Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 201 201 PLOT NO 13 PANKAJ PLAZA SECTOR 12 DWARKA NEW DELHI 09 DELHI 91 INDIA 110078 DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical 13 BANDAL CAPITAL PAUD ROAD KORTHRUD PUNE 411038 | PUNE | PUNE | MAHARASHTRA | 411038 | Rejected-Technical Uploaded_submitted documents are not as per NIT conditions |
Tender Value
Refer Docs
EMD Value
₹28,409
Closing Date
14 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer (E)HN
EE(E )HN
Modification of Fire Alarm, Fire Fighting system at T.E Building, Sec-6, Dwarka, New Delhi.
2020_MTNL_581665_1
EE(E-W)/MTNL/2020-21/18
Open Tender
Electrical Works
Works
30 days
TE Bldg. Sec-6 Dwarka, ND
As per tender document
7 documents required · 7 mandatory
₹590
MTNL Delhi
₹28,409
18 Sept 2020
4 Sept 2020
15 Sept 2020
4 Sept 2020
14 Sept 2020
4 Sept 2020
90 days
Dismantling of 15HP jockey pump, dismantling it from from the suction and delivery line, removing the coupling, removing the shaft, pump and motor from the existing base frame complete as reqd.
Servicing of 15HP jockey pump, dismantling and cleaning of empellor, refixing the empellor, refixing the pump at site, greasing the existing bearings, refixing the pump with the base frame and shaft along with coupling, making coneection with the suction and delivery line, testing etc. complete as reqd.
Dismantling of old faulty pressure switch, supplying and fixing of new pressure swith with pressure setting range 1 kg to 10 kg, making electrical connections etc. as reqd.
Servicing of existing Diesel Engine Pump KW-58, 79HP, 1500RPM ,including replacement of oil filter, air filter, replacement of engine oil, and cleaning of radiator, etc. as reqd.
Dismantling of existing Diesel Engine pump,KW-58, 79HP, 1500RPM dismantling it from from the suction and delivery line, removing the coupling , removing the shaft, pump and motor from the existing base frame complete as reqd.
Dismantling of Main Fire 75 HP Motor/ Pump and dismantling it from from the suction and delivery line, removing the coupling, removing the shaft, pump and motor from the existing base frame complete as reqd.
Servicing of Main Fire 75 HP Motor/ Pump and cleaning of empellor, refixing the empellor, refixing the pump at site, greasing the existing bearings, refixing the pump with the base frame and shaft along with coupling, making coneection with the suction and delivery line, testing etc. complete as reqd.
Dismantling of Main Sprinkler 75 HP Motor/ Pump and dismantling it from from the suction and delivery line, removing the coupling, removing the shaft, pump and motor from the existing base frame complete as reqd.
Servicing of Main Sprinkler 75 HP Motor/ Pump and cleaning of empellor, refixing the empellor, refixing the pump at site, greasing the existing bearings, refixing the pump with the base frame and shaft along with coupling, making coneection with the suction and delivery line, testing etc. complete as reqd.
S/F of pressure meter of 4'' dial in the existing pipe line suitable for pressure reading up-to 10 kg capacity including dismantling the old faulty one testing etc. as reqd.
Servicing of faulty 79HP RPM 1500 fire diesel pump, dismantling and cleaning of empellor, refixing the empellor, refixing the pump at site, greasing the existing bearings, refixing the pump with the base frame and shaft along with coupling, making coneection with the suction and delivery line, testing etc. complete as reqd.
Servicing/cleaning and greasing of existing hose reel drum/landing valves/ FB inlets to attain, proper movement and working etc. as reqd
Supply and Fixing of Shut off Nozzle for existing hose reel , proper movement and working etc. as reqd
Supply aixing of Hydrant Glass with Rubber Bidding complete as required
Supplying and fixing new 25mm dia ball valve, fxing the same along with suitable GI/MS nipple/ socket/ union/ bend including dismantling old faulty ones etc. as reqd.
Supplying and fixing of one way SS landing valve in place of old faulty one along with suitable rubber gasket, nuts and bolts i/c removing the old faulty one etc. as reqd.
Supply & Fixing of SS Fire Hose Coupling 63mm Dia ISI Marked IS 903 Complete in all respect
Servicing of sluice Valve 150mm at the Pump room . Complete as reqd.
Servicing of sluice Valve 100mm at the Pump roomTerrace. Complete as reqd.
Servicing of sluice Valve 80mm at the Pump room . Complete as reqd.
Servicing of existing sluice Valve 2000mm at the Pump room floor location. Complete as reqd.
Servicing of existing Non Return Valve 200mm at the Pump room Complete as reqd.
Servicing of existing Non Return Valve 150mm at the Pump room Complete as reqd.
Servicing of existing Non Return Valve 100mm at the Terrace Complete as reqd.
Servicing of existing Non Return Valve 80mm at the Pump Room Complete as reqd.
S/F of RRL hose pipe 63mm dia 15 mtr long with SS male and female couplings, with GI binding, ISI MARKED etc. as reqd..(Make- Life guard/Agni/OMEX/Safex)
Supplying and fixing of gun metal air release valve etc. as reqd.
S/I/T/C of Hooter made of 18 swg MS sheet with Line matcching transformer for alarm./announciation etc. as reqd.
Programming and rectification of Existing Intelligent Addressable Fire Alarm Panel (EST-3) of Edwards make along with integration with existing PA Panel complete including rectification of all loop faults along with re-numbering of each device complete as required
Supply and Fixing of Intelligent Addressable Input/Out Put Module of Edwards Make FAS System including reprogramming of the same complete as required
S/F of Intelligent Addressable Photoelectric type Smoke Detector detector Make: Edwards complete as reqd.
S/F of Intelligent Addressable ROR type Heat Detector Make: Edwards complete as reqd.
Repairing of PA Panel with integration of the same with existing Intelligent Addressable fire Alrm Panel of Edwards make. Complete as required
S/F of electronic hooter made of MS sheet with hinged cover and speaker painted in red for giving alarm in case of fire etc. as reqd.
Removing ,Cleaning of Detectors/Module, Noting the Serial number and location of the detector and then re-installing of the detector to help creat the programming data .
S/F of Glass in existing Manual call box complete as reqd.
Credit for dismantled material being contractor's property.
Operose Associates
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .