| 1 | Qualified Make: NA
Model: Neumann & Miller and NM-4406 5A 18 ROOM NO A GROUND FLOOR FRONT SIDE TILAK NAGAR DELHI DELHI 110018 UDYAM DL 11 0012098 07AAKFG1385Q1ZR B R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110018 | Make: NA
Model: Neumann & Miller and NM-4406 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 May 2018, 12:00 pmClosed
SPECTROPHOTOMETER Experience with Gov. Required 3 Year (s) SPECTROPHOTOMETER ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE Type of Spectrophotometer UV - VISIBLE N/A Type of Optical System Double Beam N/A Monochromator Type Czerny-turner N/A Detector Type Photodiode N/A Spectral Bandwidth Type Variable Bandwidth N/A LIGHT SOURCE Light Source Deuterium Lamp
Tungsten Halogen Lamp N/A Diffraction Grating (lines/mm) 1200 N/A Switching of Light Source Automatic N/A Wavelength Setting And Scanning Automatic N/A OPTICAL PERFORMANCE Source Wavelength - Minimum 190 N/A Source Wavelength - Maximum 1100 N/A Resolution 0.3 N/A 1/5 Wavelength Accuracy (+/-) 0.3 N/A Bandwidth (nm) 0.5
1
2.0
4.0
5.0 N/A If variable band width
Specify the incremental step value(mm) 0.1 N/A Scanning Speed (nm/min) 3600 N/A Focal length (mm) 0 to 49 N/A Photometric measurement modes Transmittance
Absorba nce
Concentration (Wavelength
time)
Energy N/A Photometric Absorbance (Max) (Abs) (+/-) 3 N/A Photometric Absorbance Accuracy (Max) (+/-) 0.002 N/A Photometric Transmittance (Max) (+/-) 100 N/A Photometric Transmittance Accuracy (Max) (+/-) 0.3 N/A Photometric Reflectance (Max) (+/-) 0 N/A Photometric Reflectance Accuracy (Max) (+/-) 0.3 N/A Stray Light Correction N/A N/A Baseline Correction Automatic N/A GENERIC Display In-built display N/A Display type LCD with Backlight N/A Display Size 3.2 N/A Test result printing Through external printer N/A If inbuilt printer
Type of printer N/A N/A Suitable software for connecting PC & Printer Yes N/A Connectivity USB
RS 232 N/A Internal storage(GB) 0.012 N/A Sample switching/selection Automatic N/A 2/5 Capacity of Sample holder/Sample Carousel 2 N/A Mximum Path Length of sample 100 N/A Number of Cuvettes supplied 10 N/A Power Supply 230 V ± 10
50 Hz N/A Spares and Consumables inclusive in the scope of supply true N/A List of Items and Quantity of each item included in the offer Comes with 2 Cell Holders N/A OPERATING CONDITIONS Minimum Operating Temperature 10 N/A Maximum Operating Temperature 40 N/A Operating Humidity (RH) (%) at 40 degree C 85 N/A WARRANTY Onsite Warranty 1 N/A Availability of Spares (at extra cost) 10 N/A Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement
control
and laboratory use General requirements Yes N/A Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement
control and laboratory use Yes N/A Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification Yes N/A If yes test report to furnished
to the buyer on demand Yes N/A Test Report number and date 18450 and 01-04-2018 N/A 3/5 Name and address of the Lab Star Labs and Delhi N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DINESH BAHADUR SINGH 752050
National Institute of Science Education and Research NISER Campus Post Office Jatani 1 15 EMD Required No ePBG Required No
28039
GEM/2018/B/3990
SPECTROPHOTOMETER
15 days
Odisha; Khordha
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| SPECTROPHOTOMETER Experience with Gov. Required 3 Year (s) SPECTROPHOTOMETER ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE Type of Spectrophotometer UV - VISIBLE N/A Type of Optical System Double Beam N/A Monochromator Type Czerny-turner N/A Detector Type Photodiode N/A Spectral Bandwidth Type Variable Bandwidth N/A LIGHT SOURCE Light Source Deuterium Lamp | - | - | - |
| Tungsten Halogen Lamp N/A Diffraction Grating (lines/mm) 1200 N/A Switching of Light Source Automatic N/A Wavelength Setting And Scanning Automatic N/A OPTICAL PERFORMANCE Source Wavelength - Minimum 190 N/A Source Wavelength - Maximum 1100 N/A Resolution 0.3 N/A 1/5 Wavelength Accuracy (+/-) 0.3 N/A Bandwidth (nm) 0.5 | - | - | - |
| 1 | - | - | - |
| 2.0 | - | - | - |
| 4.0 | - | - | - |
| 5.0 N/A If variable band width | - | - | - |
| Specify the incremental step value(mm) 0.1 N/A Scanning Speed (nm/min) 3600 N/A Focal length (mm) 0 to 49 N/A Photometric measurement modes Transmittance | - | - | - |
| Absorba nce | - | - | - |
| Concentration (Wavelength | - | - | - |
| time) | - | - | - |
| Energy N/A Photometric Absorbance (Max) (Abs) (+/-) 3 N/A Photometric Absorbance Accuracy (Max) (+/-) 0.002 N/A Photometric Transmittance (Max) (+/-) 100 N/A Photometric Transmittance Accuracy (Max) (+/-) 0.3 N/A Photometric Reflectance (Max) (+/-) 0 N/A Photometric Reflectance Accuracy (Max) (+/-) 0.3 N/A Stray Light Correction N/A N/A Baseline Correction Automatic N/A GENERIC Display In-built display N/A Display type LCD with Backlight N/A Display Size 3.2 N/A Test result printing Through external printer N/A If inbuilt printer | - | - | - |
| Type of printer N/A N/A Suitable software for connecting PC & Printer Yes N/A Connectivity USB | - | - | - |
| RS 232 N/A Internal storage(GB) 0.012 N/A Sample switching/selection Automatic N/A 2/5 Capacity of Sample holder/Sample Carousel 2 N/A Mximum Path Length of sample 100 N/A Number of Cuvettes supplied 10 N/A Power Supply 230 V ± 10 | - | - | - |
| 50 Hz N/A Spares and Consumables inclusive in the scope of supply true N/A List of Items and Quantity of each item included in the offer Comes with 2 Cell Holders N/A OPERATING CONDITIONS Minimum Operating Temperature 10 N/A Maximum Operating Temperature 40 N/A Operating Humidity (RH) (%) at 40 degree C 85 N/A WARRANTY Onsite Warranty 1 N/A Availability of Spares (at extra cost) 10 N/A Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement | - | - | - |
| control | - | - | - |
| and laboratory use General requirements Yes N/A Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement | - | - | - |
| control and laboratory use Yes N/A Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification Yes N/A If yes test report to furnished | - | - | - |
| to the buyer on demand Yes N/A Test Report number and date 18450 and 01-04-2018 N/A 3/5 Name and address of the Lab Star Labs and Delhi N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DINESH BAHADUR SINGH 752050 | - | - | - |
| National Institute of Science Education and Research NISER Campus Post Office Jatani 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
9 May 2018
24 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_28039.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .