Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹33.0 L+₹63,675.31 (1.97%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹33.1 L+₹75,384.01 (2.33%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹68,100
Closing Date
30 Sept 2022, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
SPECIAL REPAIRS TO BLDG NO 7E OF FEL AT MCEME PROVN OF REFURBISHING MAIN ENTRANCE GATE AT CTW MCEME AND PROVN OF RAISING OF ENTRANCE PORCH FLOOR LEVEL AND OTHER CONNECTED ITEMS AT SDD UNDER GE MCEME SECUNDERABAD
2022_MES_549467_1
GE/MCEME/TOK/38 OF 22-23
Open Tender
Civil Works
Item Rate
180 days
GE MCEME SECUNDERABAD
Class D Category a(I)
9 documents required · 9 mandatory
₹500
GE MCEME SECUNDERABAD
₹68,100
Yes
19 Oct 2022
2 Sept 2022
3 Oct 2022
2 Sept 2022
30 Sept 2022
16 Sept 2022
Amount
Dismantling Single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed by Engineer in Charge.
Dismantling structural steel work including doors, gates,etc complete all as specified and directed by Engineer in Charge.
Demolition of old cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer in Charge.
Material and Labour for 100mm thick cement concrete type B-1 1:2:4(using 20mm graded stone aggregate) to flooring complete all as specified and directed by Engineer in Charge.
M & L pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering / cladding to wall ,fixed with self tapping screw complete all as specified and directed by Engineer in Charge.
Dismantling Battens for tiles, shingles etc, of any size including tilting fillets spaced Exc 15 cm complete all as specified and directed by Engineer in Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed by Engineer in Charge.
M&L Second class hard-wood in scantlings, clean sawn and fixed as in purlins, rafters etc, unframed work complete all as specified and directed by Engineer in Charge.
M & L pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutters, fixed with self tapping screw complete all as specified and directed by Engineer in Charge.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins here connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates quality conforming to Fe 410W(Gde-250) complete all as specified and directed by Engineer in Charge.
M&L for preparing surfaces of new wood and wood based materials, of any description and girth, not otherwise described, over 10 cm width or girth with two coats of of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer in Charge.
Demolition of old brick work of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer in Charge.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed by Engineer in Charge.
M&l for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in coping including necessary form work and finishing exposed concrete surfaces fair and even and weathering, slightly rounded or chamfered angle and throating complete all as specified and directed.
Taking down plastering in cement mortar on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. complete all as specified and directed by Engineer in Charge.
M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick on fair faces of brick work in CM 1:4 finished even and smooth with using water proofing compound @3% without using extra cementcomplete all as specified and directed by Engineer in Charge. (Note : WPC will be measured separately)
Supplying only Integral waterproofing compound complete all as specified and directed by Engineer in Charge.
M&L for applying two coats of OBD over a coat of primer over two coats of wall care putty including preparing the new plastered wall surfaces complete all as directed by Engr-in-charge
M&L for complete removal of existing treatment from surfaces and applying two coats of oil bound distemper over a coat of alkali resisitant primer and one coat wall care putty complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic mulsion paint ( asian paint ultima protek or equivalent) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including preparing the new plastered wall surfaces complete all as directed by Enginneer-In-Charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic mulsion paint ( asian paint ultima protek or equivalent) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including complete removal of existing treatment of the old plastered wall surfaces complete all as directed by Enginneer-In-Charge.
M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for two coats of synthetic enamel paint over a coat of red oxied primer including preparation of new steel surface of any description over 10 cm width and girth complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:3:6) type C2 using 40 mm graded aggregate as in plinth protection/ Paths of 100mm thick. Finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
S&F plain sheet glass ordinary quality and glazing with oil putty /wdn beads in square n.exc.0.50sqm in each pane 3 mm thick plain glass including hacking out old complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out in hard/ dense soil complete all as specified and directed by Engineer in Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard / dense soil complete all as specified and directed by Engineer in Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point in soils complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete Type D-2 1:4:8 (Using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer in Charge.
M&L Reinforced cement concrete (design Mix) M-25 (20 mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer in Charge.
M&L Reinforced cement concrete (design Mix) M-25 (20 mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer in Charge.
M&L Reinforced cement concrete (design Mix) M-25 (20 mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer in Charge.
M&L Reinforced cement concrete (design Mix) M-25 (20 mm graded aggregate) on Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer in Charge.
S&F mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer in Charge.
S&F mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer in Charge.
M&L for formwork to sides of rough finished flat surface of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer in Charge.
M&L for formwork to sides of rough finished flat surface of concrete pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer in Charge.
M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer in Charge.
M&L for use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer in Charge.
M&L for formwork to sides and soffits of rough finished flat surface of concrete of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer in Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically procided for renewal including removal of demolished material beyond the Military land to a distance exceeding mtr not exceeding KM complete all as specified and directed by Engineer in Charge.
M&L Hardcore guage n.exc 63 mm ,deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled / rammed to a true surface.Brocken stone or Boulders 100 mm thick complete all as specified and directed by Engineer in Charge.
M&L PCC sub base 1:4:8 type D-2 in paving 75 mm thick complete all as specified and directed by Engineer in Charge.
M&L cement concrete type B1 1:2:4 (20mm graded aggregate) 25mm thick in floor complete all as specified and directed by Engineer in Charge.
M&L Brick work with fly ash modular bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer in Charge.
M&L for Rendering 10 mm thick cement plaster on fair faces of brick work/concrete in cement mortar 1:4, with water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer in Charge.
M&L Granite 18 to 20 mm thick (of any type) work (table rubbed and polished) for wall lining (wall Clading) over and including 12mm thick cement mortar in (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plaster surface of wall and applying two coats of cement base paint over and including a coat of primer complete all as specified and directed
M&L Framed work such as grills gratings etc with ends of bars shouldered and / or rebated, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe 290 / Gde-E/165, for portions framed and hung as gates, , stops, hand made sliding bolts etc and for ornamental and intricate design complete all as specified and directed by Engineer in Charge.
M&L preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on surfaces over 10 cm in width or girth not other wise described complete all as specified and directed by Engineer in Charge.
M&L preparation of old steel surfaces and applying one coat of synthetic enamel paint on steel surfaces over 10 cm in width or girth not other wise described complete all as specified and directed by Engineer in Charge.
S&F Stainless Steel Grade 304 of 16 gauge steel letters of size 650x300mm all as specified and directed complete all as specified and directed by Engineer in Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed by Engineer in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing srviceable tiles to store and rubbish off the premises, complete all as specificed and directed by Engineer-in-Charge.
M&L for 100 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specificed and directed by Engineer-in-Charge.
M&L for 50 mm sand filling under floors or in foundations including watering and consolidation spread, rolled and consolidated to gradient and camber required, complete all as specificed and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment, complete all as specificed and directed by Engineer-in-Charge.
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) in floor finished fair and smooth using extra cement complete all as specificed and directed by Engineer-in-Charge.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes, complete all as specificed and directed by Engineer-in-Charge.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments, complete all as specificed and directed by Engineer-in-Charge.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed by Engineer in Charge.
Material and labour for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit concealed wiring including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point / wal mounted fan point controlled by one, one way switch 5 amps, SP complete all as specified and directed by Engineer in Charge. Note:Cutting Chasing will be measured and paid seperately
All as per item No. 64 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 64 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed by Engineer in Charge.
All as per item No. 64 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board complete all as specified and directed by Engineer in Charge.
Supply and fixing of Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified and directed by Engineer in Charge.
Supply and fixing of socket outlet 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer in Charge.
Supply and fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer in Charge.
Supply and fixing switch socket combination 2 in 1 multipurpose 3 pin 5/15 amps flush type complete all as specified and directed by Engineer in Charge.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts complete all as specified and directed by Engineer in Charge.
Supply and fix sheet metal enclosure with double pole and Earth Metal Plug & Socket including 20A DP MCB complete all as specified and directed by Engineer in Charge. .
Supply and fix sheet metal enclosure with triple pole and Earth Metal Plug & Socket including 32A TP MCB complete all as specified and directed by Engineer in Charge.
Material and labour for concealed Submain wiring with 2 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing & removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From TPN DB to SPN DB and For single phase Industrial sockets) complete all as specified and directed by Engineer in Charge. Note:- Cutting and chasing will be measured and paid seperately.
Material and labour for concealed Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including 2 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-FOUR runs of cable, TWO run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From MCCB DB to TPN DB) complete all as specified and directed by Engineer in Charge. Note:- Cutting and chasing will be measured and paid seperately.
Material and labour for concealed Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing and removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-FOUR runs of cable, TWO run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (For 3 phase Industrial sockets) Note:- Cutting and chasing will be measured and paid seperately.
Material and labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good all as specified and as directed
Supply and fixing LED lights fitting 4ft 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fix LED energy efficient building security light fitting of capacity of 40 W for fixing in GI pipe bracket on wall complete all as specified and directed by Engineer in Charge. NOTE : GI bracket, clamp, nut and bolt etc will be measured in separate item.
Supply & fixing galvanised iron tube bracket of 40 mm dia light grade and 1.2 mtr length for fixing building security light, with all fixing arrangement including necesssary clamp, nut and bolt etc. as required size complete all as specified and directed by Engineer in Charge.
Supply and fixing LED mid bay light fitting of 60 W with PDC housing suspended from ceiling/ wooden tress with and including suspending chain or hook ,3 core copper flexible wire from ceiling rose to light fitting, nuts and bolts complete all as specified and directed by Engineer in Charge.
M&L for making of MS flat ring including welding, making hook, nuts and bolts for hanging mid way lights complete all as specified and directed by Engineer in Charge.
S&F , Wall mounted fan industrial type, single phase, 240 V, 450 mm sweep, 50 Hz, 1400 rpm, metal body with metal blades wall mounted fan, connected with 3 core 1.5 sq mm copper conductor cable from ceiling rose/socket to exhaust fan all as specified and as directed.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 70 Sqmm , 3.5 core complete all as specified and directed by Engineer in Charge.
Excavation in trenches not exceeding 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard /dense soil for laying / repairing of LT cable / GI pipe complete all as specified and directed by Engineer in Charge.
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid.
Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and directed by Engineer in Charge.
Supply and fixing medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and directed by Engineer in Charge.
Change over switch Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete all as specified and directed by Engineer in Charge.
S & F Vertical type MCCB TPN DB 4 way double door suitable for 200A MCCB made out of CRCA sheet housing with powder coating with min 300 A busbar rating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 200 amps suitable for Vertical MCCB DB complete all as specified and directed by Engineer in Charge.
Supply and replace MCB double door DB TPN 4 way with 200 Amps busbar complete all as specified and directed by Engineer in Charge.
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar complete all as specified and directed by Engineer in Charge.
Supply and fix in repair MCB TP 63 Amps 415 volts for fixing on MCB DB complete all as specified and directed by Engineer in Charge.
Supply and fix in repair MCB TPN 63 Amps 415 volts for fixing on MCB DB complete all as specified and directed by Engineer in Charge.
Supply and fix in repair MCB TP 40 Amps 415 volts for fixing on MCB DB complete all as specified and directed by Engineer in Charge.
Supply and fix in repair MCB SPN 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer in Charge.
Supply and fix in repair MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer in Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement including testing all as specified and directed by Engr-In-Charge. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.) complete all as specified and directed by Engineer in Charge.
SAI RUPA CONSTRUCTIONS
K LAKSHMAN SINGH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .