| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹23.8 CrAccepted-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹23.8 Cr | 1st | Accepted-AOC 1st |
| 2 | 2nd₹23.9 CrRejected-AOC 52 SHANTI NAGAR MODEL TOWN PANIPAT OPPOSITE AMAR STEEL SHUTTERING WORKS | PANIPAT | HARYANA | 132103 | ₹23.9 Cr | 2nd | Rejected-AOC 2nd |
| Sl No | Description | Qty | Unit | Jai Shree Balaji Constn Co. L2 | ROHTASH KUMAR CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.10 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd
10 mm2 3core | 120 | Per Meter | 490 ₹58,800 | 540 ₹64,800 |
| 1.20 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Panel Board for motors having capacity of 5 BHP | 2 | Each | 85,000 ₹1.7 L | 15,000 ₹30,000 |
| 1.30 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each).
Panel Board for motors having capacity of 7.50 BHP | 2 | Each | 85,000 ₹1.7 L | 20,000 ₹40,000 |
| 1.40 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Panel Board for motors having capacity of 20 BHP | 1 | Each | 1,35,000 ₹1.4 L | 30,000 ₹30,000 |
| 1.50 | Provision for lowering the water table up to 7.00 m average depth for laying the sewerage network complete in all respect. | 25,285 | Per Meter | 250 ₹63.2 L | 300 ₹75.9 L |
| 1.60 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd
16 mm2 3core | 30 | Per Meter | 690 ₹20,700 | 760 ₹22,800 |
| 1.70 | Operation and Maintenance for complete scope of work covered under this contract as per OandM schedule for a period of 5 year after successful completion of 12 month`s defect liability period and 3 Months trial run complete in all respect as per approved NIT. The amount will be charged to the A/Mtc. Estimate 1)Operation and maintenance during defect liability period (operation only) | 1 | Job | 8,35,000 ₹8.3 L | 15,00,000 ₹15 L |
| 1.80 | 1st year Operation and maintenance | 1 | Job | 9,45,000 ₹9.4 L | 15,00,000 ₹15 L |
| 1.90 | 2nd year Operation and maintenance | 1 | Job | 10,40,000 ₹10.4 L | 15,00,000 ₹15 L |
| 2.00 | 3rd year Operation and maintenance | 1 | Job | 11,30,000 ₹11.3 L | 16,00,000 ₹16 L |
Tender Value
₹22.0 Cr
EMD Value
₹44.1 L
Closing Date
14 Sept 2023, 3:00 pmClosed
SANJEEV KUMAR TYAGI
EE PHE Division No. 1 Hisar
FOR PROVIDING SEWERAGE SYSTEM Construction of IPS and Manholes at village Gangwa District Hisar comprising wet well sump , pump chamber, HDPE rising main line Pumping machinery HT metering panel room DG set electric transformers panel boards and Layi
2023_HRY_305487_1
2023A47DEF85 E266 4747 A841 0466C37BD051564PUH
Open Tender
Civil Works
360 days
Gangwa
Construction of IPS and Manholes at village Gangwa District Hisar comprising wet well sump , pump chamber, HDPE rising main line Pumping machinery HT metering panel room DG set electric transformers panel boards and Laying the sewer line etc
3 documents required · 3 mandatory
₹20,000
₹44.1 L
Yes
19 Aug 2025
25 Aug 2023
14 Sept 2023
25 Aug 2023
14 Sept 2023
25 Aug 2023
25 Aug 2023 - 14 Sept 2023
Amount
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 10 mm2 3core
PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Panel Board for motors having capacity of 5 BHP
PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each). Panel Board for motors having capacity of 7.50 BHP
PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Panel Board for motors having capacity of 20 BHP
Provision for lowering the water table up to 7.00 m average depth for laying the sewerage network complete in all respect.
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 16 mm2 3core
Operation and Maintenance for complete scope of work covered under this contract as per OandM schedule for a period of 5 year after successful completion of 12 month`s defect liability period and 3 Months trial run complete in all respect as per approved NIT. The amount will be charged to the A/Mtc. Estimate 1)Operation and maintenance during defect liability period (operation only)
1st year Operation and maintenance
2nd year Operation and maintenance
3rd year Operation and maintenance
4th year Operation and maintenance
5th year Operation and maintenance
Bidder Name
Amount
Jai Shree Balaji Constn Co.(GSTN-06AKLPK7500N1ZV)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
ROHTASH KUMAR CONTRACTOR
Jai Shree Balaji Constn Co.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid