Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | Admitted-Finance |
| 2 | Admitted-Finance B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | Rejected-Technical Agency did not fulfill the eligibility criteria of ENIT |
Tender Value
₹5.7 L
EMD Value
₹11,500
Closing Date
29 Jul 2024, 3:00 pmClosed
Director, CSIR - IGIB
CSIR - IGIB, Mall Road, Delhi Near Jubilee Hall Hostel
Condition assessment and Structural Stability of AG-1 Building at CSIR-IGIB Mathura Road, New Delhi
2024_CSIR_201738_1
IGIB/AG-1/2024-25
Open Tender
Civil Works
Item Rate
45 days
CSIR-IGIB Mathura Road
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Director, CSIR -IGIB
₹11,500
7 Aug 2024
18 Jul 2024
30 Jul 2024
18 Jul 2024
29 Jul 2024
18 Jul 2024
Amount
Rebound hammer test to assess the strength parameters, uniformity of concrete strictly as per S: 516 (Part 5/Sec 4) using with other relevant codes with plotting of histogram as well as normal distribution graph. The Proceed calibrated Schmidt hammer shall be used for testing purpose.
Ultrasonic pulse velocity test for ascertaining the quality of concrete, uniformity of concrete in terms of soundness and density of concrete as per IS: 516 (Part 5/Sec 1). The Pundit lab or Pundit plus calibrated equipment shall be used for testing purpose. The preferably direct testing on the structural members shall be carried out.
Half-cell potential testing & analysis: for ascertaining the probability of corrosion of reinforcing steel etc. as per IS: 516 (Part 5/Sec 2)
Corrosion Analyzer:- Corrosion rate, loss of section size Steel: Identification of deterioration of steel members/joist/piping system of the existing structure by using corrosion analyzer equipment
Chemical analysis of concrete powder collected from the structure or concrete core sample/ by drilling to understand the deterioration of structure due to chemical attack and its effect on reinforcement corrosion with evaluation of the following parameters. a) Water Soluble Chloride Content % (by of mass of concrete) to check the risk of corrosion due to present chloride % as per IS: 14959 (Part 2)– 2001, B.S. 5328 Part 1, ACI 201.2R-92, BS 1881 Part 124:1988, BS 8110, IS 456:2000 b) pH Value (to check alkalinity of concrete) as per relevant B.S. 5328, ACI 201.2R-92 and ACI-318-99, IS 456:2000, BS 8110 c) Acid Soluble Sulphate Content % (by of mass of cement) to check risk of column buckling (due to volume increment of concrete) as per relevant BS 5328 code, BS 1881 Part 124:1988, BS 8110,IS 456:2000
Data analysis, investigation and interpretation for the report submission with Interpretation and Recommendation: Preparing and submitting comprehensive report consisting of findings from visual inspection, test data, interpretation of results, conclusions and final recommendations along with sketch indicating the location of the test. Recommendation part does not include the repair scheme/DPR or BOQ related to the project. The data analysis report shall be verified by the CSIR-CBRI.
BOQ, repairing methodology and retrofitting scheme for structural serviceability and safety, periodic maintenance scheme, futuristic protection of structure including repair drawings etc. The recommendation for structural repair and rehabilitation to the structures shall have detailed technical specifications, materials to be used , vulnerability indices and order of urgency to repair. The BOQ/ DPR shall be as per CPWD latest DSR and specification. The structural drawings with complete RCC details, section sizes and steel percentage by using Profometer or GPR based scanner, it will give detailed cover depth and existing protecting layer of steel rebar, diameter of steel etc. including repair/rehabilitation/ strengthening drawings vetted by the CSIR-CBRI Roorkee
Cortex Construction Solutions Pvt. Ltd.
BECQUEREL INDUSTRIES PRIVATE LIMITED
SRK Infratech Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .