Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹31.2 L+₹2.6 L (9.04%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹31.6 L+₹3.1 L (10.7%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹33.4 L+₹4.8 L (17.0%)Rejected-AOC 0 FUTANA OLI NEAR KAL BHAIRAV MANDIR KAMPTEE ROAD KAMPTEE NAGPUR MAHARASHTRA 441002 | 441002 | L4 | Rejected-AOC NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
STRUCTURAL REPAIRS TO CERTAIN VINTAGE BUILDING IN SPDC, MAHUL, WED, SEWRI AND EM INSTALLATION UNDER GE (NW) MANKHURD
2021_MES_410488_1
8041/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹90,000
Yes
10 Feb 2021
7 Jan 2021
5 Feb 2021
7 Jan 2021
3 Feb 2021
22 Jan 2021
7 Jan 2021 - 21 Jan 2021
60 days
Amount
Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc and removing debris outside MD land complete all as specified and directed.
M&L for rendering 20mm (12+8mm) thick in two coats polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemed to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
Supply only integrated Water Proofing compound
Complete removal of existing treatment of walls, chajjas, beams, parapets etc by brooming down or steel wire brushing, scraping down moulds, moss and greasy spots etc including washing down with water etc and filling cracks above 5 mm thickness with mortar using pidicrete URP of Dr fixit or equivalent of M/s STP Ltd, filling cracks less than 5 mm with Crack X paste of M/s Dr fixit or equivalent of M/s STP Ltd complete all as specified and directed.
M & L for rendering 12mm thick using polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemed to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
M&L preparation of new plaster surfaces of walls and applying two coat of oil bound distemper with wall care putty and matching with old plastered surface over a coat of primer complete all as specified and directed.
M & L for rendering 5 mm thick using polymer modified ready mix cement based plaster on the ceiling surfaces including finishing the surface of top layer even and smooth complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemed to be include for the provision of dubbing of the surface and nothing extra shall be payable on this account. The rate also includes the rate of scaffolding and necessary safety measurements
M& L for preparation of newly plastered surface and applying three coat of white wash on wall complete all as specified and directed.
M& L for preparation of newly plastered surface and applying three coat of white wash on ceilings complete all as specified and directed
M&L for preparation of old distermpering surfaces and applying two coat of oil bound distemper over a coat of primer including stopping of nails holes,cracks etc on old surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note : The rate of above item is inclusive of all patch work repair with 3mm putty where ever required.
M&L preparation of old surfaces on walls (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
All as per item No 12 above but on ceiling.
M & L for 20 to 25mm thick machine cut, polished kota stone slab in flooring and as , in single piece, in window cill, tread and riser of steps, landing , skirting, dado and pillar and similar work, laid over and including backing coat, in CM 1:4, 15 mm thick, jointed with grey cement slurry mixed with pigment to match the shade of the slab including taking down/dismantling old one complete all as specified and as directed
Dismantling asbestos and steel corrugated, semicorrugated etc sheets in roof covering, cladding etc and stacking for issuing under Sch. of credit.including scaffolding and necessary safety arrangements complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including scaffolding and necessary safety arrangements complete all as specified and directed.
S&F M.S post and struts in fencing, joist, channel, angle or tee for posts,truss, support for sheeting , ladder , sheet etc cutting tops to shape as directed drilling holes notching for wire etc including bolts at any height including necessary scaffolding and safety arrangements complete all as specified and directed.
M&L for preparing of new steel surfaces of applying two coat of sythetic enamel paint over one coat of red oxide Zinc chrome primer any description ,over 10cm in width or girth not otherwise described complete all as specified and directed.
All as per item No19 above but one coat of synthetic enamel paint on existing steel surface including preparation of surfaces complete all as specified and directed.
Providing & casting & Repairing of excessively damaged members with Micro-concrete at all levels with all leads & lift or as directed including formwork, centering, scaffolding, & mixing , laying, levelling, and finishing including curing etc. complete (excluding steel reinforcement) for thickness more than 40 mm complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors / dados, etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L screed bed or bedding layer 15 mm thick for laying floor finishes in cement mortar 1:6 to receive tiles complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 to receive wall tiles complete all as specified and directed.
M&L for coloured glazed ceramic tiles 300 mm x 200mm x 7mm thick as in walls etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
M&L for coloured non skid ceramic tiles 300 mm x 300mm x 6 to 7mm thick as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
Taking down aluminium windows,chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each.incl taking down deco grill and refixing the same after cleaning, repairing, changing of locks,rubber beading, rollers etc complete all as specified and directed.
All as per ser item No 27 above but exc 1.5 sqm and n. exc 4 sqm complete all as specified and directed.
S&F in repair 4.8mm thick plain / sheet glass, ordinary quality cut to required size and shape for wooden/aluminium sliding windows / ventilators / doors, etc. including taking down joinery and refixing in the same position complete all as specified and as directed.
S&F in repair 4mm thick glass pin headed ordinary quality in each pane for aluminimum sliding window area exc 0.5sqm in each pane including taking down joinery and refixing in the same position complete all as specified & directed.
S&F in repair aluminium wire mesh, 0.36mm nominal dia of wire and average width of aperture 1.40mm, cut to required size for fixing to doors / window (wooden/ aluminium) shutter, with stainless steel wire staples,etc. including taking down joinery and refixing in the same position complete all as specified and as directed.
M&L Machine cut cudappa stone slab flooring 20-25mm thick as in cill of window laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over & including 15 mm thick screed bed in cm 1:6 complete all as speicfied and directed.
Demolition of cement concrete (unreinforced) as in water tank platform, kerbs etc on roof and removing the retrieved debris outside MOD land complete all as specified and directed.
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in water tank platform over RCC roof surface or for in benching or kerbs etc including making rounded or chamfered on edges mixed with WPC @2% by weight of cement including necessary form work complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Disconnecting existing water storage tanks upto and including 2000 litres, setting aside (or lowering if required) for repairs to roof below, and replacing (or hoisting if required), re-fixing in position and re-connecting on completion of roof work complete all as specified and directed.
Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and removing rubbish, out of MD land complete all as specified and directed.
M&L for rendering 20mm thick in CM 1:4 on roof /parapet wall surfaces as in levelling course, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of existing water proofing treatment and providing and laying ShaliUrethane BTD of STP Ltd or equivalent, Poly Urethane based roof water proofing treatment using high elongation based (>500%) liquid applied elastomeric water proofing membrane with separate wearing course as per ASTM C-836. Thickness of the membrane shall be 1.5mm including reinforcement. After surface cleaning, prime the surface with mixture of ShaliUrethane BTD: Water:: 50:50 ratio and apply @400gm/sqm. After complete drying the surface has to be dampened with coating. Subsequently apply 2 coats of ShaliUrethane BTD by brush or roller on primed surface @1kg/sqm to get required thickness with non woven FG reinforcement surface complete all as per Manufacturer’s Instruction all as specified and directed.”
M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%.
Demolition of brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles and removing debris outside MD land complete all as specified and directed.
M & L Brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius in CM 1:6 etc complete all as specified and directed.
Drilling and fixing Teflon nozzles in RC members, including, Drilling Holes:Drilling 14mm dia, 50 to 100mm deep holes in structural members at the intervals of 600mm in staggered manner or as directed by the consultants in RC structural element. Cleaning of Holes: Clean the holes by air blower prior to fixing nozzles. Fixing of nozzles: Insert Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing.Cure the system for min.12 hrs.Grouting Injecting Super low viscosity epoxy resin by pressure and using injector with accessories till nozzles refused to accept the grout, Including,Mixing of materials: Mixing material components in required quantities as per mfg instruction by weigh batching. Cutting of nozzles: Cut the nozzles by chisel after completion of grouting without damaging structural elements.
Providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc. and anchoring reinforcement bar in existing RCC member in holes of minimum 10d depth for 8 to 12 mm dia bar complete all as specified and directed.
Chipping , removing, carefullly loose concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Note : Hard concrete should not be removed by force.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) AND M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. Note : A sum of Rs 10,080.00 towards sch of credit shall be deducted to arrive the contract sum
Parmatma Enterprises
Sunil Construction
S.N Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .