Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.6 L+₹4,447.30 (0.59%)Rejected-Finance 308 MANDI ROAD BARWALA 125121 | HISAR | HARYANA | 125121 | L2 | Rejected-Finance Higher rate to the Contractor | |
| 3 | Rejected-Technical | - | Rejected-Technical Not responsive |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
17 Jan 2022, 5:00 pmClosed
Executive Engineer (M)
CCS HAU, Hisar
Repair/renovation of Central Lab No. 47 (Ist floor) for the Department of EECM in the premises of College of Home Science at CCS HAU, Hisar. (including EI work)
2022_HRY_202526_1
3263-C
Open Tender
Civil Works
Works
90 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹14,000
Yes
15 Apr 2022
3 Jan 2022
18 Jan 2022
4 Jan 2022
17 Jan 2022
4 Jan 2022
Amount
Civil work 1 to 22:- Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar (HSR 5.7.4)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge (HSR 5.25)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diaMeters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D kg or more. (HSR 6.33.6)
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)
Providing and fixing ceramic & Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. (HSR 10.73)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (HSR 11.68.3)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood 35 mm thick (HSR 12.10.1.1)
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (HSR 12.36.1)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (HSR 12.50.1)
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (HSR 12.98.2 )
Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (HSR 13.7.1)
Providing and fixing factory made ISi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (HSR 13.8.1 )
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes (HSR 13.10.1)
Providing and fixing wooden box to cover existing conduit pipes consisting of 19 mm thick commercial type block board of approved make (ISI mark) finished with 1 mm thick laminated sheet (ISI mark) of approved make, shade & colour including cutting, nails, screws, gutters, fevicols etc. complete in all respect as directed by Engineering-In-Charge. (NS)
Manufacturing and supplying conference table of elliptical shape having 2'-0" width and 2'-6" height consisting of following:- (a) FRAME WORK:- Consisting of 25 mm x 25 mm M.S. tube (14 gauge) as per architectural drawing. (b) TOP PORTION (2’-0” WIDE):- Consisting of 25 mm thick commercial type block board (ISI mark) of approved make finished with 1 mm thick plastic laminated sheet (ISI mark) of approved make, shade and colour. (c) PANELLING/VERTICAL PORTION (for inner surface):- 1’-11½” high wooden paneling consisting of 0’-4" wide and 0’- ¾" thick strips of teak wood having3/8" wide groove over 6 mm thick commercial plywood approved make fixed on teak wood battens of size 25 mm x 25 mm & steel frame and 4 mm thick commercial plywood on back side to cover frame. (d) MS angle iron of size 25 mm x 25 mm x 5 mm welded with MS tube legs to fix the wooden strips (one at top and one at bottom). (e) Beading:- Teak wood beading of size 0'-¾" 0'-1" at upper edge and 0'-2½" x 0'-1 1/4" (5/4") at bottom of top surface of required shape on both edges of table (outer and inner edges). Including cutting, welding, primer and painting on MS tube frame work , spirit polishing, nails, screws, nuts & bolts, fevicol, brass adjustor etc., complete in all respects as per drawing and design. (NS)
Removing of existing damaged PVC flooring and cleaning the surface/floor, complete in all respect as directed by Engineer-In-Charge. (NS)
Electrical work 23 to 30:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)
SITC iof push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to complete the job upto entire satisfaction of Engineer-in-charge. (NS)
Providing and installation of automatic voltage stablizer of Single Phase 5.00KVA capacity copper wound heavy duty 100volt up of V -guard make ISI marked complete in all respect. (NS )
Providing and fixing in position powder coated MS stands for outdoor units including suitable nuts & bolts etc. of best quality complete in all respect. (NS)
Providing and fixing extra copper tubing / referigerant pipe for above split air conditioners consisting of inlet , outlet pipes , insulation and electricwiring etc as per requirement complete in all respect beyond 4.0 meters length (NS)
Providing and installing split type air conditioners fIVE star rating inverter type with copper coil 2.0 ton capacity +/-10% fitted with super tropical - DC PAM inverter - return cooled - rotary compressor operating on referigerant R-32 suitable for wall mounting confirming to IS : 1391 ( Part - 2 ) / 92 ( Execpt power consumption norms with upto date amendments suitable for operating on 230 volts 50Hz single phase A.C supply having following specifications :- i) Cooling Coil row - 3 Nos. ii) Air Flow ( CMH ) - 1000-1400 cum / hr iii) Sound Level ( H/M/L ) - 45/38/26 iv) Louvers Swing - 3D+3D Auto etc. complete in all respect. Make O General / Mitsubishi ( Heavy Industries ) Five Star Rating Model as approved by the Engineer in Charge. (NS)
P& F UPVC pipes of 25mm various sizes for disposal of condensed water drainage from indoor unit to nearest disposal point in toilet / outside as per direction of the EIC complete in all respect. (NS) Make Supreme / Prince / Finolex
VINOD KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .