Loading…
Loading…
Tender Value
₹3.4 Cr
EMD Value
₹6.9 L
Closing Date
5 Oct 2026, 1:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
NIT
15 conditions · 4 needing a document upload
As per PREAMBLE CLAUSE No. 11.2 of Tender Document:- The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
ELECTRICAL CONTRACTORS LICENSE:- The contractor shall fulfill valid Electrical Contractor License requirement as per IE Rule 1956 clause no- 45. Electrical Contractors license shall be submitted along with the offer, failing which the offer will summarily be rejected.
Technical Eligibility Criteria: As per clause 11.1 of Preamble and Scope of Work of uploaded tender document Page no. 4 & 6.
SIMILAR NATURE OF WORK: The contractor should have executed, "Electrification / Rewiring of Service or Residential building/Yard / HT/LT Substation work / HT/LT cable work / Street lighting / Platform or building lighting management / circulating area Lighting/ Electrical overhead power supply work / Electrical pump work etc."
23 conditions · 9 needing a document upload
All the supporting DOCUMENT(S)/CERTIFICATE(S) of as a proof Technical and Financial credentials as detailed in this tender Document, has/have been attached.
Supporting DOCUMENTS/CERTIFICATES as detailed in this Tender Document has been attached.
The Bid Security shall be deposited either in cash through epayment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids. (i.e. excluding the last date of submission of bids.) (See clause 1.10 of Chapter-I of Tender Document)
All the bidders / tenders should ensure that they are GST compliant and their quoted tax structure / rates are as per GST Law. (Copy of GST registration certificate)
Copy of PAN CARD
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rewiring of staff quarters and improvement of staircase and street lighting arrangement at various colonies of Mumbai Division.
BB-LG-W-CLA-2026-01~CR
BB-LG-W-CLA-2026-01
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹6.9 L
11 Sept 2026
11 Sept 2026
21 Sept 2026
81 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,44,37,318.51 | ||
| — | Breakup for | details. | — | ||
| (1) Supply, installation, testing, and commissioning of 18-20 Watt, 4-feet slim LED batten fitting with high-lumen output, inbuilt driver, glare-free diffuser, and extruded aluminium housing, including aluminium framing, wiring, and connections as per site requirements, complete in all respects. | — | — | — | 34,97,652 | |
| — | Breakup for | details. | — | ||
| (2) Supply, erection, testing and commissioning of 9-10 W LED (2 ft) slim fitting complete with fixing arrangement, etc. | — | — | — | 3,80,600 | |
| — | Breakup for | details. | — | ||
| (3) Supply, erection, testing and commissioning of 85-90W LED outdoor lighting fitting complete with all fixing arrangements. | — | — | — | 8,72,698.5 | |
| — | Breakup for | details. | — | ||
| (4) Supply, erection, testing and commissioning of 10 Watts LED bulkhead fitting complete with connections. | — | — | — | 2,27,877 | |
| — | Breakup for | details. | — | ||
| (5) Supply, erection, testing & commissioning of LED Bollard 8-10 W fitting complete with connection and necessary fixing arrangements as per site requirement. | — | — | — | 5,15,703 | |
| — | Breakup for | details. | — | ||
| (6) Supply, erection, testing and commissioning of 48" sweep energy efficient BLDC ceiling fan with down rod, motor, etc. with necessary connection. | — | — | — | 83,66,865 | |
| — | Breakup for | details. | — | ||
| (7) Supply, erection, testing and commissioning of 10" fiber body type exhaust fan complete with motor guard, cover, etc. | — | — | — | 8,50,500 | |
| — | Breakup for | details. | — | ||
| (8) Supply, erection, testing and commissioning of 6 litre geyser with complete with connection and necessary fixing arrangements as per site requirement. | — | — | — | 3,05,525 | |
| — | Breakup for | details. | — | ||
| (9) Wiring of the concealed Light / fan / call bell point with all accessories. The switches shall be of modular type. | — | — | — | 49,32,700 | |
| — | Breakup for | details. | — | ||
| (10) Wiring of Universal plug point on switch board with all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 2,53,725 | |
| — | Breakup for | details. | — | ||
| (11) Wiring of the concealed Universal plug point (2 plug & 2 switch on separate board) with all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type | — | — | — | 6,32,904 | |
| — | Breakup for | details. | — | ||
| (12) Wiring of concealed 15 Amps wall socket point complete on separate switch board with all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 3,03,352 | |
| — | Breakup for | details. | — | ||
| (13) Wiring of concealed 15 Amps wall socket point complete on separate switch board with 20 Amp DP MCB & all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 4,20,792 | |
| — | Breakup for | details. | — | ||
| (14) Stair case wiring of single core multistranded PVC insulated 1.1 KV grade copper conductor of size not less than 2.5 Sq.mm along with running earthing of one wire of 2.5 sq.mm copper conductor of green colour connected to metallic points in rigid PVC casing caping / PVC conduit pipe of 19 mm size 1.2 mm thick (heavy duty). The PVC conduit pipe shall be fire retardant confirming to relevant ISS. | — | — | — | 1,53,632 | |
| — | Breakup for | details. | — | ||
| (15) Wiring of the light / fan / call bell point with all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 8,91,040 | |
| — | Breakup for | details. | — | ||
| (16) Wiring of the Universal plug point (2 plug & 2 switch on separate board) in PVC casing / capping. The switches shall be of modular type. | — | — | — | 62,966 | |
| — | Breakup for | details. | — | ||
| (17) Wiring of the Universal plug point (4 plug & 4 switch on separate board) in PVC casing / capping. The switches shall be of modular type. | — | — | — | 1,09,129 | |
| — | Breakup for | details. | — | ||
| (18) Wiring for 15 amps plug point wiring with switch (Universal type) on separate switch board complete with plug and socket. The wiring shall be of copper PVC insulated, 1.1 KV multistranded wire on rigid PVC casing caping with all accessories & running earthing with sub mains on separate PVC switch board. | — | — | — | 59,279 | |
| — | Breakup for | details. | — | ||
| (19) Wiring of 15 Amps wall socket point complete with fuse, indicator, etc. with DP MCB and running earthing as per standard practice on separate board. The switches shall be of modular type. | — | — | — | 71,010 | |
| — | Breakup for | details. | — | ||
| (20) Supply, laying, running fixing of following sizes of XLPE insulated, PVC sheathed, 1.1 KV grade cables as per IS. (a) 4 core 16 sq.mm AL conductor armoured(b) 4 core 10 sq.mm AL conductor armoured(c) 3 core 10 sq.mm CU conductor armoured(d) 3 core 6 sq.mm CU conductor, armoured | — | — | — | 36,11,860 | |
| — | Breakup for | details. | — | ||
| (21) Excavation of cable trench in soil & filling the trench with sand, pebbles etc. after laying of the cable complete with RCC warning cover & cable markers, sand etc. as per railways requirement | — | — | — | 1,43,300 | |
| — | Breakup for | details. | — | ||
| (22) Excavation of cable trench on CC flooring / Hard / rocky soil & making of trench & recasting of flooring/pit after lying of cable as per railways requirement. | — | — | — | 2,76,680 | |
| — | Breakup for | details. | — | ||
| (23) Supply, erection, testing and commissioning of 4 way thermoplastic poly carbonate junction box with 4 way 20A Connector as per Railway's requirement. | — | — | — | 4,66,631 | |
| — | Breakup for | details. | — | ||
| (24) Supply, Installation, Testing and Commissioning of High Hot dip galvanized octagonal pole with longitudinal seam weld throughout the length complete with one arm for fitting installation and J type foundation bolt set complete in all respect with RCC foundation. | — | — | — | 5,92,825.2 | |
| — | Breakup for | details. | — | ||
| (25) Supply, fixing, testing and commissioning of buzzer/bell. | — | — | — | 14,422.5 | |
| — | Breakup for | details. | — | ||
| (26) Supply, fixing, testing and commissioning of 1 way 5/6A modular SP switch | — | — | — | 18,100 | |
| — | Breakup for | details. | — | ||
| (27) Supply, fixing, testing and commissioning of 2 way universal modular type SP switch | — | — | — | 26,824 | |
| — | Breakup for | details. | — | ||
| (28) Supply, fixing, testing and commissioning of universal modular multi pin socket with separate 5/6A switch | — | — | — | 32,644 | |
| — | Breakup for | details. | — | ||
| (29) Supply, fixing, testing and commissioning of 16A modular type multi pin socket with separate 16A SP switch. | — | — | — | 51,753 | |
| — | Breakup for | details. | — | ||
| (30) Supply, fixing, testing and commissioning of surface mounted /flush type power unit complete with 4 modular plates, 25 A MCB, starter, plug & socket for AC | — | — | — | 58,928 | |
| — | Breakup for | details. | — | ||
| (31) Supplying, erecting & commissioning 2 pole RCBO 6 A, with added immunity to avoid DC pulse tripping with complete as per specification | — | — | — | 4,48,330 | |
| — | Breakup for | details. | — | ||
| (32) Supplying, erecting & commissioning 2 pole RCBO 10/16 A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification | — | — | — | 3,17,900 | |
| — | Breakup for | details. | — | ||
| (33) Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 3,37,100 | |
| — | Breakup for | details. | — | ||
| (Thirty Four) Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification. | — | — | — | 2,14,700 | |
| — | Breakup for | details. | — | ||
| (35) Supplying, erecting, testing and commissioning of double door SDB panel with incoming 4P 63 A MCCB, and for outgoing 10 x32 A DP RCBO, 10 x 16 A DP MCB and other accessories complete | — | — | — | 12,35,436.25 | |
| — | Breakup for | details. | — | ||
| (36) Supply, erection, testing and commissioning of Lighting Circuit Board, Double Door Powder coated with locking arrangement consisting 32 A DP RCBO as I/C and 6 Nos x 6A SP MCB and 2 Nos x 20A SP MCB O/G Complete | — | — | — | 28,88,742 | |
| — | Breakup for | details. | — | ||
| (37) Supply, erection, testing and commissioning of maintenance free earthing | — | — | — | 2,44,417 | |
| — | Breakup for | details. | — | ||
| (Thirty Eight) Supply & erection of earthing G.I. pipe with cement concrete earth chamber, charcoal, salt, etc. | — | — | — | 1,58,019 | |
| — | Breakup for | details. | — | ||
| (Thirty Nine) Supply, erection, testing and commissioning of GI strip of 25 mm x 3 mm | — | — | — | 1,77,640.26 | |
| — | Breakup for | details. | — | ||
| (40) Supply, erection, testing and commissioning of new meter board box made of Teak Wood / MS board. Sun mica board as per site condition and railway's requirement | — | — | — | 2,13,116.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderBookofrewiringofqtrs.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCACS1to12.pdf
ATTACHMENT
SpecificationBLDCceilingfan.pdf
ATTACHMENT
SpecificationEarthingRDSOSPN197Ver1.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .