Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | ₹9.3 L | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Finance HOUSE NO 1 6 2206 PANDURANG RESIDENCY BEED | BEED | BEED | MAHARASHTRA | - | - | Not Admitted-Finance Not qualified for AOC |
| 3 | Not Admitted-Finance AT 267 RANGAR CHOWK GEORAI DIST BEED | GEORAI | BEED | MAHARASHTRA | - | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹9.3 L
EMD Value
₹9,317
Closing Date
23 Mar 2026, 5:00 pmClosed
Executive Enginner W D 02 Z P BEED
Executive Enginner W D 02 Z P BEED
ZPBEED/WD2/DPDC/181/2025-26
2026_BEED_1287500_1
ZPBEED/WD2/DPDC/181/2025-26
Open Tender
Civil Works
180 days
BEED
Registration Cert., ITR, GST, PAN Card etc As per Tender Conditions
2 documents required · 2 mandatory
₹1,000
₹9,317
25 Apr 2026
16 Mar 2026
24 Mar 2026
16 Mar 2026
23 Mar 2026
16 Mar 2026
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. ( 0.4572X0.6096 = 0.278 SQ.Mtr plywood to fix DTC Mteter in CRCA sheet box Such 1 box So 0.278x1No.=0.278 sq.mtr.)
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (To prepared DTC meter box CRCA sheet 12 SWG is proposed. Weight of CRCA sheet /sq.mtr is 19.61Kgs./sq.mtr. Size of box is 0.4572x0.6096x2+0.4572x.04x2+0.6096x0.4x2=1.41 sq.mtr. waight of [email protected]/sq.mtr. i.e 1.41 sq.mtrx19.61kg=27.65 Kgs. Total waight = 27.65 Kgs.)
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting inline cut point end pole D. P. Structure for 11/0.415 kV, 63 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 100 Amps as incomer & 6 Nos. 63 Amps Kitkat /MCCB for outing circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box, Transformer Belt etc. as per drawing (min. 176 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 63 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound without gas cushioning hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 340 Watts at 50% load, 1140 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL
Supplying and erecting hard drawn copper solid wire no. 0 to 6 SWG complete erected for connections on H.T. sides. (6 SWG Copper solid wire 6mtrs. @0.1668kg/mtrs. So 6 mtrs.x0.1668Kg.= 1 Kg.)
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. On existing H.T Line pole i.e pole No.0, for erection of disc insulator, 100x50x5 mm. @9.6 Kgs/mtr. 1.6 mtrs. in length channel is proposed. And On pole to support the channel, 1.5 mtrs. on both side i.e 1.5x2=3 mtrs. 50x50x6 mm stud angle is proposed. @ 4.5 Kgs./mtr. So total weight 4.5 x3 mtrs.= 13.5 Kgs. So total weight of channel and angle is.=15.36 Kgs. mtrs.+13.50 Kgs. =28.86 Kgs. Total waight 28.86 Kgs.)
Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ ( 9 Mtrs. Hight 9 Poles i.e 9 poles x 9 mtrs.= 81 mtrs )
Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA ( Per H.T pole 1 No.)
Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA ( Per H.T pole 1 No.)
Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA
Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.
Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR
Providing and fixing GI earthing stud with necessary materials .
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI
Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete.
Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete(60mt./span For 11 span. So for 60+60 span=120 mtrs./span 11span x 90mtr x 2%sag = 1009.80 mtrs. @0.1465Kg.= 147.93Kgs.)
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).(3.5Mtrs./pole. So for 11 pole i.e 11 polex3.5 mtrs.= 38.50 mtrs. Weight 6.044mtrs./Kg.So 38.50 mtrs./6.044= 6.370 Kgs.)
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
SBD181.pdf
Tender Documents • 2.19 MB
BOQ0181.xls
Other Document • 0.41 MB
Download all tender documents and submit your bid