| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.7 L+₹1.0 L (4.33%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹25.3 L+₹1.6 L (6.77%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹26.1 L+₹2.5 L (10.4%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹26.3 L+₹2.6 L (10.8%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹24.7 L
EMD Value
₹49,500
Closing Date
28 May 2022, 6:00 pmClosed
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
SPECIAL REPAIRS TO TOILET BLOCKS BLDG NO TB147 TB 148 TB 149 TB 150 OF TRAINEES IN AB COY OF 1 TRG BN 1 EME CENTRE SECUNDERABAD UNDER GE N SECUNDERABAD
2022_MES_520991_1
8577
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹49,500
Yes
25 Jun 2022
29 Apr 2022
30 May 2022
29 Apr 2022
28 May 2022
14 May 2022
Amount
Demolition of concrete in ground floors (un re-inforced) and paving not exceeding 15 cm thickness (below or above ground level) and including removal of rubbish/ demolished materials outside of MoD land complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry /block masonry, built in cement mortar including facing, dressed stone work and precast concrete all quoins, arches, pillars, coping etc., but excluding ashlars articles complete all as specified and as directed.
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
M & L for rendering 15mm thick in CM 1:6 on other than fair face of brick work surfaces to be finished fair and even smooth with using extra cement complete all as specified and as directed.
M & L for PCC 1:4:8 type D2 75mm thick using 40 mm graded stone aggregate as sub base to floor all as complete all as specified and as directed.
Taking down cement plaster including terrazzo finish/ wall tiles on brick or stone walls etc of any description, including raking out joints hacking for key scrubbing down with water etc., complete all as specified and as directed.
Dismantling wall, floor or hearth tiling including cement mortar bedding but not backing and rubbish off the premises complete all as specified and as directed.
M & L for non skid joint free coloured glazed tiles (300x300mm) x 7mm thick, in floor etc., set and jointed in neat cement slurry and pointed in white cement with pigments over screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles 200mm x 300mm x 7mm thick, on vertical surfaces such as skirting /dados etc set and jointed in neat cement slurry/ paste and pointed in white cement with pigments over base coat of 10mm thick in CM 1:4 complete all as specified and as directed.
S & F Vitreous china Squatting pan, Orissa pattern, size 580 x 440mm white, with integral foot rest including 'P' or 'S' trap with provision of cement concrete bedding complete, fixed in repairs all as specified and as directed.
S&F in repairs vitreous china wash down water closet (pedestal pattern) white, complete including PVC seat cover (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.
M&L PVC valve less, syphonic action type, 10 ltrs capacity flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32mm dia and fixed in repairs complete all as specified and as directed.
S&F Stop valves / angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, of size 15mm bore (minimum weight 90 grams) complete all as specified and as directed.
Taking up or down steel tubing 15mm dia and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing 20mm dia and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing 40mm dia and connections including cleaning for refixing complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow, Tee, bends, unions, sockets, threaded adaptor and end pieces etc., to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc., complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow, Tee, bends, unions, sockets, Threaded Adaptor and end pieces etc., to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 40 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow, Tee, bends, unions, sockets, threaded adaptor and end pieces etc., to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
M&L for fair cutting grooves n exc 10 cm width or girth on exposed surfaces of brick work such as in splays, chamfers, etc.including rubbed finish and waste and making good the cutting surface in CM 1:3 after fixing pipes/conduits etc., complete all as specified and as directed.
S & F GI tubing of size 40mm dia, medium grade, laid in floors/walls complete all as specified and as directed.
S & F in repairs bib tap cast copper alloy fancy type chromium plated screwed down for iron pipes or brass ferrule of size 15 mm bore (minimum weight 90 grams) complete all as specified and as directed.
S&F for gate valve 20 mm bore, gun metal gate valves with iron wheel head screwed both ends for iron pipes complete all as specified and as directed.
S&F for gate valve 40 mm bore, gun metal gate valves with iron wheel head screwed both ends for iron pipes complete all as specified and as directed.
M&L for PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and as directed.
M & L for rendering 15mm thick on brick work in CM (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M & L applying three coats of white wash on walls, including preparation of newly plastered surfaces complete all as specified and as directed.
M & L as in repairs for UPVC/PVC (SWR) pipes 110mm dia fixed to walls single socketed with rubber ring joints including dismantling of old pipes complete all as specified and as directed.
M & L as in repairs for UPVC/PVC (SWR) pipes 110mm dia laid in floors single socketed with rubber ring joints including dismantling of old pipes complete all as specified and as directed.
M & L for UPVC/PVC (SWR) pipes 75mm dia laid in floors, single socketed with rubber ring joints complete all as specified and as directed.
Supply & fixing PVC (SWR) bends 110mm bore, any radius with oval access door fixed in repairs complete all as specified and as directed.
Supply & fixing 110 mm bore PVC (SWR) double 'T' equal or un equal bends with access door complete all as specified and as directed.
Supply & fixing PVC (SWR) bends 110mm bore, any radius fixed in repairs complete all as specified and as directed.
Supply & fixing PVC (SWR) bends 75mm bore, any radius with oval access door complete all as specified and as directed.
Supply & fixing PVC (SWR) 110mm bore junction Double 'Y" equal or unequal with access door complete all as specified and as directed.
M & L for PVC(SWR) 110 mm dia vent cowl fixed to walls complete all as specified and as directed.
S & F PVC (SWR) 125/110 dia gully trap setting and jointing with solvent cement as fixed in repair complete all as specified and as directed.
S & F in repairs of 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
M & L for rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) hoisted and fixed in position of 2000 litre capacity including supply and fixing 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe 20mm bore & fixed (Minimum weight 210gms), fixed in repairs complete all as specified and as directed.
Taking down chowkats or frames with shutters very carefully (without taking off shutters from frames) not exc 1.5 Sqm each and refixing same in same opening including replacement of aluminium 100mm size hinges-3nos, aluminium 150mm handles -2 Nos & aluminium 150mm long tower bolts -2nos in each door complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) not exceeding 1.5 Sqm each complete all as specified and as directed.
S & F Solid PVC door framed of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube all as specified in SSR Part-II of 2020.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings given in Section 8 of MES Schedule Part-II 2020 as applicable complete all as specified and as directed.
S & F 150mm long aluminium handles, cast type anodised extruded section and fixed complete all as specified and as directed.
S & F aluminium anodized barrel tower bolt of extruded section of size 150 mm long complete all as specified and as directed.
M & L for Butt hinges of size 100 mm long extruded aluminium alloy with galvanised mild steel hinge pin of type C-21 complete all as specified and as directed.
M&L for preparing the plastered or unplastered old surfaces of walls and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old painted steel surfaces and applying two coats of synthetic enamel painting to steel surfaces complete all as specified and as directed.
M&L for 6mm thick asbestos cement, corrugated or semi corrugated sheets in roofs fixed with L-type or J-type or cranked hook bolts including dismantling of old one complete all as specified and as directed.
M&L for 6mm thick asbestos cement serrated ridge for corrugated or semi corrugated sheets including dismantling of old one complete all as specified and as directed.
Complete removal of existing treatment on wall surfaces and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frame work, stone, concrete or brick surrounds, glazed with putty or fixed with beadings complete all as specified and as directed.
M&L for 4 mm thick figured glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M&L for designer rubber moulded chequerred cement concrete tiles with mixture of grey and white cement in equal proportions with pigments of size 300 x 300 x 22mm or 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layer in CM 1:6, 15mm thick for laying floor finishes etc., complete all as specified and as directed.
Material and labour for 75 mm thick plain cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) in plinth protection / paths laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at the junction of wall and plinth protection , at 3 metre interval and every change of direction duly filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth to be sealed with ceiling compound grade ‘A’ complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for laying of drain pipes etc., or for manhole, etc., not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning filling in soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed complete all as specified and as directed.
M&L for cement concrete type D-2 1:4:8 using 40 mm graded stone aggregate in filling foundation, sub base of floor and mass concrete complete all as specified and directed.
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 15mm thick in CM 1:4 on other than fair face of brick work surfaces to be finished fair and even smooth with using extra cement and mix with 2% water proofing compound by weight of cement complete all as specified and as directed. Note: Water Proofing Compound shall be measured and paid separately.
Extra over forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and as directed.
M & L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab for manholes set in cement mortar 1:6 complete all as specified and as directed.
S&F TMT bars 8mm to 10mm dia cut to length, bent to shape required including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for reinforced concrete pipes class NP-2 ,150 mm dia laid and jointed complete with collars and including demolition and breaking up existing SGSW/RCC pipes concrete bed including packing under and haunching jointed in cement mortar and taking out of trenches if required etc., complete all as specified and directed.
M&L for concrete bed with cement concrete 1:4:8 type D2 using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 150 mm bore complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry / Block masonry, built in cement mortar including facing, dressed stone work and precast concrete all quoins, arches, pillars, coping etc but excluding ashlars articles complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided reinforced (reinforcement of cut as required to facilasite demolition etc) and removal of rubbish/ demolished materials outside of MoD land complete all as specified and as directed.
Cutting into existing manholes for connecting new drain, making good to pipe and rendering, cutting out existing benching for end forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed.
Material and Labour for cleaning the blocked manholes / septic tanks completely by emptying the liquid, semi solid and solid content including cleaning the inlet, outlet and getting out by using suction pump and filling the foul material in to the covered tanks attached to suction pump and removing, transporting and disposal of the same at a place earmarked for disposal of the foul material by municipal authorities to outside the cantonment area complete all as specified and as directed. NOTE: Cubic content of filled up portion of septic tank shall be measured for payment purpose.
Taking down the existing unserviceable point wiring of any description, type, size of light or fan or power or two way or bell etc on TW batten or conduit including removal of batten or conduit or gutters or wooden boards or switches or sockets or regulators or light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall or ceiling to match with the existing surfaces complete all as specified and as directed.
Material and labour for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories duly ISI marked on concealed etc., with new sunk type pressed steel terminal boxes suitable for switches duly painted with two coats of red oxide zinc chrome primer with suitable hylam sheet cover of suitable size for mounting of switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following :- (a) One light / bell point controlled by one, one way switch 5 amps, single pole.
All as per item No. 74 but one ceiling fan/exhaust fan point controlled by one, one way switch 5 amps, single pole and regulator complete all as specified and as directed.
All as per item No. 74 here in before but using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade FRLS conforming to IS-694 for 3 pin 15 amps switch socket combination point on independent board and running of 2.5 Sqmm copper conductor PVC insulated cable FRLS as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
Supply and fix switch piano, single pole one way, flush type, 5 Amps 230 volts for light, fan and tube light complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, multipurpose 6 pin of 15 amps, flush type complete all as specified and as directed.
Supply and fix Lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and as directed.
Supply and fix Ceiling rose of surface Bakelite 65 X 50 mm, three terminals, AC 50 HZ, 230 Volts complete all as specified and as directed.
Supply and fix wall mounted indus plus LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with necessary mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W including taking down existing unserviceable tube light fitting complete all as specified and as directed. Make: Havells cat No-REGALBATTENT8UPTO 1X22WSSBSWH incl Tube Rod cat No-PHOTONULTRA2.01213T8SSTL20WLED 865SPC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE & Philips Cat No. TMC501P1XT-LED22WP3241 incl LED tube 20W.
Supply and fix in replacement LED security light luminaire fitting of 1x35 watts with deep drawn housing including all accessories suitable 40 mm dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as specified and as directed.
Supply and fix sheet metal enclosure MCB DB SPN 8 Way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed.
Supply and fix MCB SPN 40 amps 240 volts 'C' curve suitable for fixing in MCB DB including taking down existing old unserviceable MCB complete all as specified and as directed.
Supply and fix MCB SP 6 to 32 amps 240 volts 'C' curve suitable for fixing in MCB DB including taking down existing old unserviceable MCB complete all as specified and as directed.
Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded stone aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
Supply laying or fixing or passing through pipe, 1100volts grade heavy duty cable with PVC insulated aluminium stranded served with inner sheathing of PVC tape and overall PVC insulated in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire of size 10 sqmm two single core cable complete all as specified and as directed.
Supply and fix Heavy duty Exhaust fan, metal body, 300mm sweep, 1400 RPM, 230 volts AC Supply with louvers including opening in wall and fixing arrangement with nut bolts and making good the disturbed surface complete all as specified and as directed. Make: BAJAJ Model FRESHEE MK-II/Havells Model VENTIL AIR - DB NEO or equivalent in Khaitan as approved by GE.
AMK Builders
Himagiri Constructions
K LAKSHMAN SINGH AND CO
M/s Bhavani Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .