Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹19.9 L+₹4.9 L (32.9%)Rejected-AOC | L2 | Rejected-AOC NOT LOWSET | |
| 3 | L3₹24.7 L+₹9.7 L (65.1%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC NOT LOWSET |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Nov 2022, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
CA NO GE S U 53 2022 23 REPAIR AND MAINT OF EARTHING/SOLAR HEATING APPLIANCES AND LIGHTENING PROTECTION OF VARIOUS CENTRAL INSTITUTE AND BLDS UNDER GE SOUTH UDHAMPUR
2022_MES_559611_1
GE/S(U)-53/2022-23
Open Tender
Electrical and Maintenance Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹40,000
12 Dec 2022
22 Oct 2022
21 Nov 2022
22 Oct 2022
19 Nov 2022
5 Nov 2022
22 Oct 2022 - 2 Nov 2022
Amount
Supply and fixing Air terminations Single pointed aluminium rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted complete all as specified and as directed.
Supply and fixing Air terminations Single pointed copper rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted complete all as specified and as directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 nos 8mm dia 25 mm hexogonal head screw including taking down old rusted complete all as specified and as directed.
Supply and fixing rectangular PVC insulators for copper/aluminium/GI strip complete all as specified and as directed.
Supply and fixing solar water heater panel 1000 LPD FPC type (Panel type) servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specified and as directed. Make:-Recold/ Tata Solar/ Solchrome Pvt
Supply and fixing solar water heater panel 500 LPD FPC type (Panel type) servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specified and as directed. Make:-Recold/ Tata Solar/ Solchrome Pvt Ltd
Supply and fixing solar water heater panel 300 LPD FPC type (Panel type) servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specified and as directed. Make : Inter Solar Pvt Ltd/Recold/ Tata Solar
Supply and fixing Heating element capacity 3 KW for Solar water heater 1000 LPD complete all as specified and as directed. Make : Recold/ Havells/ Bajaj
Supply and fixing Heating element capacity 2 KW for Solar water heater 500 LPD/300 LPD complete all as specified and as directed. Make: Recold/ Havells/ Bajaj
Supply and fixing solar flat plate collector complete all as specified and as directed. Make : Recold/Inter Solar Pvt Ltd/Tata Solar/Solchrome Pvt Ltd
Supply and fixing solar water heater tank capacity 300 LPD (Inner tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4") complete all as specified and as directed. Make - Inter Solar Pvt Ltd/Recold/Solchrome Pvt Ltd
Supply and fixing GI tubing medium grade of 15 mm bore complete all as specified and as directed.
Supply and fixing GI tubing medium grade of 20 mm bore complete all as specified and as directed.
Supply and fixing GI tubing medium grade of 25 mm bore complete all as specified and as directed.
Supply & Fixing Bib taps size 20mm , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass terrule and fixed complete all as specified and as directed.
Supply & Fixing Stop valves size 20mm,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
Supply and fixing aluminium Strip 25 x 3.15mm and fixing screws from aluminium air termination rod to test point terminal as down conductor and roof conductor including taking down of old rusted complete all as specified and as directed.. Note:- All the joints shall be made with nuts & bolts to get proper conductivity.
Supply and fixing Copper Strip 20 x 3.15mm and fixing with screws as continuous lead from Copper air termination rod to test point terminal as down conductor, roof conductor and continuous earth lead to test point terminal including taking down of old rusted complete all as specified and as directed. Note:- All the jonts shall be made with copper brazing to get proper conductivity.
Fixing only old aluminium/ copper strip of any size on insulator including straightening to old strip etc complete all as specified and as directed.
M&L for Earthing complete with Copper earth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level with top edge of earth plate not less than 1.5 m below the normal ground level) connected with and including to copper strip as earth wire 20 x 3 mm dia by means of bolts, nuts, check nuts and washers of brass all as shown in elelctrical plate No 3 including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, 40mm dia GI light grade protection pipe with funnel and wire mesh, PCC Pit in 1:2:4 type B 1 using 20mm graded stone aggregate with angle iron 40x40x5mm frame, RCC pit cover of suitable size complete all as specified and as directed. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost.
Cutting of concrete in paving exceeding 15cm thickness but not exceeding 30cm below ground level by using mechanical concrete cutting machine complete all as specified and as directed.
M&L for cement concrete type C1 (1:3:6) using 20mm graded crushed stone aggregates for making good distrubed surface as per existing finished even and smooth complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level with top edge of earth plate not less than 1.5 m below the normal ground level) connected to galvanised iron strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in elelctrical plalte No 3 including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, 40mm dia GI light grade protection pipe with funel and wire mesh, PCC Pit in 1:2:4 type B 1 using 20mm graded stone aggregate with angle iron 40x40x5mm frame, RCC pit cover of suitable size complete all as specified and as directed. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost.
M & L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6.00mm thick as earth electrode burried directly in ground earth plate not less than 2.25m deep below normal groung level with top edge of earth plate not less than 1.5 m below ground level connected to and including galvnised steel earth lead wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board / panel , watering GI pipe medium grade 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate , earth work in any type of soil, remaning surplus excavated material all as required at site and specified in Electrical plate no 3 of SSR part I 2009 complete all as specified and as directed. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost.
M&L for Rotational Moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 500 Ltrs complete all as specified and as directed.
ARNABH ASSOCIATES
SINGH CONST CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .