| 1 | L1₹39.1 LAccepted-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹42.4 L+₹2.5 L (6.23%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L2 | Rejected-AOC BEING NO L1 |
Tender Value
₹48.7 L
EMD Value
₹97,400
Closing Date
23 Feb 2023, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS/REPLACEMENT OF UNSERVICEABLE SPARES OF AC PLANT AND REPAIRS TO RO PLANT, OFI, MECHANICAL LAUNDRY AND ALLIED WORKS UNDER AGE E/M NO-II OF GE (U) SECUNDERABAD
2023_MES_576721_1
GE (U)/SEC/TOKEN/66 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹97,400
Yes
11 Aug 2023
23 Jan 2023
2 Mar 2023
23 Jan 2023
23 Feb 2023
6 Feb 2023
Amount
M&L for Blue star 2x40TR +1x40TR Scroll compressor chiller type air cooled AC Plant inspection and fault rectification carried out by Manufacturer Engineer for releasing out locking setting the programming for proper functioning of AC plant and to rectify other minor/major problems, including Re-programming & rectify faults occured as and when, with all necessary tools and machines and other major problem & faults (faults either software problem or hard ware) including providing new software if software not working properly with all necessary tools and machines.
All as per Item No.1 here in before but for Hitachi 4 x 8.5 TR + 2 x 8.5TR ductable type air cooled packaged AC Plant Note for Item No. 1 and 2 :- (i)Transportation & loading charge with hiring of machines and equipments are deemed to be included in quoted rates (ii) The requisite material shall be mesured & piad separately under relavent items iii).The service Engineer shall be from OEM only.
Evacuation of gas from each Chiller Unit of 8.5 TR package type System/central type AC plant and leak testing the system by giving the dry nitrogen by separating the low side /high side of the system and arresting the leaks including replacement of Teflon seating of the all refrigerant line, suction/discharge valves of compressor, gland package of all angle valves flaring off and charging complete all as directed by Engineer-in-charge. Note :- Quoted rate is deemed to be inclusive of cost of nitrogen gas
All as per Item No. 3 here in before but for 40 TR(each chiller unit) of AC Plant Chilled system.E16
S&F of 'V' Belts ISI marked suitable for existing one of the following size A-32 to 34.
All as per Item No. 5 here in before but for size B-84
Supply and charging the Refrigerant Gas R- 410A complete all as directed by Engineer-in-charge.
Supply and charging the Refrigerant Gas R- 407C complete all as directed by Engineer-in-charge.
Draining out the old compressor oil from various compressors and supplying, filling/ top up of compressor oil of Freezol-68/ freezol F-57 complete all as directed by Engineer-in-charge.
Servicing and cleaning of Double skin AHU(including blower & existing heat bank strip) unit of capacity 4000CFM including Cleaning of the evaporating coil (AHU coil) with cleaning Acid forced feed method to remove the unwanted dust particles formed on the coil and in AHU unit, cleaning of the filter, greasing to the AHU unit bearing of the structure, expansion valve etc and testing complete all as directed by Engineer-in-charge.
All as per Item No. 10 here in before but for AHU Capacity 12800CFM.
All as per Item No. 10 here in before but for AHU Capacity 6000CFM.
Renewal of unserviceable condenser safety valve 15mm to 20mm, withstand pressure 300-800 PSI complete all as directed by Engineer-in-charge
S&F in Liquid line Filter Dryer suitable for 8.5 TR capacity Compressor unit complete all as directed by Engineer- in -Charge.
All as per Item No. 14 here in before but for 40 TR capacity Compressor unit complete all as directed by Engineer- in -Charge. Make for item Nos 14 & 15 : Emerson/Jhonson/Honewell
Disconnecting the Motor of condenser / Blower/ Chiller/ AHU units from installed position, disconnecting the pump and rewinding the same with super enamelled copper wire of same gauge and turns as per existing, replacement of wornout Bearings fixing back on its original exisiting position, testing and commissioning complete for the following capacities :- Note : Transportation charges is deemed to be included in quoted rate (i) up to 7.5 hp capacity
All as per Item No. 16 here in before but above 7.5hp to 15hp
Renwal/Replacement of electronic star delta timer along with LED incations,including talking down old one complete all as directed by Engineer-in-Charge. Make:GIC/SEIMENS/Minilec
Renwal/Replacement of single phase preventor with following LED indications 3- phase healthy -ON, phase -loss -OFF including talking down old one complete all as directed by Engineer-in-Charge. Make:GIC/SEIMENS/Minilec
Taking out unserviceable MS pipe and Supply, erection, testing & commissioning of New 125mm(5") dia bore, mild steel chilled water piping of class'C",cut to required lenth and installed with welded joints,inclduing all necessary fittings such eblows,tees,bends,reducers,flanges and necessary civil/MS supports,pressure testing etc complete.chilled water pipe insulation shall be with 32mm thich nitrile rubber covered with vapour barrier and finished with 26G alumiunium clading complete all as directed by Engineer-in-Charge.
All as per Item No. 20 here in before but for size 75mm(3") dia bore complete all as directed by Engineer-in-Charge.
All as per Item No. 20 here in before but for size 40mm(1.25") dia bore complete all as directed by Engineer-in-Charge.
Taking out unserviceable butterfly vlave and Supply,erection,testing &commissioning of New 75mm(3") dia bore, butter fly valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engineer-in-Charge. Make: Advance/Castle or equivalent as approved by GE.
Taking out unserviceable Globe valve and Supply,erection,testing &commissioning of New 75mm(3") dia bore, globe valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engineer-in-Charge. Make: Advance/Castle or equivalent as approved by GE.
Taking out unserviceable NRV and Supply,erection,testing &commissioning of New 75 mm(3") dia bore ,Non -return valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engineer-in-Charge. Make: Advance/Audco/Inter valves/Sant
Taking out unserviceable Y-strainer and Supply,erection,testing &commissioning of New 75 mm(3") dia bore, Y-strainer PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed including taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:Sant/Advance/Emerald
Suuply, test, install & commissioning of the pressure guage suiatble for existing one as per latest engineering standards and spcifications,fixed with necessary insulations(matching to existing) as required including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. Make: H Gurunserviceableant/Waree
Suuply, test, install & commissioning of the Thermo meter suitable for exisitng one as per latest engineering standards and spcifications,fixed with necessary insulations(matching to existing) as required including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. Make:H Grunserviceableant/Ware.
Supply, install, test & commissioning of the water flow swtich suitable for existing one as per latest enginnering stanards and specifications ,fixied with necessary insualtion(matching to existing) as required including taking down old unserviceable one complete all as directed by Engineer-In-Chrarge. Make: Honey well/Johnsons/Siemens
Supply, test, install & commissioning of the Auto air vent of suitable size 15mm dia to 20mm dia as per latest engineering standards and specifications,fixed with necessary insulation(matching to exisitng) as required inclduing taking down old unserviceable one comeplete all as directed by Engineer-In-Charge. Make:Amtrol/Anergy/flammcotraders
Supply, test, install & commissioning of the rubber bellow connections for pumps as per latest engineering standards and specifications,fixed with necessary insulation(matching to exisitng) as required inclduing taking down old unserviceable one comeplete all as directed by Engineer-In-Charge. Make: Cori/Easyflex
Supply, install, test & commissioning of Micro bubbler Air & Dirt separators,with matching flanges bolts,Nuts,gaskets,insulation,vlaves and airvent for the size of 150mm dia PN 1.0 including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. Make: Amtrol/Anergy/flammcotraders
Supply, install, testing and commissioning Suction line with fittings of hard copper piping for condensor units with isulation of 6mm thick nitrile rubber pre formed sections includingsupporting fixtures and accessories etc suitable for Hitache 8.5TR packaged type unit complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commissioning liquid line with fittings of hard copper piping for condensor units with isulation of 6mm thick nitrile rubber pre formed sections includingsupporting fixtures and accessories etc suitable for Hitache 8.5TR packaged type unit complete all as specified and directed by Engineer-in-Charge.
Supply, insulation, test and commissioning of under deck insulation for exposed roof of 23mm thickness Class 'O' grade XLPE material all as specified and as directed by Engineer-In-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of OT unit, MH complete all as directed by Engineer--in-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of ICU unit ,MH complete all as directed by Engineer--in-Charge
M&L for cleaning of existing duct unit along with volume control dampers,fire dampers,collar dampers,intake louvers,bird screen,inscet screen,grills & diffusers and removing dust particles with suitable liquid of Air cooled plant, MCEME auditorium complete all as directed by Engineer--in-Charge
S&F of 3 pole power contactor MNX-12,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge.
S&F of 3 pole power contactor MNX-18,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge.
S&F of 3 pole power contactor MNX-25,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge.
S&F of Add on block MNX-A1 for 3 pole power contactor suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge.
S&F of Add on block MNX-A2 for 3 pole power contactor suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge.
S&F of DOL MN2 -Thermal overload relay suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge.
S&F of analog timer suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge. Make: L&T/GIC/Schnieder/Siemens
S&F Refrigerent gas R - 22 for AC Plant complete all as specified and directed.
S&F of 3 pole MCB,40-63amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge.
S&F of 3 pole MCB,6-32 amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge.
S&F of 3 pole power contactor CHINT NC1-4011,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge. Make:CHINT NC1-4011 or its equivalent in L&T/Siemens/Schneider as approved by GE.
Supply & fixing of 3 pole Air break (power) contactor suitable 10-0A,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge. Make:Seimens -3TS30 10E or its equivalent in L&T/Schneider as approved by GE.
Taking out unserviceable chilled water inlet sensor & supply and fixing of new chilled water sensor complete all as directed by Engineer-in-Charge.
Taking out unserviceable chilled water outlet sensor & supply and fixing of new chilled water sensor complete all as directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable oil tight limit swtich and S& new Oil tight limit switch complete all as directed by Engineer-in-Charge. Make:TEKMEC/Honeywell
S&F main switch with HRC fuses of 3 pole with neutral 160A capacity,50Hz,3-Ph, front handle operated including necessary cable connections, nuts bolts complete all as directed by Engineer-in-charge.
Renwal/Replacement to existing unserviceable PCB board(mother board) suitable for exisitng Blue star scroll compressor(compatiable for 4 -compressors air cooled DLT type) chiller plant of capacity 40 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engineer-in-charge. Note:Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Renwal/Replacement to existing unserviceable Display PCB board suitable for existing Blue star scroll compressor(compatiable for 4 -compressors air cooled DLT type) chiller plant of capacity 40 TR including installation of suitable software with including talking down old unserviceable one complete all as directed by Engineer-in-charge. Note:Installation and commissioning shall be done by OEM only. Make:Suitable for OEM recommended.
Taking out unserviceable balancing vlave and Supply, erection, testing & commissioning of New 75mm(3") dia bore, balancing valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engineer-in-Charge. Make: Advance/Castle or equivalent as approved by GE.
Taking out unserviceable 3-way mixing valve and Supply, erection, testing & commissioning of New 62.5 mm(2.5") dia bore, 3-way mixing valves PN 1.0 rating as per latest engineering standards and specifications,fixed with necessary insulation(matching to existing) as required all as specififed and as directed complete all as directed by Engineer-in-Charge. Make: Honeywell/Jhonsons/Siemens/rapid control
Disconnecting & Taking out un servicebale MCCB and S&F of new MCCB 400 Amps, 36 KA, 4 pole, 415 volts, 50 HZ adjustable settings,thermal,magnetic release type suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old unserviceable one complete all as directed by Engineer-in-Charge.
Disconnecting &Taking out old unserviceable MCCB and supply & fixing of new MCCB 100 Amps, 25 KA, 3pole, 415 volts, 50 HZ , suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old unserviceable one complete all as directed by Engineer-in-Charge.
Disconnecting &Taking out old unserviceable MCCB and supply & fixing of new MCCB 100 Amps, 25 KA, 4pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old unserviceable one complete all as directed by Engineer-in-Charge.
Disconnecting &Taking out old unserviceable MCCB and supply & fixing of new S&F MCCB 160 Amps, 36 KA, 3 pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old unserviceable one complete all as directed by Engineer-in-Charge.
Disconnecting &Taking out old unserviceable MCCB and supply & fixing of new S&F MCCB 200 Amps, 25 KA, 4 pole, 415 volts, 50 HZ adjustable settings, suitable fixing for exsting panel and including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections and taking out old unserviceable one complete all as directed by Engineer-in-Charge.
Taking out old unserviceable rotary handle and supply & fixing of new S&F of Exended ROM(Rotary handle) kit suitable for existing one inclding neccesary connections and taking out old unserviceable one complete all as directed by Engineer-in-Charge Make :L&T/Siemens/Schnieder/ABB/Legrand or equivalent as approved by GE.
Supply & fixing of 3 pole power contactor MnX-12,50Hz suitable for existing one and including taking down old unserviceable one complete all as direrected by Engineer-in-Charge. Make: L&T/Schnieder/Siemens
Taking out unserviceable VFD drive from its existing position and Supply,test, install & commissioning of VFD drive of capacity 11kW/15Hp,415volts,3-Ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engineer-in-Charge. Make: Danfoss VLT micro drive- 132F0058 or its techno commerical equivalent in L&T/Yaskawa/Fuzi as approved by GE.
Taking out unserviceable VFD drive from its existing position and Supply,test, install & commissioning of VFD drive of capacity 3.7kW/5Hp,415volts,3-Ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engineer-in-Charge. Make: Danfoss VLT micro drive- 132F0026 or its techno commerical equivalent in L&T/Schnieder/Yaskawa/Fuzi as approved by GE.
Taking out unserviceable VVVF drive from its existing position and Supply,test, install & commissioning of VVVF drive of capacity 3.7kW/5Hp,415volts,3-ph,50Hz including necessary progamming and software & necessary connections suitable for existing one complete all as directed by Engineer-in-Charge. Make: L&T Cx 2000-LTVF-C40010BAA or its techno commerical equivalent in L&T/Yaskawa/Fuzi as approved by GE. Note for item No 66 to 68 : Installation & commissioning shall be done by OEM only.
DGQA 12.50 TR AC Plant SM No 198186
S&F Thermostatic Switch operated on 230 Volts AC Supply suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F Coil for loading and un-loading solinoid valve suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F Main bearing non end driving for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Main bearing driving end for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Connecting rods for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Discharge reed with springs (set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Suction reed with springs (Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Piston ring( Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Cylinder liner ( Set of 4) for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Piston for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Gasket set for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No 198186
S&F Gudgeon pin with bush for the Compressor Model SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F shaft seal assembly including carbon ring suitable for make ACCEL, Compressor of capacity SMC 4-65 complete all as specified and directed. Make 'ACCEL' DGQA AC Plant SM No. 198186
S&F Thermostatic Expansion Valve suitable for12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F Solinoid valve of existing size and model suitable for 12.50 TR AC Plant complete all as specified and directed. DGQA AC Plant SM No. 198186
S&F in replacement of crank shaft assembly suitable for 12.5 Ton AC Plant
S&F spare parts suitable to RO Plants of capacity 500 LPH-02 Nos including taking down old unserviceable spare parts complete all as specified and directed
Filter for RO Plant 500 LPH
Carbon Sand
40x40 Membrane
Flow meter
Pressure guage
PTMT Ball Valve
Pump NRV of suitable size
UV System
PVC Pipe
Disconnection RAW water feed pump 0.5HP and re-winding,including replacement of unserviceable bearings of suitable size and re-assembling the motor including installation complete all as specified and directed.
Disconnecting High pressure pump 500 LPH and re-winding, including replacement of unserviceable bearings of suitable size and re-assmbling the motor including instalation complete all as specified and directed.
Mebrane housing for 40x40 RO membranes.
Taking out old blocked GI tubing with all accessories such as Bend, Elbow, Tees, Nipples, sockets, unions, reducers from any position (in trenches/ floors/ walls) and cleaning of the same and refixing in original position with necessry new GI fittings (ISI Marked)(if required) heavy grade and making good with existing surface including if necessary civil works like Brick, cement work etc., for the following dia of pipes complete all as directed by Engineer-in-charge :-
15 mm dia
20 mm dia
50 mm dia
Taking out old unserviceable GI pipe line and supply and fixing/ laying GI tubing medium grade laid in trenches/ floors or fixed to walls including necessary GI fittings such as bends, elbows, nipple, sockets, unions, reducers, tees etc and making good with existing surface following dia of pipes complete all as directed by Engineer-in-Charge :- Note:(i) The rates deemed to be inclusive of GI fittings & fixing/laying of pipe. (ii) Earth work shall be measured & paid separately under relevant items.
15 mm dia
20 mm dia
25mm dia
50 mm dia
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed by Engineer-in-Charge.
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed by Engineer-in-Charge
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed by Engineer-in-Charge.
S&F GI stop valves 20mm dia,cast copper alloy,screwed down,high pressure,with cruth or butterfly handle,screwed both ends including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. Make:Zoloto/Hindware/Zenith
S&F GI stop valves 15mm dia,cast copper alloy,screwed down,high pressure,with cruth or butterfly handle,screwed both ends including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. Make:Zoloto/Hindware/Zenith
Taking out water sample in clean container and getting the same tested from the “Department of Water and Waste Water Examiner, Institute of Preventive Medicine, Narayanaguda, Hyderabad” or “Any Govt Lab” for chemical tests complete all as directed by Engineer-in-Charge.
Taking out water sample in clean sterilised container and getting the same tested from the “Department of Water and Waste Water Examiner, Institute of Preventive Medicine, Narayanaguda, Hyderabad” or “Any Govt Lab” for bacterioligical tests complete all as directed by Engineer-in-Charge Note for item No 78 & 79 :- Sample water shall be taken from various places of MH and adjoing area under AGE EM-II(U) complete all as directed by Engineer-in-Charge .
S&F in replacement of following spare parts suitable to Oil fired incinerator capacity 60 Kg/ Hrs automatic waste feeding system fuel tank including taking down old unserviceable spare parts complete as under :-
M&L for Diesel Mono block fully automatic burners of Cat part No LO -20 including necessary spare ie, Sequence control, Ignition coil, transformer including necessary accessories. Make : Alfa Therm or its techno commercial equivalent make approve by GE.
M&L descaling of Primary Chamber 800 Degree Centigrade + 50 Degree Centigrade by Hydro chloric acid 33% concentration till the scaling is removed and cleaning of the chamber with fresh water.
M&L descaling of Secondary Chamber 1050 Degree Centigrade + 50 Degree Centigrade by Hydro chloric acid 33% concentration till the scaling is removed and cleaning of the chamber with fresh water.
M&L descaling of Secondary Chamber- static solid hearth mild cleaning by new technology method of the chamber with fresh water.
Repair & Replacement and servicing of automatic through hydraulic Ram pusher, hydraulic power pack.
Dismantling/Removing of oil fired incinerator Ventury Scribbing System ID Fan winding from motor, re-winding and Re-assembling the original position
Dismantling/Removing of FD Fan of Oil fired incinerator winding from motor, re-winding and Re-assembling the original position
M&L labour for cleaning of Air cooled AC plant of capacity 40 to 50TR Exahust Fans along with copper/tinted copper/Aluminum fins/coils along with suitable liquid chemical and water till desired effectiveness of cooling is achieved for satisfactory completion of job including all misc materials complete all as directed by Engineer-in-Charge,
Supply, test, install & commissioning of 6'x8' laminar flow terminal filter units for OT being made of CRCA/Pre insulated panel material suitable for fixing HEPA filters including HEPA filter,perforated stain less steel sheet in the bottom suitable provision for OT light to be supported being part of the module including taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Laminar flow/Sagarair, Make of HEPA: AAF/Fudenburg/Camfil
M&L labour for servicing of 15 KVA UPS by Visual inspection of the battery set and UPS system, connected mains cables, battery cables, distribution boards and the external maintenance bypass switch, Battery terminal connections will be inspected and tightened and re-torqued, alarm and system logs are downloaded and inspected to see how the UPS has performed, Internal components are inspected for age, wear and tear and cleanliness, consumable items like fans and AC and DC capacitors are inspected and replaced according to their replacement programs, checks are made for corrosion in extreme environments that can see dust build up or chemical or salt erosion, Thermal checks may be made using thermal imaging cameras which are used to find hot-spots in the UPS, batteries, cabling, distribution and LV switchgear connected to the UPS system, electrical measurements are taken from the front panel LCD to identify input and output performance per phase complete all as directed by Engineer-In-Charge.
All as per Item No. 83 here in before but for 80KVA UPS complete all as directed by Engineer-in-Charge.
Supply and drawn sub main wiring with four runs of 4 Sq mm single core PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through and including non metalic PVC rigid conduit accessories surface type on walls, floors etc including two runs of 4.0 Sqmm PVC insulated copper conductor for earth continuity wire all as specified. Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only.
All as per Item No. 85 here in before but for sub main wiring with four runs of 6 Sq mm and two runs of 4.0 Sqmm single core copper conductor for earth continuity all as specified. Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only
All as per Item No. 85 here in before but for sub main wiring with four runs of 10 Sq mm and two runs of 4.0 Sqmm single core copper conductor for earth continuity all as specified. Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia (THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification. GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC 1:2:4, B1 cover of 300 x 300 mm complete all as specified and directed.
M&L for painting of chiller units of OT including basement, suporting channels etc., with suitable colour coding by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of chiller units of ICU including basement, suporting channels etc., with suitable colour coding by using synthetic enamelled paint first grade after scrapping /cleaning
M&L for painting of Squirrel cage induction motors upto 10 HP capacity including basement, suporting channels, connecting pipe lines etc., with suitable colour coding by using synthetic enamelled paint first grade after scrapping /cleaning
supply of rubber mat ISI marked of size 1m X 2m X 20mm
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with necessary frame removable prepared by MS corss arm of required shape and size specified by Engineer - In- Charge.
Supply and replace contactor MNX 32 3 pole 32 Amps coil operating voltage 415 V 50 Hz complete all as specified and directed.
S & F of wall mounted digital temperature cum %RH controller (Digital Thermo Hygrometer) complete with large LCD, English display having operating voltage 24±10% V AC, 50 Hz frequency, ≤ 8 VA power consumption, 0.5 ºC temperature display resolution, 0.1% relative humidity display resolution, IP20 protection, etc. including battery and control wiring in PVC conduit from return air duct to AC Plant Room complete as specified and directed by engineer-in-charge. Make: Honeywell, HTC/Thermo-electric or equivalent as approved by GE.
M & L for low smoke zero helogen (LS0H) fire survival control cable of size 2 core, 2.5 mm² (for instrumentation)with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero helogen (LS0H) compound, single layr of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete all as specified and directed by engineer-in-charge. Make: Havells, Polycab, Finolex, RR Kabel
M&L for Servicing of 5 Nos RO plant including thorough checking and diagnosing any fault of filters, membrane, water storage tank, motors, pumps , connecting pipes and other parts and also replacement of pressure switches for automatic operation complete all as specified and directed by Engineer-in-Charge
Supply & Fix in replacement RO plant controller including testing of capacity 500 LPH complete all as specified and directed by Engineer-in-Charge Make : MIMIC Ro control panel / Astero 11 / APDP RO control panel
M&L for spray painting of 100kg capacity Washing machines at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint by scrapping with scrapping material shall confirm to IS 2032 including marking of SM/MES Number for each washing machine with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engineer-in-Charge.
All as per item No.99 here in before but for 50kg washing machines
M&L for spray painting of drying tubler at laundry plant MH (incluing inner and outer surface areas,motors and econimizer also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint by scrapping with scrapping material shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engineer-in-Charge.
M&L for spray painting of Steam Boilers and chimney at laundry plant MH (incluing inner and outer surface areas,motors,disel tank and econimizer also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engineer-in-Charge.
M&L for spray painting of 50kg capacity hydro extractors at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engineer-in-Charge.
All as per item no.103 but for 25kg Hydro extractor
M&L for spray painting of calander machine at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engineer-in-Charge.
M&L for spray painting of Air compressor unit at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engineer-in-Charge.
M&L for painting of MS/GI pipe line of different sizes by applying two coat of synthetic enameled black colour paint after removing all dust & rust and paint shall confirm to IS 2032 shall be directed by Engineer-in-Charge.
Supply & Fixing following spare parts suitable to Drying Tumbler of capacity 50Kg including taking down old unserviceable spare parts complete all as specified and directed. Make of dry tumbler: Supershine
Digital Tempreature meter
Timer
Auxillary contacts
Contactor relay M L 1, 3 phase 415 volts
Contactor relay M L 2, 3 phase 415 volts
Auxilary relay
Revenger (Reverse Forward)
Main Motor -V-belt
Motor bearings
Blower bearings
Reduction gear bearings
Main bearing
Solenoid valve
Push button
Steam strap 15mm
Door Locks
Door Beading
Exhaust Fan/Blower
1/2" Steam Valve
3/4" Steam Valve
Reduction gear V-belt
Brake actuator
Supply & Fixing following spare parts suitable to Hydro Extractor of capacity 25Kg including taking down old unserviceable spare parts complete all as specified and directed. Make of Hydro extractor :Supershine
Contactor M L 1, 3 phase, 415 volts
Timer relay
Transformer
Timer
Buffer
Limit switch
Main motor bearings
Push button
Motor to body springs
Rubber bush for Hydro Extractor
Hydro Extractor motor bearings
Bridge rectifier
Diode
Body Spring support Bolts
Supply & Fixing following spares suitable to Washing machine 50Kg, including taking down old unserviceable spare parts complete all as specified and directed. Make of wahing machine: Supershine
Digital Tempreature meter
Timer
Contactor relay M L 1, 3 phase, 415 volts
Contactor relay M L 2, 3 phase, 415 volts
Relay M L 1, 3 phase, 415 volts
Relay M L 2, 3 phase, 415 volts
Revenger (Reverse Forward)
Water Level Indicator
Steam solenoid Valve
Drain valve actuator
Main motor V-belt
Aux Motor V-belt
Washing Machine main bearing
Reduction gear bearing
Water inlet solenoid valve suitable for 50 kg washing machine
Water outlet solenoid valve suitable for 50 kg washing machine
Gland rope
Main motor bearings
Aux Motor bearings
Toggle swtich
Supply & Fixing following spare parts suitable to Boiler of capacity 600Kg/Hr including taking down old unserviceable spare parts complete all as specified and directed. Make of boiler: Thermax
Gland Washer (HTN-8)
Valve seat Assembly
Metalic Hose 3/8" x 40"
Oil Seal (HTN-5)
Oil Seal (HCA-7)
Ball Bearings (HCA-5)
Pressure Switch PVF 1.0
Pressure Switch PVF 16
Metallic Hose 1" x 1.2m
Limit Switch
Photocell 8205
Sequence controller MA 810
Solinoid Coil
Electrode Assembly
Electrode Cap
High Tension Wire
Packing Hylam
Packing Asbestos
Gland Nut (HTN-6)
Oil Level Indicator
Sight glass 50mm
Ignition Transformer 14.5 KV
Temperature Controller 0-400V
RTD Assembly 2.5 mtrs
Safety valve 25mm
Plug & Socket
Hooter 4" Dia
Lip Seal
Spider for love joy couple
Burner rod Without nozzle
Fuel Pump
Diffuser Plate 132mm dia
Nozzle 6.5 GPH, 45 Degree
Disel line Y strainer 25mm dia
Disel line globe Valve 25mm dia
Steam line Y strainer 25mm Dia
Steam line Globe valve 25mm Dia
Steam line Y strainer 40mm Dia
Supply & Fixing following spares suitable to Washing machine 100Kg including taking down old unserviceable spare parts complete all as specified and directed. Make of washing machines: Supershine & Megha laundry
Digital tempreature meter
Timer
Contactors ML 1, 3 Phase, 415 Volts
Contactors ML 2, 3 Phase, 415 Volts
Contactor relay M L 1, 3 phase, 415 volts
Revenger (Reverse Forward)
Water Level Indicator
Steam solenoid valve
Drain valve actuator
Main motor V-belt
Aux motor V-belt
Washing Machine main bearing
Reduction gear bearing
Indicator
Water inlet solenoid valve suitable for 100 kg washing machine
Water outlet solenoid valve suitable for 100 kg washing machine
Gland rope
Door Lock Knobs
Steam Valve (Globe)
Main motor bearings
Aux motor bearings
Toggle swtich
Supply & Fixing following spare parts suitable to Air Compressor of capacity 5HP including taking down old unserviceable spare parts complete all as specified and directed.
Limit switch
Motor bearings
Compressor Bearings
Piston Kit
Supply only following items all as specified and directed.
Wax (Candle Powder)
Grease (Castrol Make)
Chemical salt
PPM Testing Liquid Set
Laundrex softener chemical
Laundrex Det
Laundrex boost
Laundrex neutral
Meghana Liquid Bleach
Supply & Fixing spare parts suitable to calender Machines including taking down old unserviceable spare parts complete all as specified and directed. Make of calender machines: Supershine & Megha laundry Eqpts
Variable frequency drive
Padding cloth
Blower Motor Rewinding
Temperature Meter
Speed Regulator
Push buttons (Red, Green,Blue)
NO-Element
NC-Element
Toggle Switch
Steam Solenoid Coil 15 mm
FLR Unit
Steam inlet Braided hose pipe 1" x 2 ft
Pneumatic cylinders servicing only except spares
Wax for cleaning chest
Guide Ribbons
Painting for feeding plate
Grease for chain and gear wheel teeth
Steam trap servicing
Air line and steam line with all connectors
Lubrication oil and gear oil
Steam line Y strainer 25mm dia
Disconnecting of Motor from washing machine/ Hydro extractor/ Drying tumbler/flat bed press machine/bioler/any other equipment in laundry plant etc and material and labour for re-winding of electric motor with super enameled copper wire of good quality with same gauge and same size complete with all accessories including varnishing the winding for improvement of insulation by heating method and reassembling, installing, commissioning and testing after repair / rewinding, greasing and gland packing & necessary balancing arrangement with rubber bushes complete including transportation charges from site to work shop and back to its original position complete all as specified and directed for the following capacities:-
Up to 2 Hp
Above 2 HP to 5Hp
Above 5Hp to 10Hp
M&L descaling of the following laundry equipments with approved descaling chemicals complete all as specified and directed.
Washing machine of 100 Kg capacity
Washing machine of 50 Kg capacity
600 Kg/hr boiler
Supply & Fixing following spare parts suitable to Hydro Extractor of capacity 50Kg including taking down old unserviceable spare parts complete all as specified and directed. Make Hydro extractor :Megha laundry Eqpts
Contactor M L 1, 3 phase, 415 volts
Timer relay
Transformer
Timer
Buffer
Limit switch
Main motor bearings
Push button
Motor to body springs
Rubber bush for Hydro Extractor
Hydro Extractor motor bearings
Bridge rectifier
Diode
Body Spring support Bolts
Supply & Fixing following spare parts suitable to Air Compressor suitable for capacity up to 2HP including taking down old unserviceable spare parts complete all as specified and directed
Limit switch
Motor bearings
Compressor Bearings
Piston Kit
Drain out the fuel from the fuel tank of Boiler of capacity up to 1000ltrs and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engineer-in-charge.
S&F in MS Pipe line laid in trenchs/duct/ug/surface/wall/floor alongwith aluminium Cladding insulation including following accessories complete all as directed by Engineer-In-Charge at the Loundry Plant at Military Hospital
2 1/2" MS C Class Pipe
2 1/2" MS T/E Flanges
2 1/2" MS Long Bends
25mm C Class Pipe
25mm T/E MS Flange
1"x 6" MS long Bends
1"x 6" MS Nipples
1" Elbow
1" Steam Traps
1" MS Union
1" Axe Nipples
Bolts and Nuts suitbale to existing Pipes at Loundry plant , MH
1/2" Teflon tapes
1" globe valves
Welding Rods
Metallic Sheet
Cutting Wheels
M&L for door bedding for 50/100kg washing machines/drying tublers located MH laundry plant including taking down old unserviceable one complete all as directed by Engineer-in-Charge.
Supply, lay, connect test and commissioning of solid copper conductor cable XLPE insulated screened PVC tape innersheathed, unarmoured electric power cable heavy duty with aluminium conductor 1100 volts grade corss sectional area of 16 Sqmm single Core confirming to IS:7098 Part-I laid in trenches/floors complete testing and commissioning complete all as directed.
All as per Item No. 123 above but for 25Sqmm single core all as directed by Engineer-in-Charge
All as per Item No. 123 above but for 50Sqmm single core all as directed by Engineer-in-Charge
Supply and Lay Galvanised, medium grade, ISI Marked as pe3r IS-1239 part - I galvanized, with all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches complete all as specified and as directed of following bores : -
25mm dia bore
40mm dia bore
50mm dia bore
Supply and fixing Gun-metal glove or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of Following sizes:
25mm dia bore
40mm dia bore
50mm dia bore
S&F 2000 Ltrs capacity rotational mountain polythene water storatge water tank tripple layered as per IS-1270 - 1989 hoisted 2500 dia ball valve brass eith plythene float and fly nut and fixed in position including suitable inlet & outlet pipe ine connections & necessary platform complete including removing existing unserviceable tank complete all as directed. Make: Sintex / Polycon
Excavation in trenches in hard/dense soil not exe-1.5 mtr deep and not exe 1.5 mtr wide and getting out complete all as specified.
Returning filling in and including spreading, leveling, watering and well remaining in layer not exceeding 25 cm complete all as specified
Removal of surplus soil to a distance not exceeding 50 mtr and depositing under directed at a level not exce1.5 mtr above the starting point all as specified
Cleaning of Sewer collection chamber at E coy and FAE of MCEME by using mechanical means and cleaning the complete chamber including sludge of capacity 50000 liter complete all as specified and directed. Note:(i) Quoted rates inclusive of all arrangements required for complete cleaning of the sump and the sewage / sludge to be removed from the site and deposited to the outside Amry areas as per HMWS&SB guidelines.
Cleaning of Sewer collection chamber using mechanical means and cleaning the complete chamber including sludge of capacity 25000 liter complete all as specified and directed. Note: (i) Quoted rate is deemed to be inclusive of all arrangements required for complete cleaning of the sump and the sewage / sludge to be removed from the site and deposited to the outside Amry areas as per HMWS&SB guidelines.
Testing of water samples for bacteriological and chemical analysis as mentioned below from Pump Houses viz RCPH, GLPH, RAMC, GRPH High level , Safilguda, 36 JCO mercury, CTW, A Coy, B Coy 'C' Coy E 'Coy', HQ Coy, MH OHT, DGQA, DAD and certain other areas.complete all as specified and directed. Note: Testing of water for meter o water for Testing of water and Treated water in Each PH consider as One Job (a) Sample of Water for the above media test are to collected in transparent container/ Jar/bottle separately for each test against each pump house. ( Hyginenically clean bottles). 9b0 Sample of water to be collected shall be forwarded to Govt Lab.
Testing of Sewage Water Samples for BOD and COD testing analysis of 80 KLD STP at FAE complete all as specified and directed. (a) BOD (b) COD (a) PH Level (d) Total Suspended Soild (TSS) (e) Outlet Coliform Note: Testing of Sewage Water Treated sewage Water for total 06 STPs in three month Basis. (i.e Treated Sewage water in Each STPs consider as one Job) (a) Sample of Sewage Water for the above media test are to collected in transparent container/Jar/bottle separately for each test against each STPs. (Hygienically clean bottles). (b) Sample of water to be collected shall be forwarded to Govt Lab / any authorized Lab
Supply and replace unserviceable doors / covers of machinaries installed at mechanical laundry by using MS shhet of 2 mm thick including 2 coats of synthetic enamelled paint over a coat of redoxide primer complete all as directed. Note: Quoted rate is deemed to be inclusive of all arrangements required including bending and welding during execution
M&L for attending, repair and rectification of Boiler complaints alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- Note: Spares will be measured and paid separately
M&L for attending, repair and rectification of Washing Machine complaints alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
M&L for attending, repair and arresting leakages of steam in pipe line complaints alongwith necessary T&P, safety devices and welding as per site requirement for the following type of complaints complete all as specified and directed:-
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built ( size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for motor plinth complete all as directed
Supply and replace Trolley wheel made of Teflon with bush of wheel size 6 inch an base 4 inch complete all as specified and directed
M&L Replacement of bottom portion of existing chimney of dia 2.10 mtr by using MS pipe of 6 mm thick of approx length 2 m including necessary base plate complete all as directed. Note: (i) Contractor should visit the site before quoting to understand site condition. (ii) Quoted rate is deemed to be inclusive of necessary arrangement required for replacement of bottom portion of boiler chimney of length approx 2m including replacement of suitable dia & welding work.
supply and fix fully DOL starter without sheet metal enclousure, panel mounting type with timer, relay and contractor incl push button 2 nos for panel door mounting, of suitable rating for use at 5 HP Pump set connecting, testing complete all as directed at site.
omsai thermax engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .