| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Following Repairing and maintenance works are to be carried out of permanent 33/11KV S/S which is feeding supply in Mela area during Magh Mela 2026-27. | |||||
| 1.01 | Overhaulling and maintenance 11kv breakers & 33 kv control pannel cleaning, oiling, greasing & cheking of trippings system with all required materials like triping/closing coil,on/off Lever ,limit switch ,Plunger and switches.(all required material provided by the contractor). | 30 | Job | - | - |
| 1.02 | Supply, Replacement and installation of damage 11 kv CT & Supply of Spare ct is also required for emergency (ratio 800/400/5 A Schneider make) for 11 kv incoming vcb pannel.(all required materials like CT etc provided by contractor) | 15 | Job | - | - |
| 1.03 | Supply , Replacement and installation of damage 11 kv CT & Supply of Spare ct is also required for emergency (ratio 400/200/5 A Schneider make) for 11 kv outgoing vcb pannel.(all required materials like CT etc provided by contractor) | 20 | Job | - | - |
| 1.04 | Supply ,Replacement and installation of damage 11 kv protection Relay of 11 kv Outgoing , Incoming & 33 kv control pannel & Supply of Spare relay is also required for emergency .(all required material like protection relay etc provided by contractor) | 10 | Job | - | - |
| 1.05 | Supply , Replacement and installation of damage 11 kv CT Side Spout & Supply of Spare CT Side Spout is also required for emergency ( Schneider make or as per requirement as per site ) for 11 kv vcb pannel.(all required materials like CT etc provided by contractor) | 10 | Job | - | - |
| 1.06 | Supply , Replacement and installation of damage 11 kv busbar Side Spout & Supply of Spare CT Side Spout is also required for emergency ( Schneider make or as per requirement as per site ) for 11 kv vcb pannel.(all required materials like CT etc provided by contractor) | 10 | Job | - | - |
| 1.07 | Supply , Replacement and installation of damage 11 kv circuit breaker charging motor & Supply of Spare charging motor is also required for emergency ( Schneider make vcb or as per requirement as per site ) for 11 kv vcb pannel.(all required materials like CT etc provided by contractor) | 10 | Job | - | - |
| 1.08 | Replacement and installation of damage 11 kv Vacuum interrupter & Supply of Spare vaccum interrupter is also required for emergency (Schneider make vcb & stelmake as per instruction of je/sdo ) for 11 kv incoming/outgoing vcb pannel.(all required materials like Vacuum interrupter etc provided by contractor) | 15 | Job | - | - |
| 2Following works are to be carried out for 11 KV line of differents 33/11 kv substation for feeding electricity supply to Magh mela area 2026-27. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
T-No-51 VCB, RMU Repair.docx
Tender Documents • 0.14 MB
BOQ_2230270.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .