Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 736 PARAGDAS MANDIR NIRMOCHAN GHAT AYODHYA 224123 | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.0 L+₹72,902.80 (4.49%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹17.5 L+₹1.3 L (7.78%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹19.9 L+₹3.7 L (22.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹21.8 L+₹5.6 L (34.4%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Mar 2023, 6:00 pmClosed
GE (MES) Ayodhya
Garrison Engineer Military Engineer Services Ayodhaya PIN-224001
REPAIR MAINT OF DG SETS, PUMP MOTORS, PUMP PANELS WITH ALLIED WORKS AT AYODHYA CANTT UNDER GE AYODHYA
2023_MES_580552_1
8355/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Ayodhya
₹50,000
Yes
11 Apr 2023
13 Feb 2023
15 Mar 2023
13 Feb 2023
13 Mar 2023
28 Feb 2023
Amount
Periodical maintenance for entire duration of contract including complete servicing of Diesel Engine Generator set of 160 KVA capacity at Military Hospital of make: Kirloskar or any other make as per site requirement and connected accessories including replacement of oil /lubricant filter to keep the plant in running condition including routine maintenance complete all as specified and as directed. Note:- (i) The Contractor need to get the job done through authorised service centre/ agency of Kirloskar Oil Engine Ltd or any other OEM (Original Equipment Manufacturer) located near Ayodhya. The cost thereof deemed to be included in the quoted rate. (ii) All Spare parts for routine maintenence shall be measured and paid for separately under relevent items of this BoQ at 'Supply Only' rates (iii) Labour charges for routine maintenance including properly dismantling of old parts deemed to be included in the quoted rate
All as per Srl item No. 1.00 here-in-before but of Diesel Engine Generator Set of 62.5 / 63 kVA capacity at Pump House No 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, STP Himachal Niwas, STP Kandahar Line, Signal Centre and Amn Dump Trolly Mounted
All as per Srl item No. 1.00 here-in-before but of Diesel Engine Generator Set of 40 KVA capacity at Records
All as per Srl item No. 1.00 here-in-before but of Diesel Engine Generator Set of 15 KVA capacity
Supply only Lubricant oil filter for routine maintenance of DG Set 160 KVA, complete all specified and directed by Engr-in-Charge.
All as per Srl item No. 5.00 but Fuel filter (Pre)
All as per Srl item No. 5.00 but Fuel filter (Micro)
All as per Srl item No. 5.00 but Air filter outer
All as per Srl item No. 5.00 but Air filter inner
Supply only Lubricant oil filter for routine maintenance of 15 - 62.5 KVA DG Set complete all specified and directed by Engr-in-Charge.
All as per Srl item No.10.00 but Fuel filter (Pre)
All as per Srl item No.10.00 but Fuel filter (Micro)
All as per Srl item No.10.00 but Air filter outer
All as per Srl item No.10.00 but Air filter inner
Supply only Coolant for DG Set complete all specified and directed by Engr-in-Charge.
Supply only Lub Oil for DG Set of make Koel Care Premium Genuine complete all specified and directed by Engr-in-Charge.
M&L for Head Gasket set (Cylinder head) of capacity 160 KVA DG set make: Kirloskar or equivalent complete all specified and directed by Engr-in-Charge. Note :- Labour charges for properly dismantling of old parts deemed to be included in the quoted rate.
All as per Srl item No.17.00 but Alternator coupling
All as per Srl item No.17.00 but Starter Ring
All as per Srl item No.17.00 but ON/ Off push button set
All as per Srl item No.17.00 but Cut out for charging alternator
All as per Srl item No.17.00 but Ignition Switch for charging alternator
All as per Srl item No.17.00 but Switch Plate for charging alternator
All as per Srl item No.17.00 but Diode Plate for charging alternator
All as per Srl item No.17.00 but Carbon for charging alternator
All as per Srl item No.17.00 but Bulb Holder for charging alternator
All as per Srl item No.17.00 but Rectifier Assembly for charging alternator
All as per Srl item No.17.00 but Brush Box Assembly for charging alternator
All as per Srl item No.17.00 but Bearing for charging alternator
All as per Srl item No.17.00 but Oil seal for charging alternator
All as per Srl item No.17.00 but Field Coil for charging alternator
All as per Srl item No.17.00 but Hose : Water Pump inlet to Radiator outlet
All as per Srl item No.17.00 but Hose :Pipe to Water Pump
All as per Srl item No.17.00 but Hose : Pipe to Diesal tank
All as per Srl item No.17.00 but Hose pipe with 04 nos clip & nut
All as per Srl item No.17.00 but Terminal block
All as per Srl item No.17.00 but Fan Belt
All as per Srl item No.17.00 but Automatic Voltage Regulator
All as per Srl item No.17.00 but Water Pump Repair Kit
M&L for Head Gasket set (Cylinder head) of capacity 15 - 63 KVA DG set make: Kirloskar or equivalent all as specified and directed by Engr-in-Charge. Note:- Labour charges for properly dismantling of old parts deemed to be included in the quoted rate
All as per Srl item No. 40.00 but Alternator coupling
All as per Srl item No. 40.00 but Starter Ring
All as per Srl item No. 40.00 but Expansion bellow
All as per Srl item No. 40.00 but ON/ Off push button set with wiring
All as per Srl item No. 40.00 but Cut out for charging alternator
All as per Srl item No. 40.00 but Ignition Switch for charging alternator
All as per Srl item No. 40.00 but Switch Plate for charging alternator
All as per Srl item No. 40.00 but Diode Plate forcharging alternator
All as per Srl item No. 40.00 but Carbon for charging alternator
All as per Srl item No. 40.00 but Bulb Holder for charging alternator
All as per Srl item No. 40.00 but Rectifier Assembly for charging alternator
All as per Srl item No. 40.00 but Brush Box Assembly for charging alternator
All as per Srl item No. 40.00 but Bearing for charging alternator
All as per Srl item No. 40.00 but Oil seal for charging alternator
All as per Srl item No. 40.00 but Field Coil for charging alternator
All as per Srl item No. 40.00 but Hose : Water Pump inlet to Radiator outlet
All as per Srl item No. 40.00 but Hose :Pipe to Water Pump
All as per Srl item No. 40.00 but Hose : Pipe to Diesal tank
All as per Srl item No. 40.00 but Hose pipe with 04 nos clip & nut
All as per Srl item No. 40.00 but Terminal block
All as per Srl item No. 40.00 but Fan Belt
All as per Srl item No. 40.00 but Automatic Voltage Regulator
All as per Srl item No. 40.00 but Water Pump Repair Kit
M&L for Calibration of Fuel Injection Pump including properly dismantling and transporting to & fro service center/ workshop for over hauling/ calibration and refixing on DG Set after calibration for DG Sets of capacity 160 KVA including replacement of following items all as directed by Engr -in charge : (a) Element - 06 Nos, (b) D.V - 06 Nos, (c) T.R.B - 06 Nos, (d) Bearing - 02 Nos, (e) C.R - 01 Nos, (f) C.R Bush - 02 Nos, (g) Ball Bearing - 01 No., (h) F.P.P - 01 No., (i) F.P Kit - 01 No., (j) Pressure Bolt - 06 Nos, (k) Nozzle seal - 02 Nos, (l) Nozzle setting - 06 Nos & with all other neessary items .
All as per Srl item No. 64.00 here-in-before but for DG Sets of capacity 62.5/ 63 KVA
All as per Srl item No. 64.00 here-in-before but for DG Sets of capacity 15 KVA
S&F in replacement Banjo Bolt M 14 x 1.5 including taking out of old one all as directed by Engr -in charge.
S&F in replacement Flexible fuel pipe type 7.5 14 x 14 B 700 PB of make: Kirloskar or equivalent including taking out of old one complete all as directed by Engr -in Charge.
S&F in replacement Fuel Pump mounted STOP solenoid switch suitable for 15 to 62.5-63 kVA DG set of make: Kirloskar or equivalent including taking out of old one complete all as directed by Engr-in-Charge.
M&L for servicing of radiator including cleaning and testing of leakages for DG set of capacity 160 KVA all as specified and as directed. Note: - In case of leakages found during servicing, the same shall be measured and paid for separately
All as per Srl item No. 70.00 above but for DG set of capacity 15- 63 KVA
Dismantling the radiator and transporting to workshop, repair of all leakage and transporting back and refitting in original position and testing for DG set of capacity 160 KVA all as directed by Engr-in-Charge.
All as per Srl item No. 72.00 above but for DG set of capacity 15- 63 KVA.
M&L for dismantling the fuel tank carefully and transporting to workshop, repair of all leakage, cleaning and transporting back and refitting in original position and testing after completion for DG set of capacity 160 KVA all as specified and as directed including taking out of old one complete all as directed by Engr-in-Charge.
All as per Srl item No. 74.00 above but for DG set of capacity 15- 63 KVA.
S&F self starter of DG set of capacity 62.5/ 63 KVA 12/24 Volts of any make and model compatible with the existing one complete all as directed Engr-in-Charge.
All as per Srl item No. 76.00 above but for DG set of capacity 15 KVA.
M&L for dismantling the self starter carefully of DG set of capacity 62.5/63 KVA and transporting to workshop and reffiting back after repair with replacement / repair of the following items :-
Supply only Carbon bush with spring material for repair of self starter of DG set of capacity 15-160 KVA, complete all as directed Engr-in-Charge.
All as per Srl item No. 79.00 here-in-before but GM Bush set
All as per Srl item No. 79.00 here-in-before but Bendex Pinion
All as per Srl item No. 79.00 here-in-before but Solenoid Switch
All as per Srl item No. 79.00 here-in-before but Armature Rewinding
All as per Srl item No. 79.00 here-in-before but Field Coil set
Supply only lead acid battery 12 Volt 180 Ah including initial charge of make: Exide or equivalent complete all as directed by Engr-In-Charge
Dismantling existing earthing of any description and M&L for new Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick, burried directly in ground vertically to a depth not less than 2.50 m below the ground level with top edge of earth plate at a depth not less than 1.50 m below ground level. Earthing plate surrounded by 15mm thick packed alternative layers of charcoal dust and common salt, connected with GI strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles at one end and the other end connected to main switch board and protected by 25mm dia bore light grade GI pipe. Provision of 20mm dia bore light grade GI pipe for watering including GI funnel and wire mesh. The pipe shall be provided vertically upto top level of earthing pit and then taken horizontally to the equipment. Provisionn of cement concrete chamber with PCC (1:3:6 ) type C-2 (using 40 mm graded stone aggregate), constructed at 1.00 m one metre away from edge of earthing pit with 50 mm thick precast concrete cover of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) including all necessary earthwork in soft / loose soil complete all as specified and shown in Electrical Plate No. 3 of SSR Part-1 (2009) and directed by Engr-in-Charge.
S&F in replacement, MCCB 4 pole 100 Amps, 415 Volt, 10-25 KA in existing panel including taking out old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, On load Changeover 4 pole, 100 Amps, 415 Volt, in sheet steel enclosure type including taking out of old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, On load Changeover 4 pole 100 Amp, 415 volt, open execution type in existing panel including taking out of old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, Single phase Preventer Relay with adjustable time delay 30 sec to 5 min suitable for 415 volt AC, any type of make: L&T or equivalent including internal wiring from switchgear to relay in existing panel complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, digital type Voltmeter with LED display suitable for 3 phase in existing panel including taking out of old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, 3 pole power contactor 220/440 volts with 50 Amp AC3 duty rating any type including auxillary switch of make: L&T or equivalent in existing panel including taking out of old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, electronic timer for automatic star delta starter 415 volt 50 Hz 3 - 30 sec of make: L&T, in existing panel including taking out of old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, digital type Ammeter with LED display suitable for 3 phase in existing panel including taking out of old one complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, overload Relay any type suitable for 5 Amp to 30 Amp 415 volt AC of make: L&T or equivalent including internal wiring from switchgear to relay in existing panel complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, three phase submersible pump controller with single phase preventer of rating 3 phase,415V,50 HZ, 40 HP ,Type MU-G40 FASD, of make L&T, Sceinider or equivalent including taking out of old one complete all as specified and as directed by Engr-in-Charge.
M&L for fixing of DOL starter three phases 415 Volt for 2.5 HP electric motor including all fixing materials complete all as specified and as directed by Engr-in-Charge.
M&L for fixing of DOL starter three phases 415 Volt for 7.5 HP electric motor including all fixing materials complete all as specified and as directed by Engr-in-Charge.
M&L for fixing of DOL starter three phases 415 Volt for 10 HP electric motor including all fixing materials all as directed.
M&L for fixing of DOL starter three phases 415 Volt for 20 HP electric motor including all fixing materials complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, Flat three core submersible cable PVC insulated and sheathed multistranded copper conductor of cross sectional area 16 sqmm complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, FR PVC Insulated Single core unsheathed Industrial Flexible cable of size 16 sqmm conforming to IS 694:2010 with bright annealed copper conductor in existing panel including taking out of old one complete all as specified and as directed by Engr-in-Charge.
Supply only bleaching powder in 25 Kg bag (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply only sodium hypochloride liquid (chlorine content 10%) duly packed in sealed drum complete all as specified and as directed by Engr-in-Charge.
Supply only white crystal alum ferric of superior quality duly packed complete all as specified and as directed by Engr-in-Charge.
Supply only copper sulphate blue crystal of superior quality duly packed complete all as specified and as directed by Engr-in-Charge.
Supply only soda ash of superior quality complete all as specified and as directed by Engr-in-Charge.
Supply only Chlorine PPM comparator test Kit with colour indicators having 0.1 to 2.0 PPM with Resolution 0.01 pH complete all as specified and as directed by Engr-in-Charge.
Supply only Liquid O-Tolidine solution in sealed bottle of 50 ml complete all as specified and as directed by Engr-in-Charge.
Repair and maintenance of Granular Chlorination Reciprocating dosing pump (Model: 96 NGQ 51), high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD and adjustable high pressure of up to 100 PSI including minor spare parts such as tubing, connection nuts, injection check valve, clay weight, ferrules, water inlet pipe line, outlet with strainer,drain pipe, overflow pipe etc complete all as specified and directed by Engr-in-Charge.
Repair and maintenance of suction sweeper comprising 600mm long MS/ CI fabricated suction head with PVC wheels, spring loaded brush and fibber squeezer including trolley mounted electric driven non clog self priming type centrifugal pumping set with 02 HP Motor 03 phase , 415 V electric driven DOL Push button starter along with repair to minor defects such as repair/ replacement to electric contact, kit-kat fuse, pumping set gland rope, coupling nuts & bolts, bush/ thrust bearing of existing size , push button, contactor block & relay of starter ,oiling/ greasing and testing etc complete including painting with two coat of synthetic enamel paint of existing colour after removal of old paint / cleaning to rusted/ corrosive portion - 04 Sets complete all as specified and as directed by Engr-in-Charge. Note:- (i) All type of T&P main switch, electric multi meter/ tong tester for fault detecting, etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate. (ii) If item of work is not got executed for any of the suction sweeper-machine, price adjustment shall be made based on the proportional rate worked out from unit quoted rate for the item of work. (iii) Supply of major items required for repair/replacement shall be measured and paid for separately under relevant item of the BoQ at 'supply only rates.
Supply only Nylon-Rope size (14 -20) mm dia suction sweeper complete all as specified and as directed by Engr-in-Charge.
Supply only PVC suction hose / pipe, green (1-2" ultra Light & flexible with PVC spiral ribbed for extra strength) with 2 male connector nipplesplus clamps (4 Nos) complete all as specified and as directed by Engr-in-Charge.
S&F Spire Brush suitable for cleaning of swimming pool complete all as specified and as directed by Engr-in-Charge.
S&F PVC wheel with bush and nut bolt set of 04 Nos suitable for suction sweeper machine all as specified and directed by Engr-In-Charge
Collection of water samples of bore wells located in defferent pockets of cantonment area in decontaminated sterilised bottles and testing of water samples for the following essential parameters for drinking water as per IS:10500- 2012 from Govt Lab or NABL accredited laboratory all as specified and as directed: - (i) Colour (ii) odour (iii) taste (iv) pH value, (v) Turbidity (vi) TDS (vii) Total arsenic (viii) Silica (ix) Fluoride (x) Iron (xi) Magnesium (xii) Sulphate (xiii) Total Hardness (xiv) Total alkalinity (xv) Calcium (xvi) Conductivity (xvii) Chloride (xviii) Total Coliform and (xix) E Coli
Lifting of defective submersible pump set any make & model of capacity 25 HP to 45 HP from deep well 350mm housing along with connected accessories such as column pipe of 150mm dia appx 30 m, submersible cable, steel pipe, spider, sleeve, line shaft, nut, bolts etc complete all as specified and directed by Engr-In-Charge. Note:- (i) All type of T & P, chain pulley & tripod etc required at site will be arranged by the contractor and cost of the same shall be deemed included in the quoted rate. (ii) The Contractor will start the lifting work within minimum time after getting message verbally / telephonically by JE E/M/AGE E/M. (iii) A penalty of Rs. 500/- per day will be imposed on the Contractor for wilful delay by the Contractor as per opinion of Engineer-in-Charge and amount will be deducted from the due payment of the Contractor.
Transportation including loading & unloading of defective submersible pump set 3 phase of any make and of capacity 25 to 45 HP from pump house to work shop for necessary repair and transporting back to the pump house including carefully loading & unloading of pump set after repair complete all as specified and directed by Engr-In-Charge.
Dismantling of defective submersible pump set of any make & model of capacity 25 HP to 45 HP, repairing the same including replacing old unserviceable parts and re-assembling and testing after repair complete all as specified and directed by Engr-In-Charge. Note: (i) All the spares required for repair will be measured and paid for seperately at supply only rate. (ii) Greasing of moving parts deemed to be included in the quoted rate.
Supply only CI/ MS bowl (as per existing size) for submersible pump capacity 25 HP to 45 HP of any make & model complete all as specified and directed by Engr-in-Charge.
All as per Srl item No.122.00 here-in-before but Stainless steel shaft with key
All as per Srl item No.122.00 here-in-before but Gun Metal Bush
All as per Srl item No.122.00 here-in-before but Stainless steel sleeve
All as per Srl item No.122.00 here-in-before but Sand Guard
All as per Srl item No.122.00 here-in-before but Impeller lock with key
All as per Srl item No.122.00 here-in-before but Neck ring (as per existing size and type)
All as per Srl item No.122.00 here-in-before but Turning & polishing of Pump shaft (lathe work)
Supply only Stainless Steel thrust bearing parts for submersible motor of capacity 25 HP to 45 HP of any make & model complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No.130.00 here-in-before but Carbon plate.
All as per Srl item No.130.00 here-in-before but Rotor Gun Metal/steel bush
All as per Srl item No.130.00 here-in-before but Rubber bush
All as per Srl item No.130.00 here-in-before but Upper housing
All as per Srl item No.130.00 here-in-before but Lower Housing
All as per Srl item No.130.00 here-in-before but Turning, polishing of Rotor & shaft (Lathe work)
Rewinding of submersible motor of capacity 25 HP to 45 HP of any make & model with super enamelled copper wire of existing size including removal of existing burnt winding, cleaning of slots including packing material, connection and testing complete all as specified and as directed by Engr-in-Charge.
M&L for painting to pump set with two coats of synthetic enamel paint (grey colour) over a coat of red oxide primer after preparation of surfaces complete all as specified and directed by Engr-In-Charge.
Lowering, connecting, commissioning and testing of repaired submersible set of any make and of capacity 25 HP to 45 HP, 3 phase, 415V into bore well 300/200mm with connected items such as column pipe approx 40 RM, properly connecting submersible cable etc complete all as specified and directed by Engr-In-Charge. Note:- (i) All types of T&P, chain pulley & tripod etc required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate (ii) The Contractor will start the lifting work with in minimum time after getting message verbally/ telephonically by JE E/M/ AGE E/M. (iii) A penalty of Rs. 500/- per day will be imposed on the Contractor for wilful delay by the Contractor will be imposed as per opinion of Engineer-in-Charge and amount will be deducted from the due payment of the Contractor
Complete servicing of Fire fighting pump set any make & model of capacity 60 HP including replacement of minor spares and testing after servicing complete all as specified and directed by Engr-In-Charge. Note: (i) Greasing of moving parts deemed to be included in the quoted rate (ii) All types of T&P, main switch, electric multi meter/ tong tester for fault detecting etc required at site, will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Supply only rubber packing 6mm thick consisting of 8/6 holes for 100mm to 150 mm dia column pipe complete all as specified and directed by Engr-In-Charge.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 20 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling belt, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. Note: All types of T&P including dismantling and fixing required at site will be arranged by the contractor and cost of the same deemed to be included in the quoted rate.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 10 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. Note: All types of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 7.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing complete all as specified and directed by Engr-In-Charge. Note: All types of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity upto 2.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. Note: All types of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Taking out 20mm dia bore steel / uPVC water tubing including all fittings and fixtures complete all as specified and directed.
S&F 20mm dia bore uPVC pipe ISI Marked best quality, fixed to walls, ceilings or laid in floors etc complete all as specified and directed.
Complete servicing of servo voltage stabilizer of 50 KVA of make: Servostar / Vinitec or any other make as per site requirement and connected accessories including replacement of defected old parts, oil / lubricant to keep the plant in running condition including routine maintenance complete all as specified and as directed. Note: (i) The Contractor need to get the job done through authorised service centre/ agency of OEM (Original Equipment Manufacturer).The cost thereof deemed to be included in the quoted rate. (ii) All spare parts for routine maintenence will be measured and paid for separately under relevent items of the BoQ at 'Supply Only' rates. (iii) Labour charges for routine maintenance including properly dismantling of old parts deemed to be included in the quoted rate.
Supply only Variac for routine maintenance of servo voltage stabilizer 50 KVA capacity complete all as specified and as directed by Engr-in-Charge.
All as per item no.149 but servo motors (3 Kg)
All as per Srl item No.149 here-in-before but RC Network (3 Kg)
All as per Srl item No.149 here-in-before but Sensor Transformer 8/16V (Triggar)
All as per Srl item No.149 here-in-before but 2 K Pot
All as per Srl item No.149 here-in-before but PCB Digital Card (Double Display)
All as per Srl item No.149 here-in-before but Carbon Brush
All as per Srl item No.149 here-in-before but Voltmeter
All as per Srl item No.149 here-in-before but Micro Switch
All as per Srl item No.149 here-in-before but SPDT & DPDT Switches
All as per Srl item No.149 here-in-before but Buck Boost Transformer
All as per Srl item No.149 here-in-before but Motorised Plate
All as per Srl item No.149 here-in-before but Front Plate Variac
All as per Srl item No.149 here-in-before but Armer of Variac
All as per Srl item No.149 here-in-before but Variac Base
All as per Srl item No.149 here-in-before but Strip 30 Amp
All as per Srl item No.149 here-in-before but Spring
All as per Srl item No.149 here-in-before but Hexa
All as per Srl item No.149 here-in-before but Stopper
All as per Srl item No.149 here-in-before but Relay 5 Amp
All as per Srl item No.149 here-in-before but Push Button
All as per Srl item No.149 here-in-before LED (Green,Yellow,Red)
All as per Srl item No.149 here-in-before PCB Card (High & Low Cut Off)
All as per Srl item No.149 here-in-before Transformer Oil
Disconnecting electrically incomming and outgoing LT UG cable of LT panel of any size and replace burn/unsv suitable size of aluminium bus bar, Welding work for hinches and doors, fixing the locking arrangement including scraping outdoor/indoor side of LT Panel and one coat of redoxide, two coat of synthetic enamelled seimens gray spray of outdoor/Indoor side and reconnecting LT UG cable with fixing aluminium lugs by using crimping tool, nut, bolt washer etc and all necesary work required for smooth functioning of LT panel complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of old existing self reflector type flexi board with PVC frame of size 1.2mx0.8m including diagram of water disribution network at each pump house complete all as specified and directed by Engr-in-Charge.
M&L for steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed by Engr-in-Charge.
S&F mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screws including bending and welding angles as necessary, gusset plates, riveting etc, n.exc 10 Kg each bracket, conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engr-in-Charge.
S&F in repairs, Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 500 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge.
S&F in repairs, Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550 mpa as in ridge of roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge.
M&L for 2 coats of synthetic enemel paint to steel surfaces of any description, not exc 10cm width or girth when unconnected with other painting or when painted in a different tint over over a coat of red oxide primer including preperation of new steel surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for repairing the damaged portions of RCC columns on top of roof of pump house building for lifting & lowering of submersible motor pump by chipping / removing damaged / peeled off concrete, cleaning the surfaces to remove all loose particles, applying a coat of neat cement slurry and making good the surfaces with cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) with fair finished surfaces and applying two coats of cement base paint on complete surfaces of columns including preparing old surfaces of ISMBs and applying two coats of black synthetic enemal paint complete all as specified and directed by Engr-in-Charge.
M&L for dismatling existing rusted cradle for hanging fire fighting hose reel box and providing new cradle made of angle iron 50x50x5mm in invert 'U' shape, (total length of angle 5.00m) including cutting, jointing & welding etc complete. The vertical legs shall be provided/welded with 300mm long FI 50 x 5 mm at bottom and shall be embeded in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) with & including excavation in post holes of size 450x450x450mm and the balnace angle shall be welded on top of vertical legs with provision of suitable numbers of 10mm dia MS plain bar hooks for hanging Hose Reel Box of fire fighting system. The length of legs & horizontal portion shall be decided by the Engr-in-Charge. The complete cradle including existing hose box shall be painted with two coats of red synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Khan Brothers
Charan sales and Service
Super Automobiles
M/S AVADH ENTERPRISES
Puma Power
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .