Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC | ₹3.5 L Quoted ₹4.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹4.7 L+₹72,661.18 (18.2%)Rejected-Finance | ₹4.7 L+₹72,661.18 (18.2%) | L2 | Rejected-Finance Highly Quoted |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non-Responsive |
Tender Value
₹3.4 L
Closing Date
15 Nov 2021, 5:00 pmClosed
Sr. Manager(PnC)
Rangit Power Station,Rangit Nagar,South Sikkim
Internal Electrification of Work Shop Office and Store and restoration of HRT HT (11KV) Line at Rangit Nagar Colony, Rangit Nagar
2021_NHPC_653139_1
NH/RPS/ECD014(12)/1/2021- ECD/001743/302
Open Tender
Miscellaneous Works
Works
30 days
Rangit Power Station, Rangit Nagar, South Sikkim
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
NHPC Limited
Yes
2 Jun 2022
18 Oct 2021
22 Nov 2021
18 Oct 2021
15 Nov 2021
18 Oct 2021
Ceiling Fan 1200mm 48" (Havells/USHA) Confirming to IS:374
LED Tube Lights Batten Confirming to IS: 16102 Led Tube Light Neptune Silver 20 Watt
Electronics Fan Regulator(EME) Deluxe 120/280V
Ventilating Fans 250mm 10" (Havells)
LED Flood Lights Confirming to IS:16101 LED Flood Light 45 Watt
Surface mounted CRCA LED Panel Confirming to IS : 16102 LED CRCA Panel 18W ECW 1x1 ft.
Concreting of 11Mtrs Lattice Structure / Swaged STP in 1:4:8 cc in 0.9x0.9x2.05mtrs cement plaster of parapet in 1:4 mix.
Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate
Concreting of H.T Guy Assembly in 1:4:8 cc in 0.40x0.40x1.05mtrs Pit.
G.I Earth Spike conforming to IS 227.
G.I Strips 35x6 mm of 1 Mtr length conforming to IS 227.
Danger Board 11000Volts
Anticlimbing Device GI Barbed Wire
GI Wire 8 SWG
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 100 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 180 mm X 100 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
M/S KAMAKHYA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .