Executive Engineer, Abohar Canal Ground Water Divi
Executive Engineer, Abohar Canal Ground Water Divi
Estimate for Remodeling/Relining of Pakkan Sub Minor RD 10000 - 18175 off taking at RD 7000/L of Bhagsar Minor by concrete lining M15 and Reconstruction of its aligned structure
2025_WR_150487_12
E-Tendering Notice No.11/Abohar Canal Ground Water Division /2025-26 Dated 23/09/2025
Open Tender
Civil Works - Canal
Item Rate
Sri Muktsar Sahib
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
₹1.7 L
Yes
1 Jan 2026
29 Nov 2025
5 Dec 2025
29 Nov 2025
5 Dec 2025
29 Nov 2025
Ordinary Jungle Clearance of both banks of running Disty., Minors and Drains including Boundary road with discharge upto 1.5 cumecs
Dismantling brick work, tile masonry or tile lining (in cement mortar)
Earthwork Excavation from canal using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m (As per CSR item no. 6.19) cutting
Excavation of soil using excavator and hydralic tractor trolly i/c cutting and loading in trolly and transporting to the embankment all locations including all lifts and leads, excluding royality.
Extra for laying earthwork as per specifications for compaction in 20 cm layer and dressing including cost of rolling and watering as per specifications
Dressing of Earthwork
Dressing of Dowel
Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing 0 to 1.5 mtr depth
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within lead of 30 meters.
Dressing of Side Slopes and prepration of sub grade for lining complete in all respect as per pwd specification
Laying cement water slurry 1:3, with cement @ 2.25 kg/sqms as on prepared side slopes before laying concrete on side slopes.
Shuttering for faces fo concrete foundations and foundation beam and plinth beam ( vertical or battering )
Providing & laying 250 mm wide LDPE Film 150 micron over sleepers
Extra bitumen painting at 0.69kg per sqm
Cement concrete lining 75 mm thick or less laid manually for irrigation channel using cement concrete M-15with cement content 325 Kg/cum mixed in automatic computerised batching and mixing plant and transported to site in transit mixer .
Filling Contraction Joint with sealing compound complete in all respect
Filling expansion joints with special impervious hot pour 12.5 mm wide.
Extra for compensation for ordinary earth/ordinary clay taken from any source (C.S.R. item no 6.4 a)
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation.
Laying cement concrete in 1:3:6 with stone ballast or shingle with machine mixed.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixture as per IS 1791 and vibrator by needele vibrator but excluding steel reinforcement and centring-shuttering complete in all respect.
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-1985 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Painting new letters and figures of black synthetic enamel paint to an even shade
E/W involved in constructing new O.F,A.P.M. or O.S.M. type outlets with ‘H‘ more than 0.5 m but upto 0.9 m
Dismantling O.F., A.P.M. or O.S.M. type outlets consisting of total dismantling i.e. R.C. Slab and cement Masonry with ‘H‘ more than 0.5m but upto 0.9 m
Extra labour for dressing bricks on O.F. and A.P.M. type outlets with ‘H‘ more than 0.5m but upto 0.9 m
PCC 1:4:8 with Stone Ballast 40 mm gauge using concrete mixer volume metric type
First class burnt brick work laid in cement sand mortar 1:3 in foundation and plinth.
RCC M-20 in superstructure
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering & Shuttering for flat surfaces such as roofs, landings, chajjas, shelves etc.
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.
Providing APM cast iron block complete in all respects including supply of pig iron, casting and pattern making, as per ISI specifications no. 7986-1976.(20.15 iii) (Average B of outlets is taken 0.20)
E/W involved in constructing new O.F,A.P.M. or O.S.M. type outlets with ‘H‘ more than 0.5 m but upto 0.9 m
Dismantling O.F., A.P.M. or O.S.M. type outlets consisting of total dismantling i.e. R.C. Slab and cement Masonry with ‘H‘ more than 0.5m but upto 0.9 m
Extra labour for dressing bricks on O.F. and A.P.M. type outlets with ‘H‘ more than 0.5m but upto 0.9 m
PCC 1:4:8 with Stone Ballast 40 mm gauge using concrete mixer volume metric type
First class burnt brick work laid in cement sand mortar 1:3 in foundation and plinth.
RCC M-20 in superstructure
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering & Shuttering for flat surfaces such as roofs, landings, chajjas, shelves etc.
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.
Providing APM cast iron block complete in all respects including supply of pig iron, casting and pattern making, as per ISI specifications no. 7986-1976.(20.15 iii)\ (Average B of outlets is take 0.20)
Dismantling old bridge (C.C 1:4:8)
Dismantling old bridge (Brick work)
Dismantling old bridge (RCC)
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (Depth upto 3 m) Mechanical Means
Excavation in soil using Hydraulic JCB and hydraulic tractor trolley with disposal upto 450 m i/c cutting and loading in trolley, trimming bottom and side slopes in accordance with requirement of grades and x-sections and transporting to the enbankment locations with all lifts and leads. (Rehandling of earth)
PCC M15 Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specification.
Laying Plain cement concrete (M-15) with using batching plant, transit mixer and concrete pump in sub structure, complete as per drawing and Technical specifications.
Laying RCC M-25 with using batching plant, transit mixer and concrete pump in Sub structure, complete as per drawing and Technical specifications. (Height upto 5 m)
Laying RCC M-30 for solid slab superstructure using batching plant, Transit mixer and concrete pump including cenetering & shuttering laid in position complete in all respects. (upto 5 m height)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super structure as per drawing and Technical Specification Using Batching Plant, Transit Mixer and Concrete Pump For Solid slab super-structure including centering and shuttering. RCC/PSC Grade M-40
Providing and fixing drainage spout complete as per drawing and Technical specification.
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
Providing and laying filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MORTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall/return wall to the full height compacted to a firm condition complete as per drawing and Technical specification.
Providing weep holes in brick masonry/Reinforced concrete abutment, wing wall/return wall with 100 dia PVC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face complete as per Drawing and Technical Specifications.
Providing and applying two coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ 1 Litre for 2 sqm.
Laying cement concrete M-15 mixed in Batching & Mixing Plant and transported to the site, complete in all respects.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick i/c reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be leave uniform and free from streaks and holes. (4‘‘ thick)
Hazard maker sign board 300 x 900 mm rectangular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications. Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTMD4956 09 and as per IRC 67 2012
Cautionary sign board 600 x 600 x 600 mm triangular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications. Using high intensity Microprismatic grade retro reflective Sheeting TypeXI asperASTMD495609 and as per IRC 67 2012
Mandatory sign board 600 mm circular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications. Usinghigh intensity Microprismatic grade retro reflectiveSheeting TypeXI asperASTMD4956 09 and as per IRC 67 2012
Informatory sign board 600 x 600 mm square as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications. Using high intensity Microprismatic grade retro reflective Sheeting Type XI asperASTMD4956 09 and as per IRC 6
Filling expansion joint with special bitumen material for joint size approx 20mm wide and 425mm depth
Providing and Fixing 2 mm corrugated copper plate in expansion joints, complete as per drawing and Technical specifications.
Providing & fixing 25 mm thick compressible fiber board in expansion joint complete as per drawing and technical specifications.
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply suportsd spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and technical specifications.
Providing and Fixing mild steel Hand Rail over Crash Barriers, complete as per drawing and Technical specifications.
Extra for laying earth as per specifications for Compaction of earth in 20 cm layers, dressing, watering the earth and rolling to specifications. (For ramps)
Excavation of soil using excavator and hydralic tractor trolly i/c cutting and loading in trolly and transporting to the embankment all locations including all lifts and leads, excluding royality.
First class burnt brickwork laid in cement sand mortar in 1:4 in first storey up to 4 meters above plinth level
Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.
Providing, laying, spreading and compacting stone aggregates of Grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper gra
Providing and applying primer coat with bitumen emulsion on prepared surface of granular base i/c clearing of road surface and spraying primer @ 0.85 kg/sqm using mechanical means.
de and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications
Providing and laying dense bituminous macadam (50 mm) with 100-200 TPH hot mix plant producing an average out put of 75 tonnes per hour using crushed aggregate of specified grading premixed with bituminous binder, tansported to site, laid over a previously prepared surface with paver finisher to the required grade level and alignment and rolled as per clause 501.6 and 501.7 to achieve the desired density.
Providing and laying semi dense bituminous macadam (25 mm) with 100-200 TPH hot mix plant producing an average out put of 75 tonnes per hour using crushed aggregate of specified grading premixed with bituminous binder, tansported to site, laid over a previously prepared surface with paver finisher to the required grade level and alignment and rolled as per clause 501.6 and 501.7 to achieve the desired density.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick i/c reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be leave uniform and free from streaks and holes. (4‘‘ thick)
Any other item
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.26 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.08 MB
Tendernotice_2.pdf
PDF • 0.57 MB
Tendernotice_3.pdf
PDF • 0.12 MB
BOQ_314055.xls
BOQ • 0.27 MB
TB03.xls
Tender Documents • 0.04 MB
SBD02.pdf
Additional Documents • 1.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .