SE EDC Etah
Vidhyut Colony, Aruna Nagar, Railway Road, Etah.
Work of Maintenance of HT/LT/33 KV lines in the area of EUDSD IInd Etah under EUDD Etah.
2024_DVVNL_922741_2
143/2023-24/EDC ETAH
Open Tender
Electrical Works
Item Rate
Distt Etah
As per Tender Documents
2 documents required · 2 mandatory
₹1,180
DVVNL
₹2,000
17 Jun 2024
31 May 2024
11 Jun 2024
31 May 2024
11 Jun 2024
31 May 2024
Amount
Safe carriage of 8.5/9 mtr. long PCC pole from store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 10 Km. including loading & unloading at both ends.
Safe carriage of 9/11/13 mtr STP from store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 10 Km. including loading & unloading at both ends.
Safe carriage of line material from store center Etah/nearest substation to pit site in distance range 0 to 10 Km. including loading & unloading at both ends.
Opening of binding & removal of following conductor with 33 KV/HT/LT line from broken PCC poles/rails/ STP and stacking at safer place.
Dog/ Raccoon/ Rabbit conductor
AAAC/ACSR weasel conductor/ GI wire.
ABC 3X95+1X35+1X16/3X50
ABC 3X120+1X70+1X16
Erection of 8.5/9 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc. complete. Pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 9/11/13 mtr.STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 8.5/9 mtr. long PCC poles as Double Pole/section pole including drilling,cutting etc. and fixing of all accessories etc. complete. Pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 9/11/13 mtr. STP as Double Pole/ section pole including drilling,cutting etc. and fixing of all accessories etc. complete. Pole should be grouted properly as per DVVNL/RESPO norms.
Laying stringing & sagging of 3 phase 3 wire 33/HT/LT line with ACSR/ weasel/ Reccoon/Dog conductor including binding and nuzzling etc. complete.
Dog/ Raccoon/ Rabbit conductor
AAAC/ACSR weasel conductor/ GI wire.
ABC 3X95+1X35+1X16/3X50
ABC 3X120+1X70+1X16
Straighting of tilted PCC poles/STP/Rail single support of HT/LT line after opening of nuzzling, digging of pit applying anti direction force for making of proper alignment of line.
Straighting of tilted D/P after opening of connection applying anti direction force, digging of dug for proper alignment of line including reconnection etc. complete.
Opening of HT/LT connections & lowering of following T/F from D/P/Plinth and shifting up to in safer place.
25/63 KVA T/F
100 KVA T/F
Dismanteling of old/damage STP/RS Joist of HT/LT line and carriage to store centre Etah
Re-sagging of loose 33/HT/LT conductor after opening, binding, nozzling etc.
Dog/ Raccoon/ Rabbit conductor
AAAC/ACSR weasel conductor/ GI wire.
ABC 3X120+1X70+1X16
ABC 3X95+1X35+1X16
ABC 3X50+1X35+1X16
Replacement of following broken/damaged/missing accessories by new accessories including opening of the same and refixing.
11 KV cross arms V type
11 KV pin insulator
11 KV pin with nut
11 KV Disc insulator
Cross Arms holding clamps
F Clamps
LT shackle insulator
33 KV cross arm.
33 KV pin with nut
33 KV pin insulator
Retightining of Stay rod. Etc. complete.
Providing fixing of stay rod with nuzzling etc. complete.
Earthing of PCC/RS Joist/STP as per RESPO norms.
Carriage of old material from pit site to JE store/store center, Etah in distance range 0 to 10 km including loading & unloading and proper stacking.
Mounting of Following Transformers on double pole/Plinth including making of the connection etc complete.
25/63 KVA T/F
100 KVA T/F
Chopping of tree branches
Disconnecting of LT service line of following category of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of clamp/connectors etc. for consumer service cables after commissioning of line.
Single phase consumer.
Three phase consumer.
Repairing/ Resagging /New guarding of HT lines with GI wire as per RESPO norms.
GARG ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .