Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.0 L+₹1.0 L (4.32%)Rejected-Finance AT DUNGAMAL NH 5 PO INS CHILKA DISTT KHORDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹25.2 L+₹1.3 L (5.44%)Rejected-Finance CAMP INS CHILKA CHHATRAGARH PO NB CHILKA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1. |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
12 Oct 2023, 6:00 pmClosed
GE CHILKA
GE CHILKA ODISHA-752037
ADDITION/ ALTERATION OF BUILDING NO P-82 (X-RAY DEPT) AND PROVISION OF DEFICIENT AIR CONDITIONER FOR FAMILY WARD AND DENTAL CENTRE AT INHS NIVARINI AT INS CHILKA UNDER GE CHILKA
2023_MES_618959_1
GE/CHL/8920 OF 2023-24
Open Tender
Civil Works
Works
180 days
GARRISON ENGINEER CHILKA
MES Enlisted contractor of Class E Category a i
7 documents required · 7 mandatory
₹500
Yes
GE CHILKA
₹52,000
Yes
1 Nov 2023
15 Sept 2023
14 Oct 2023
15 Sept 2023
12 Oct 2023
23 Sept 2023
15 Sept 2023 - 21 Sept 2023
Amount
Taking down existing waterproofing treatment complete of any description from brick or RCC wall and RCC slab by scrapping including removal of rubbish where directed to a distance not exceeding 100M and M&L for water proofing treatment to roof as per per manufacturer's instructions with the following specification:-. (a) 15 mm thick plastering in cement mortar 1:4 mixed with and including water proofing compound @3% by weight of cement including preperation of roof surfaces. (b) Applying evenly a coat of bitumineous primer @ 0.5 litre per Sqm (c) Applying evenly a coat of hot blow bitumen 85/25 grade @ 1.2 Kg per Sqm (d) Applying APP based polymeric membrane minimum 3 mm thick and minimum weighing 3kg/sqm laid on primed surface by LPG forced torch application with a side & end overlaps of minimum 100 mm. (e) Applying evenly a coat of hot blown bitumen 85/ 25 grade @ 1.2 Kg per Sqm over water proofing membrane (f) Applying a coat of bituminous based aluminium primer @ 100 gm/Sqm on top including sealing all joints by thermo fusion complete all as per manufacturer's instructions (g) Testing for water tightness by water ponding at least 72 hours
Supply only liquid water proofing compound.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 Sqm but not exc 0.18 sqm, in floors etc. Including on skirting upto 150 mm height, set and joint in neat cement slurry and pointed in white or colour cement to match the tiles fixed over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed
S&F Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match such as skirting / dado tiles fixed over and including 10 mm thick backing coat in CM (1:4) complete all as specified and directed.
S&F BARC Certified lead free Radiation shielding tiles in vertical surface 300x 300x 2mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match dado fixed over and including 10mm thik backing coat in CM 1:3 etc complete all as specified and directed.
S&F BARC Certified lead free Radiation shielding sheet 2mm thick as in door shutter surface fixed complete all as specified and directed.
M&L for 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination , fixed with screws to timber frame work all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls, ceilings, fins, fascias, chajjas, parapets etc. (including tiles) raking out joint, hacking for key, scrubbing down with water etc incl patches of any size complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick or concrete sufaces in cement mortar 1:6, including finishing even and smooth (without using extra cement) complete all as specified and as directed.
M&L for rendering 5mm thick on ceiling surfaces in CM 1:3 including finishing even & smooth (without using extra cement) complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat oil bound distemper over applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smoothcomplete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coat white wash complete all as specified and directed.
M&L for preparation old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces by brooming down or steel wire brushing, scraping down moulds, mass and efflorenscent salts and greasy spots of wall and applying one coat of oil emulsion distemper of approved shade on wall complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scraping down moulds, mass and efflorenscent salts and gressy spots and applying two coat of white wash on walls complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scraping down moulds, mass and efflorenscent salts and gressy spots and applying two coat of white wash on ceiling complete all as specified and directed.
M&L for 3.5 mm thickness rubber sheet with fabric backing or insert and plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) all as specified.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each but with shutters (without taking off shutters from the frames) all as specified.
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as specified and as directed.
S&F 25 mm thickness of flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame at site as per specification & drawing as directed
S&F mediam weight, cold rolled mild steel butt hinges of 125mm size, complete all as specified and as directed.
S&F extruded aluminium alloy handles, 125mm long fabricated type, anodised all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section, length of bolt 150mm complete all as specified and as directed.
S&F 250 mm long aluminium anodised, sliding door bolts, with haps staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of sxtruded section or cast aluminium alloy complete all as specified and as directed
S&F Powder coated of any colour anodized aluminum frame (minimum thickness of powdere coating 50 micron) for door/windows/ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated of any colour (thickness of powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified. (Note : glass and paticle board shall be measured seperatly.)
S&F anodised powder coating of any colour (Thickness or powder coating not less than 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F 4.8mm glass frosted on one side, in squares n exc 0.5 sq. m in each pan all as specified and as directed.
S&F 5.5 mm thick of Sheet glass, ordinary quality and glazing in square n exc 0.5 sq. m in each panefixed etc all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples including necessary beadings complete all as specified and as directed
S&F 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination lamination, fixed with screws in aluminium door complete all as specified and directed by Engineer-in-Charge.
S&F 4 mm thickness of sheet glass, ordinary quality and glazing in square n exc 0.5 sq. m in each pane all as specified and as directed.
M&L for preparation of new painted wooden surfaces of any description not otherwise described over 10 cm width or girth of any and applying two coat of synthetic enamel paint over coat of primer of approved shade complete all as specified and directed.
S&F semi perforated 12mm thick micro tegular edged GRG false ciling tiles at all height with GRG (Glass fibre reinforced gypsum) false ceiliing tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2%,humidity resistance of 99% , NRCO 0.50 to 0.75 as per IS 8225 : 1987 , noncombustible as per BS 476 (Part-4) 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of 0.33mm thick (galvanised @ 120 grams per sqm including both sides ) comprising of amin T runners of size 15x32mm of length 3000 mm , cross T of size 15x32 of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) ie 50mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shaped level adjuster of size 85x25x2mm, galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on priphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws & including taking down / dismantling of existing ceiling board with frame work of any description etc all complete. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed.
M&L for brick work with fly ash bricks, straight or curved on plain exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for RCC type B1 (1:2:4) using 20 mm grade aggregate as in shelves and the like complete all as specified and as directed.
M&L for RCC type B1 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc all complete
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm screed bed of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed in CM (1:4) complete all as specified and directed.
S&F in repair aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg all as specified and as directed.
S&F floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F in repair water closet pedestal vitreous china white pattern (EWC) including white colour seat cover and connection to drain and to flush pipe & mild steel chromium plated or aluminised hinging device etc (excluding flushing cistern and flush pipe) including 100mm bore traps P or Scomplete all as specified and directed.
S&F in repairs PVC low level flushing cistern of 10 ltr capacity fixed including syphonic action type, ball valve, float and handle including brackets etc complete all as specified and directed
S&F in repairs toilet paper holder with flat recessed type of brass, chromium plated or stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed
S&F in repairs PVC connections 15 mm size with PTMT nuts and washers for 600mm long pipe complete all as specified and directed
S&F in repair 15mm bore dia CP two way bib tap cast copper ally fancy type screwed down high pressure, with long shank screwed and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified.
S&F in repair PVC soap tray fixing with screw in the all as specified
S&F CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all specified and as directred.
S&F in repairs wash hand basin with pedestal vitreous china white flat back of size 580 X 450mm with brackets, complete all as specified and as directed.
S&F in repair 15mm bore dia fancy type Pillar taps, cast copper alloy, with or without lettered Hot or cold with capstan heads, chromium plated, crewed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 32/40mm bore and 80 cm long PVC waste pipe for WHB, sink complete all as specified and as directed.
S&F in repair for 40mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F in repairs angle valves of 15 mm dia chromium plated fancy type screwed down high pressure screwed at the ends for iron pipe or union with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge (Make : Parryware,Cat No G5307A1)
S&F in repairs 25mm bore of tubes, 'medium grade'galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs 15mm bore of tubes, 'medium grade'galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair PVC floor trap with grating including jointing with solvent cement to waste pipe 75 mm dia
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls & floors 110 mm bore.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls & floors 75 mm bore.
S&F in repairs 110 bore PVC (SWR) bends any radius complete all as specified and directed
S&F in repairs110 bore PVC (SWR) vent cowl complete all as specified and directed
S&F in repairs 75 bore PVC (SWR) junction single, (Single T) equal or unequal with access doorcomplete all as specified and directed
S&F in repairs 75 bore PVC (SWR) bends any radius with access door complete all as specified and directed
S&F in repairs 75 bore PVC (SWR) bends any radius complete all as specified and directed
S&F in repairs 75 bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of1000 ltr capacity including provision of inlet, outlet overflow and wash out connections Complete all as specified and as directed.
S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed with necessary fittings for iron pipe size 20 mm dia/bore and fixed (Minimum weight 20mm-210 gms)
S&F in repair gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repairs of size 20 mm dia/bore complete all as specified & directed.
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F welded steel wire n exc 4 Kg/Sqm fabric supplied and fixed complete to wood or steel members complete all as specified and as directed.
M&L for preparing of surfaces of steel for painting of any description, over 10cm in width or girth, on new surface over a coat of primer of red oxide zinc and two coat of synthetic enamelled paint over it all as specified and as directed.
S&F Aluminium anodised powder coated of any colour (thickness of powder coating not less than 15 micron) with Deco grill aperature size 50X50mm fixed with suitable channel for windows/ventelator fixing arrangements all as specified and as directed.
Taking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in surface PVC Casing-Caping not less than 20mm width with pressed steel in concealed MS box duly including covered with 3 mm thick hylem sheets for mounting switches/Sockets, accessories such as spacers, saddles, junction boxes For one light point controlled by one switch.
For one Ceiling/Exhaust Fan point controlled by one swtich
For one socket point 5 Amps on the independent board
For one socket point 5 Amps on same board
Ditto all as per above item but using 4 sq mm single core copper conductor cable of multistrand FRLS grade PVC insulated Unshethed 1100 volt grade for 16 Amps socket combination pt. including running of 4 sq mm copper conductor FRLSH PVC wire as earth continuety conductor along with wiring and connecting to common earth dolly for One 6 pin multi socket outlet, 16 Amps , independent all as specified and directed.
S & F Switch socket combination 5 in 1, 5 /15 A 5 in 1 flush type. complete all as specified and as directed. Make: Anchor/Havells.
S & F switch sockets combnation 2 in 1, 6 amps flush type complete all as specified and directed.
S & F ceiling rose 3 terminal PVC/polycarbonate isoloted body complete all as specified and directed.
S&F switch piano flush type single pole, one way 5 Amps 230 volt complete all as specified and directed.
Supply & fix in repairs LED light fitting 1 x 10 Watt, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as direected. Cat part no D531065 of .Make Wipro or its equivalent in philips/Crompton/ Bajaj
Supply & fix in repairs LED light fitting 1 x 20 Watt, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as direected. Cat part No BN100CLED20S-6500 PSUL120GR S4 of Make Phillips or its equivalent in Wipro/Crompton/Bajaj
S &F stepped type electronic fan regulator 230 volt suitable for 1200mm/1400 mm sweep celing fan including necessary electric connection complete all as specified and directed.(Make: Anchor or equivalent)
Supply and Fix Ceilling Fan white/Ivory in colour complete with blades, down rods and accessories, 230 V, 1200 mm Sweep,min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC)Make : Khaitan/Crompton Greaves/Usha
Supply and fix of exhaust Fans, steel body 300mm sweep with blades and frame and louvers, heavy duty, AC single phase, 230 volts including connection with multistranded copper conductor flexible wire of suitable size from ceiling rose, necessary fixing arrangement i.e anchor nut, bolt, washer and grouting and making good to disturbed surface complete all as specified and as directed. Make :/Khaitan/Almonard/Crompton
S&F in repairs sub main wiring with 2 runs of 4 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in concealed PVC conduit not less than 25mm dia and one run of PVC insulated unserviceable of 4sqmm as earth continuity conductor drawn in PVC Conduit with accessories complete NOTE: 3 runs of 4 Sqmm and 1 run of conduit will be measured as one unit i.e RM (ii) Cutting,chasing,pinning are also included in quoted rate.
S&F in repairs sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity.
Supply,install and commission hi wall split AC units indoor/outdoor,electric driven single phase,50 HZ,240 volt,inverter type with rotary compressor and refrigerant type-R32/404, complete with in built inverter,LCD, cordless remote control unit,timer and with in built air ioniser and plasa filter for better indoor air quality with minimum 5 star rating and EER 3.2 capacity 1.5 TR complete.Make Hitachi/ Model RSRGS18FFEO or its equivalent in Voltas/Blue star/LG/Daikine
S& F 5 KVA auto corrector single phase,sine wave,240 volts,AC supply,50 Hz and Conforming to IS;8448 all complete as specified and directed.
S & F in repairs MCB DB double door TPN 4 Way with 200 Amps rated copper bus bar 240 Volt, IP 43- Metal door. complete all as specified and as directed
S&F in repairs MCB TPN 40-100 Amp, 240 Volt C curve. complete all as specified and as directed. Make: Havells/Legrand/L&T.
S&F in repairs MCB SP 6 to 32 Amp, 240 Volt C curve complete all as specified and as directed. Make: Havells/Legrand/L&T.
M&L for Earthing complete with GI earth plate electronic 600 x 600x 6mm buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge of earth plate at a depth of not less than 1.5 mtr below ground level connected to GI earth lead 4 mm dia by means of nuts bolts washers etc made out of galvanized iron and GI wire connected to main switch/DB board including necessary excavation and earth work PCC (1 3 6) type C1 using 20mm graded stone aggregate earth chamber 40mm thick RCC cover type B1 (1 2 4 ) B1 using 20mm graded stone aggregate 20mm dia GI medium grade protection pipe upto main switch board etc complete all as shown in electrical plate No 3 of MES Schedule Part I.
Taking down carefully electric cables of any size or any capacity from both ends (i.e., from LT Panels and DB's) and refixing the same duly clamped with appropriate size of saddles in cable trays without distrubing the existing good one cable trays complete all as specified and directed by Engr-in-charge.
Supply,fabrication and fixing of GI Sheet 20/22 SWG to cover the cable etc.. Including reviets/nut bolts and all as directed
Supply,fabrication and fixing of Angle iron / flat iron for supporting of cable/cable tray and all as directed
S&F 3mm thick aluminium clading to existing cable trunking to stucco for plain of approved colour shade as required cutting, notching to shape and jointing aluminium tublar section as required
S& F of GI Cable tray perforated type ,2mm thick of size 600mmx50mm and including all fixing arrangement and all as directed
M&L for sub main wiring with 2 runs of 4 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in concealed PVC conduit not less than 25mm dia and one run of PVC insulated unsheathed of 4 sqmm as earth continuity conductor drawn in concealed PVC Conduit with accessories complete NOTE: 3 runs of 4 Sqmm and 1 run of conduit will be measured as one unit i.e RM
S&F sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity.
Supply & fix MCB SP 6 to 32 Amps rating 240 Volts, 10 KA, C curve. Complete with connection testing and commissioning. Make-L&T/Schneider/Legrand
Supply and fix room window type air conditioner electric driven (single phase), cooling capacity 1.0 Ton BEE 5 star rated and EER 3.61 having Copper Condenser complete. Make Hitachi/ Voltas/ Daikine/ Blue star
UDAYA BHANU NAYAK
HARI PALAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .