CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
IMPROVEMENT TO CERTAIN SMQS AT 25 ED UNDER GE AF OJHAR
2026_MES_797119_1
80796/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF OJHAR
PLEASE REF TENDER DOC
9 documents required · 9 mandatory
₹1,000
GE AF OJHAR
₹3.7 L
Yes
3 Nov 2026
3 Nov 2026
2 Dec 2026
3 Nov 2026
30 Nov 2026
24 Nov 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: HQ CWE (AF) NAGPUR
Name of Work: IMPROVEMENT CERTAIN SMQS AT 25 ED UNDER GE (AF ) OJHAR
Contract No: CWE (AF) / NGP /OJH/ OF 2026-27
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE inclusive of all taxes in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Quoted Amount in Words Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words
13 M&L brick work with fly ash bricks (FASB) conferming to IS 12894, of strength M-10 straight or curved on plan exc 6m mean radious built cement mortar 1:4 complete (on parapet wall) all as specified and as directed. 26.3 CUM Excess(+) Full Conversion INR
29 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete. 1418 RM Excess(+) Full Conversion INR
41 S&F 28-30 mm thick Prelaminated WPC factory made 100% Sketon/Glazed door (conforming as per IS-4020) shutter made from 100% lead free single extruded on both side with wood grain texture and with density not less than 650 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified 722.2 SQM Excess(+) Full Conversion INR
77.1 Note:- (i) For payment purpose only floor area shall be measured. (ii) After Coating of High penetration Nano ( Nano Bond Coat) Water proofing compound ponding test shall be carried out sunken surface with water for 72 Hrs and get approved by Engr-in-Charge if any leakage/ seepage noticed the Contractor will re do the whole process without any extra payment.
96 Construction Joints & Cracks treatment Open the construction joints/cracks in the top form V shape groove with approx. 25mm x 25mm size. Thereafter apply in-dagth waterproofing as a slurry application SmartCare Repair polymer mix with cement. (mixing rato of 1:1). Seal the groove with prepared in SmartCare Repair Mortar. (1:4) and polymer of 10% of weight of cement. (If required grout the joints through PVC injection nozzles fixed @1 c/c, using cement slurry grout with CBX100 cr equivalent added @250 gm per bag of cement to full saturation etc.) complete all as specified and directed. 250 RM Excess(+) Full Conversion INR
97.1 > Passes Resistance to Fatigue Movement Test @ -5 deg Celsius/ 1000 cycles as per EOTA: TR-008 > Resistance to low temperature by Dynamic Indentor @ 0 deg Celsius, 5.9 Joules Impact/10mm dia. indentor as per EOTA:TR-006 > Resistance to heat ageing - After exposure at 80 + 2°C for 200 days, the waterproofing membrane shall exhibit no more than 10% variation from the original values of tensile strength, elongation at break, dynamic indentation resistance and static indentation resistance when tested in accordance with the relevant ASTEOTA test methods. Evaluation shall be done as per AST D3045 & ASTM D573. Otherwise, this requirement shall be supported by an accredited laboratory report. > After immersion/exposure in water at 60 + 2°C for 180 days, the membrane shall exhibit no blistering, peeling, delamination or other visible defects upon visual inspection. > No chalking or flaking observed on exposure to aritificial weathering test in ATLAS Xenon arc reactor for 4200 hrs. The values of membrane performance for tensile strength, elongation at break & crack bridging ability values should not exhibit a change of more than 10% Note:- 1) The concrete surface shall be mechanically cleaned and prepared by removing dust, laitance, loose particles, oil, grease and all contaminants. Honeycombs, voids and cracks shall be repaired prior to application (quoted rate shall be inclusive of this aspect if not considered separately in any other item) 2) Contractor shall provide Manufacturer's warranty of 10 years against leakage. 3) Approved products shall be technically equivalent and shall satisfy or exceed all the specified performance requirements based on independent laboratory test reports. The contractor shall submit the manufacturer's technical data sheet, method statement, and third-party test certificates for approval of GE before procurement.
118 Point wiring with PVC insulated and unsheathed multistranded FRLSH copper conductor single core 1.5 sqmm (nominal area) cable using approved colour code as per IS drawing in and incl heavy duty PVC casing and capping confirming to IS: 14927 (Part – II) (ISI Marked CM/L 7487897) not less than 20 x 12 mm which shall be increased as per site requirement with all accessories suitable for modular type fitment including provision for fixing of modular flush boxes of suitable size complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLSH) copper conductor cable of size 1.5 mm as continuous earth wire connected to common earth dolly complete all specified and marking good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete and as directed .
118.1 One light point/Fan point controlled by one switch. 700 PER POINT Excess(+) Full Conversion INR
121 M & L for module cover plate with frame as per site requirements for following module complete all as specified and as directed. (Make ;- Legrand, Anchor penta, Havells, Indoasian)
122 M &L for modular metal flush box as per site requirement complete all as specified and as directed. (Make ;- Legrand, Anchor penta, Havells, Indoasian )
122.1 1/2 module 160 EACH Excess(+) Full Conversion INR
140 M & L sub main wiring using PVC insulated and unsheathed multistranded FRLSH copper conductor cable using approved colour code as per IS drawing in and intel PVC casing and capping with all accessories and making good disturbed surfaces of watt, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/color washing tom match with the existing surface complete as per specified and as directed by Engr-in-Charge of the following sizes of cables :-
140.1 Using two single core PVC insulated FRLSH cable 4.0 sqmm copper conductor multi standard and 4.0 sqmm copper conductor insulated cable using as earth wire Note : 2 runs of 4 sqmm copper cable ^ 1 run of 4.0 sqmm copper cable in and including PVC casing capping shall be measured as one unit. 600 RM Excess(+) Full Conversion INR
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
PS80796.pdf
Tender Documents • 1.64 MB
BOQ_894147.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .