EXECUTIVE ENGINEER EP
Office of PCE E BSNL MH Electrical Zone Ground Floor A Wing Santacruz Mumba
Providing Service connection cable Energy meter earthing for BSNL Mobile tower at KRCL VERNA Goa
2026_BSNL_270504_1
1300/CEEM/2025-26/NIT/72
Open Tender
Electrical Works
Item Rate
30 days
BSNL VERNA GOA
Please refer Tender Document
2 documents required · 2 mandatory
₹590
Yes
BSNL
₹3,099
Yes
11 Mar 2026
11 Mar 2026
2 Apr 2026
11 Mar 2026
1 Apr 2026
11 Mar 2026
Supplying of following sizes of PVC insulated & PVC sheathed /XLPE steel armoured aluminium conductor power cable of 1.1KV grade etc complete as reqd.
4 x 16 Sq. mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple pole
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Connection with Copper link, with Single Core FRLS Copper PVC Insulated Flexible Cable for voltage grade upto 1100V with copper lug on both end having length approx 0.5 mtr. of 10 Sq.mm size including testing commisioning etc. as required.
Providing and fixing of 63 Amp capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing of MS Wall bracket made up of 25x3 mm MS angle on all support and on top UPVC Roofing sheet of 1 sq.mtrs i/c s/d necessary hexagonal sheet screws etc on all peripheri of the MS angle str. for protection against Rain water for outdoor type GED energy meter complete as reqd.(App 25mmx3mm MS Angle in Kg =1.12kg /mtrs x5.2 mtrs ic 5.8 kg for 01 job and 1sq.mtr UVC Sheet 01nos reqd.))
Supplying and fixing of MS structure with suitable size angle to take weight of Outdoor type Meter box, Meter, MCB cable termination etc. with 35X35X5 mm MS angle structure for fixing of outdoor type i.c. fabrication for cutting, drilling, welding and primer paint, grouting in ground with suitable quantity of PCC mixture to give fixed support to MS structure in muddy soil etc. complete as required.
Supplying and fixing of powder coated type out door meter box with double door complete with Glass for ease of reading the meter readings, sealing arrangements, 22 SWG, suitable for MCCB or MCB type switchgear as MAINS Isolation switch as well as arrangment for fixing for GED meter complete etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying of 40mm dia medium class G.I. pipe in ground complete with G.I. fittings incl trenching and refilling etc as reqd
Providing and laying 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching and re-filling etc as required
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
nitverna.pdf
Tender Documents • 1.43 MB
BOQ_315383.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .