Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹41.2 L+₹17,253.20 (0.42%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹45.9 L+₹4.9 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
21 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Spl repair to bldg No T-26, T-67 and T-68 Including certain minor and revenue work of AGE B/R Dett-B, Dett-III AND AGE E/M under GE 862 EWS
2023_MES_615730_1
GER-39/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Class D a(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹92,000
Yes
3 Nov 2023
25 Aug 2023
23 Sept 2023
25 Aug 2023
21 Sept 2023
7 Sept 2023
Amount
Sch 'A' Part-I (B/R works) Surface dressing n exc 15cm deep and getting out in soft / loose soil, complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, etc, or for shafts, wells, drain pipes laying of cables etc, n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base, foundation, filling and mass concrete complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4, complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:6 on fair / unfair faces of brick work or concrete surface, finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick or concrete surface (external surface) finished the surface even and smooth without using extra cement inlcuding water proofing compound (as per manufactures insutructions), complete all as specified and directed. Note: Rate of WPC to be including in the quoted rate).
M&L for rendering 5 mm thick on concrete surface in cement mortar 1:3 on ceiling, finished even and smooth with sagol cement ,complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening, complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M&Lfor hardcore using broken stone boulders not exc 63mm deposited spread and levelled in layers not exc 15cm thick watered and rammed to a true surfaces, complete all as specified and directed.
M&L for 75mm thick plain cement concrete, type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
M&L for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, complete all as specified and directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2020, complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 150 mm long of extruded section (ISI marked) ,complete all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel , complete all as specified and directed.
S&F for extruded aluminium alloy handles size 150 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for viterous china wash down water closet pan, white (pedestal pattern), complete and connection to single symphonic action type PVC flushing cistern 10 ltr capacity and fixed in floor with brass screw complete all as specified and directed by Engr-in-Charge.
S&F for vitreous China wash basin, white colour, flat back, size 550x 400mm with pedestal excluding taps, waste chain and plug and pocelan stopper but including brackets ,complete all as specified and directed.
S&F for brass cromium plated brass wash hand basin mixer for mixing hot and cold water for wash hand basin of 15mm dia screwed down for iron pipe, complete all as specified and directed.
S&F for 15mm bore brass chromium plated wall mixer , 2 in 1 for hot and cold water mixing and one for shower rose with shower rose 15mm including fixing to steel pipe or union and connecting to wall mixer, complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed, complete all as specifed and directed.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F for 15mm bore angle valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete as in repair all as specified and directed.
S&F for 15mm bore angle valve, cast copper alloy two way screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete as in repair all as specified and directed.
S&F for 15mm chromium plated cast copper alloy health faucet inlet to length 100mm fixed to angle valve with including decorative choice flexibel pipe, wall hanger etc complete as in repair all as specified and directed.
S&F for 15mm bore bib tap cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete as in repair all as specified and directed.
S&F for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
M&L for 110mm bore PVC (SWR) single cockets soil, waste and vent pipes in any length with or without ears with cement jointslaid in treanches and floors spun pipes,complete all as specified and directed.
M&L for 110mm bore PVC (SWR) tee or branch pieces single ordinary or inverted or with parrallel branches but fitted with oval acesses door,complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) cowl, complete all as specifed and directed by Engr-in-Charge.
S&F for stack clamps out of 50mm x 5mm Fl and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall and roof 150mm bore of pipe ,complete all as specified and directed by Engr-in-Charge.
S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe, complete all as specifed and directed.
S&F for chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange aluminium anodised including one pair of brass chromium plated brackets, complete all as specifed and directed.
S&F for soap dish including chromium plated brass screws and wooden cleats complete as specified and directed by Engr-in-Charge.
S&F for sheet glass shelf assembly consisting 5.5 mm thick, sheet glass shelf 12cm wide with chromium plated bracket guard and rainling 60cm long, complete all as specified and directed.
S&F for chromium plated toilet paper holder, fixed to wall with CP brass screws , complete all as specified and directed. Make : Jaquar / Hindware / Parryware.
S&F for glass corner shelf with tempered glass, stainless steel brackets and polished chrome finish rail , complete all as specified and directed by Engr-in-Charge. Make : Jaquar / Hindware / Parryware.
M&L for steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or portion framed and hung as gates, including pintel hinges, stops, hand made sliding bolt etc and similar work conforming to Fe 290 or E-165 work including welded fabricks frames, gate and framed truss etc, complete all as specified and directed.
M&L formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar work, in rough finished flat surface of concrete, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for reinforced cement concrete nominal mix, 1:2:4, type B-1 (20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns and the like, complete all as specified and directed
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete nominal mix, 1:2:4, type B-1 (20mm graded crushed stone aggregate) (20mm graded stone aggregates) as in columns, pillars, piers, post, struts and the like, complete all as specified and directed
M&L use & waste rough surface of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves, including sup-ports, overhangs etc also splays between floors and beam etc, also splays between floors and beams, etc for rough finished surface, complete all as specified and directed.
M&L for providing reinforced cement concrete nominal mix, 1:2:4, type B-1 (20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers roof kerbs or mud stops, gola, rounded or chamfered, lintels over 1.5m span, complete all as specified and directed
M&L formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete nominal mix, 1:2:4, type B-1 (20mm graded crushed stone aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like, complete all as specified and directed
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for plain cement concrete 1:3:6, type C-2 ,using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar (1:1) and tested ,complete all as specified and directed.
M&L for salt glazed stone ware gully trap, square or round mouthed P type, having size 150 x 150 mm fixed in position, complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregates as inmanhole cover fixed with cement mortar 1:6 including necessary formwork and moulds, complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3.4 section) in cement mortar 1:2:4, type-B-1 of smooth finished and reforming benching, complete all as specified and directed by Engr-in-Charge.
M&L for brick work using old size bricks sub class 'B', straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified and directed.
S&F for vitreous China water closet (squatt pan) Orrisa pattern 680x470 mm size pan, white, with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to flushing cistern with flush pipe, complete all as specified and directed.
S&F 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
surface excacation in hard / dense soil n. exc 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete, complete all as specified and directed.
M&L for chequered cement concrete tiles of size 20 cm x 20cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
S&F for vitreous china urinal, half stall type aqua seal premium quality including flush pipe inlcuding PVC waste pipe and outlet, complete all as specified and directed.
S&F in repair for 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with flush pipe of poluthylene of high density, complete all as specified and directed.
M&L for construction of soakage well 1.8m dia and 3.0 m deep for 10 users including excavation and earth work in any type of soil, PCC 1:3:6, type C-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of brick masonry in cement mortar 1:4, RCC cover slab in M-25, interconnecting pipes of RCC, complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for construction of LLDPE septic tank (conventional) of capacity 10 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8, type D-2 in foundation, vent shaft, connection etc for 10 users including returning , filling of soil at sides of tank, well ramming in layers and removing excavated surplus soil to a distance not exc 50m, complete all as specified and directed by Engr-in-Charge at site.
M&L for plain cement concrete type B-1 1:2:4, (using 20 mm graded crushed stone aggregates) in surface channels and drains complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc, complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed, complete all as specifed and directed.
S & F for waterless urinal kit by removing existing coupling including complete piping accesaries and cleaning of the existing pipe and making good to the disturbed area, complete all as specified and directed by Engr in Charge.
S&F vitreous china full stall waterless urinals white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including complete piping accessaries, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including connecting to waste pipe complete all as specified and directed.
S&F in repair for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor, or as in weep hole, complete all as specified and directed.
S&F in repair for 110 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F in repair for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor, or as in weep hole, complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor, or as in weep hole, complete all as specified and directed.
Excavating in over areas n.exc 1.5m wide and n.exc 1.5m in depth in hard and dense, for foundation, complete, all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
Description all as per srl item No. 85 above but except stone. NOTE: Old stone retrieved from demolition shall be used.
M&L for plain cement concrete 1:3:6 type C-1 (20mm graded crushed aggregate ) as in bond stone in stone walling set in Cement mortar 1:6, complete all as specified and directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm for lime or sand stone and joints, as specified, of random rubble walling, uncoursed or brought upto courses, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
M&L for broken stone or boulders hand packing (any thickness) at back of well over arches etc and raising (for lowering) to the reqd level, complete all as specified and directed
Excavating in over areas n.exc 1.5m wide and n.exc 1.5m in depth in hard rock, for foundation, complete, all as specified and directed.
M&L for plain cement concrete 1:3:6 type B-2 (40mm graded crushed aggregate ) as in surface channels and drains, complete all as specified and directed.
M&L for add or deduct for each 25mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred / stopped ends, complete all as specified and directed.
M&L for vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling old tiles, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4 after dismantling old unserviceable of tiles, complete all as specified and as directed..
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:3 including dismantling of old tiles, complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, beams, staircase, chajjas and similar suspended work, complete all as specified and directed by Engr-in-Charge.
M&L for formwork to edge of concrete flat, treads, breaks in floors, window cill opening in conrete wall asn similar work exceeding 5 cm wide and not exceeding 10cm wide, complete all as specified and directed by Engr-in-Charge.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick wall / stone wall or concrete work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening including a coat of 3mm thick wall care putty, complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying one coats of distemper oil emulsion over a coat of chalk whitening, complete all as specified and directed.
M&L for preparation of new plastered surfaces of brick / concrete / plastered / unplastered surface of wall, pillars, cornices etc and applying two coat of white wash one coat of chalk whiting, complete all as specified and directed.
M&L for prepartion of new plastered surface and applying two coat of exterior weather proof paint of Apex ultima of Asian or equivelent make over and including a coat of primer, complete all as specified and directed.
Complete removal of existing treatment of wall/roof surfaces including cornices and chajjas etc and applying two coats of apex paint over one coat of primer, complete all as specified and directed by Garrison Engineers.
M&L for preparation of old decorated brick / concrete plastered / un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on walls, pillars, cornices etc, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing from site, complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-1 using 20mm graded stone agregate complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for steel windows box type with side hung shutters including bore type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for steel windows box type with side hung shutters including projecting type hinges with steel handle, hold fast and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares n . exc 0.50 sqm in each pane complete after hacking out old broken glass all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
M&L for preparation of old steel surface exc 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old wooden surface exc 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
S&F in repair for stainless steel curtain rod of 20mm dia, complete all as specified and directed.
S&F for bracket and finials of stainless steel of 'T' and 'L' type (colour and design approved by GE) for curtain rod stainless steel 20mm dia including fixing to walls with MS full screws (including fixing of wooden pieces of required size of walls) complete as in repair all as specified and directed .
M&L for 300mm long (lenth of bolt) aluminium alloy, anodised, sliding door bolt with hasp, stapl (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruced sections or cast aluminium alloy anodised (ISI marked) complete all as specified and directed.
Taking down old unserviceable GI pipe of 15 /20mm bore with all fittings etc, complete all as specified and directed.
S&F in repair for 15mm bore bib tap cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete as in repair all as specified and directed.
S&F in repair for 15mm bore angle valve, cast copper alloy, fency type screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete, all as specified and directed.
M&L in repair for 15mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
M&L in repair for 20mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
S&F for 32mm dia waste coupling PTMT (half or full threaded), minium weight 60 gms) fixed to stainless steel sinks / WHB, complete all as specified and directed.
S&F in repair for brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long with and including one pair of brass chromium plated bracket, complete all as specifed and directed.
S&F in repair for 125 mm dia PTMT grating doom stainless steel with waste hole for waste pipe (minium weight 40 grm), complete all as specified and directed.
S&F in repair for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
S&F in repair 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair for vitreous China wash basin, white, flat back, size 550x 400mm excluding taps, waste chain and plug and pocelan stopper but including brackets ,complete all as specified and directed.
S&F in repair for 15mm bore pillar taps, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete, all as specified and directed.
S&F in repair for soap dish including chromium plated brass screws and wooden cleats complete as specified and directed by Engr-in-Charge.
S&F in repair for (EWC) viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified and directed.
S&F in repair for copper alloy chromium plated jet spary suitable for padestal pattern WCs inlcuding decorative choice flexible pipe fixed to iron pipe with including cover plate, complete all as specified and directed.
S&F in repair for copper alloy chromium plated two way bib cock fixed to iron pipe with and including cover plate, complete all as specified and directed.
S&F in repair for vitreous China water closet (squatt pan) Orrisa pattern 580x440 mm size pan, white, with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to flushing cistern with flush pipe, complete all as specified and directed.
S&F in repair for 32mm dia PVC flush pipe of polythylene of low or high density low level cistern complete all as specified and directed.
S&F in repair for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed, complete all as specifed and directed.
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing ceiling board etc, complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Dismantling of timber fillets, rails, posts, rafters purlin etc under 40 Sqm cm in section, complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or portion framed and hung as gates, including pintel hinges, stops, hand made sliding bolt etc and similar work conforming to Fe 290 or E-165 work including welded fabricks frames, gate and framed truss etc, complete all as specified and directed.
M&L for coloured chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar 1:4, including dismantling of old tiles with cement mortar badding (but not the backing) and removing rubbish off the permises, complete all as specified and as directed.
M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litre of emulsion per aquare meter of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square meter of vertical surface (Area of sub structure in contact with back fill to be measured), complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface area, complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area, complete all as specified and directed.
Sch 'A' Part-II (E/M works) S&F for 25 mm bore galvanized steel water tubing medium grade with all fittings such as bends, socket, tee, elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
M&L for cutting, threading and inserting tee for taking new branch connection from existing pipe line of any size for the pipe size 25mm , complete all as specified and directed by Engr-in-Charge.
M&L for 25mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes and fixed, complete all as specified and directed.
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mmx115mmx75mm over the cable abutting each other, complete all as specified and as directed.
M&L for 40mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
S&F for exhaust fan of 300mm sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase with PVC body (sturdy engineering plastic body) with all accessories and louver etc with copper winding complete all as specified and directed.
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electrically operated suitable for 230 volts, 50 hz, AC supply system complete with porcelain/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
M&L for point wiring for geyser controlled by one-one way switch with 2.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC conduit medium grade of 20mm width complete with all accessories including PVC sunk box ISI marked for mounting of one 5 pin 15 Amp socket outlet independent 3 mm thick plastic laminated sheet as top cover, and 2.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the disturbed surfaces complete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
S&F for switch socket outlet combination 2 in 1, 5 pin, 5 amp flush type complete all as specified and directed.
M&L for 15mm bore stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type,screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F for PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC casing caping medium grade of 25mm width complete with all accessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the disturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 174 above but for one 3 pin 5 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 174 above but for one 3 pin 5 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 174 above but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistrand copper cable with 2.5 sqmm single core multistrand FRLS copper cable as earthing lead complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
S&F for switch socket combination 2 in 1, 3 pin, 5 amp flush type complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
M&L for switch socket outlet multipurpose 2 in 1, flush type single pole, one way 5 &15 Amp, 240 volts, complete all as specified and directed.
S&F for ceiling rose 3 phase / PVC / polycarbonate isolated body surface bakelite 2 to 3 terminals complete all as specified and directed.
M&L for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
Taking down,ceiling fan, exhaust fan/ pedestal fan sealing cable end, dismantling blades and removing fan and blades to store and painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, completed all as specified and directed.
S&F in repair for exhaust fan of 300m sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase with PVC body with all accessories and louver etc complete all as specified and directed.
S&F in repair for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 7 / 9 watt complete all as specified and directed.
M&L in repair for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed.
S&F for MCB distribution board SPN 4 way, double door 415 volts duly painted with epoxy based powder coated painting suitable for mounting MCB TP/FP as incomer and outgoings complete with busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate with IP 42 protection including removing old unserviceable item complete as in repairs all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole & neutral 240 volts any rating from 6 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for outgoing cables complete all as specified and directed.
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F for LED street light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down existing cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Supply installation testing and commissioning of Electrical Operated 240 volts 50 Hz, commercial RO UV Plant Stainless steel including cost of civil works complete system of purification capacity 500 LPH including all required accessories and fittings as mentioned:- (i) Raw water pump 0.5 HP CRI/LEO/V-Guard. (ii) Sediment Filter 13/54 Pentair. (iii) Carbon Filter 13/54 Pentair (iv) Multi Port Value 25 NB initiative (v) Jumbo filter big blue 2 piece (vi) High pressure pump CRI/LUBI/LEO 2/9 (vii) Dosing pump 6 LPH (viii) Flow meter 1200, 2400 (ix) Pressure gauge= 7 Kg , 21 Kg (x) Membrane housing UKL 40*80=1 (xi) Membrane 40*40=2 (xi) Automatic panel astero (xii) Stand fully stainsteel 1000 LPH (xiv) Fittings CPVC complete with tap (xv) UV Lamp Note: (i) Cost for all electrical connection from DB to the plant requried for functioning of RO plant in included in the quoted rate. (ii) Cost of GI pipes & fittings required and connections upto the filtered water storage tank is included in the quoted rate.
Supply and fixing 1100 volts grade heavy duty cable pvc insulated aluminium conductor served with inner sheathing of PVC tape and overall pvc sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm of suspension wire for a cable of size 16 sq.mm 4 core standard conductor complete all as specified and directed.
M&L for MCB triple pole & neutral 240 volts any rating from 32amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA, including providing thimble for outgoing cables complete all as specified and directed.
M&L for 40mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
M&L for 25mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
S&F in repair for 40 mm bore galvanised steel GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, three phase naturally air cooled indoor type & designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ± 2.5% and of capacity 5.0 KVA, complete all as specified and directed.
M&L for cutting the existing 50mm tubing and inserting new GI tee of size 50 x 50 x 25mm dia and including necessary screwing threading, tail pieces, short pieces, jointing material etc, complete all as specified and directed by Engr-in-Charge.
M/s Anil Engineers & Builders
SATVIR GUPTA ENGINEER and CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .