| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 CrAccepted-AOC | ₹13.9 Cr Quoted ₹14.0 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹15.9 CrRejected-Finance | ₹15.9 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹16.8 CrRejected-Finance | ₹16.8 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹17.5 CrRejected-Finance H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | ₹17.5 Cr | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹17.6 CrRejected-Finance | ₹17.6 Cr | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/s Khanna Enterprises L2 | ENGINEER CONSTRUCTION PVT. LTD. L8 | M/s. Shiva Engineers L7 | M/S Shiv Shakti Enterprises L10 | SHREE GURU NANAK CONSTRUCTION COMPANY L4 | RAJENDER ENTERPRISES L5 | Brahma Infra L6 | SOM BUILDERS L3 | M/s Azure Infrastructure Construction Co. L11 | yogesh kumar contractor L1 | Jasraj & Company L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.00NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. | ||||||||||||||
| 1.00 | Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 11,00,00,000 ₹11 Cr | 12,50,00,000 ₹12.5 Cr | 11,85,00,000 ₹11.8 Cr | 11,94,00,000 ₹11.9 Cr | 11,55,00,000 ₹11.6 Cr | 11,75,00,000 ₹11.8 Cr | 11,70,00,000 ₹11.7 Cr | 11,00,00,000 ₹11 Cr | 13,45,00,000 ₹13.4 Cr | 9,92,51,616 ₹9.9 Cr | 12,98,00,000 ₹13.0 Cr |
| 2.00 | Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 15,00,000 ₹15 L | 17,50,000 ₹17.5 L | 15,00,000 ₹15 L | 21,50,000 ₹21.5 L | 18,77,000 ₹18.8 L | 16,47,500 ₹16.5 L | 18,50,000 ₹18.5 L | 18,90,891.43 ₹18.9 L | 15,50,000 ₹15.5 L | 15,10,000 ₹15.1 L | 18,90,000 ₹18.9 L |
| 3.00 | Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 2,25,000 ₹2.3 L | 1,83,000 ₹1.8 L | 2,25,000 ₹2.3 L | 2,65,000 ₹2.6 L | 2,77,000 ₹2.8 L | 2,01,500 ₹2.0 L | 1,83,000 ₹1.8 L | 1,91,740 ₹1.9 L | 2,10,000 ₹2.1 L | 1,50,000 ₹1.5 L | 2,00,000 ₹2 L |
| 4.00 | Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 85,00,000 ₹85 L | 91,00,000 ₹91 L | 80,00,000 ₹80 L | 94,75,000 ₹94.8 L | 94,44,000 ₹94.4 L | 84,50,000 ₹84.5 L | 90,00,000 ₹90 L | 85,00,000 ₹85 L | 90,00,000 ₹90 L | 1,14,80,000 ₹1.1 Cr | 82,00,000 ₹82 L |
| 5.00 | Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 22,50,000 ₹22.5 L | 21,00,000 ₹21 L | 31,00,000 ₹31 L | 33,45,000 ₹33.5 L | 24,47,000 ₹24.5 L | 23,65,000 ₹23.6 L | 24,00,000 ₹24 L | 31,19,429.33 ₹31.2 L | 34,55,000 ₹34.5 L | 23,90,000 ₹23.9 L | 26,00,000 ₹26 L |
| 6.00 | Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 2,00,000 ₹2 L | 2,38,000 ₹2.4 L | 2,00,000 ₹2 L | 2,75,000 ₹2.8 L | 2,51,000 ₹2.5 L | 1,97,500 ₹2.0 L | 2,00,000 ₹2 L | 2,50,000 ₹2.5 L | 2,85,000 ₹2.9 L | 1,90,000 ₹1.9 L | 1,90,000 ₹1.9 L |
| 7.00 | Lump sum price worked out by the tenderer for FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 18,00,000 ₹18 L | 16,50,000 ₹16.5 L | 22,00,000 ₹22 L | 21,87,000 ₹21.9 L | 17,44,000 ₹17.4 L | 19,45,000 ₹19.4 L | 20,00,000 ₹20 L | 22,00,000 ₹22 L | 24,10,000 ₹24.1 L | 23,10,000 ₹23.1 L | 16,50,000 ₹16.5 L |
| 8.00 | Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 4,50,000 ₹4.5 L | 5,00,000 ₹5 L | 5,25,000 ₹5.3 L | 6,50,000 ₹6.5 L | 7,50,000 ₹7.5 L | 4,87,500 ₹4.9 L | 5,00,000 ₹5 L | 6,50,000 ₹6.5 L | 5,80,000 ₹5.8 L | 4,10,000 ₹4.1 L | 5,50,000 ₹5.5 L |
| 9.00 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) | 1 | Lump Sum | 25,00,000 ₹25 L | 23,00,000 ₹23 L | 28,55,000 ₹28.6 L | 30,00,000 ₹30 L | 27,40,000 ₹27.4 L | 23,65,000 ₹23.6 L | 24,10,000 ₹24.1 L | 26,06,884.99 ₹26.1 L | 28,81,000 ₹28.8 L | 22,80,000 ₹22.8 L | 21,00,000 ₹21 L |
Tender Value
₹12.4 Cr
EMD Value
₹9.5 L
Closing Date
4 Sept 2025, 6:00 pmClosed
Chief Engineer Bathinda Zone
Headquarters Chief Engineer Bathinda Zone Military Engineer Services PIN- 900484 C/o 56 APO
PROVN OF OTM ACCN AT GE OFFICE COMPLEX AT SRIGANGANAGAR MIL STN
2025_MES_720290_1
84486 CA NO CE BTZ/SGNR/TOKEN 26 OF 2025-26
Open Tender
Civil Works
365 days
GE Sriganganagar
As per NIT
8 documents required · 8 mandatory
₹3,000
GE Sriganganagar
₹9.5 L
Yes
Headquarter Chief Engineer Bathinda Zone
30 Sept 2025
14 Jul 2025
6 Sept 2025
14 Jul 2025
4 Sept 2025
29 Aug 2025
14 Jul 2025 - 1 Sept 2025
25 Jul 2025
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES AND AIR CONDITIONING as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for DEMOLITION as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately)
Schedule 'A' Part-XIII(FURNITURE)
Almirah small steel as per drawing No. FD-1032 sheet No. 1/1
Book case (steel) as per drawing No. FD-1028 sheet No. 1/1
Executive chair revolving of Make:- Godrej, Model No:- ELITE0001 or equivalent of Methodex, Geeken as approved by the GE
Chair Writing as per drawing No. FD/E6/MAP/12 sheet No. 1/1
Board Notice/Display Board of size (900 mm X 1200 mm) of Make:- Alkosign, Model No:- ASGPB 90120 or other equilent make as approved by the GE
Drugget of variety No. Wollen, 60 tex X 12 warp, size 3000 mm X 2000 mm as per IS 697: 2005
Hat stand with mirror (large) as per drawing No. FD-362 sheet No. 1/1
Side rack with tray three spaces (steel) as per FD-1023 Sheet No. 1/1
Sofa set single seater as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2
Stool 305 mm X 305 mm X 510 mm (steel) as per drawing No. FD-81(M) sheet No. 1/1
Table officers (steel) as per drawing No. FD-1003 sheet Nos 1/2 & 2/2
Table Centre as per drawing No. FD/MAP/08 sheet No. 1/1
Visitor Chair, PP Cushion Arm, Powder Coated Pipe Stand, Leatherette Tapestry as per Model No. GM-226 A of Geeken or equivalent of Godrej, Methodex as approved by the GE
Almirah Large Steel as per drawing No. FD/E6/MAP/18 sheet No. 1/1
Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/1
Rack steel (915 mm X 760 mm X 1905 mm) as per drawing No. FD-129(M) sheet No. 1/1
Dining table for OR's as per drawing No. FD-165(M) sheet No. 1/1
Form with back (1800 mm long) as per drawing No. FD-78(M) sheet No. 1/1
Locker (steel) as per drawing No. FD-1029 sheet Nos 1/2 & 2/2
Chair Draughtsman as per drawing No. FD-204 sheet Nos 1/1
Table draughtsman as per drawing No. FD-303 sheet No. 1/1
Chair easy as per drawing No. FD-358 sheet No. 1/1
Sofa set 5 seaters (3 + 1 + 1) as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2
Charpoy folding IP with hard top as per drawing No. FD-388(R) sheet No 1/1
Rack pigeon holes (steel) as per drawing No. FD-1037 sheet No. 1/1
Black board with easel and pointer (steel) as per drawing No. FD-1041 sheet No. 1/1
HANDMADE WOOL CARPET (2.5 metre X 1.8 metre), made of Mill-spun Cotton, as per IS 5641: 1993, pile height 5 mm, Pile Density of 95 g/m²/mm, Moth Resistance, wool content of 95 percent
Desk Stand Lecture (steel) as per drawing No. FD-1022 sheet No. 1/1
Table conference as per drawing No. FD-287 sheet Nos 1/2 & 2/2
Table dining 4 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1
Dressing table (ladies) as per drawing No. FD-378 sheet No. 1/1
Stool dressing as per drawing No. FD/E6/MAP/14 sheet No 1/1
Teapoy (600 mm X 450 mm X 540 mm) as per drawing No. FD-382 sheet No. 1/1
Work bench workshop (1800 mm X 900 mm X 760 mm) as per drawing No. FD-301 sheet No. 1/1
Receptacle as per drawing No. FD/E6/MAP/13 sheet No. 1/1
Table dining for six persons (1500 mm X 900 mm X 760 mm) as per drawing No. FD-273 sheet Nos 1/2 & 2/2
Bath Mat (PVC) as per drawing No. FD/E6/MAP/07 sheet No. 1/1
Chair easy per drawing No. FD-229 sheet No. 1/1
Chair writing as per drawing No. FD-280 sheet No. 1/1
Table with drawer (900 mm X 600 mm X 760 mm) as per drawing No. FD-283 sheet No. 1/1
Chair dining as per drawing No. FD-1105 sheet No. 1/1
Table for Havs & Ors (steel) as drawing No. FD-1007 sheet No. 1/1
Table without drawer (900 mm X 600 mm X 760 mm) as per drawing No. FD-284 sheet No. 1/1
Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1
Schedule 'A' Part-XIV(ARBORICULTURE)
TREE GUARDS :Supplying & fixing of tree guards 60 CM in plan and 1.5 meters high from ground level made of 30 mm X 30 mm X 3 mm angel iron frame and 30 mm X 3 mm flat iron welded wire mesh of size 32 mm X 32 mm X 3 mm and vertical angle with shoe shall be embedded in the round firmly tree guard as shown in drawing (Drawing No : CWE/SGNR/SD/158/15 Sheet-1/1 revised dated 13 Sep 2019) with number plate and writing name of tree complete all as specified and directed Note: Tree guard shall be painted two coat of synthetic enamel paint over of red oxide primer complete in all respect.
Supply and stacking of well decomposed Cow dung/ meegni manure including royalty, loading, unloading, transportation and stacking etc. at site. Note:- For the purpose of payment the stack measurement shall be reduced by 10% for voids.( 338 Cum for Lawns and 49 Cum for trees and shrubs)
Supply only liquid form chlorophyriphos 20 % EC conforming to IS: 8944 complete all as specified and directed.
Schedule 'A' Part-XV(MISCELLANEOUS PARTS)
Taking down old unserviceable submain wiring (concealed or surface) 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number excluding batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.
Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down old unserviceable earthing any type and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed.
S & F central hole basin mixer with regular spout with popup waste system with braided boses as per catalogue No. SKU: QQT-CHR-7169B of Jaquar or equivalent of Make as mentioned under Appendix “B” of Particular Specifications complete all as specified and as directed.
S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F vertical distribution board, triple pole and neutral with four pole MCCB 160 A 16 KA as incomer, double door, 4 way, degree of protection: IP54, fabricated of CRCA steel sheet including copper busbar of suitable rating, standard DIN rail, top and bottom removable type gland plates with knock outs, locking arrangement, powder coated and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F modular blanking plate 1 module complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.
S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.
Supply, fixing and testing LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F evaporative air coolers (desert coolers) as per IS 3315: 2019, minimum air capacities 5000 cum per hour, sump tank capacity 100 litres, cooling efficiency not less than 65%, maximum power consumption 350 watts, plastic body, noise level not more than 65 dBA at 1 m distance including connecting up with three core flexible copper conductor cable of suitable size including numbering of coolers using two coats of synthetic enamel paint complete all as specified and as directed.
Taking down and refixing the existing serviceable desert cooler of any capacity complete all as specified and as directed
Taking down and refixing the existing serviceable water cooler of any capacity complete all as specified and as directed
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.
Supplying, installing, testing and commissioning air cooled split unit air conditioner with indoor unit (IDU), outdoor unit (ODU) of capacity 1.50 TR, single phase, input voltage 170 to 270 V AC, 50 Hz, surface / concealed copper Refrigerant piping with insulation (EP Foam pipe section) up to 5 metre (IDU to ODU), copper power cable up to 4 metre, PVC Insulation, FR-LSH copper wire, complete with inverter, twin rotary compressor, cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with BEE 5 star rating complete all as specified and as directed.
S & F in integrated type Heat Pump water heater with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 3 HP, hermetically sealed with environment friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 12 kW and rated power input of not more than 2.5 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre. NOTE: (a) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (b) Heat pump should have a user friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump.
Material and labour for construction and laying of kerb of size as directed directly on the road construction site with automatic kerb casting machine (kerb/divider making/laying machine), using M25 (Design Mix) grade cement concrete laid in position to the required line, level and curvature kerb stone cast continuous and making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) at a distance as directed, including making drainage opening wherever required, including necessary excavation/earth work and making good disturbed surface complete all as specified and as directed.
M & L for construction of new valve pit/chamber of size 450 mm (Length) X 450 mm (Breadth) X 450 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 6.35 kV/ 11 kV, upto any size of nominal cross sectional area of main conductor, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit complete all as specified and as directed.
Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high 'J' type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge.
S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
M & L for cable route indicator made out of CI plate 100 dia, 8 mm thick, embossed with lettering "MES LT Cable", welded or bolted onto 35 mm X 35 mm X 6 mm angle iron, 500 mm long duly painted with anti-corrosive paint in brown colour & including necessary earthwork and excavation, embedded in PCC M15(Nominal Mix) using 20 nominal size graded crushed stone aggregate of size 400 mm X 400 mm X 300 mm complete all as specified and as directed.
Supplying, installing, testing and commissioning outdoor type compact substation (CSS), factory assembled (non walk type) having 11 kV, 630 Amps, internal arc fault for 20KA for 1 sec as per IEC 61330/62271-200 and comprising as under: - (A) MV COMPARTMENT: 11 KV, 630A, 25KA/3 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271 - 202.IAC category IAC-AFL. The Switchgear includes the following HV cubicles The indoor non -extensible SF6 insulated RMU fully motorised consist of 1No. Vaccum Circuit Breaker with Riser (ICOG type) with self-powered relay for protection of transformer (a) Rated voltage should be - 12 kV (b) Rated power frequenecy voltage - 28 kV (c) Rated lightening withstand voltage - 75 kV (d) Rated current for Ring main feeder - 630 amps (e) Rated current for LBS feeder - 630 amps (f) Rated short time current - 25 kA / 3 sec (g) Rated short time making current -50 kA (h) Ambient temperature (0 deg C to + 50 deg C) (i) Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFLR (j) RMU shall be provided with protection CTs rated for 30 / 1amps, class - 10P10 accuracy , 2.5 VA burdan for circuit breaker (k) The feeder shall be self-powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol. (l) Dead short Circuit life of VI - 40 No
Srl Item No 15.039 Continued...... (B) TRANSFORMER COMPARTMENT: mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 400 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. (C) LV COMPARTMENT: The LV compartment with Degree of protection-IP54 designed for a 50-degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment : - (a) 1000 Amps, 50kA withstand fault level capacity rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection (b) Air Circuit Breaker (ACB) of rated current 630 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection (Incomer) (c) Outgoing - 250A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics=25kA - 1 No 200A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics-=25kA - 2 Nos 160A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics=25kA - 1 No All MCCB (incomer & outgoing) should be BIS certified.
Srl Item No 15.039 Continued...... (d) APFC Panel: Designing, manufacturing, supplying, fixing, erecting, testing and commissioning LT APFC panel with capacitor bank, conforming to IS 16636: 2017, 100 kVAR, outdoor installations, rated system voltage of the panel 440 V ± 10%, rated frequency 50 Hz, 3 phase, 4 wire, delta connected, rated impulse withstand voltage 8 kV, free standing, pedestal mounted, made of cold rolled close annealed sheet of minimum 2 mm thick for the load bearing structure and minimum 1.6 mm thick for door and partition, 50⁰C ambient temperature, IP 54 Ingress Protection, 500 Amp rated copper busbar, metallized polypropylene (MPP) dielectric type, resin filled box type, self-healing type, shunt capacitor as per IS 13340: 2012, switching configuration: 50 kVAR X 1 No + 25 kVAR X 1 No + 10 kVAR X 2 Nos + 5 kVAR X 1 No (total five steps), suitable protection in line with IEC and IS for overheating, over current, earth fault, over voltage, short circuit, thermal overload and over pressure, suitable size power and control cable as per Indian Standards, powder coated in grey colour, including microprocessor based automatic power factor correction controller with human machine interface, cooling fans, capacitor duty contactors, 7% detuned reactors, two earth terminals in the panel and as per the details mentioned below complete all as specified and as directed. and shall be including the followings: - (I) INCOMING: (i) MCCB rated current(In): 250A, ultimate short circuit breaking capacity (Icu): 50 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply – 1 No (ii) Microprocessor based automatic power factor correction controller (minimum 5 steps)- 1 No (iii) Cooling Fans to be provided for forced cooling (II) OUTGOING: (a) (i) 5 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No
Srl Item No 15.039 Continued...... (ii) MCCB rated current(In): 15A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 5 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 5 kVAR 7% detuned reactor copper wound – 1 No (b) (i) 10 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 20 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 10 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 10 kVAR 7% detuned reactor copper wound – 2 Nos (c) (i) 25 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 50 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 25 kVAR capacitor duty contactors – 1 No
Srl Item No 15.039 Continued...... (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 25 kVAR 7% detuned reactor copper wound – 1 No (d) (i) 50 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 100 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 50 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 No (vi) 50 kVAR 7% detuned reactor copper wound – 1 No Note: (a) The kVAR rating of capacitor mentioned is for rated voltage of 440 V. However, the capacitor shall be provided for rated voltage of 480 V by enhancing the kVAR rating suitably.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 250 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (b) MCCB rated current (In): 63 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (E) Accessories:
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 160 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 160 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 63 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 Nos (b) MCCB rated current (In): 32 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (c) MCB, SP, 10 kA, C-type, rated current 6 to 32 A: -4 Nos (d) MCB, TPN, 10 kA, C-type, rated current 16 A: -4 No
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 100 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 100 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 63 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 40 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 Nos (b) MCCB rated current (In): 20 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 Nos (c) MCB, SP, 10 kA, C-type, rated current 6 to 32 A: -3 Nos (d) MCB, TPN, 10 kA, C-type, rated current 10 A: -2 No
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 160 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 160 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 16 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (c) MCB, SP, 10 kA, C-type, rated current 6 to 32 A: -4 Nos (d) MCB, TPN, 10 kA, C-type, rated current 10 A: -4 No (E) Accessories:
Construction of platform for transformer having dimension (2500 mm X 2500 mm), height 1200 mm and foundation depth of 1200 mm including necessary earthworks in any type of soil, 150 mm moorum filling in foundation, 150 mm PCC foundation with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick externally in two coats of (15 mm and 5 mm) in cement mortar 1:4, enclosed spaces filled with moorum, 75 mm PCC subbase of flooring with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, 150 mm PCC flooring with M10(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash complete all as specified and as directed.
Disconnecting all existing connection with transformer and taking down and shifting transformer from any substation under the GE to new location and including installation at new location including connecting all connections, earthings, conductors, cables, nuts, bolts, washers etc. complete all as specified and as directed.
Supply & fixing 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with10 sqmm copper wiring, IP54 protection grade complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor upto 120 sqmm, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed.
Disconnecting all existing connection from LT Panel/ Feeder Pillar Box and taking down and shifting LT Panel/ Feeder Pillar Box from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation at new location including connecting all connections, earthings, conductors, cables, nuts, bolts, washers etc. complete all as specified and directed.
Material and labour for laying of double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 90 mm, minimum inside dia 67 mm conforming to IS 16205 (Part 24) : 2017 including boring of holes by trenchless technology using ultra sounding technique and necessary machine including all fittings complete all as specified and as directed.
Material and labour for laying of double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 140 mm, minimum inside dia 106 mm conforming to IS 16205 (Part 24) : 2017 including boring of holes by trenchless technology using ultra sounding technique and necessary machine including all fittings complete all as specified and as directed.
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 170, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 300, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (grade X 02Cr19Ni1O, 304 S2, surface finish No. 4 as per IS 6911: 2017) gate made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
M & L for construction of new valve pit/chamber of size 1050 mm (Length) X 1050 mm (Breadth) X 1050 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.
M & L for cutting galvanised mild steel pipe of nominal bore 100 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed.
Supply, installation, testing & Commissioning of Mechanical type incinerator electrically operated, made of galvanised iron of capacity 50 Kg/hour suitable for burning including shredder complete all as specified and as directed.
Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 25000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately.
Supply, assembly and erection of stainless steel (SS-304 grade) of 0.8mm thick rectangular duct (for industrial cooler) jointed by TIG/MIG welding or riveted with SS flanges with neoprene gasket at joint, supports of MS angle iron or SS rods complete all as specified and as directed. Note: The design of the duct for industrial cooler shall be submitted by the contractor for the approval of the GE.
S & F stainless steel (SS-304 grade) air grills for air swing and wider coverage complete all as specified and as directed.
S & F telephone socket outlet including metal box complete all as specified and as directed.
S & F 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed.
S & F television antenna socket outlet including metal box complete all as specified and as directed.
S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed.
S & F 18 W surface mounted LED down lighter with thermally managed aluminum pressure die-cast housing with heat dissipating fins with flicker controlled technology complete all as specified and as directed.
S & F stainless steel braided flexible connection pipe for hot and cold water supply for geyser, 15 mm bore, 450 mm length, 12 bar working pressure complete all as specified and as directed.
M & L for laying of factory made precast manhole as per IS 17725: 2022 using M35(Design Mix) Grade of concrete and Fe 500 Grade of reinforcement (TMT Bars) consisting of base unit, base riser, base slab, cone section, riser unit, transition slab, adjusting unit, lifting arrangement, footstep, rocker pipe, assembled and connected with joints as mentioned in IS 17725: 2022 to achieve watertight structures complete all as specified and as directed. Note: - The cubic content of precast concrete shall be measured for payment purpose.
S & F factory made precast cover slab including frame made of steel fibre reinforced concrete (SFRC), medium duty, 100 kN breaking load in any shape and size (square/ rectangular/circular), 75 mm thickness, minimum M30 grade of concrete, conforming to IS 12592: 2002 complete all as specified and as directed.
M & L for 18 mm thick telephonic black granite on vertical surfaces of columns, pillers, etc. fixed with 15 mm thick cement mortar (1:3) or type 3 adhesive as per IS 15477: 2019 using a bed of an adhesive not less than average 6 mm and not exceeding average 12 mm in final bed thickness complete all as specified and as directed.
M/s Khanna Enterprises (BID ID -3415042)
SOM BUILDERS (BID ID -3416578)
SHREE GURU NANAK CONSTRUCTION COMPANY (BID ID -3415774)
RAJENDER ENTERPRISES (BID ID -3415888)
Brahma Infra (BID ID -3416283)
M/s. Shiva Engineers (BID ID -3415420)
ENGINEER CONSTRUCTION PVT. LTD. (BID ID -3415174)
Jasraj & Company (BID ID -3415678)
M/S Shiv Shakti Enterprises (BID ID -3415754)
M/s Azure Infrastructure Construction Co. (BID ID -3416213)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid