Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹28.0 LAccepted-AOC 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹30.5 L+₹2.1 L (7.34%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | L-3₹32.2 L+₹3.8 L (13.5%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest. | |
| 4 | L-4₹35.1 L+₹6.7 L (23.6%)Rejected-Finance VILLAGE DEVRATHA NO 1 POST SHAHGANJ DIST AGRA U P | L-4 | Rejected-Finance Being other than lowest. | |
| 5 | L-5₹37.8 L+₹9.4 L (33.1%)Rejected-Finance H O 325 JAIPUR HOUSE AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L-5 | Rejected-Finance Being other than lowest. |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Nov 2020, 6:00 pmClosed
GEAFADMAREAAGRA
GEAFADMAREAAGRA
REPAIR TO ROOF TREATMENT AND ALLIED WORKS IN MD ACCNS UNDER AGE B R I OF GE AF ADM AREA AGRA
2020_MES_386304_1
8000-1835/E8
Open Tender
Civil Works
Item Rate
180 days
GEAFADMAREAAGRA
Class D Cat a ( i ) and for un enlisted firms docs as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹80,000
Yes
26 Dec 2020
14 Oct 2020
6 Nov 2020
14 Oct 2020
4 Nov 2020
21 Oct 2020
Amount
Taking down existing roof treatment of any description including mud phuska, brick tiles/ PCC tiles, plastering, leaping plaster of any thickness cuting & up rooting tree roots/ vegitable growth & removing the debris from the premises upto 500 m from the MOD land including cleaning/ washing down and keeping surfaces clean complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roof slab or terrace, cleaning out, wetting, grouting, with cement sand slurry in 1:3 with mixing of WPC @ 2% by wt of cement complete all as specified and directed. Note :- WPC shall be measured and paid seprately.
M&L for PCC ( 1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in roof padding of any thickness on RCC roof slab or terrace with using WPC as per manufacturers instructions including finishing the surface even and smooth with using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid seprately.
M&L for rendering or screed bed 10 mm thick in CM 1:4 on RCC roof slab/ terrace surfaces with mixing WPC as per manufacturers instructions including finishing the surface even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid seprately.
Supply only liquid water proofing compound conforming to IS complete all as specified and directed.
M&L for water proofing treatment to roof with APP based polymeric membrane, 3 mm thick (min.) consisting of 90 to 100 micron thick central core of HMHDP film and standard weight of 3.00 kg/sqm reinforced with polyster non woven fabric ( weighing n. less than 160 gm / sqm ) manufactured by IWL India Ltd/ STP/ TIKI TAR DANOSA shall be applied over and including applying a coat of hot blown bitumen 85/25 conforming to IS-702 @ 1.20 Kg/Sqm over a coat of bituminous primer @ 0.30 ltrs/Sqm surface, application of APP modified membrane and joint shall be by torch application. The overlaps shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction complete all as specified & directed. Note : Treatment shall be done through authorised representative of manufacturer.
M&L for applying two coats of aluminium paint on membrane surfaces including prepration of surfaces complete all as specified and directed.
M&L for 20 mm thick PCC tiles machine pressed factory made of size 200 mm x 200 mm as per IS-1237-1980, laid over and including 15 mm thick screed bed in cement mortar 1:4 mixed with polymer based liquid water proofing compound as per manufacturer's instructions and joints of tiles shall be filled with CM 1:3 mixed with crude oil complete all as specified and directed. Note :- WPC shall be measured and paid seprately.
M&L for 20 mm thick locally availavle brick tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 mixed with polymer based liquid water proofing compound as per manufacturer's instructions and joints of tiles shall be filled with CM 1:3 mixed with crude oil complete all as specified and directed. Note :- WPC shall be measured and paid seprately.
Laying only brick/ PCC tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 mixed with polymer based liquid water proofing compound as per manufacturer's instructions and joints of tiles shall be filled with CM 1:3 mixed with crude oil complete all as specified and directed. Note :-Brick/ PCC tiles as retrived under item No 1.00 here-in-before shall be reused.
Disconnecting existing PVC water tanks (exc 500 &1000 litres in capacity), setting aside (or lowering if required) including, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning, etc complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
M&L for brick work with sub-class `B' old size bricks, as in full brick thick walls straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone or concrete surfaces of wall etc, icluding raking out joints , hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work/ concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant cement primar of walls complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls including taking down of old pipe from wall complete all as specified and directed.
Taking up or down steel/ PVC water tubing 20 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Re-fixing old steel water tubing/ PVC pipe of 20 mm bore and connection in new or old positionwith new fittings, fixed to the walls, ceiling or laid in floor complete all as specified and directed.
S&F 20 mm bore steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors complete all as specified and directed.
M/s K S Builders
Asha Construction
M/s M S Sharma and Co.
Rakesh kumar
Sethi Brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .