Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 CrAdmitted-Finance | ₹25.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹26.6 CrAdmitted-Finance | ₹26.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹27.3 CrAdmitted-Finance | ₹27.3 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | PARKER CONSTRUCTIONS L1 | Yumkham Subhaschandra Meetei L3 | Irom Khogen Singh L2 |
|---|---|---|---|---|---|---|
| 1.00SH-A: INA HERITAGE HOME | ||||||
| 2.00Earth Work | ||||||
| 3.00 | Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m | 243.71 | Cum | 150 ₹36,556.50 | 180.4 ₹43,965.28 | 175.7 ₹42,819.85 |
| 4.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre. | 73.11 | Cum | 122 ₹8,919.42 | 143.6 ₹10,498.60 | 139.9 ₹10,228.09 |
| 5.00 | Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm | 104.11 | Cum | 1,800 ₹1.9 L | 1,893.1 ₹2.0 L | 1,843.7 ₹1.9 L |
| 6.00Concrete Work | ||||||
| 7.00 | Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size). | 85.84 | Cum | 10,610 ₹9.1 L | 11,175.1 ₹9.6 L | 10,883.6 ₹9.3 L |
| 8.00RCC Works | ||||||
| 9.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.) | 96.8 | Cum | 16,672 ₹16.1 L | 17,752.8 ₹17.2 L | 17,289.7 ₹16.7 L |
| 10.00 | Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications | 53 | Each | 1,87,448 ₹99.3 L | 1,97,767.2 ₹1.0 Cr | 1,92,608.1 ₹1.0 Cr |
Tender Value
₹19.0 Cr
EMD Value
₹37.9 L
Closing Date
20 Dec 2021, 12:00 pmClosed
Executive Engineer-II
MPHC Office Complex, Imphal
Development of Heritage Site for INA Head Quarter at Moirang, Bishnupur District, Manipur
2021_MPHCL_1701_1
10/EE-II/MPHC/2021-22
Open Tender
Civil Works
180 days
As per tender document
Please refer Tender documents.
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd.
₹37.9 L
Yes
27 Jul 2023
8 Dec 2021
20 Dec 2021
8 Dec 2021
20 Dec 2021
10 Dec 2021
9 Dec 2021 - 18 Dec 2021
Amount
SH-A: INA HERITAGE HOME
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply) (a) Foundation footings, bases of columns etc. and mass concrete.
Masonary Work
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Steel Work
Supply & erection of Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Flooring Work
Granite Stone slab flooring over 20 mm ( Average) thick base of cement mortar 1: 6 laid and jointed with grey cement slurry including rubbing and polishing complte with(i)Granite slab of 20mm thick(a)Jade Black ( 60 cmX 120cm)
Roofing Works
Supply & Installation of standing seam polycarbonate panels of 22mm thick with all accessories e.g. polycarbonate connector, HDSS fastener, screw, Aluminium U-Profile etc to fix the panels on the top of the MS supporting structure. The panels system shall have min width of 1050 – 1200mm c/c. Panel system will be fixed on the top of supporting structure in such a way that the system will ensure a pull-out load of min 7KN tested as per ISO 6892:1998 and IS 1608:2005. Panels shall have angular daylighting concept in translucent clear and opaque walls in two colours in single panel. The panels system will achieve required lux levels with improved variable daylighting and shading throughout the day for improved ambient temperature beneath the roof. Panel shall have minimum 7 layers. Panels shall pass dart drop impact test as per IS 14443 – 97 and shall show no sign of breakage if panels are exposed to UV for a minimum 500hrs as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM 1925 of 15 units when tested on a sample exposed to UV for 500 hours as per ASTM G 155. U value shall not be more than 1.7 W/m2kas per EN ISO 10077-2:2018
Finishing Works
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Miscelleneous Works
Repariring & Restoration of old INA Head Quarter Building
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Hoticultural Works
(SH: Providing IEI in the INA Heritage Home (Head Quarter)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F fancy wall bracket suitable for 1X9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F 12W LED bulb.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
Supply & installation of Dry Powder (Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity : 4 kg (ISI marked).
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-B: FLAG MAST
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRTE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
Miscelleneous
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Design, supply, installation & commissioning of 50 Mtr. (165 feet) High National Flag Mast
165 Ft Flag Mast made up of HT Steel Sheet in 3 sections complete with motorised raising lowering system for flag of size 40ftx35ft with motorised operation. The Flag mast shall be galvanised and PU painted in White Color and includes all the accessories. It also includes FRP Decorative Dome on top of the Flag Mast. Provisioning of manual operation of hoisting and lowering of flag by manual handling along with gear box system.
Foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.
LED Aviation Light
06 Mtr high hot dip galvenised Octagonal pole suitable to mount 1 nos LED Flood Light fitting at top with suitable mounting arrangements at bottom.
Foundation bolts for 06 Mtr Pole manufactured from special steel along with nuts, washers, anchor plate and common template
Narrow beam LED Flood Light Luminaries type 350W along with suitable arrangements and supports for mounting luminaries on flag
National Flag of size 40ft x 35 ft in 100% Knitted Polyester (140 gsm) with reinforced super-strong nylon webbing on all 3 side & rope/toggle sleeve.
SH-C: INA MONUMENT
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRTE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
Miscellneous Work
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Granite Stone slab flooring over 20 mm ( Average) thick base of cement mortar 1: 6 laid and jointed with grey cement slurry including rubbing and polishing complte with(i)Granite slab of 20mm thick(a)Jade Black ( 60 cmX 120cm)
Curving the Lettrs in the Mounment as per the instruction of Engineer-in-charge
(SH: Providing IEI in the INA Monument)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's JETACOMPECT OF 50W LED 757LTG complete with connection as rqd. (Havell's)
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-D: SECURITY BOOTH
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
Masonary Work
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure (1) above plinth level upto 1st floor level.
Wood & PVC Works
Providing and fixing factory made uPVC teak Wood colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking
Providing and fixing factory made uPVC Teak colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Flooring Works
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Roofing Works
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to (i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-tapered and backed by acoustical tissue with NRC value not less than 0.60.charge and as per manufacturer's specification, with all 4 side
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Finishing
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Miscelleneous
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing 12mm thick HPL Board
(SH: Providing IEI in the Security Booth)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
Supply & installation of Dry Powder (Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity : 4 kg (ISI marked).
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-E: EASTERN FENCING WITH PLANTER BOX
EARTH WORK
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Work
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
Masonary Works
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure (1) above plinth level upto 1st floor level.
Flooring Work
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Providing & Fixing Ornmental Baluster of solid Granite of 600mmX600mmX1500mm
Steel work
Providing & fixing M.S. grills of required pattern to wooden frames of window etc with M.S. flats at required spacing & frames all round bars with round headed bolts & nuts or by screws. (a) Ornamental grill.
(b)Provivding & Fixing 25 X 25 mm.Sq Cast iron Arrow of the length of 30cm on the top of verticle bars (at alternate space)
Miscelleneous
Supply & Fixing of Ornmental Gates as per the the Design Approved & Directed by Engineer in charge
Supply & Fixing of the Brass Signages as per the drawing ,as directed by Engineer in charge
SH-F: LIBRARY & SOUVENIOUR SHOP
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
Masonary Work
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure (1) above plinth level upto 1st floor level.
Wood & PVC Works
Providing and fixing factory made uPVC teak Wood colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking
Providing and fixing factory made uPVC Teak colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Flooring Work
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Roofing Works
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to (i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-tapered and backed by acoustical tissue with NRC value not less than 0.60.charge and as per manufacturer's specification, with all 4 side
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
Finishing Works
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Miscelleneous
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing 12mm thick HPL Board
(SH: Providing IEI in the Library cum Souvenir Shop)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
Supply & installation of Dry Powder (Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity : 4 kg (ISI marked).
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH G: TICKET COUNTER & SECURITY CABIN
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
Masonary Work
2nd class (local first class) brick work in superstructure in cement mortar 1:3 (1 Cem: 3 Kanhaighat C/Sand) (a) above plinth level upto 1st floor level
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure (1) above plinth level upto 1st floor level.
Wood & PVC Works
Providing and fixing factory made uPVC teak Wood colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking
Providing and fixing factory made uPVC Teak colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Flooring Work
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Roofing Works
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to (i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-tapered and backed by acoustical tissue with NRC value not less than 0.60.charge and as per manufacturer's specification, with all 4 side
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
Finishing Works
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Miscelleneous
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing 12mm thick HPL Board
(SH: Providing IEI in the Ticket Counter with Security Cabin)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
Supply & installation of Dry Powder (Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity : 4 kg (ISI marked).
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-H : CAFÉ & TOILET
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d ) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(f) Edges of slab and breaks in floors and walls (i) Under 20cm wide
Masonary Work
2nd class (local first class) brick work in superstructure in cement mortar 1:3 (1 Cem: 3 Kanhaighat C/Sand) (a) above plinth level upto 1st floor level
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure (1) above plinth level upto 1st floor level.
Wood & PVC Works
Providing and fixing factory made uPVC teak Wood colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking
Providing and fixing factory made uPVC teak Wood colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking
Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Flooring Work
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Roofing Works
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to (i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-tapered and backed by acoustical tissue with NRC value not less than 0.60.charge and as per manufacturer's specification, with all 4 side
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Finishing Works
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Miscelleneous
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing 12mm thick HPL( High pressed Laminate ) Board
SEPTIC TANK
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:3:6 (1 cement :3 Kanaighat coarse sand :6 graded stone aggrt. 40mm nominal size).
(b) C.C. 1:2:4 (1 cement :2 Kanaighat coarse sand :4 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
(b) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
(d ) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanaighat coarse sand) in superstructure.
15 mm cement plaster 1:3(1 cement:3 Kanaighat coarse sand)finished with a floating coat of neat cement.
(SH: Providing IEI in theToilet and Cafe)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
© 2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F fancy wall bracket suitable for 1X9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
Providing and fixings (following capacity TP & N) dis-connector fuse switch unit inside the existing cubicle panel with ISI marks HRC fuses including frilling holes in the cubicle panel board, making connection as reqd. 100 amp. TP & N.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
Supply & installation of Dry Powder (Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity : 4 kg (ISI marked).
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH-I : POOL WATER BODY & BRIDGE
EARTH WORK
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
Flooring Work
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
SH - J : WEST LANDSCAPE WITH PLANTER BOX
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
SH - K : PAVING AREA
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
Providing and laying 60 mm thick factory made cement concrete interlocking paver block (Rubber Moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the Engineer-in-charge.
SH-L : BOUNDARY FENCING
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Work
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
Masonary Works
2nd class (local first class) brick work in superstructure in cement mortar 1:3 (1 Cem: 3 Kanhaighat C/Sand) (a) above plinth level upto 1st floor level
Steel work
Providing & fixing M.S. grills of required pattern to Compund wall etc with M.S. flats at required spacing & frames all round bars with round headed bolts & nuts or by screws. (a) Ornamental grill.
(b)Provivding & Fixing 25 X 25 mm.Sq Cast iron Arrow of the length of 30cm on the top of verticle bars (at alternate space)
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
Flooring Works
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Roofing Worksork
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Finishing Works
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Supply & Fixing of Ornmental Gates as per the the Design Approved & Directed by Engineer in charge
(SH: Providing External Compound Lighting)
S/F bollard with 9/2.5w square shape integral decorative LED bollard with polycarbonate diffuser and IP65 protection i/c connection etc. as reqd.
SITC 35 watt LED 730 PSYMTOPC VICTORIA IP/65 for out door post top lantern and GI pole dia. 76mm standard colour i/c painting etc. as reqd. (Havells).
S/F LED FLEXI STRIP Light 5 mt. long i/c driver 24 volt 2 amp. Etc. as reqd. (Havells).
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
(SH: Installation of DG set & LT Panel Board)
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of four way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 200 amp. TPN on load changeover switch - 1 No.
2. 200 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
P/L 50mm2 four core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
(SH: Installation of Solar Street lamp)
Solar LED street lamp All-In-One with in built SCC system wattage of 30 W of make Crompton Greaves Ltd.code no CSADEMP25/30CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel
(SH: Providing IEI in the Community Hall)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F 12W LED bulb.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH: Foot Path Solar Lighting)
Solar LED street lamp All-In-One with in built SCC system wattage of 30 W of make Crompton Greaves Ltd.code no CSADEMP25/30CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel
(SH: Installation of Water Fountain)
Supply/Installation of premier finger and columner jet fountain 3 nos. F-nozzles 4 nos. C-nozzels with 3 HP submersible/floating electric pumpset i/c 7x3 nos. 150W lamps colour glass gasket light stand cable standard panel board fuse internal wiring and outdoor electrical enclosure necessary boards as reqd.
SH-M : ROAD AND DRAIN WORKS
Providing laying & compacting granular base/sub-base according to lines, grades& cross-sections by using naturally occurring sand gravel/conforming to IRC Grade 2 of M.O.S.T. specification free from organic or other deleterious constituents compact by rolling with power roller of 8 to10 tonnes capacity in layers not exceeding 150 mm (spread thickness)including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge. ( without carriage charge of all materials)
Providing ,laying, spreading and copacting graded stone to wet maccadam specification premining the material with Water at OMCin the machanical mix ( plug Mill) carriageof mixed by tipper to site laying uniform layers in sub -base /base cource on well preparedunderbase and compacting with power vibrator-rollerachived deserived density including lighting,guiding
Preparing surface by brushing with wire brushes for remaining caked mud etc. sweeping with brooms and finally fanning the cleared surface with gunny bags to removed all loose dirt etc.
Surface dressing one coat with bitumen (80/100) using 18 kg of bitumen per sqm with 0.15 cum of stone aggregate 12 mm nominal size per 10 sqm of road surface & rolling complete.
Providing and laying bituminous macadam of 50 mm as per clause 504.1 of "MOST" specification for base course with binder content @ 4% by weight of total mix including preparation of bases including filling of pot holes, cleaning the surface with wire brushes etc. and providing suitable edge supports heating of binder and aggregate handling of materials, screening, mixing, in hot mix plant conforming and transporting laying and finishing with paver finisher to the required level, grade and camber, rolling by power roller etc. complete including running expenses of all plants.
2 cm consolidated thick single coat pre-mix carpet surfacing with 0.27 cum stone chipping 12.0 mm size 0.19 cum and 10 mm size 0.09 cum mix with 14.6 kg of binder per 10.00 sqm of road surface and rolling complete including a seal coat IRC type "B" with 0.06 cum of fine aggregate and 6.8 kg of bitumen 80/100 per 10.00 sqm of road surface using H.M. plant & paver finisher.
Drain Works
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
SH - N : POND DEVELOPMENT.
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Work
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
Steel work
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint .(i) In staircase i/c stringers,treads,landings, handrail and the like.
Providing and fixing 4 mm G.I Wire netting 10cm. Square /diagonal mesh walling.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block (Rubber Moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the Engineer-in-charge.
Hoticluture Works
SH - O : PARKING AREA
Earth Work
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in Plinth as well as excavated portion of footings and under floors with sand gravel including watering ramming,consoilding and dressing complete with a lead of 29Km of folloing sizes a)40mm
Concrete Work
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 20mm nominal size).
RCC Work
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 18.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
Steel work
Providing & fixing M.S. grills of required pattern to wooden frames of window etc with M.S. flats at required spacing & frames all round bars with round headed bolts & nuts or by screws. (a) Ornamental grill.
(b)Provivding & Fixing 25 X 25 mm.Sq Cast iron Arrow of the length of 30cm on the top of verticle bars (at alternate space)
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
SH - P WELCOME GATE AND EXIT GATE TO MAIN DOOR
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanaighat coarse sand :8 graded stone aggrt. 40mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with length of 18.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
(b) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
b) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttresses, plinth and the string courses and the like
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand:) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Kanglasha Statue
SH-Q : GAZEBO IN POND AREA
Earth work
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.(i) loose/soft soil (a) Lift upto 1.5m
Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 km
Concrete Works
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand :8 graded stone aggrt. 40mm nominal size).
RCC Works
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing Cast-in-situ reinforced cement concrete piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with two under reamer and of length 21.0m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
Form Work
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a) Foundation footings, bases of columns etc. and mass concrete.
Flooring Work
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Irom Khogen Singh
Yumkham Subhaschandra Meetei
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Documents.pdf
Tender Documents • 2.35 MB
Drawing.pdf
Additional Documents • 11.00 MB
BOQ_1873.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid