Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.9 L+₹89,953.10 (11.2%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.3 L+₹1.3 L (16.1%)Rejected-Finance 122 SAMHARIYA ASOPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L3 | Rejected-Finance L3 | |
| 4 | L4₹10.8 L+₹2.7 L (33.8%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L4 | Rejected-Finance L4 |
Tender Value
₹8.4 L
EMD Value
₹16,880
Closing Date
16 Jul 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (P) Niwaru
AGE (I) (P) Niwaru
Provn of guard room and sentry post at main entry and exit gate at Niwaru Mil Stn
2020_MES_357694_1
AGE(I)(P)/N-05 2020-21
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (P) Niwaru
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) (P) Niwaru
₹16,880
Yes
7 Jan 2021
2 Jul 2020
17 Jul 2020
2 Jul 2020
16 Jul 2020
3 Jul 2020
60 days
Amount
Surface excavation n. exc 30cm deep and averaging 15 cm deep and getting out in soft/loose soil.
Excavation in trenches not exc 1.5m wide and not exc. 1.5m in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in soft/loose soil.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6
Returning, filing in, including spreading, levelling watering and well ramming in layers n.exc 25cm In hard/dense soil.
Earth filling under floors including spreading, levelling, watering and well ramming in layers not exc 25cm thick. Note:- Soil obtained from excavation under item 1 here-in-before shall be used for filling.
Removal of excavated soil to a distance exc. 50m but and depositing where directed.
M&L for 40-50mm thick kota stone for DPC.
M&L for formwork to sides and soffits of floor or roof beam, lintels including supports, overhangs etc also splays between floors and beams exc. Concrete.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete.
M&L for formwork to edges of concrete flats, roofs, floors etc not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for fair finished surfaces.
M&L for formwork to chajjas, troughs and similar item including edges.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 USING 20mm graded stone aggregate in vertical bans, pillars, piers and struts Note:- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20mm graded stone aggregate in chajjas and the like Note:- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20mm graded stone aggregate in slab supported on walls, beams and columns in floors, roofs, shelves and the like. Note:- Reinforcement & formwork shall be measured and paid for separately.
S&F deformed or twisted MS bar 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia as specified.
S&F deformed or twisted MS bar 10mm dia and above cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia as specified.
M&L for tratement of backfill in contactact with foundation at the rate of 7.5 liters of emulsion per square meter of vertical surface.
M&L for treating the top surface of filled earth at the rate of 5 liters of emulsion per square meter of surface.
M&L for 75mm thick PCC 1:4:8 type D-2 USING 40mm graded stone aggregate as in subbase to floor finished fair and even all as specified and directed by engineer-in-Charge.
S&F of steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, devetailed or welded.
S&F of framed work such as grills, gratings, etc with ends of bars shouldered and/or are riveted, forged into spikes, framed guard bars, railings and similar work conforming to Fe-290 Gde-E-165
S&F of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
S&F of sheet glass 4mm ordinary quality and glazing with oil puty in square n exc 0.5 sqm in each pane.
M&L rendering 10mm thick in CM (1:3) onceilings surface finished even and smooth without using extra cement complete all as specified.
M&L rendering 10mm thick in CM (1:6) on brick walls or concrete surface, surface finsished even and smooth without using extra cement complete all as specified .
M&L rendering 15mm thick in CM (1:4) on external brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified.
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:4 for laying floor finishes.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade including rubbing and polishing complete.
M&L for machine cut kota stone 20-25mm thick in riser of stepsand skirting over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade including rubbing and polishing complete.
S&F pressed steel frames 165mm x 60mm for doors with one or more rebates including necessary fiding lugs, hinges, lock strike plate etc complete as specified, supplied and fixed.
S&F flush door 40mm solid core construction with block board coreand poly wood face panels commerical type both sides.
S&F of MS hold fast confirming to Fe 290 Gde E-165.
M&L for hardcore of gauge n exc 63mm deposited spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface.
M&L for treating the under plinth at the rate of 5 liters of emulsion per square meter of surface
M&L for treating the soil alongwith external perimeter of building at the rate 2.2 liter of emulsion per meter of the perimeter wall
M&L for 50mm thick cement concrete type C-1, 1:3:6 in plinth protection.
S&F 100MM Butt hinges, medium weight, cold rolled mild steel, and fixed to angle iron chowkhat including welding complete.
S&F aluminium anodised barrel tower bolt 150mm long of extruded section and fixed.
S&F aluminium handle 150mm size cast type anodised ISI Marked
S&F aluminium anodised sliding door bolt 300mm with hasp, staple and fixing clips.
S&F aluminium anodised door stopper 150mm fixed in floor.
M&L rendering 20mm thick in CM (1:3) over concrete roof surface, surface finished even and smooth using water proofing compound complete all as specified.
Supply of integral water proofing compound only.
S&F of hat pegs, of brass solid body 175mm
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling and chajjas complete as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of primer on internal walls and as directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement paint of approved shade/tint over a coat of primer of external walls and as directed by Engineer-in-Charge.
M&L for preparation of new wooden surfaces and applying two coats of synthetic enamel paint over a coat of pink primer and as directed by Engineer-in-Charge.
M&L for preparation of new iron/steel surfaces and applying two coats of synthetic enamel paint over a coat of red and as directed by Engineer-in-Charge.
M&L for precasst cement concrete 1:2:4type B-1 using 20mm graded aggregates for blcok masonary with solid blocks exc 10cm in width and set in CM 1:6 all as specified.
M&L for sand filling under follors or in foundations including watering and consolidation.
M&L for machine pressed precast concrete interlocking paver block any shape and size confiming to IS 15658-2006 of 60mm thickness M-35 Grade with Grey Cement and pigment .
M&L rendering 15mm thick in CM (1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified.
M&L for 30mm (average thickness) PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in floors and surfaces finished fair & even.
S&F coloured Non Skid ceramic tiles 6 to 7 mm thick edge cut/joint free (square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 Sqm, floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match over 15mm thick screed in CM (1:4)
S&F of 35mm fly proof 1st class hard wood door shutter with sash bars edging of frame, champhered or round mitred and rebatedin any numbers.
M&L of angle iron door frame made out by 40x40x6mm thick including tie bar etc and welding complete etc.
Framed work such as grills, gratings, etc.. With ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barredd iron doors ladders; framed baluster; walk ways; railings; framework; of water tanks and similar work conforming to Fe 290 Gde e-165
Supply/fix/connect/passing through pipe/testing of PVC insulated armoured, heavy duty electric underground cable with aluminium conductor, 1100 volts gradek, across sectional area 25 Sq mm, 2 core passing through pipe or on pole or on wall or crossing the road.
Supply and fix DP/SPN MCB of 10 Amps, 50 Hz, 415 Volts, with rupturing capacity 10 KA in existing panel complete all as directed.
Supply, laying, jointing of 25 sqmm, 2 core, LT under ground cables 110Wolts grade, XLPE insulated and PVC shethed, heavy duty armoured, with multi standard aluminium conductors, IS-7098 marked laid in trenches/ducts/fixed on poles/valves/laid under roads/culverts, encased in GI Pipe complete all as specified and directed.
Sand cushioning for cables 8cm below the cable and 15 cm above the cable complete all as specified and directed.
Brick protection with sub class B old size brick well brunt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
S&F GI pipe light grade of size 50mm with all fittings and fixed to valve, sealings, laid in road/floor including making good all as directed by engineer-in-charge.
S&F MCB DP/SPN, of 10Amps, 50 Hz, 240Volts with repturing cap 10 KA in existing panel complete all as directed by Engineer-in-Charge
M&L for point wiring with 1100 volts grade PCV insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) dran into and including concealed rigid non metallic PCV conduit medium grade not less than 25mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanized pressed steel terminal boxes covered with 3mm thick hylam/phenolic laminate while sheet cover for mounting switches, sockets, fan regulators as required for the following:- (a) One light/fan controlled by one switch.
(b) One socket outlet 6 amp controlled by one switch on the same board with other switches.
S&F switch plano flush button type 230/250V grade on top covers single pole one way 6 Amp complete.
S&F socket outlet 2 in 1,2 & 3 Pin, 6 Amp, Flush type multipurpose use flush mounting type 230/250 Volts grade (ISI Marked) on top covers complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F electronic step type fan regulator 120-280 Volts of 100 watt capacity (Socket type) including connecting up complete.
Supply and fixing wall mounting box type LED light fittings 1 x 20 W, 1200MM Suitable for and alongwith single T8 1x20W, LED tube with extruded aluminium body, PC diffuser and inbuilt driver complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engineer-in-Charge.
S&F ceilling fan/wall mounted fan single phase AC 230 volts complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size.
S&F MCB DB SPN 4 way, double door suitable for 240 V complete all as directed including the MCB SPN 10 Amps, 10 KA- 01 Nos and MCB SPN 06 Amps, 10 KA - 02 Nos
S&F security LED light fittings 1x25 W alongwith wall mounting bracket, clamp, nut, bolts etc. Complete with all accessories incl connection with twin core twisted flexible copper conductor cable with suitable size all as directed.
Earthing complete with galvanised wteel earth plate electrodu 600mm x 600mm x thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washhers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specifed and indicated complete with funnel, charcoal, dust, salt etc and GI protection pipe, 40mm thick precast RCC M-15 (NOMINAL MIX) cover reinforced with XPM weight not less than 4 kg/Sqm witth suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected all as specified. Note :- Soil use for filling should be free from
S&F, laying GI pipe 25mm dia medium class laid in trenches including fittings all as specified and directed by Engineer-in-Charge
S&F gun metal glove or gate valve with iron wheel head, screwed both ends for 25mm dia pipe all as specified
Brick masonry valve pit of size 60x60x60cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement, earth worth in any type of soil incl removal to n. exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified.
M/s. Varinder Kumar Sharma
Shiv Construction Company
DIVYA ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .