Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-Finance ok | |
| 2 | L2₹23.8 L+₹1.2 L (5.37%)Rejected-Finance CHHOTOBAZAR MIDNAPORE PASCHIM MEDINIPUR 721101 | MIDNAPORE | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹26.3 L+₹3.7 L (16.6%)Rejected-Finance DHARSHA NEAR MATH P O GIP COLONY DIST HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹26.8 L+₹4.2 L (18.7%)Rejected-Finance HABIBPUR KOTWALI PASCHIM MEDINIPUR 721101 | KOTWALI | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹27.5 L+₹4.9 L (21.9%)Rejected-Finance 22 GROUND FLOOR POTTERY ROAD TANGRA KOLKATA WEST BENGAL 700015 | KOLKATA | WEST BENGAL | 700015 | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
7 Feb 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Paschim Med. Elecl. Div. PWDte
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte. Paschim Medinipur
Electrical Installation work for proposed 24 beded hybrid CCU at Ghatal Sub-Divisional Hospital, Paschim Medinipur.---- E.I. Work. (2nd Re-Tender)
2021_WBPWD_351309_3
WBPWD/EE/PMED/NIQ-30/e-Q /2021-2022
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Ghatal, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹56,000
9 Feb 2022
17 Jan 2022
9 Feb 2022
17 Jan 2022
7 Feb 2022
17 Jan 2022
120 days
Amount
Dismantling the existing wiring with all allied accessories carefully & providing temporary arrangement not to hampering other portion of building and mending good damages to building works as par direction of E.I.C
Supply, installation, testing & commissioning of cubical type panel board with separate compartmentalized floor mounted, indoor type dust and vermin proof powder coated panel board, suitable for 415V 3phase, 4wire,50Hz, A.C supply of suitable size made out of 14 SWG (2mm.) thick CRCA/M.S. sheet wih angle (50X50X6 mm) , flat ( 50 X 6 mm) structure with individually hinged capsule door for all compartment with lock ,providing ventilation arrangement & free standing from floor mounting . The control panel should have suitable cable entry from bottom of back through detachable gland plate (100mm.x40mm.x4mm.) thick M.S. channel to access sufficient no of incoming & outgoing cable Incl. suitable size G.I. net guard with key & locking arrengement with interconnection with adequate size cu. wire, copper bar, cu link, cable connector etc. along with necy. nuts, bolts, clamps, grouting bolts incl. providing and fixing the following accessories etc. complete as required. (Make : L&T/ ABB/ Schneider) Incoming:- a) S & F 415A, 250V TPN Switch disconnector fuse unit open execution type with 3 Nos din type HRC fuse link--1 nos. b) S & F 415A, 250V TPN onload change over switch open execution type --1 nos. Busbar :- S & F 415 V, 315 A current carrying capacity electrolytic grade tinned copper BBC of size having bus bar dimension of (4 x 40 mm x 5mm)) will be fixed on FRP Chair & the entire bars are insulated with PVC heat sinkable sleeves with suitable size & colour as per.
Outgoing Switch Fuse Unit: a) S & F 125A, 415V TPN Switch disconnector fuse unit open execution type with 3 Nos din type HRC fuse link--6 nos. b) S & F 63A, 415V TPN Switch disconnector fuse unit open execution type with 3 Nos din type HRC fuse link--6 nos.
Supply & Laying of following size 1.1kv grde xlpe insulated Al/armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. (Make- Policab/ Haveels/ Gloster/ KEI)
a) 4 Core 95 sqmm XLPE armoured cable
Supplying & fixing following medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
a) 80 mm dia
b) 100 mm dia
S&F of cement concreat make 1.5' length "T" -- shape cable rout indicator having "440V P.W.D." indicator for cable rout indication.
S & Laying of following size 1.1kv grde xlpe insulated Al/armoured cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Make- Policab/ Haveels/ Gloster/ KEI)
a) 4 Core 95sqmm XLPE armoured cables
b) 4 Core 50sqmm XLPE armoured cables
S & Laying of following size 1.1kv grde xlpe insulated Al/armoured cable as below, on existing Cable Tray and binding with 2 x 10 SWG GI (Hot Dip) Wire (Make- Policab/ Haveels/ Gloster/ KEI)
a) 4 Core50 sqmm XLPE armoured cable
b) 4 Core35 sqmm XLPE armoured cable
c) 4 Core25 sqmm XLPE armoured cable
Supply & Laying of following size 1.1kv grde xlpe insulated Al/armoured after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average 75 mm/100mm depth as below and mending good the damages to original finish incl. removing the rubbish. (Make- Policab/ Haveels/ Gloster/ KEI)
a) 4 Core35 sqmm XLPE armoured cable
b) 4 Core25 sqmm XLPE armoured cable
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of 200x50x1.25mm (18SWG) size. Incl. Al painting of 25x25x3mm angle iron support.
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the 200x50x1.25mm (18SWG) size. Incl. Al painting of MS support.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of following size
a) 4 Core 95sqmm cable
b) 4 Core 50sqmm cable
c) 4 Core 35 sqmm cables
d) 4 Core 25 sqmm cable
Finishing the end of following cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
a) 4 Core 95sqmm cable
b) 4 Core 50sqmm cable
c) 4 Core 35 sqmm cables
d) 4 Core 25 sqmm cable
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 8way, Enclosure with s & f Four Pole 125A, 25/35 KA, FP MCCB as incoming and 8nos 415 V 63A TPNMCB as outgoing of Breaking capacity 10kA & C characteristics as outgoing incl. 2 no. cable end box. (Make- Siemens (8GB31573RC)/ Legrand/ Schneider)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 4way, Enclosure with s & f Four Pole 125A, 25/35 KA, FP MCCB as incoming and 4nos 415 V 63A TPNMCB as outgoing of Breaking capacity 10kA & C characteristics as outgoing incl. 2 no. cable end box. (Make- Siemens (8GB31571RC)/ Legrand/ Schneider)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 6 way Enclosure, 63A FP isolator as incommer & 6-32A SPMCB -18nos as outgoing Make- Siemens(8GB32202RC06)/ Legrand/ Schneider)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way Enclosure, 63A FP isolator as incommer & 6-32A SPMCB -12nos as outgoing Make- Siemens(8GB32202RC04)/ Legrand/ Schneider)
Cutting Channel of size (31x31mm/40 mm x 40 mm/43x43mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge following, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire
b) 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supply & Fixing of following size PVC rigid conduit only 'FR' (Precision make) incl. necy. fittings as required
a) 20mm dia
b) 25mm dia
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes incl. S& F bakelite / perspex top cover by Brass screws, flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- Policab/ Havells/ KEI/ Currency) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
a) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC (from VTPNDB to 3ph AC machine)
b) 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC (from VTPNDB to 3ph AC machine)
c) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (from TPNDB TO SPNDB)
d) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC ( Power board/AC point)
e) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (15A power plug /computer board)
f) 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5sqmm
b) 4sqmm
c) 6sqmm
d) 10sqmm
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+12 way Enclosure, 63A DP MCB type isolator as incommer & 6-32A SPMCB - 12nos as outgoing. (Make- Siemens(8GB32102RC14)/ Legrand/ Schneider)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+8 way Enclosure, 63A DP MCB type isolator as incommer & 6-32A SPMCB - 8nos as outgoing. (Make- Siemens(8GB32102RC10)/ Legrand/ Schneider)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Policab/ Havells/ KEI/ Currency) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make- Legrand/ Goldmedel/ Crabtree) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
a) Average run 12 mtr
b) Average run 8 mtr
Do - do On board 5A plug
Supply & Fixing 240 V, 4 nos. 16 A, 5 pin Modular type plug socket with 4 nos. 16A Modular type switch (Make- Legrand/ Goldmedel/ Crabtree), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16A Modular type switch (Make- Legrand/ Goldmedel/ Crabtree), with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- Legrand/ Goldmedel/ Crabtree), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Make- Legrand/ Goldmedel/ Crabtree) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Legrand/ Goldmedel/ Crabtree) & necy. Connections.
Supplying and fixing 4 way MCB SS enclosure with IP-20/30 protection, powder coated with 40A, 415V FP MCB , concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make- legrand/ Schneider/ Siemens)
Supplying and fixing 2way MCB SS enclosure with IP-20/30 protection, powder coated provision for 40A DP MCB changeover (make Havells), concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (for UPS by pass)
Supplying and fixing 2way MCB SS enclosure with IP-20/30 protection, powder coated provision for 40A DPMCB (Make- legrand/ Schneider/ Siemens), concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (for UPS incomming)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make- Legrand/ Goldmedel/ Crabtree) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
S&F fixinging 19mm dia GI pipe for fan down rod (14 SWG) drill hole both sides for celing fan fixing & necy. PVC insulated wire and painting etc. as required by 2 x 22/0.3 (1.5 sqmm) stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC).
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S& Fixing 240V 50 Hz 56" sweep (1400 mm) ceiling fan complete with down rod,Canopy,fork etc. and Fixing the ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by3x1.5 sqmm single core stranded pvc insulated unsheathed copper wire. (Make- Orient- Summer breeze/ Crompton- High Speed)
S &f 250V follwing size heavy duty exhaust fan incl. making hole on wall/making steel frame to attach the fan &making good damages to smooth cement finishetc.as practicable as possible &providing necy length of insulated wire & necy. Connection.S & f of outside heavy duty louver/shutter. (Make: EPC)
a) 12" (300mm) dia
b) 9" (230mm) dia
S & F of 240 V 50 HZ 18" (450 mm) high flo oscillating type metal body Wall Bracket fan operated by pull cord switch with inbuilt regulator (Make -Orient, model- Tornado Wall-II/ Crompton)
Supply & Fixing 9W LED lamp on existing holder point. (Make- Philips/ bajaj/ Crompton)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
S & Fixing single/twin tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Make Havells cat no- STOUTPLUS1200BS40WLED840SPCWH / or equvalant philips/crompton
Make Havells cat no- STOUTPLUS600BS20WLED840SPCWH / or equvalant philips/crompton
Supply, Installation, Testing & commissioning of 1Ph/1Ph, IGBT based, DSP controlled, PWM technology double conversion true Online 6KVA UPS system having inbuilt Isolation Transformer at O/P with 12V SMF battery to provide 60Mints backup along with MS rack for battery & battery interconnecting cables. Battery VAH: 8064/ Sutable for cattering 60min. backup. Battery Make: Exide/Quanta Warenty: Not lessthen 3 years incl. Battery & UPS. Make : APC/ EMERSON/ POWERONE/ AVO
S & f sutable size GI net guard with key & locking arrangement for protect 3 nos 1 ph ups & battery set as per direction of EIC.
Construction of D G Set Foundation size by 16 (L) x 7 (W) x 3 (D) Ft (above GL) & 3 Ft (under GL) Ordinary cement concrete mix. 1 : 5 : 3 : with graded stone chips of 20 mm down pakur variety laying concrete base ( 1 : 3 : 6 ) using 40 mm down stone metal & single brick flat solling of picked jhama brick incl. at shuttering work by 25 mm to 30 mm thick wooden plank also , rein inforcement with 8 mm dia steel TMT bars atleast 181 KG total , this rate are incl. all materials , labour charges & carrying etc. (suitable for 125 KVA DG set)
Earthing By 50mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level
Earthing with 80 mm dia GI pipe (Class B Medium, ITC Make) 3.04 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mtr. (For morrum Soil) [Neutral Earthing 4nos, 4 nos for equipment body earthing] (for DG body & nutra earthing)
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts.below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter(inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for pipe electrode (for morrum soil)
Connecting the equipments to earth busbar including S & F copper strip of size 25 mm x 6 mm in UG trench with necy arrengement.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Extra for connecting the Earth busbar to earth electrode including S & F 19/10 Stranded GI (Hot Dip) wire on wall/floor with GI saddles & insulating the same by one layer of PVC tape over one layer of ampere tape (for DG Set)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) 4 SWG wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
ELCON ENGINEERS
ULTRA ELECTRICALS AND ELECTRONICS
KORUNAMOYEE ENTERPRISE
A.B. ENGINEERING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .