Loading…
Loading…
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
22 Dec 2025, 3:00 pmClosed
Sectional Signal Maintenance Contract (SSMC) for the sections of DSTE/FZR for one year.
433-Sig-T-57-25-26~NR
433-Sig-T-57-25-26
Open
Works - General
12 Months
Firozpur, Punjab
₹0
₹2.2 L
22 Dec 2025
29 Nov 2025
8 Dec 2025
1 Description:- Supply of Signal No. Plates as per Drg. No. RST -11393. Inspection: Consignee.
Description:- Supply of Insulation for 'L' type bracket for point fitting IRS type as per drg. No. SA-
drg. no. S-8804 Nylon Type-66 as per IRS-S-40/84 with latest amendment, Ferule - 02 Nos. conforming to drg. no. S-8813 as per spcn. no. IRS:S-40/84 material nylon type-66, washer - 04 Nos. conforming to RDSO drg. no. T-10371 ALT-2 IRS-40/84 nylon type-66. (Inspected by Consignee)
,T-10368/Alt. and to IRS S-23 and S-40. Inspection by Consignee.
RDSO Drg no. T-10367, T-10368, T-10384, IRS-23-88 with Amdt. 1 and S-40-84 with latest amendment. (Inspection: Consignee)
Description:- Supply of Insulation for 'P' bracket for point fitting IRS type complete consisting of Rail Joint splice Plate for 'P' bracket LH side - 01 No. as per RDSO Drg. no. S-3266 Nylon Type -66 as per
per RDSO Drg. no. S-3265 Nylon Type -66 as per IRS-S-40/84 with latest amendment, Bush for 'P' bracket -04 Nos. to Drg No. S-23199 as per spcn. IRS:s- 40/84 material Nylon Type, Insulating washer for insulated 'P' bracket -04 Nos. to RDSO Drg. no. S-8640 as per spcn. no. IRS-S-40/84 nylon type-66. (Inspection: Consignee)
Description:- Supply of Screw less mounted 2.5 sqmm. -4 wire front entry two input, two output disconnect cage clamp terminals block for test and measurement (wago or Phonix or Elmex) as per
RDSO approved sources. The color will be decided by Engineer in charge (Preferably in Blue, Red and Grey color in the ratio of 1:2:3) (Inspection : Consignee). FEROZPUR DIVISION-S AND T/NORTHERN RLY
Chrome Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection :Consignee.
RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection :Consignee
similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection :Consignee
:Fluke 17B+, DI-LOG 9206, or similar or better. (Inspection by Consignee)
(Inspection by Consignee)
addison or better. (Inspection: Consignee)
as per RDSO Spec. No. RDSO/SPN/177/2012 Ver.-3 or latest compatible for G.G.Tronics make HASSDAC. (Inspection by RDSO)
21/25) as per RDSO Spec. No. RDSO/SPN/177/2012 Ver.-3 or latest compatible for G.G.Tronics make HASSDAC. (Inspection by RDSO)
SSDAC/HASSDAC. (Inspection by RDSO)
16 Description:- Supply of Lead wool of Good Quality. (Inspection: Consignee)
insertion for 2 aspect Unit. Inspection by Consignee.
insertion for 3 aspect Unit. Inspection by Consignee.
insertion for 4 aspect Unit. Inspection by Consignee.
insertion for Route Arm. Inspection by Consignee.
FRP material conforming to RDSO/SPN/151/97 or latest with 450mm long and 25mm dia. pipe. (Inspection: Consignee)
Description:- Supply of CAT-6 (STP) cable as per RDSO specification RDSO/SPN/TC/65/2016 Rev. 3.0
be provided that the material has been manufactured as per RDSO specification attached. Make-D- Link/Amp/Systimax. Inspection by Consignee
No. GR/OFC-02/03 September 2003. (TEC Standard Number-TEC 85010-2003) (Inspection: Consignee)
RDSO/SPN/TC44/02 Ver.2.0 Amendment No.2 or latest. (Inspection by Consignee) FEROZPUR DIVISION-S AND T/NORTHERN RLY
IRS-S : 75/2006 (Rev.-2), SA 23748/ALT-4 or latest. Make NANDI or similar. (Inspection: Consignee)
signalling of RDSO Spec No. IRS S : 78/2006 (Rev. 2.0) or latest with 2 amp. fuse. (Inspection: RDSO)
signalling of RDSO Spec No. IRS S : 78/2006 (Rev. 2.0) or latest with 4 amp. fuse. (Inspection: RDSO)
signalling of RDSO Spec No. IRS S : 78/2006 (Rev. 2.0) or latest with 6 amp. fuse. Cylindrical Cap type. (Inspection: RDSO)
signalling of RDSO Spec No. IRS S : 78/2006 (Rev. 2.0) or latest with 16 amp. fuse. Cylindrical Cap type. (Inspection: RDSO)
requirement at site) conforming to IS 694/2010 or latest. (Inspection: Consignee subject to specification compliance from RDSO approved vendor)
sheathed for indoor railway signalling of size 16/0.20 mm as per RDSO Spcn. no. IRS : S 76-89 amdt. 3 or latest. (Inspection: RDSO) S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () C-Supply & Execution Item 3239287.30
NR/S&T/CON/1.1/97-A or latest as per instructions of the site Engineer. (Bricks Inspection: Consignee)
Description:- Boring & trenchless, cabling along with supply and insertion of Double walled corrugated HDPE duct as per RDSO spec. no. RDSO/SPN/SPN/204/2011 ver.1.1 and amendment 1 or
signaling/telecom/power cables under the track/road. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers with rubber O ring 2. Spacers 3. Tees 4. Bend 5. End cap etc. to be supplied along with the pipe. Work at site shall be inspected by Site engineer & DWC HDPE pipe and it's accessories to be inspected by RITES.
Description:- Supply, installation and fixing of 25mm dia. PVC conduit medium class pipe with all
conform to IS 9537 (Part 3) : 2021 or latest as per technical specification & instructions of Railway Engineer at Site. Inspection by Consignee.
Description:- Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc.
conforming to IS 6946: 1978 & IS:9537 Part-III 1987 (or latest version) size 25 mm dia. Inspection by consignee.
Description:- Casting, concreting, curing of foundations and erection of WARNING BOARDS
as per IRSEM or HQ policy has to be done by the contractor. Board should be provided on I -Shaped channel having minimum weight of 8.9 kg/meter and length 5000mm. Channel also to be supplied by the contractor. (Material inspection: Consignee
Description:- Supply and making of Thermo-shrinkable Derivation/Termination joint using jointing kit
TC 77-2012, Rev. 3, Amendment 1, 2 & 3 or latest if any. This shall be done as per instructions of site engineer at site. This included excavation of jointing pit and materials needed for making a joint. (Inspection: RDSO for supply portion).
FEROZPUR DIVISION-S AND T/NORTHERN RLY Description:- Supply and making of Thermo-shrinkable straight through joint using jointing kit
TC 77-2012, Rev. 3, Amendment 1, 2 & 3 or latest if any. This shall be done as per instructions of site engineer at site. This included excavation of jointing pit and materials needed for making a joint. (Inspection: RDSO for supply portion).
Description:- Supply of Provision of Emergency socket joints with 6 Quad cable and PIJF cable with
The include all material required for jointing including Thermo shrink jointing kit will be supplied by contractor except 2T VF Transformer (2T VF Transformer will be supplied by the Railway) as per IRS:TC-77/2010 (Rev-2) with amendments (Inspection by Consignee)
Description:- Supply and installation of Optical fiber cable joint enclosure as per
& Jointing materials as mentioned in the Specifications and splicing of Optical Fiber cables (24 fibers) and testing. This includes provision of prefabricated/ RCC Joint pit as per RDSO/TCDO/COP-21. (Inspection by Consignee).
Description:- Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. NR/S&T/CON/6.4/97 or latest. The soil treatment shall be done as per std. practice. The item includes provision of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to
racks, other equipments as per the instruction of Engineer at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete material such as earth electrode as per drg. No. NR/S&T/CON/6.3/97 or latest, cement, wiring material, soldering material be supplied by contractor. This also includes provision of earth connection from MEBB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, Data logger with power wire of size 16/25 sq. mm with thimble of suitable size at both ends. (Inspection by Consignee). S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () D-Execution Item 7696622.69
Description:- Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. NR/S&T/CON/1.1/97-A or latest so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr.
signalling and cable plan. It also includes clearance of routes of trees & bushes. Lesser depth due to site conditions shall be paid proportionately after obtaining prior approval from not below than JAG officer. (Inspection: Site Engineer)
Description:- Laying of signaling/telecom/power cables by unwinding cables from drums of different
route plan approved by the railways. Meggering of cable before and after its laying of all types of cables. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways. (Inspection: Site engineer)
Description:- Cleaning, scrapping, painting & lettering of all newly installed & existing gears such as signals, point equipment, track circuit equipment with TC No. on rail, app. cases, JB, TLJB, point
provision of IRSEM. All paints (ISI marked) with IS specification No. IS:15489:2004 or latest Asian /Burger/ Nerolac or similar reputed make. shall be approved by Railway Engr. and painting materials to be supplied by the contractor. (a) Medium Station (Upto 4 Lines) (Inspection: Site Engineer)
Description:- Cleaning, scrapping, painting & lettering of all newly installed & existing gears such as signals, point equipment, track circuit equipment with TC No. on rail, app. cases, JB, TLJB, point
provision of IRSEM. All paints (ISI marked) with IS specification No. IS:15489:2004 or latest Asian/Burger/ Nerolac or similar reputed make. shall be approved by Railway Engr. and painting materials to be supplied by the contractor. (a) Big stations (More than 4 Lines) (Inspection: Site Engineer)
FEROZPUR DIVISION-S AND T/NORTHERN RLY
aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement, sand ratio. It also includes excavation of earth as required at site and as per instruction of site engineer. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. cement, coarse sand and aggregate 25mm are to be supplied by the contractor. (Inspection: Site Engineer)
Description:- Earth work for excavation & refilling around location boxes and signals etc. where
location to the center of filling & lift from main ground level. The earth work should be well rammed including breaking of clods, levelling and dressing etc as per instructions of the site engineer.
(ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Site engineer)
Description:- Casting, concreting and curing of foundation and erection of App. Cases Large as per drg. No. NR/S&T/CON/2.7/97 or latest. All materials such as cement, sand, aggregate and anchor bolts
foundations if required during inserting the cable for termination. (All concrete work must be ratio of cement, coarse sand and aggregate 1:3:6 and outer surface should be plastered with 1:4 cement and sand).(Inspection: Site Engineer)
Description:- Preparation of App. Case Large involving wiring of relays. Work involves following: Preparation & fixing of Bakelite hylum sheet 910x800x6mm and teak wooden shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal, shelf type Q series relays and other type relays on square bars, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom.
each cable through the salwood plank & all cable entry points on location boxes, location huts, JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses, bases, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the railways. (Inspection: Site Engineer)
Description:- Casting, concreting and curing of foundation and erecting of Apparatus Cases medium
anchor bolts shall be supplied by the contractor. Contractor is required to execute all types of repairs works of foundations if required during insertion of cable for termination. All concrete work must be ratio of cement, coarse sand and aggregate 1:3:6. (Inspection: Site Engineer)
Description:- Preparation of Apparatus Case half not involving wiring of relays which includes following-(i)Preparation and fixing of Bakelite hylum sheet 450x800x6mm and teak wooden shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mm/25mm/3mm. Angle iron frame will be fixed in location box secured by nuts & bolts. (ii)Fixing of fuse ARA terminal, shelf type Q series relays and other type of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank provided at the
separately for each cable through the salwood plank and of cable entry points on location boxes, location nuts JB's relays room battery/room to be closed with suitable masonry work covered with sand & plastering. (iii)Wiring description for terminal, drawing of circuits inside app. Case. Painting from outside as well inside with RED oxide aluminum paint is covered separately. Size of lettering as per instructions of Engr. at site. (iv)All material including teak wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS spec. Non deteriorating type HRC fuses and bases nuts and bolts and other items shall be supply by the contractor. (Inspection: Site Engineer)
Description:- Casting, concreting and curing of foundation for main signal as per Drg. no.
contractor. All concrete work must be ratio of cement, coarse sand and aggregate 1:3:6.(Inspected by Site Engineer)
FEROZPUR DIVISION-S AND T/NORTHERN RLY Description:- Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an offset bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6 mm thick wherever required. This includes provision of wooden (sal) cross arm 1 M x 1M
hoods of CLS unit, terminating cables, wiring the CLS unit & foxing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian railways published by Govt. of India and approved drawings. All items for the above works except signal unit, LED signal, Signal post, base and ladder shall be supplied by the contractor including but not limited to the following: (i) "U" bolt for offset brackets. (ii) Wooden cross arm 1 mtr. x 1 mtr. (iii) MS angle and MS sheet for blanking of ladder. (iv) Wire mesh guard, lock for unit if required, nuts and bolts etc. for the following : (V) Supply and fixing of Signal Number Plate with complete fittings as per standard railway practice. Installation, erection, wiring of 3/4 aspect color light signal. (Inspected by Site Engineer)
Description:- Providing 1.8 mtr. high fencing with 2.4 mtr angle iron 50x50x6mm posts placed every
abrupt change of ground slope). Last but one end post and corner post shall be abutted on both sides
horizontal lines and two diagonals interwoven with horizontal GI barbed wires of barbed wire 9.38 kg per 100 meter(m) between the two posts fitted and fixed with GI stupless, turn buckles etc. complete (Cost of posts, struts and concrete to be paid separately as per site condition). (Inspection: Site Engineer)
Description:- Refilling of CO2 type fire extinguishers 4.5 kgs. capacity. The extinguishers shall be
date of refilling & due date of expiry shall also be written on the fire extinguisher. (Inspection: Consignee)
Description:- Fixing of Track lead junction box due to repositioning of old Track circuits as per NR drg. no. NR/S&T/CON/3.2/97 or latest. This also includes erection of track lead junction box and
aggregate and sand mixture of 1:3:6. This also includes excavation ramming, curing and plastering of foundation with cement sand mixture of 1:4 ratio. All the material like cement, sand, aggregate, angle iron, nuts and bolts etc. are to be supplied by the contractor. (Inspection: Site Engineer)
Description:- Maintenance of track mounted equipment like S&T fittings on turnouts including different activities during BCM/TTM/TTR works as follows:- Especially opening and refixing of DCTC jumpers/Axle counters transducers during different engg. works. Opening of DCTC jumpers/axle counters transducers digging work from rail to TLJB/TMU/0 bond/location is required to be done as
buried in proper depth. It includes drilling hole in rail as per site requirement. The team to be provided for this work should comprise of Wireman-1 No. and HelperS-3 Nos. also it include any work of EOLB or sliding boom and earthing arrangement of signalling gears or any other work as per instructions of Railway Engineer. All T&P & Jigs required to execute the work will be supplied by Contractor. (Inspection: Consignee)
Description:- Maintenance of Track Mounted Equipments like S&T fitting on turnouts including different activities during BCM/TTM/UNIMAT machine works as follows: Especially opening and re- fixing of DC Track circuit jumpers / Axle Counter transducers during different Engineering works. Opening of DC Track circuit /Axle Counter transducers digging work from rail to TLJB/TMU/Location is
transducers needs to be buried in proper depth. It includes drilling hole in rail as per site requirement. The team to be provided for this work should comprise of: Fitter-1 Nos. Blacksmith-1 Nos, Mason/Carpenter-1 Nos. and helpers-5 Nos. also it includes any work of Electrical operated lifting barriers (EOLB) or sliding boom and earthing arrangement of Signalling gears. Any other work as per instruction of Railway engineer. All T&P & jigs required to execute the work will be supplied by the contractor. Inspection: Consignee. (NOTE: The unit for this item may be read as "per day per team")
Description:- Supply of Highlighter grade retro reflective tape made up of non metalised polycarbonate micro prismatic, visible from 1000 meters, highly durable ASI 90 specified, reflection
are to conform compliance to ASI 90. Size per four feet width in roll. Make 3M, AVERY or better. (Inspection by Consignee). FEROZPUR DIVISION-S AND T/NORTHERN RLY
Description:- Composing, Printing & Binding of different types of registers and history cards which consist of 1. Point Crossing joint inspection register consisting of at least 140 pages.- 1 nos. 2. Battery Maintenance Register consisting of at least 100 pages-1 nos. 3. Axle Counter Register consisting of at least 100 pages- 1 nos. 4. Block Instrument Register consisting of at least 100 pages- 1 nos. 5. Lifting
pages- 1 nos. 7. Cable Testing Register (SPIRAL) consisting of at least 100 pages- 1nos. 8. Track Circuit Register consisting of at least 100 pages- 01 nos. 9. Earth Testing Register consisting of at least 100 pages.- 1 nos. 10. Signal history Card (size A4)-10 nos. , 11. Printing of Motor Point history Card (size A4) - 12 nos. 12 Track Circuit history Card (FEED END) (size A4)- 30nos. 13.Printing of Track Circuit history Card (Relay END) (size A4).- 30 nos. 14. SSDAC Track History Card (size A4)- 04 nos. (Inspection: Consignee)
Description:- Repairing of electrical lifting barrier Boom pieces as per instruction of Railway
transportation of material will be done by the contractor with his own arrangements. (Inspection By Consignee)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .