Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹90.0 LAdmitted-Finance | -14.89% | ₹90.0 L | L1 | Admitted-Finance |
| 2 | L2₹92.5 LAdmitted-Finance HAROPARA PART 1 P O JHAROBARI P S PALASHBARI DIST KAMRUP PIN 781122 | KAMRUP | ASSAM | 781122 | -12.53% | ₹92.5 L | L2 | Admitted-Finance |
| 3 | L3₹1.1 CrAdmitted-Finance | +6.56% | ₹1.1 Cr | L3 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
25 Mar 2026, 3:00 pmClosed
GM I/C (Mtls and Contracts)
INDIAN OIL CORPORATION LIMITED (MARKETING DIVISION) EASTERN REGIONAL OFFICE IndianOil Bhavan, 7th Floor, East Wing, 2, Gariahat Road (South), Dhakuria, Kolkata-700068
Development of new A site Retail Outlet FROM KM STONE 63 TO KM STONE 82 VIA NONGSTOIN BYPASS ON NH 44-OLD-NH under Guwahati DO
2026_ERO_189243_1
MAC/ERO/37/2025-26/PT-83
Open Tender
Civil Works
105 days
FROM KM STONE 63 TO KM STONE 82 VIA NONGSTOIN BYPA
As per tender document
5 documents required · 5 mandatory
₹32,000
Yes
IOCL,ERO,KOLKATA
9 Apr 2026
11 Mar 2026
26 Mar 2026
11 Mar 2026
25 Mar 2026
17 Mar 2026
16 Mar 2026
STATEMENT OF CREDENTIAL & BID SUBMISSION CHECKLIST
Tender Ref. No.: MAC/ERO/37/2025-26/PT-83 Name of Work: Development of new A site Retail Outlet "FROM KM STONE 63 TO KM STONE 82 VIA NONGSTOIN BYPASS ON NH 44(OLD)/NH under Guwahati DO
Note: 1.Bidders have to submit duly filled Statement of Credentials. Data is to be filled by the Bidders only in WHITE coloured cells. 2. Necessary supporting documents to be enclosed. 3. Corporation reserves the right to assess the bidder’s capacity and capability if necessary by visiting/ inspecting recently executed / under execution of works.
S N Particulars Details Uploaded:
(A) General Information
1 Name of the bidder:
2 Address of the Bidder
3 Login E-Mail id for portal
4 Correspondence E-Mail id as per portal
5 Name of Contact Person:
6 Contact Person's Mobile no -
7 Company details: Type of Firm
8 Copy of PAN card (For Indian bidders / Indian Agents of Foreign Bidders)
9 Copy of GST Registration (For Indian bidders / Indian Agents of Foreign Bidders)
10 Copy of PF registration
11 Partnership deed (For Indian bidders – The deed should be registered with Registrar of Firms)
Certificate of Incorporation with memorandum and articles of Association (as applicable for partnership firms and companies)
1 Earnest Money Deposit Instrument Ref:
(C) PQC Documents
2 Turn Over Criteria (In Rs.)
2.1 FY 2024-25 UDIN no.:
2.2 FY 2023-24 UDIN no.:
2.3 FY 2022-23 UDIN no.:
3 Similar Work: Work completed by the bidder, as main contractor, or as sub-contractor, during last seven years ending last day of month previous to the original end date of bid submission. The value of completed work for evaluation shall be considered as under:
3.1 1st Work Order
a Description of Work/Purchase/Services
b Name of Client with Address
c Contact Person & Contact detail of End client
d E-mail id of End Client
e WO/PO Ref No / Date / Amount
f Schedule of Rates/ Scope of Works Document
g Completion Certificate Ref No / Date / Amount/Actual Executed Amount of Work
h Date of Actual Completion as per Completion Certificate
i TDS Certificate/Bank Statement for proof of payment
j CA certificate for executed work
k Certificate from the end user / owner / consultant of the owner acting as EIC stating that the main contractor has intimated them about the engagement of sub-contracting OR have been allowed/ permitted as a subcontractor (IF APPLICABLE)
3.2 2nd Work Order
a Description of Work/Purchase/Services
b Name of Client with Address
c Contact Person & Contact detail of End client
d E-mail id of End Client
e WO/PO Ref No / Date / Amount
f Schedule of Rates/ Scope of Works Document
g Completion Certificate Ref No / Date / Amount/Actual Executed Amount of Work
h Date of Actual Completion as per Completion Certificate
i TDS Certificate/Bank Statement for proof of payment
j CA certificate for executed work
k Certificate from the end user / owner / consultant of the owner acting as EIC stating that the main contractor has intimated them about the engagement of sub-contracting OR have been allowed/ permitted as a subcontractor (IF APPLICABLE)
3.3 3rd Work Order
a Description of Work/Purchase/Services
b Name of Client with Address
c Contact Person & Contact detail of End client
d E-mail id of End Client
e WO/PO Ref No / Date / Amount
f Schedule of Rates/ Scope of Works Document
g Completion Certificate Ref No / Date / Amount/Actual Executed Amount of Work
h Date of Actual Completion as per Completion Certificate
i TDS Certificate/Bank Statement for proof of payment
j CA certificate for executed work
k Certificate from the end user / owner / consultant of the owner acting as EIC stating that the main contractor has intimated them about the engagement of sub-contracting OR have been allowed/ permitted as a subcontractor (IF APPLICABLE)
(D) OTHER ESSENTIAL COMMERCIAL CRITERIA:
1 Copy of PAN card (For Indian bidders / Indian Agents of Foreign Bidders)
2 Copy of GST Registration (For Indian bidders / Indian Agents of Foreign Bidders)
3 Copy of PF registration
4 Power of Attorney / Authority of the person uploading the bids / Board Resolution along with
a) Certificate of incorporation (COI), Memorandum of Association (MOA) and Articles of Association (AOA) in case of Company. Or
b) Partnership Deed, Or
c) Declaration of sole proprietor
(E) OTHER DOCUMENTS:
1 Undertaking by the Tenderer(s) on acceptance of tender terms & conditions- Annexure ‘A’ of Technical Bid Part-B.
2 Declaration on Proceedings Under Insolvency and Bankruptcy Code, 2016 (Bidding Stage)- Annexure ‘B’ of Technical Bid Part-B.
3 Compliance Certificate for bidders from a country which shares a land border with India- Annexure ‘C’ of Technical Bid Part-B.
4 Undertakings and declarations for non-tampering of data- Annexure ‘D’ of Technical Bid Part-B.
5 Declaration of blacklisting / holiday listing clearly mentioning the details of Holiday listing or "NIL" in case of no details - Annexure ‘E’ of Technical Bid Part-B.
6 Details on Relationship with IOCL's Directors (Declaration "A", "B"& "C") - Annexure ‘F’ of Technical Bid Part-B.
7 Undertaking for business transaction status of bidders- Annexure ‘G’ of Technical Bid Part-B.
8 Particulars of bidder firm- Annexure ‘H’ of Technical Bid Part-B.
9 Undertaking on no multiple bidding- Annexure ‘I’ of Technical Bid Part-B.
10 Declaration for availing Purchase Preference on purchase preference (PP-MII) policy) – Bid Stage - Annexure ‘J (Part-I)’ of Technical Bid Part-B.
11 Declaration on purchase preference (linked with local content) (PP-MII) policy- Annexure ‘J (Part-II)’ of Technical Bid Part-B.
Percentage BoQ NQ
Select, At Par, Excess (+), Less (-) IOCL Select Excess (+) Less (-) At Par (=) Not Quoted Select Excess (+) Less (-) At Par (=)
Tender Inviting Authority: General Manager I/c (Materials & Contract), Eastern Regional Office
Name of Work: Development of new A site Retail Outlet "FROM KM STONE 63 TO KM STONE 82 VIA NONGSTOIN BYPASS ON NH 44(OLD)/NH under Guwahati DO
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Qty Units Estimated Rate IN Rs. P. Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P GST PERCENT (%) Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 LAND DEVELOPMENT item_code_1
2 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises item_code_2 M2 Excess(+) Full Conversion INR
3 CONSTRUCTION OF SALES BUILDING item_code_3
4 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_4
5 i) All kinds of Soil item_code_5 M3 Excess(+) Full Conversion INR
6 Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil item_code_6 M3 Excess(+) Full Conversion INR
7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m item_code_7 M3 Excess(+) Full Conversion INR
8 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. item_code_8
9 i) Local Fine Sand within grading zone IV item_code_9 M3 Excess(+) Full Conversion INR
10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil item_code_10 M2 Excess(+) Full Conversion INR
11 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_11 M2 Excess(+) Full Conversion INR
12 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: item_code_12
13 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) item_code_13 M3 Excess(+) Full Conversion INR
14 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) item_code_14 M3 Excess(+) Full Conversion INR
15 viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) item_code_15 M3 Excess(+) Full Conversion INR
16 Centering and shuttering including strutting, propping etc. and removal of form work for: item_code_16
17 i) Foundations,footings,bases of column item_code_17 M2 Excess(+) Full Conversion INR
18 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_18
19 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_19 M3 Excess(+) Full Conversion INR
20 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : item_code_20
21 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_21 M3 Excess(+) Full Conversion INR
22 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) item_code_22 M3 Excess(+) Full Conversion INR
23 Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). item_code_23 M3 Excess(+) Full Conversion INR
24 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_24
25 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_25 M2 Excess(+) Full Conversion INR
26 v) Columns, Pillars, Piers, Abutments, Posts and Struts. item_code_26 M2 Excess(+) Full Conversion INR
27 vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards item_code_27 M2 Excess(+) Full Conversion INR
28 viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick item_code_28 M2 Excess(+) Full Conversion INR
29 ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick item_code_29 M2 Excess(+) Full Conversion INR
30 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_30
31 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_31 KG Excess(+) Full Conversion INR
32 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth item_code_32
33 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH item_code_33 M3 Excess(+) Full Conversion INR
34 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH item_code_34 M2 Excess(+) Full Conversion INR
35 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks item_code_35 M2 Excess(+) Full Conversion INR
36 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: item_code_36 KG Excess(+) Full Conversion INR
37 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover item_code_37 M2 Excess(+) Full Conversion INR
38 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement item_code_38 M2 Excess(+) Full Conversion INR
39 Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. item_code_39 M2 Excess(+) Full Conversion INR
40 Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. item_code_40 M2 Excess(+) Full Conversion INR
41 Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified item_code_41
42 i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 item_code_42 M2 Excess(+) Full Conversion INR
43 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. item_code_43
44 iv) Granite of any colour and shade having Area of slab over 0.50 sqm item_code_44 M2 Excess(+) Full Conversion INR
45 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) item_code_45 M2 Excess(+) Full Conversion INR
46 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. item_code_46
47 ii) 110 mm diameter item_code_47 M- Excess(+) Full Conversion INR
48 Providing and laying cement plaster on surfaces with fine sand including curing etc. item_code_48
49 ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) item_code_49 M2 Excess(+) Full Conversion INR
50 Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. item_code_50
51 i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) item_code_51 M2 Excess(+) Full Conversion INR
52 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. item_code_52 M2 Excess(+) Full Conversion INR
53 Painting top of roofs with residual type petroleum bitumen of grade VG10 of approved quality at 17kg per10sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil complete. item_code_53 M2 Excess(+) Full Conversion INR
54 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete item_code_54 M2 Excess(+) Full Conversion INR
55 Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) item_code_55 M2 Excess(+) Full Conversion INR
56 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm item_code_56 M2 Excess(+) Full Conversion INR
57 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. item_code_57 M2 Excess(+) Full Conversion INR
58 Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. item_code_58 EA Excess(+) Full Conversion INR
59 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: item_code_59
60 i) W.C. pan with ISI marked white solid plastic seat and lid item_code_60 EA Excess(+) Full Conversion INR
61 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : item_code_61
62 i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern item_code_62 EA Excess(+) Full Conversion INR
63 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : item_code_63
64 i) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps item_code_64 EA Excess(+) Full Conversion INR
65 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. item_code_65 EA Excess(+) Full Conversion INR
66 Providing and fixing toilet paper holder : item_code_66
67 i) C.P. brass item_code_67 EA Excess(+) Full Conversion INR
68 Providing and fixing soil, waste and vent pipes : item_code_68
69 i) 100mm dia Sand cast iron S&S pipe as per IS: 1729. item_code_69 M- Excess(+) Full Conversion INR
70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall item_code_70
71 i) 15 mm nominal outer dia Pipes item_code_71 M- Excess(+) Full Conversion INR
72 ii) 20 mm nominal outer dia Pipes item_code_72 M- Excess(+) Full Conversion INR
73 iii) 25 mm nominal outer dia Pipes item_code_73 M- Excess(+) Full Conversion INR
74 v) 40 mm nominal outer dia Pipes item_code_74 M- Excess(+) Full Conversion INR
75 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. item_code_75
76 ii) 20 mm nominal outer dia Pipes item_code_76 M- Excess(+) Full Conversion INR
77 iii) 25 mm nominal outer dia Pipes item_code_77 M- Excess(+) Full Conversion INR
78 Providing and fixing brass bib cock of approved quality : item_code_78
79 i) 15 mm nominal bore item_code_79 EA Excess(+) Full Conversion INR
80 Providing and fixing brass stop cock of approved quality : item_code_80
81 i) 15 mm nominal bore item_code_81 EA Excess(+) Full Conversion INR
82 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : item_code_82
83 i) 25 mm nominal bore item_code_83 EA Excess(+) Full Conversion INR
84 iii) 40 mm nominal bore item_code_84 EA Excess(+) Full Conversion INR
85 Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : item_code_85
86 i) 100mm inlet & 100mm outlet SCI S&S as per IS - 3989. item_code_86 EA Excess(+) Full Conversion INR
87 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank item_code_87 L- Excess(+) Full Conversion INR
88 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) item_code_88
89 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections item_code_89 KG Excess(+) Full Conversion INR
90 iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) item_code_90 KG Excess(+) Full Conversion INR
91 Providing and fixing panelling or panelling and glazing in panelled or panelled & glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : item_code_91
92 ii) 12mm thick particle board with Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS:3097, Grade I item_code_92 M2 Excess(+) Full Conversion INR
93 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): item_code_93
94 ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) item_code_94 M2 Excess(+) Full Conversion INR
95 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. item_code_95
96 ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) item_code_96 KG Excess(+) Full Conversion INR
97 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). item_code_97 M2 Excess(+) Full Conversion INR
98 Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). item_code_98 EA Excess(+) Full Conversion INR
99 Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : item_code_99
100 i) 250x10 mm item_code_100 EA Excess(+) Full Conversion INR
101 ii) 200x10 mm item_code_101 EA Excess(+) Full Conversion INR
102 Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : item_code_102
103 i) 125 mm item_code_103 EA Excess(+) Full Conversion INR
104 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. item_code_104
105 i) With stainless steel cover plate minimum 1.25 mm thickness item_code_105 EA Excess(+) Full Conversion INR
106 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge. item_code_106
107 i) Powder coated minimum thickness 50 micron aluminium tubular handle bar item_code_107 EA Excess(+) Full Conversion INR
108 Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and direction of Engineer-in-charge item_code_108
109 i) Non Decorative finish item_code_109 M2 Excess(+) Full Conversion INR
110 CONSTRUCTION OF SEPTIC TANK & SOAK PIT item_code_110
111 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_111
112 i) All kinds of Soil item_code_112 M3 Excess(+) Full Conversion INR
113 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_113 M2 Excess(+) Full Conversion INR
114 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_114
115 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_115 M3 Excess(+) Full Conversion INR
116 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_116
117 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) item_code_117 M2 Excess(+) Full Conversion INR
118 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_118
119 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_119 KG Excess(+) Full Conversion INR
120 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth item_code_120
121 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH item_code_121 M3 Excess(+) Full Conversion INR
122 Providing and laying cement plaster on surfaces with fine sand including curing etc. item_code_122
123 ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) item_code_123 M2 Excess(+) Full Conversion INR
124 Providing Neat cement punning item_code_124 M2 Excess(+) Full Conversion INR
125 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth item_code_125
126 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH item_code_126 M2 Excess(+) Full Conversion INR
127 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 item_code_127 EA Excess(+) Full Conversion INR
128 CONST. OF BOX CULVERT WITH OPEN DRAIN item_code_128
129 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_129
130 i) All kinds of Soil item_code_130 M3 Excess(+) Full Conversion INR
131 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_131 M2 Excess(+) Full Conversion INR
132 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_132
133 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_133 M3 Excess(+) Full Conversion INR
134 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_134
135 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_135 M2 Excess(+) Full Conversion INR
136 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_136
137 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_137 KG Excess(+) Full Conversion INR
138 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth item_code_138
139 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH item_code_139 M3 Excess(+) Full Conversion INR
140 Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. item_code_140 KG Excess(+) Full Conversion INR
141 Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. item_code_141
142 i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) item_code_142 M2 Excess(+) Full Conversion INR
143 Providing Neat cement punning item_code_143 M2 Excess(+) Full Conversion INR
144 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. item_code_144
145 ii) 110 mm diameter item_code_145 M- Excess(+) Full Conversion INR
146 CONSTRUCTION OF DRIVEWAY, APPROACH & BUFFER STRIP item_code_146
147 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. item_code_147
148 i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired item_code_148 M3 Excess(+) Full Conversion INR
149 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge item_code_149 M3 Excess(+) Full Conversion INR
150 Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) item_code_150
151 ii) M40 grade 80 mm thick reflective type Lacquered finish item_code_151 M2 Excess(+) Full Conversion INR
152 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_152
153 i) All kinds of Soil item_code_153 M3 Excess(+) Full Conversion INR
154 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_154 M2 Excess(+) Full Conversion INR
155 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: item_code_155
156 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) item_code_156 M3 Excess(+) Full Conversion INR
157 Centering and shuttering including strutting, propping etc. and removal of form work for: item_code_157
158 i) Foundations,footings,bases of column item_code_158 M2 Excess(+) Full Conversion INR
159 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_159
160 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_160 M3 Excess(+) Full Conversion INR
161 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_161
162 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_162 M2 Excess(+) Full Conversion INR
163 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_163
164 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_164 KG Excess(+) Full Conversion INR
165 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth item_code_165
166 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH item_code_166 M3 Excess(+) Full Conversion INR
167 Providing and laying cement plaster on surfaces with fine sand including curing etc. item_code_167
168 ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) item_code_168 M2 Excess(+) Full Conversion INR
169 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/perlite respectively conforming to IS:2547 (Part - I & II), applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : item_code_169 M2 Excess(+) Full Conversion INR
170 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete item_code_170 M2 Excess(+) Full Conversion INR
171 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. item_code_171 M2 Excess(+) Full Conversion INR
172 CONSTRUCTION OF CANOPY OF 12M*16M SIZE item_code_172
173 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_173
174 i) All kinds of Soil item_code_174 M3 Excess(+) Full Conversion INR
175 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. item_code_175
176 i) Local Fine Sand within grading zone IV item_code_176 M3 Excess(+) Full Conversion INR
177 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_177 M2 Excess(+) Full Conversion INR
178 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_178
179 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_179 M3 Excess(+) Full Conversion INR
180 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_180
181 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_181 M2 Excess(+) Full Conversion INR
182 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_182
183 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_183 KG Excess(+) Full Conversion INR
184 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : item_code_184
185 v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate item_code_185 EA Excess(+) Full Conversion INR
186 Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 item_code_186 EA Excess(+) Full Conversion INR
187 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty item_code_187
188 ii) 150 mm dia. R.C.C. pipe item_code_188 M- Excess(+) Full Conversion INR
189 iv) 300 mm dia. R.C.C. pipe item_code_189 M- Excess(+) Full Conversion INR
190 Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil item_code_190
191 iv) Pipes, Cable etc. > 80mm < 300m dia item_code_191 M- Excess(+) Full Conversion INR
192 Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. item_code_192
193 ii) Plain Sheet for Ridges (500 - 600mm). item_code_193 M- Excess(+) Full Conversion INR
194 iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) item_code_194 M- Excess(+) Full Conversion INR
195 iv) Plain Sheet for Gutter (600 mm over all girth) item_code_195 M- Excess(+) Full Conversion INR
196 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. item_code_196
197 iii) 160 mm diameter item_code_197 M- Excess(+) Full Conversion INR
198 Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. item_code_198 M2 Excess(+) Full Conversion INR
199 Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. item_code_199 M2 Excess(+) Full Conversion INR
200 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: item_code_200 KG Excess(+) Full Conversion INR
201 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_201
202 iii) 3 Core x 1.5 sq. mm. (copper) item_code_202 M- 99.96 Excess(+) Full Conversion INR
203 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS item_code_203 M- 132.536 Excess(+) Full Conversion INR
204 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. item_code_204
205 vii) 3 Core x 2.5 sq. mm item_code_205 EA Excess(+) Full Conversion INR
206 Providing, fixing, testing and commissioning of FLP junction box of approved make for cable connection/ jointing. item_code_206
207 i) For cables 2.5 to 4 sqmm XLPE / AYFY item_code_207 EA Excess(+) Full Conversion INR
208 S/F Under Canopy recess mounted Linear LED Lights item_code_208 EA Excess(+) Full Conversion INR
209 CONSTRUCTION OF DOUBLE SIDED HOARDING item_code_209
210 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_210
211 i) All kinds of Soil item_code_211 M3 Excess(+) Full Conversion INR
212 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m item_code_212 M3 Excess(+) Full Conversion INR
213 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_213 M2 Excess(+) Full Conversion INR
214 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: item_code_214
215 ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm) item_code_215 M3 Excess(+) Full Conversion INR
216 Providing and laying cement plaster on surfaces with fine sand including curing etc. item_code_216
217 ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) item_code_217 M2 Excess(+) Full Conversion INR
218 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: item_code_218 KG Excess(+) Full Conversion INR
219 Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution item_code_219 M2 Excess(+) Full Conversion INR
220 Centering and shuttering including strutting, propping etc. and removal of form work for: item_code_220
221 i) Foundations,footings,bases of column item_code_221 M2 Excess(+) Full Conversion INR
222 Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. item_code_222 EA Excess(+) Full Conversion INR
223 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. item_code_223
224 vi) 3 Core x 1.5 sq. mm. item_code_224 EA Excess(+) Full Conversion INR
225 vii) 3 Core x 2.5 sq. mm item_code_225 EA Excess(+) Full Conversion INR
226 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_226
227 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS item_code_227 M- Excess(+) Full Conversion INR
228 i) 2 Core x 1.5 sq. mm. (copper) item_code_228 M- Excess(+) Full Conversion INR
229 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : item_code_229
230 v) 25 x 3 mm GI strip item_code_230 M- Excess(+) Full Conversion INR
231 Supply & fixing of weatherproof 125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL make including clamping arrangement, all complete as per specification & direction of Engineer In-charge. item_code_231 EA Excess(+) Full Conversion INR
232 TRANSPORTATION AND INSTALLATION OF TANKS item_code_232
233 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) item_code_233
234 iii) 15/20 KL Tank with fittings : 0 - 30 Km item_code_234 LS Excess(+) Full Conversion INR
235 iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km item_code_235 KM Excess(+) Full Conversion INR
236 Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 item_code_236
237 iv) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/318. Manhole cover plates and frame to be paid separately . item_code_237 LS Excess(+) Full Conversion INR
238 Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. item_code_238 M- Excess(+) Full Conversion INR
239 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. item_code_239
240 i) Local Fine Sand within grading zone IV item_code_240 M3 Excess(+) Full Conversion INR
241 Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 item_code_241 EA Excess(+) Full Conversion INR
242 Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve item_code_242
243 iii) S/I Screwed type GM Ball Valve of 50 mm dia item_code_243 EA Excess(+) Full Conversion INR
244 Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein item_code_244
245 iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein item_code_245 EA Excess(+) Full Conversion INR
246 Making flanged joints between flanges slip on, blind and flange etc. including providing/supplying 3 mm thick permanite oil gasket, nuts, bolts, bonding with 3 mm dia copper wire etc.complete as per IOCL specifications. item_code_246
247 i) Making Flange joint between Slip on,blind and flange etc.of 100mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding item_code_247 EA Excess(+) Full Conversion INR
248 Supplying and installation of the following threaded coupling item_code_248
249 i) 80 mm dia Aluminium camlock coupling - Male only item_code_249 EA Excess(+) Full Conversion INR
250 Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. item_code_250
251 i) Supply & installation of U type CS bend on vent pipe of 80 mm dia item_code_251 EA Excess(+) Full Conversion INR
252 Providing stainless steel wire mesh 32 SWG, 11 mesh per linear cm of of non corrosive metal in two layers on existing vent hoods ‘U’ type (on both ends) including brazing, etc. complete item_code_252
253 i) 32SWG SS wire mesh both sides of existing U vent hood 80mm dia item_code_253 EA Excess(+) Full Conversion INR
254 Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. item_code_254 EA Excess(+) Full Conversion INR
255 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping item_code_255
256 ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping item_code_256 M- Excess(+) Full Conversion INR
257 iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping item_code_257 M- Excess(+) Full Conversion INR
258 iii) S/L Threaded A/G HD MS Pipes of 50 mm dia with fittings,Painting item_code_258 M- 488.73 Excess(+) Full Conversion INR
259 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. item_code_259 M2 153.952 Excess(+) Full Conversion INR
260 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete item_code_260 M2 170.944 Excess(+) Full Conversion INR
261 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: item_code_261 KG Excess(+) Full Conversion INR
262 Providing and fixing of square composite (FRP) Manhole Cover with frame D400 with 40T load bearing capacity, all complete and as per drawing, specification and direction of Engineer-in-charge. Note: Diameter would be clear opening of cover. item_code_262
263 iii) 900 X 900 mm item_code_263 EA 136020.96 Excess(+) Full Conversion INR
264 Providing and fixing of lifting handle foot lever for use with flat sealed cover and trench panels of OPW Fiberlite or equivalent make make as per specification and direction of Engineer in charge. item_code_264 EA 17317.36 Excess(+) Full Conversion INR
265 CONSTRUCTION OF PUMP ISLAND & DU INSTALLATION item_code_265
266 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) item_code_266
267 xi) MPD/MPP pumps upto 2 nos., 0-30 Km item_code_267 LS Excess(+) Full Conversion INR
268 xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km item_code_268 KM Excess(+) Full Conversion INR
269 vii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km item_code_269 LS Excess(+) Full Conversion INR
270 viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km item_code_270 KM Excess(+) Full Conversion INR
271 Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump item_code_271
272 i) 2 product - 4 nozzle MPPs/MPDs item_code_272 EA Excess(+) Full Conversion INR
273 Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge item_code_273 EA Excess(+) Full Conversion INR
274 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_274
275 i) All kinds of Soil item_code_275 M3 Excess(+) Full Conversion INR
276 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. item_code_276
277 i) Local Fine Sand within grading zone IV item_code_277 M3 Excess(+) Full Conversion INR
278 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_278 M2 Excess(+) Full Conversion INR
279 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: item_code_279
280 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) item_code_280 M3 Excess(+) Full Conversion INR
281 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) item_code_281 M3 Excess(+) Full Conversion INR
282 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_282
283 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_283 M2 Excess(+) Full Conversion INR
284 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth item_code_284
285 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH item_code_285 M3 Excess(+) Full Conversion INR
286 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH item_code_286 M2 Excess(+) Full Conversion INR
287 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. item_code_287
288 iv) Granite of any colour and shade having Area of slab over 0.50 sqm item_code_288 M2 Excess(+) Full Conversion INR
289 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. item_code_289 M2 Excess(+) Full Conversion INR
290 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_290
291 iii) 3 Core x 1.5 sq. mm. (copper) item_code_291 M- Excess(+) Full Conversion INR
292 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS item_code_292 M- Excess(+) Full Conversion INR
293 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. item_code_293
294 vi) 3 Core x 1.5 sq. mm. item_code_294 EA Excess(+) Full Conversion INR
295 vii) 3 Core x 2.5 sq. mm item_code_295 EA Excess(+) Full Conversion INR
296 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make item_code_296
297 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire item_code_297 M- Excess(+) Full Conversion INR
298 CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA ratings. item_code_298
299 iii) 500VA CVT item_code_299 EA Excess(+) Full Conversion INR
300 iv) 5KVA stabilizer item_code_300 EA Excess(+) Full Conversion INR
301 PROVIDING INTERNAL WIRING item_code_301
302 ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. item_code_302 EA Excess(+) Full Conversion INR
303 Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long item_code_303 EA Excess(+) Full Conversion INR
304 Supply and Installation of 16 SWG MS/GI powder coated weather proof Earthing Box of following size with door and locking arrangement with lock and key. Box to be mounted on ISA 40x40x5 (Painted with black synthetic enamel paint) frame having 2 legs of length 800 mm (500 mm above ground and 300 mm below ground which is to be grouted with PCC 1:2:4). Bottom of box should have opening for incoming earth GI strips all complete, as per specification and direction of Engineer-in-charge. Note: EARTHING BOX in RED should be boldly written over the box. The box should have a hood at the top extending outwards such that no water should seep through inside the box during rainy season to avoid rusting. item_code_304
305 i) 50 x 10mm G.I. Strip item_code_305 M- Excess(+) Full Conversion INR
306 ii) 32 x 6 mm G.I.strip item_code_306 M- Excess(+) Full Conversion INR
307 v) 25 x 3 mm GI strip item_code_307 M- Excess(+) Full Conversion INR
308 PROVISION OF ELECTRIC PANEL & ALLIED ELECTRICAL WORKS item_code_308
309 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. item_code_309
310 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. item_code_310 EA 209147.12 Excess(+) Full Conversion INR
311 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_311
312 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS item_code_312 M- Excess(+) Full Conversion INR
313 PROVIDING INTERNAL WIRING item_code_313
314 i) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. item_code_314 EA Excess(+) Full Conversion INR
315 Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete. item_code_315
316 i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. item_code_316 M- 18.112 Excess(+) Full Conversion INR
317 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make item_code_317
318 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire item_code_318 M- Excess(+) Full Conversion INR
319 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire item_code_319 M- Excess(+) Full Conversion INR
320 iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire item_code_320 M- Excess(+) Full Conversion INR
321 iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire item_code_321 M- Excess(+) Full Conversion INR
322 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. item_code_322
323 iii) 4 module frame item_code_323 EA Excess(+) Full Conversion INR
324 viii) 15 A Modular switch item_code_324 EA Excess(+) Full Conversion INR
325 xii) Fan Regulator of stepped modular type item_code_325 EA Excess(+) Full Conversion INR
326 Supply and Installation of Flame Proof ESD Push Button item_code_326 EA Excess(+) Full Conversion INR
327 CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: item_code_327
328 iii) 1200 mm sweep item_code_328 EA Excess(+) Full Conversion INR
329 EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). item_code_329
330 ii) 9" dia light duty, make Khaitan or equivalent item_code_330 EA Excess(+) Full Conversion INR
331 Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: item_code_331
332 iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works item_code_332 EA Excess(+) Full Conversion INR
333 Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) item_code_333 EA Excess(+) Full Conversion INR
334 Supplying and fixing of MV Lightining Arrestor horn gap type as required item_code_334 EA Excess(+) Full Conversion INR
335 Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) item_code_335 EA Excess(+) Full Conversion INR
336 Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc item_code_336
337 i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. item_code_337 M2 Excess(+) Full Conversion INR
338 iv) 11 KV grade hand gloves, ISI mark item_code_338 EA Excess(+) Full Conversion INR
339 Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip) item_code_339 EA 3389.656 Excess(+) Full Conversion INR
340 SUPPLY AND INSTALLATION OF YARD LIGHTS item_code_340
341 Supply & laying of Heavy Duty type, High compression strength, IP 67 rated (DWC) Double wall corrugated HDPE Conduits as per IS:14930/ IS:16205. Laying includes with GI pull wires inside the conduits & necessary ends to be filled with sealants, of all complete and as per drawing & specification. item_code_341
342 ii) 63 mm OD / 50 mm ID item_code_342 M- Excess(+) Full Conversion INR
343 Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil item_code_343
344 iv) Pipes, Cable etc. > 80mm < 300m dia item_code_344 M- Excess(+) Full Conversion INR
345 Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 item_code_345 EA Excess(+) Full Conversion INR
346 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_346
347 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS item_code_347 M- Excess(+) Full Conversion INR
348 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS item_code_348 M- Excess(+) Full Conversion INR
349 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. item_code_349
350 vii) 3 Core x 2.5 sq. mm item_code_350 EA Excess(+) Full Conversion INR
351 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : item_code_351
352 v) 25 x 3 mm GI strip item_code_352 M- Excess(+) Full Conversion INR
353 OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : item_code_353
354 ii) S/E of 9 Meter high galvanised Octagonal pole with top 90mm(A/F), bottom 158mm (A/F), made up of 3mm thick plate having a base plate of size 285 x 285 x 16 with double arm 1500mm long bracket arm made up of 48 O.D. pipe with EN grade galvanised foundation bolts & anchor plate on suitable concrete foundation as per standard drawings enclosed herein (Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. Of 250W Metal halide luminaries (on opposite sides) item_code_354 EA Excess(+) Full Conversion INR
355 i) S/E of 7 Meter high galvanised Octagonal pole with top 70mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 220 x 220 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) item_code_355 EA Excess(+) Full Conversion INR
356 Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. item_code_356
357 ii) S/E Arm " Y " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge item_code_357 EA Excess(+) Full Conversion INR
358 Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. item_code_358
359 i) "Y" Pole item_code_359 EA Excess(+) Full Conversion INR
360 ii) "L" Pole item_code_360 EA Excess(+) Full Conversion INR
361 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. item_code_361 EA Excess(+) Full Conversion INR
362 i) All kinds of Soil item_code_362 M3 Excess(+) Full Conversion INR
363 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth item_code_363 M2 Excess(+) Full Conversion INR
364 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_364
365 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm item_code_365 M3 Excess(+) Full Conversion INR
366 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_366
367 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_367 M2 Excess(+) Full Conversion INR
368 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_368
369 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_369 KG Excess(+) Full Conversion INR
370 STANDARD DISPLAY BOARD-EGRESS SIDE item_code_370
371 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_371
372 i) All kinds of Soil item_code_372 M3 Excess(+) Full Conversion INR
373 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m item_code_373 M3 190.88 Excess(+) Full Conversion INR
374 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying & curing, excluding the cost of centering, shuttering finishing including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge, ALL WORKS UPTO PLINTH LEVEL. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable. item_code_374
375 i) M-15 grade plain cement concrete (cement content considered @ 240 kg/cum item_code_375 M3 Excess(+) Full Conversion INR
376 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_376
377 i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm item_code_377 M3 7936.12 Excess(+) Full Conversion INR
378 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_378
379 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_379 M2 Excess(+) Full Conversion INR
380 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_380
381 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_381 KG Excess(+) Full Conversion INR
382 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : item_code_382
383 i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate item_code_383 EA 41.32 Excess(+) Full Conversion INR
384 Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. item_code_384
385 i) Hot finished welded type tubes item_code_385 KG Excess(+) Full Conversion INR
386 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. item_code_386
387 ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) item_code_387 KG Excess(+) Full Conversion INR
388 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. item_code_388 M2 Excess(+) Full Conversion INR
389 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_389
390 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS item_code_390 M- Excess(+) Full Conversion INR
391 Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil item_code_391
392 i) Pipes,cables etc. not exceeding 80mm dia item_code_392 M- Excess(+) Full Conversion INR
393 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. item_code_393
394 vii) 3 Core x 2.5 sq. mm item_code_394 EA Excess(+) Full Conversion INR
395 Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. item_code_395
396 i) for 2.5 sq.mm. cable entry size with 9 terminals item_code_396 EA Excess(+) Full Conversion INR
397 Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs item_code_397
398 ii) 2+8 way SPN item_code_398 EA Excess(+) Full Conversion INR
399 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. item_code_399
400 ii) Upto 32A DP MCB item_code_400 EA 503.36 Excess(+) Full Conversion INR
401 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. item_code_401 EA Excess(+) Full Conversion INR
402 STANDARD DISPLAY BOARD-INGRESS SIDE item_code_402
403 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 item_code_403
404 i) All kinds of Soil item_code_404 M3 Excess(+) Full Conversion INR
405 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m item_code_405 M3 Excess(+) Full Conversion INR
406 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying & curing, excluding the cost of centering, shuttering finishing including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge, ALL WORKS UPTO PLINTH LEVEL. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable. item_code_406
407 i) M-15 grade plain cement concrete (cement content considered @ 240 kg/cum item_code_407 M3 Excess(+) Full Conversion INR
408 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level item_code_408
409 i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm item_code_409 M3 Excess(+) Full Conversion INR
410 Centering and shuttering including strutting, propping etc. and removal of form for : item_code_410
411 i) Foundations,footings,bases of columns, etc. for mass concrete item_code_411 M2 Excess(+) Full Conversion INR
412 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels item_code_412
413 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 item_code_413 KG Excess(+) Full Conversion INR
414 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : item_code_414
415 i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate item_code_415 EA Excess(+) Full Conversion INR
416 Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. item_code_416
417 i) Hot finished welded type tubes item_code_417 KG Excess(+) Full Conversion INR
418 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. item_code_418
419 ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) item_code_419 KG Excess(+) Full Conversion INR
420 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. item_code_420 M2 Excess(+) Full Conversion INR
421 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items item_code_421
422 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS item_code_422 M- Excess(+) Full Conversion INR
423 Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil item_code_423
424 i) Pipes,cables etc. not exceeding 80mm dia item_code_424 M- Excess(+) Full Conversion INR
425 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. item_code_425
426 vii) 3 Core x 2.5 sq. mm item_code_426 EA Excess(+) Full Conversion INR
427 Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. item_code_427
428 i) for 2.5 sq.mm. cable entry size with 9 terminals item_code_428 EA Excess(+) Full Conversion INR
429 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. item_code_429
430 ii) Upto 32A DP MCB item_code_430 EA Excess(+) Full Conversion INR
431 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. item_code_431 EA Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_199521.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
TECHBIDPT83.pdf
Tender Documents • 1.03 MB
TechnicalSpecifications_Listofpreferredmakes_QAP.rar
Tender Documents • 18.81 MB
DRAWINGS.rar
Tender Documents • 2.55 MB
GCC_PPE_ISB_GDODOSOR_SAFETY_HOLIDAY_OTHERS.rar
Tender Documents • 13.43 MB
PartBlatest.pdf
Tender Documents • 1.71 MB
STATEMENT_OF_CREDENTIALS_PT83.xls
Tender Documents • 0.04 MB
BOQ_199521.xls
BOQ • 0.95 MB
Download all tender documents and submit your bid