writing the letter on plate for showing the details : earthing pit No : date of measurement : Next due date : standard value : value obtained : on testing
after completion from test point the desired earth resistance shall be not less than 1 OHM. If the desired result is not obtain the earthing will be re done no extra cost.
CRANES:
Fixing only, testing and commission of flame proof crane of Capacity 3 Ton with Micro inching electrically operated track (EOT) O/H complete with necessary ISMB channels etc., as per drawing No. WD/2019(S)-HTL sheet No. 5/19 with Span 12.15 with long travel of 40.15 Mtr Hook at 4.5 Mtr hook operated for manual handling in case of power failure along with necessary accessories complete all as specified and directed (For Magazine). Notes:- (i) EOT crane parts issue under Sch 'B' free for fixing only (Appx - A1 to A3) (ii) Before quoting the contractor shall visit site and if any deficiency found like parts / Eqpts in addition mention above list appx to be included quoted rate. (iii) Any alteration required at site for fixing of girder and ISMB included in quoted rate (iv) Installation, commissioning and load test by state civil inspector charges deemed to be included in quoted rate (v) Any servicing and minor repair charges need against Sch "B" item as mentioned in Appx - A1 A3 deemed to be included in quoted rate (vi) Fixing only crane parts as Appx - A1 & A3 Supply and fixing crance parts as Appx - B1 & B3
All as per item No.41 here in before but of crane of 2 Ton capacity including crane and operative O/H complete with necessary ISMB channels etc., as per drawing No. WD/2019(S)-HTL sheet No. 10R/19 with span of 10 Mtr width and long span 16 Mtr with hook height of 3.5 Mtr (For HTL Wksp). Notes:- (i) EOT crane parts issue under Sch 'B' free for fixing only (Appx - A1 to A3) (ii) Before quoting the contractor shall visit site and if any deficiency found like parts / Eqpts in addition mention above list appx to be included quoted rate. (iii) Any alteration required at site for fixing of girder and ISMB included in quoted rate (iv) Installation, commissioning and load test by state civil inspector charges deemed to be included in quoted rate (v) Any servicing and minor repair charges need against Sch "B" item as mentioned in Appx - A1 A3 deemed to be included in quoted rate (vi) Fixing only crane parts as Appx - A2 & A3 Supply and fixing crance parts as Appx - B2 & B3
REFRIGERATION:
Refrigerator Electric Driven Single Phase 180 Ltr Cap Single door with all standard accessories, 5 star rating. Make:- Whirlpool,Samsung, LG.
Voltage Stablizer auto operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V and voltage stabilised at 230 V with accuracy of + of 2.5% of capacity 0.5 KVA, Make V-Guard, Volina
DEFECTS RECTIFICATION:
M&L for arresting roof leakage by dismantling roof tiles and removing existing APP modified polymeric membrane and applying hot blown bitumen of grade 85/25 @ 1.20 Kg/Sq.m. over the bitumen primer @ 0.50 Litrs./Sq.m. after cleaning of surface and duly laying new the APP modified polymeric membrane and applying another coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sq.m. over the membrane and finally S&F of hydraulically pressed cement concrete tiles of size 200x200x22mm tiles laid on 15mm thick CM 1:4 mixed with water proofing compound, jointed and pointed in CM 1:3 (thickness of joint n. exc. 5mm) complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of the existing treatment and applying two coats of acrylic distemper (ready mixed) having VOC content less than 50 gm/Litr. over one coat of primer including application of 3mm thick wall care putty after preparation of wall surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for cutting crack portion and repairing with two coats of Dr. Fixit crack x paste in 24 hours interval between the two coats and applying two coats of oil bound distemper over one coat of primer including application of 3mm thck wall care putty after preparation of wall surfaces complete all as specified and as directed by the Engineer-in-Charge. Note: 1. Dr. Fixit crack x paste shall be applied in to the crack with a sptula or putty knife and level the surface avoiding formation of cavities & bubbles during the application and shall be allowed to set for 24 hours and then the second coat shall be applied same as above and cured for 7 days. 2. The paste shall have the specific gravity of 1.40 + 0.02 gm/ml at 30o C, service temperature -15o C to +80o C, volume shrinkage 0.20% and water resistance-excellent.
M&L for preparation of old treated wall surfaces and applying one coat of camouflage pattern waether proof paint (exterior grade) as per existing pattern on wall/ roof complete all as specified and as directed by the Engineer-in-Charge.
M&L for filling the gaps between aluminium door/window and the wall by preparation of surfaces/joints and applying one component, self expanding and ready to use Polyurethane (PU) foam filler with CPC free propellents, of approved quality (SoudaFoam 1K or equivalent) with suitable spray guns etc. all as required at site complete all as specified and as directed by the Engineer-in-Charge.
M&L for cleaning of floor/wall tiles, granite, marble surfaces etc. duly washing all the tiles and marble portion using all the required cleaning materials (cleaning chemicals/ acid/solutions etc.) complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of old treated steel and iron surfaces and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for cleaning of old concrete surfaces duly washing surface with water, removing all the dirt and oil with turpentine and pressurised air and applying Dr. Fixit bonding agent in two coats over the surfaces and curing for 7 days all as required at site complete all as specified and as directed by the Engineer-in-Charge. Note: The bonding agent shall have the compressive strength of 60 N/mm2 at 7 days, tensile strength of 10.40 N/mm2 at 7 days, Flexural strength of 28.10 N/mm2 and pot life of 30-40 minutes at 30o C.
M&L for cable termination including supply and fixing of suitable size of cable gland for LT XLPE cable of size 3.5 core 240 Sq.mm., connected in outdoor type LT panel and nearest substation indoor panel (Tapping point) complete with necessary end termination, lugs, bolts & nuts etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L for provision of test point terminal block made of gun metal or phopsphorous bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws and necessary connection of aluminium strip with earth pit including protection pipe, brackets, screws etc. complete all as specified and as directed by the Engineer-in-Charge.
Labour only for testing of point wiring like insulation test, polarity test and resistance test including connecting and termination of wire with switches and light fittings with necessary T&P etc. for the following complete all as specified and as directed by the Engineer-in-Charge:
One light/bell point controlled by one switch.
One ceiling/wall/exhaust fan point controlled by one switch and regulator.
One 3 pin socket outlet 15 Amps switch socket on independent board with 2.5 Sq.mm. FRLS PVC insulated unsheathed copper wire and one run of 2.5 Sq.mm. FRLS copper cable for earth continuity.
Labour only for testing of point wiring for flame proof fittings with 1.5 Sq mm (Nominal area) PVC insulated and unsheathed multi stranded copper conductor, 1100 volt FRLS grade through and including concealed stove enamelled steel metallic conduit and metal conduit accessories medium grade minimum 20 mm size and its complete concealed including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity connected to earth dooly complete all as directed and specified for One light/bell point controlled by one switch.
Labour only for termination of MCB DB single pole and neutral 12 way sheet steel phospetised powder painted with 200 Amps rated bus bar 240 V nautral link,double door flush mounting type complete all as specified and as directed.
Labour only for termination of MCB DB single pole and neutral 6 way double door sheet steel phospetised powder painted with 200 Amps rated bus bar 240 V nautral link,double door flush mounting type complete all as specified and as directed.
M&L for provision of extended stud for MCCB 160 Amps, 3 pole 415V,50Hz,35KA of capacity for fixing in VTPN DB's 8 way complete all as specified.
M&L for necessary connection to Energy efficient LED light fitting with tube 19/20 watt or minimum lumen output is not less than 1900 lumens, 230V surface mounted LED batten type with extruded aluminium/CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make: Philips/Bajaj/Havells/GE/Wipro/Surya
M&L for necessary connection to Energy efficient LED light fitting (2'x2' size) with tube 36 watt or minimum lumen output is not less than 3600 lumes, 230 V recess mounting type including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make: Philips/Bajaj/Havells/GE/Wipro/Surya
M&L for necessary connection to Energy efficient LED ceiling light fitting 08 watt, minimum 800 lumen output integral round shape, 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with sutiable size. Make: Philips/Bajaj/Havells/GE/ Wipro/Surya
M&L for necessary connection to Energy efficient LED mirror light fitting with luminare 10 watt or minimum lumen output is not less than 1000 lumens 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make: Philips/Bajaj/Havells/GE/ Wipro/Surya
M&L for necessary connection to LED security light fitting with tube 20W or minimum lumen output is not less than 2000 lumens, New generation Energy saving and environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LED's as source and HF electronic driver prewired with 1.5 Sq mm copper conductor cable upto connector including 1.5 Mtr long GI tubing medium grade 32 mm dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directed. Make: Philips/Bajaj/Havells/ GE/ Wipro/Surya
M&L for necessary connection to Ceiling fans AC single phase 230V of size 1200mm sweep with complete set with fixtures, 5 star rating, metallic body complete all as specified and directed. Make: Havells/Bajaj/CG/Orient
M&L for necessary connection to Exhaust fan 300 mm sweep, metal body (Heavy duty), complete with louvers suitable for operation on 230V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubed surfaces etc complete all as specified and as directed. Make: Havells/ Bajaj/ CG/Orient.
K. VENKATESH NAIDU
C R R CONSTRUCTIONS
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .