Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹13.1 L+₹97,553.40 (8.05%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹13.3 L+₹1.2 L (9.72%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹14.2 L+₹2.1 L (17.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹22.4 L+₹10.3 L (84.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Jul 2023, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR MAINT OF STREET/ SECURITY LIGHTS, SOLAR STREET LIGHTS, GATE LIGHTS AND GARDEN LIGHTS AND ALLIED WORK AT AYODHYA CANTT UNDER AGE (I) AYODHYA.
2023_MES_607463_1
81757/AYD/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) Ayodhya
₹50,000
Yes
4 Sept 2023
30 Jun 2023
31 Jul 2023
1 Jul 2023
29 Jul 2023
15 Jul 2023
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured & Paid.
Supply & Laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engineer-in-Charge.
Supply & laying GI Pipe 25 mm dia steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as specified and specified
Supply & laying GI Pipe 40 mm dia steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as specified and specified
Supplying, laying, commissioning & testing 4 Sqmm 2 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing 6 Sqmm 2 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing 10 Sqmm 2 core LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of twin core flat or round sheathed stranded aluminium conductor cable of size 4 Sqmm complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No. 11.00 above, but of size 6 sqmm.
All as per Sl item No. 11.00 above, but of size 10 sqmm.
S&F junction box made of PVC 1.6mm thick of size 230mmx170mmx105mm including 2 Nos aluminium bus bar of 2mm thick duly fitted on the suitable insulator with fixing with 35x6 mm ms flate iron with nut bolt and washer and incl one MCB SP 6 amp with rail fitted in ms box inclulding suitable size cable hole,gland duly painted with one coat of aluminium paint over a coate of red oxide etc complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 m deep below normal ground level, connected with and including galvanised iron 4.00 mm dia connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350mm x 350mm x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in electric plate No. 3 of SSR Part-I and testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. Make:- Cromption/Havells/Philips/Surya.
All as per Sl Item No. 16.00 above, but of size 100 Watt.
All as per Sl Item No. 16.00 above, but of size 60 Watt.
All as per Sl Item No. 16.00 above but of size 45/50 Watt.
S&F LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. Make:- Cromption/Havells/ Philips/Surya.
S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. Make:- Cromption/Havells/ Philips/Surya.
S&F in repair LED outdoor drivers suitable for LED street light 45 to 60 Watt complete all as specified and directed by Engineer-in-Charge. Make:- Cromption/Havells/ Philips/Surya.
S&F in repair LED outdoor drivers suitable for LED street light/flood light 100 Watt complete all as specified and directed by Engineer-in-Charge. Make:- Cromption/Havells/ Philips/Surya.
S&F in replacement of Garden/ Gate light Decorative made up of high grade unbreakable polycarbonate material powder coated including one LED lamp 14W/20W B22 base and fixed with suitable dia & height light grade GI Pipe complete all as specified and directed by Engineer-in-Charge. Make- Havells Cat pat No :- CORALMINIPT15WLED757PSYMTOPC or equivalent to Bajaj/ Philips/ CG.
S&F in replacement of Garden/ Post light Decorative made up of high grade unbreakable polycarbonate material powder coated including one LED lamp 14W/20W B22 base and fixed with suitable dia & height light grade GI Pipe complete all as specified and directed by Engineer-in-Charge. Make :- Havells/ Bajaj/ Philips/ CG.
S&F in replacement of MCCB, 4 pole, 63 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and directed by Engineer-in-Charge. Make :- L&T / Havells / Schneider.
S&F in replacement of MCCB, 4 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and directed by Engineer-in-Charge. Make :- L&T / Havells / Schneider.
S&F in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and directed by Engineer-in-Charge. Make :- L&T /Havells / Schneider.
S&F MCB 230V,SPN 40 Amps, 'C' curve, 10 kA including taking out of old one complete all as specified and as directed. Make: - L&T/ Havells/Legrand
S&F MCB 230V, single pole, 6-32 Amps, 'C' curve, 10 kA including taking out of old one complete all as specified and as directed. Make:- L&T/ Havells/Legrand
S&F in replacement of All-in-One Solar Street Light 20 Watt, 12.8 Volt, 24 Amp Li-FePo4 Battery with Mppt Charge Controller Mono Solar Panel, including connection and testing complete all as specified and directed by Engineer-in-Charge. Make:- Crompton/Bajaj/Philips/Havells.
S&F of 2 Pole Power Contactors 25 Amps type MNX 25 complete all as per specified and directed. Make :- L&T /Havells/Schneider
S&F of 3 Pole Power Contactors 25 Amps type MNX 25 complete all as per specified and directed. Make :- L&T/Havells/Schneider
S&F 1.5 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable (Red/Black colour) complete all as specified and directed.
S&F in repair digital timer switch complete all as specified and directed. Make :- L&T /Havells/shcnider.
S&F in repair astronomical time switch complete all as specified and directed. Make :- L&T /Havells/shcnider.
S&F Nature switch sensor illuminate level for switching on < 30 lux and for switching off >10 lux alongwith part night operation facility of 4-12 hours complete all as specified and directed. Make CG/L&T/Havells
S&F Automatic street light switch using Nature Switch for automatic switching of street lights based on lux level of natural light. The sensor (Nature Switch) alongwith and including supply and fix of suitable power contactor of 1 Nos 40 Amps (Two pole ) two Nos MCB 63 Amps (single pole) and support terminals enclosed in pole /wall mountable enclosure of suitable size made out of rust proof electric shock proof termite proof and FR grade special moulding compound sintex make SMC junction box of suitable size confirming to IP54 circuit wiring suitable enough to take load of 8 KW single phase load, all as per Kadatiya Energy System Ltd Hydrabad Model SWADEEP or techno commercially equivalent models in Havells/ L & T complete all as specified and directed.
Taking LT shutdown, Dismantling and removing motor of the High mast light pole from existing position, Shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning complete all as specified and directed.
M&L for preparation of old painted surface of steel tubular street light poles and applying two coats of synthetic aluminum paint from top to bottom including light brackets complete all as specified and as directed.
M&L for structural steel work using rolled mild steel section of Fe-290 (Gde E-165) like Angles, flat, square, round bars as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc complete all as specified and directed.
M&L for cement concrete for filling in foundations or making good of Road, PCC Floor, supports etc. Type B1, 1:2:4, using 20 mm graded stone aggregate including necessary form work and fair finishing of exposed surface of concrete / facia finish with cement mortar complete all as specified and directed.
Attending of day to day street/ Security/ Gate light/Post top lantern/ High Mast light fixed at up to 15 mtr height LED Flood light/ LED Street light fitting etc of any make) complaints received through telephone or in person and rectification of defects installed on street light pole 9/11 mtr long building walls, roof by bringing down the fittings on ground or in position including replacement of LED Driver, flexible wire, etc including cleaning of glass/ acrylic cover for clear reflection of light , replacement of old unserviceaable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder,tools and takes as required at site for repair/ for making light functional shall be provided by the contractor at his own cost and arrangement. Note :- (i) light fitting, cable , flesible wire and LED drive if required to be replaced in repair shall be measered and paid separetely under relevant item of this BOQ for supply and fixing in replacement. (ii) contractor manpower shall report at complaint cell at 9;00 AM to JE E/M and report after completion of complaints and handover a complaint slip as record of complaints with user signature. (iii) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract. Note :- Recovery @ 120 per day of the complaints is not being attended within eight hours from intimation by rep of E/M subdivision through telephonic/digital/ written complaints.
Ajanta Motor Store
m/s allied enterprises
His And Her Enterprises
Puma Power
AIRDOT ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .