Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹1.1 Cr | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER |
| 2 | L2₹1.3 Cr+₹15.1 L (13.7%)Rejected-Finance MANEGAON CHAMPANAGAR KHAMARIA JABALPUR 482005 MP | JABALPUR | JABALPUR | MP | 482005 | ₹1.3 Cr+₹15.1 L (13.7%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.3 Cr+₹24.0 L (21.7%)Rejected-Finance | ₹1.3 Cr+₹24.0 L (21.7%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | ASHOKA ASSOCIATES L2 | New Era Engineers L1 | PARAS BROTHERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | S & F in replacement Heavy duty chemical dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 Kg/cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with Stainless Steel sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV. Three phase panel DOL starter for Dosing Pump made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, high voltage / low voltage protection.complete all as specified and directed. | 32 | Each | 1,50,000 ₹48,00,000 | 1,45,000 ₹46,40,000 Lowest | 1,51,000 ₹48,32,000 |
| 2.00 | S & F, in repair, Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc of size 15 mm bore, complete all as specified and directed. | 120 | RM | 150 ₹18,000 | 50 ₹6,000 Lowest | 120 ₹14,400 |
| 3.00 | Taking down existing sub main wiring with aluminium conductor cable of any size with GI earth wire on and including wooden batten and removing materials from the site complete all as specified and as directed. | 80 | RM | 20 ₹1,600 | 5 ₹400 Lowest | 5 ₹400 Lowest |
| 4.00 | M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25 mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 80 | RM | 225 ₹18,000 | 225 ₹18,000 | 200 ₹16,000 Lowest |
| 5.00 | Taking out existing unserviceable XLPE cables, any type and any size, from its existing location complete all as specified and directed.
( Note : Excavation and earthwork wherever required shall be measured and paid for separately against relevant items of this BoQ.) | 300 | RM | 20 ₹6,000 | 10 ₹3,000 Lowest | 25 ₹7,500 |
| 6.00 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 185 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc complete all as specified and directed.
(Note:- Excavation and earth work, sand cushioning, cable protection covers, cable protection pipe wherever required shall be measured and paid for separately under respective items in this BOQ.) | 100 | RM | 1,650 ₹1,65,000 | 1,150 ₹1,15,000 | 600 ₹60,000 Lowest |
| 7.00 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 50 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc complete all as specified and directed.
(Note:- Excavation and earth work, sand cushioning, cable protection covers, cable protection pipe wherever required shall be measured and paid for separately under respective items in this BOQ.) | 200 | RM | 490 ₹98,000 | 360 ₹72,000 Lowest | 450 ₹90,000 |
| 8.00 | Supply, install, testing and commissioning, in repleacement, LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodate the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted in PCC (1:2:4) type B1(using 20mm graded crushed stone aggregate) as foundation block with suitable mounting arrangement for bus bars, voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 700Amp electrical grade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved, type tested, internal wiring all including the following incoming complete all as specified and directed:-
Note:- Connection from Main bus bar to Outgoing MCCB shall be provided through bus bar of suitable rating instead of copper wires | 1 | Each | 6,25,000 ₹6,25,000 | 5,60,000 ₹5,60,000 Lowest | 8,00,000 ₹8,00,000 |
| 8.01(a) MCCB 4P 630 Amps rating, 50 Hz, 415 V with rupturing capacity 50 KA, adjustable (b) MCCB 4P 125 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 04 Nos (outgoing) (c) MCCB 4P 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 03 Nos (outgoing) (d) MCB TPN 20 Amps rating, C Curve, 415 V with rupturing capacity 10 KA - 02 Nos (outgoing) (e) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing) (f) On load change over switch, 4 Pole, 500 Amps, 415 Volts - 01 No (g) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 06 Nos (h) Fully automatic Motor Starter (Star-Delta) suitable for 60 HP centrifugal Pump set, 3 Phase - 04 Nos (j) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP submersible Pump set, 3 Phase - 02 Nos (k) Single phase preventer, over load relays of suitable rating - 06 Nos (l) Voltmeter 0-500 V digital type with selector switch - 1 No (m) Indicator lamp LED type - 3 Nos (R, Y & B) (n) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 700/5 A - 01 No | ||||||
| 9.00 | Supply, install, testing and commissioning in repleacement, LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodate the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 1300Amp electrical grade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved, type tested, internal wiring all including the following incoming complete all as specified and directed:-
Note:- Connection from Main bus bar to Outgoing MCCB shall be provided through bus bar of suitable rating instead of copper wires | 1 | Each | 9,83,000 ₹9,83,000 Lowest | 11,25,000 ₹11,25,000 | 14,00,000 ₹14,00,000 |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
28 Jun 2025, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPT SADAR 482001
Special repair/replacement of old unserviceable submersible, centrifugal pump, column pipe and allied works against BER LT Panel and BP Dozer and connected items for pump houses under GE (W) Jabalpur
2025_MES_710041_1
81108/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
CWE JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (WEST ) JABALPUR
₹2.1 L
Yes
18 Oct 2025
24 May 2025
5 Jul 2025
24 May 2025
28 Jun 2025
14 Jun 2025
24 May 2025 - 8 Jun 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .