GE (AF) JORHAT
GE (AF) JORHAT PIN 785005
REPAIR MAINT OF UG CABLE LT PANELS SECURITY LIGHTS AND REPLACEMENT OF ALLIED ACCESSORIES IN VARIOUS SUB STN AT AFS AND AFH UNDER GE AF JORHAT
2020_MES_361360_1
8810/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) JORHAT
Class D category b i
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹72,000
Yes
28 Aug 2020
16 Jul 2020
8 Aug 2020
16 Jul 2020
6 Aug 2020
31 Jul 2020
Amount
Disconnecting/Taking down UNSV following Street / Perimeter / Garden / Security Roadway / Mast Light fittings from pole/Structure for repair / checking and identifying of foulty spares wirings, cleaning of fittings, cover, etc. and re assembling the same after repair, testing and refixing in original position and reconnecting with the electrical line complete all as directed by Engr-in-Charge. (Replacement of parts/ repairs shall be measured and paid separately under relevent items here in after).
S&F electronic driver of 25 Watt LED security light fittings complete all as specified and as directed. Make: Havells / Philips/Bajaj/CG
S&F electronic driver of 45 Watt LED security light fittings complete all as specified and as directed. .Make: Havells / Philips/Bajaj/CG
S&F electronic driver of 75 Watt LED security light fittings complete all as specified and as directed. .Make: Havells / Philips/Bajaj/CG
S&F in repair 30 Watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium aesthetically designed roadway luminaire with high power LEDs as light source & electronic driver,,including cable for connection after taking down old unserviceable light fittings, complete all as directed. .Make:Crompton Cat No-LSTS-30-CDL/NL-M) or equivalent model in Philips/GE
S&F in repair 45 Watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium aesthetically designed roadway luminaire with high power LEDs as light source & electronic driver,,including cable for connection after taking down old unserviceable light fittings, complete all as directed. .Make:Crompton (Cat No- LSTS-45-CDL-M) or equivalent model in Philips/GE
S&F in repair 60 Watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium aesthetically designed roadway luminaire with high power LEDs as light source & electronic driver,including cable for connection after taking down old unserviceable light fittings, complete all as directed..Make:Crompton (Cat No- LSTP-60-CDL-M) or equivalent model in Philips/GE
S&F in repair for 40W LED post top with moonlight effect and efficient light distribution and IP65 protection,including cable for connection after taking down old unserviceable light fittings, complete all as directed..Make:Crompton (Cat No- LPTM-40-CDL-M) or equivalent model in Philips/GE
S&F in repair 72 Watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium aesthetically designed roadway luminaire with high power LEDs as light source & electronic driver,,including cable for connection after taking down old unserviceable light fittings, complete all as directed.Make:Crompton (Cat No- LSTP-72-CDL-M) or equivalent model in Philips/GE
S&F in repair 90 Watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium aesthetically designed roadway luminaire with high power LEDs as light source & electronic driver,,including cable for connection after taking down old unserviceable light fittings, complete all as directed.Make:Crompton (Cat No- LSTP-90-CDL-M) or equivalent model in Philips/GE
Supply and fix in repair LED aviation light luminaries comprising of alluminium housing with polycarbonate encloser with 302 nos LED ,including cable for connection after taking down old unserviceable light fittings, complete all as directed Cat No. BGAV302 LED of make Bajaj or equivalent model in Philips/ CG
S&F in repair for 200 Watt LED flood light fitting, LED floodlight luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete including clamp,nut,bolt and other accessories for fixing,including cable for connection after taking down old unserviceable light fittings, complete all as directed.Make-Crompton Cat No-LFLN-100-CDL/60-M or equivalent model in Philips/GE
S&F in repair for 150 Watt LED flood light fitting, LED floodlight luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete including clamp,nut,bolt and other accessories for fixing ,including cable for connection after taking down old unserviceable light fittings, complete all as directed.Make-Crompton Cat No-LFLN-150-CDL/60-M or equivalent model in Philips/GE
S&F in repair for 120 Watt LED flood light fitting, LED floodlight luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete including clamp,nut,bolt and other accessories for fixing,including cable for connection after taking down old unserviceable light fittings, complete all as directed.Make-Crompton Cat No-LFLN-120-CDL/60-M or equivalent model in Philips/GE
S&F in repair street light bracket on poles fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.0 mtr complete with mounting MS clamp of flat iron size 25X5 mm of suitable length 02 pairs including nut bolts etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide metal primer all as specified and directed by Engr In charge.
S&F in repair cable junction box 200X160X98mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. Make : Cat No. K-9250 of HENSEL or equivalent model in Sintex/C&S Elect Ltd.
Supply and fix in repairs Polymide cable gland complete all as specified and as directed. Make: Cat no 1555.N0750.18 of HENSEL or equivalent model in Sintex/C&S Elect Ltd.
Supply and fix in repairs Polymide cable gland complete all as specified and directed . Make Cat no 1555.N1000.22 of HENSEL or equivalent model in Sintex/C&S Elect Ltd..
M&L in repair for PVC insulated three core 2.5 sqmm multistrand aluminium conductor for connection of Securiry light from Junction Box to Security light, complete all as specified and directed.
Supply and fixing in repair/passing through steel tubler pole or service connection,in repair 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, three core cable of size 4 sq mm complete all as specified and as directed.
S&F in repair timelite distribution board, 40 Amps 3Pole/240 volts AC 50 Hz,astronomical time switch including all necessary connections complete all as specified and directed. Make : Indo Asian (Cat No. TL040AS0) or equivalent in Havells/ C& S
Taking down/out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed. (NOTE : Earth Work shall be Measured and Paid for separately under relevant Items).
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 10 Sqmm 4 Core complete all as specified and directed.
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 16 Sqmm 4 Core. complete all as specified and directed
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 25 Sqmm 3.5 Core complete all as specified and directed.
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 50 Sqmm 3.5 Core complete all as specified and directed.
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 70 Sqmm 3.5 Core complete all as specified and as directed.
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 95 Sqmm 3.5 Core complete all as specified and as directed.
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable for 1100 Volts grade cross Sectional area 185 Sqmm 3.5 Core complete all as specified and as directed.
Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 25 Sqmm 3.5 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.
Re-Laying/ refixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 70 Sqmm 3.5 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.
Re-Laying/ refixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 95 Sqmm 3.5 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.
Re-Laying/ refixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 185 Sqmm 3.5 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.
M&L cable jointing kit for 11KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm joint and testing complete all as specified and as directed.
M&L cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm joint and testing complete all as specified and as directed.
S&F in repair straight through (Epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area exc. 6 Sqmm but not exc. 16 Sqmm, 4 core and testing complete all as specified and as directed.
S&F in repair straight through (Epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area exc. 25 Sqmm but not exc. 50 Sqmm, 4 core and testing complete all as specified and as directed.
S&F in repair straight through (Epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC/XLPE insulated aluminium stranded conductor of nominal cross-sectional area exc. 70 Sqmm but not exc. 120 Sqmm, 4 core and testing complete all as specified and as directed.
S&F in repair straight through (Epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC/XLPE insulated aluminium stranded conductor of nominal cross-sectional area exc. 150 Sqmm but not exc. 185 Sqmm, 4 core and testing complete all as specified and as directed.
Excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, (for taking out and laying of cables, etc.) and getting out in soft/ loose soil, complete all as specified and as directed.
Returning, Filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230 mm spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid ).
S&F Sub-Class B brick, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed.
Relaying only Class B brick, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed.
S & F in repair 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed .
S & F in repair 50 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed .
S&F in repair Galvanised iron pipe 50 mm bore dia,light grade for mechanical protection of earth strip of chemical earthing etc including taking down unserviceable. Make: Jindal/Prakash/Surya Roshni /Tata
Labour only for Horizontal Boring by Passing Protection Pipe up to 80 mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed.
Material and labour for painting to steel tubular pole 8.5 to 11 metre long with two coats of synthetic enamel paint up to 1.50 metre height from ground level in 30 cm alternative black and yellow strips and painting remaining portion with alluminium paint incl numbering of pole no by stensils and painting MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
Material and labour for Painting of LT panel/feeder pillar any size after cleaning the body surface of transformer by rubbing with emery Paper to remove rust, dust etc and applying two coat of synthetic enamel paint complete all as specified and directed.
S&F in repair MCB TPN 63 A, 240 Volts,50 Hz, 10 KA, C Series including necessary incoming and out going electric connection with suitable size of copper lugs etc as in repair complete all as specified and as directed.
Supply and fixing in repair MCCB 4 Pole 125 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.
Supply and fixing in repair MCCB 4 Pole 160 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.
Supply & fixing in repair breather assembly of approved make filled with silica gel suitable for transformer of 100 to 150 KVAcapacity complete all as specified and directed.
Supply & fixing in repair breather assembly of approved make filled with silica gel suitable for transformer of 200 to 315 KVAcapacity complete all as specified and directed.
Supply & fixing in repair breather assembly of approved make filled with silica gel suitable for transformer of 400 to 500 KVAcapacity complete all as specified and directed.
Supply & fixing in repair breather assembly of approved make filled with silica gel suitable for transformer of 1000 to 2000 KVAcapacity complete all as specified and directed.
Dehydration/filtration of transformer oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 60 KV at 4mm gap in existing position of transformer of any capacity and transformer oil for topping up at various sub station all as directed by Engr-in-Charge( NOTE: Transformer oil used for TOP UP measured and paid separately)
Supply and pouring of new transformer oil to achieve a di-electric strength up to 60 KV with oil testing kit 4 mm thick to top up of the transformer conforming to IS-335-1983 complete all as specified and directed.
S&F for 100 Watt highbay,light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete after taking down old unserviceable light fitting all as directed. Make:Crompton,CAT No-LHB11-100-CDL/60-M or equivalent model in Philips/GE
S&F for in repair 120 Watt highbay,light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete after taking down old unserviceable light fitting all as directed. Make:Crompton,Cat No-LHB11-120-CDL/60-M or equivalent model in Philips/GE
S&F for in repair 140Watt highbay,light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete after taking down old unserviceable light fitting all as directed. Make:Crompton,Cat No-LHB11-140-CDL/60-M or equivalent model in Philips/GE Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S SANTOSHI TRADERS
A K DUTTA CHOWDHURY AND CO
M/S PS ENTERPRISE
NIHAR ENTERPRISE
RAJIB AND CO
KAY CEE CO. INDIA
satyabhama and co
M D Constructions Co
M/S KRISHNA CONSTRUCTION CO
Bidder Name
KAY CEE CO. INDIA
A K DUTTA CHOWDHURY AND CO
NIHAR ENTERPRISE
satyabhama and co
M D Constructions Co
M/S BARUAH ELECTRICALS
M/S PS ENTERPRISE
RAJIB AND CO
M/S SANTOSHI TRADERS
M/S KRISHNA CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .