Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.0 L+₹1.6 L (3.97%)Rejected-AOC KERNI MARKET COURT ROAD UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
28 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U N 60 2021 22 Provision of Aluminium Partition with Aluminium Door Glass for Nursing Duty Station in Covid Isolation under AGE BR I OFNorth udhampur
2021_MES_487392_1
GE/U(N)-60/21-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹88,000
Yes
11 Feb 2022
10 Nov 2021
30 Dec 2021
10 Nov 2021
28 Dec 2021
14 Dec 2021
60 days
Amount
M&L for excavation in trenches in any type of soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth/laying of under ground cables and getting out in any type of soil, complete all as specified and directed by the Engr-in-charge.
M&L for surface excavation in any type of soil not exceeding 30cm deep and averaging 15cm deep and getting out,complete all as specified and directed by the Engr-in-charge.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by the Engr-in-charge.
M&L for Removing excavated material n exc. 50 m and depositing where complete all as specified and directed by the Engr-in-charge.
M&L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of Broken brick gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed by the Engr-in-charge.
M&L for 75mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring etc, complete all as specified and as directed by Engr-in-charge.
S & F of roof trusses (framed), trussed, purlins, Tubular pipe, MS plates, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including Chequered plates and plain plastes of any thickness and distance pieces, cleats etc conforming to Fe-410- W(Gde-E-250) quality- B complete all as specified and directed by the Engr-in-charge.
M&L for mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut diameter of neck 12mm not exceeding 20mm and lrngth of bolt exceeding 30cm long,complete all as specified and directed by the Engr-in-charge.
M&L for gusset/Base Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment) with riveted bolted or wlded, complete all as specified and as directed by Engr-in-Charge.
S & F mild steel framed work for ornamental and intricate design such as gate ,grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by the Engr-in-charge.
M&L for preparation of steel surfaces of any description over 10cm width or girth not other wise describe, two coat of synthetic enamel paint and over one coat of red oxide primer
M & L for ruberised precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-35 grade with Grey cement and pigment complete all as specified and directed by the Engr-in-charge.
M&L Sand filling under floors or in foundations including watering and consolidation (coushning for interlocking tiles only)complete all as specified and directed by the Engr-in-charge.
M & L for Providing precast cement concrete type C1 1:3:6 (20 mm graded aggregate) in kerbs stone, blocks etc. of any section with plane fair faces,including chamfers, weatherings, throating and necessary excavation etc. and setting jointed in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted coloured profiled Galvalume/ Zincalume sheet 0.50mm thick TCT of grading YS-550, coating class AZ-150, class-3 confirming to IS-15965-2012, pitch profile c/c n.exc 203mm & crest of profile not less than 28.5mm as in roof covering/ cladding to wall fixed with self taping screws/fastners with EPDM seals including gap filling between sheet and wall with PCC (1:3:6) as per site requirement complete all as specified and directed by Engineer-in-Charge”
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridge /cladding to wall, or on ridge fixed with self tapping screws as specified
S&F false ceiling with Everest Fibre Cement Designer tile Ivory/white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 595mmx595mm and any one of the design (occeanic , lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gms, both sides inclusive) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0..30mm thick sheet and cross T of size 15x32mm made of 0.30mm sheet spaced between main T at 600mm c/c from a grid of 600x600mm and wall angle of size 15x20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers grils, light suspended from ceiling using GI soffit cleats fixed to existing rafters, purlin etc with dash fastners GI adjustable rods of 3mm dia wit galvanised butterfly level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T-sections shall be centre black pre-painted with polyester painnt and having a load bearingcapacity of 12 kg/sqm and refixed all exesting electric wiring and fixture all complete at all heights as per directed
M&L for brick work with sub class 'B' bricks, straight or curved on plan, exceeding 6 metre mean radius built in cement mortar 1:6complete all as specified and directed by the Engr-in-charge.
Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redius built in CM 1:4 complete all as specified and as directed by Engr-in-charge.
M&L for Reinforced cement concrete (Design Mix) M-25 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified and directed by the Engr-in-charge.
M&L for Reinforced cement concrete (Design Mix) M-25 (20mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed by the Engr-in-charge.
M&L for Reinforced cement concrete (Design Mix) M-25 (20mm graded aggregate) in Roof Beam, Lintel Bend, cantilevers, bressummers complete all as specified and directed by the Engr-in-charge.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by the Engr-in-charge.
M&L for cement concrete type B2 1:2:4 (40mm graded aggregate) in surface channels and drains complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by the Engr-in-charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by the Engr-in-charge.
S&F TMT bars 10 mm dia and over at to length, bent to shape requiredm including cranking, bending including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by the Engr-in-charge.
M&L for MS TMT bars 6to 8 mm dia as in stirrups for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by the Engr-in-charge.
M&L for rendering 10 mm thick cement plaster on fair face of brick work or concrete surfaces of wall in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and directed by the Engr-in-charge.
M&L for 10 mm thick rendering CM 1:4 on fair faces of brick work or concrete surface including finished even and fair all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of oil bound distemper over one coat of primer , including 2 to 3mm thick wall care putty complete all as specified and directed by Engr-in Charge ..
M&L for providing plain cement concrete 1:3:6, type C1 using 12.5 mm graded crushed stone aggregates as in cills, steps, seismic and other similar bands, parapets and railings up to 60 cm in height, coping, kneelers, apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by the Engr-in-charge.
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed by the Engr-in-charge.
S&F 100mm long Stainless Steel Butt hinges, heavy weight, cold rolled and fixed complete all as specified and directed by the Engr-in-charge.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and complete all as specified and directed by the Engr-in-charge.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge
M&L for Reinforced cement concrete (design mix) M-25 using 20mm gradded aggregateas in:- chajjas complete all as specified and directed by the Engr-in-charge.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by the Engr-in-charge.
S & F Sheet glass, 5mm thick ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each including . at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/pane complete all as specified.
S&F 4mm thick ACP sheet of approved colour fixed to Aluminium frame with aluminium beading and EPDM rubber as per manufacturer instruction's complete all as specified.
S&F Mortice lock with two lever brass body (vertical type) 100mm length of latch with 3 set of keys fixed in door shutter with proper in position complete all as specified.
S&F Sliding Roller for sliding door (04 Nos wheels in each roller) fixed to aluminium door with screw in position complete all as specified.
S & F powder coated aluminium Deco grill DG 202 pattrn with apperture of size 60x45mm securing with suitable aluminium channel to frame complete all as specified as directed by Engr-In-Charge.
S & F Stainless steel mosquito proof wire cloth of stainless 0.36mm dia and 1.4mm aperture fixed with aluminium flat/channel and screws all as specified as directed by Engr-In-Charge.
S & F Sheet glass 5mm thick frosted / tinted ,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each including . at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/pane complete all as specified.
S&F Stainless Steel 'S' Shape Handles 300mm long Fancy type fixed with screws to door shutters complete all as specified.
S&F Aluminium Towerbolt Hinges 200mm long match with door shutters fixed to door shutters with screw complete all as specified.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge.
M&L for aluminium Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified as directed by Engr-In-Charge.
M&L for vitrified ceramic tiles coloured (double charged) of 10mm thick (square/rectangular) area of each tile exceeding 0.42 sqm but not exceeding 0.64 sqm in floors etc, set and jointed in neat cement slurry and jointed with spacers and pointed in liquid epoxy tile grout to match over and including 10mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
S& F 22mm MS dark brown powder coated curtain rod with end brackets and side brackets with designer end pieces fixed with screw and plugs as per directed complete all as specified.
M&L for rendering 15 mm thick cement plaster on fair face of brick work or concrete surfaces of wall cement mortar 1:4 and finished smooth without using extra cement complete all as specified
M&L for preparation of new plastered surfaces of wall and applying two coat of cement base paint over one coat of primer , complete all as specified and directed by Engr-in Charge ..
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by the Engr-in-charge.
M&L for green Marble 15mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types laid over cement screed bed 15mm thick in CM 1:4 including cutting and polishing all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed by the Engr-in-charge.
M&L for complete for point wiring with 1.5 Sqmm single core multistranded copper conductor FR-LSH insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLSH insulated drawn into and including concealed PVC rigid conduit 1.5mm wall thickness ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed by the Engr-in-Charge for the following:- (a) One light/fan point controlled by one, one wayswitch 5 Amp complete.
(b) One 3 pin socket outlet 5 Amp on the same board with other with.
(c) One 3 pin socket outlet 5 Amp independent.
All as per srl item No 58 above but for one 3 pin socket outlet 15 Amp independent with cable of size 4 Sqmm for point wiring and 4 Sqmm as in contineous earth wire.
S&F Switch Piano, flush type, One Way, single pole, 5 Amps, sutiable for 240V, 50Hz, AC Suuply complete all as directed by Engineer-in-Charge.
S&F Socket 5 Amps, suitable for 240V, 50Hz, AC supply complete all as directed by Engineer-in-Charge.
S&F Switch socket combination 5/ 15 Amps, suitable for 240 V, 50Hz, AC supply complete all as directed by Engineer-in-Charge
S&F Steped type, electronic fan regulator, flush type on the existing phenolic laminated sheet etc as required complete all as directed by Engineer-in-Charge
S&F Ceiling rose, 3 terminal, PVC / polycabonet, isloted body complete as directed by Engineer-in-Charge
S&F Slim linear LED lighting fixture 20 Watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 Sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as the direction of Engr-in-Charge.
Supply and fixing LED street light fitting 35W new generation energy saving & environmental friendly long life versatile pressure die-cost aluminium IP66 with acrylic with heat resistant toughened glass, corrosion resistant complete making all connection with MCB SPN alongwith MCB Box enclosura, GI tubing light grade 25mm dia length 1.2 Mtr, clamp, bolts, nuts and washers complete with testing all as specified and directed by Engineer-in-Charge.
Supply and fixing Heavy duty turobo force single phase exhaust fan 900 RPM of size 380mm sweep complete with louvre heaving aluminium/ sheet metal flap with thickness not less than 1.00 mm and mounting assembly incuding fixing exhaust fan with grouting of bolt and nuts with washer complete and making good the disturbed (white washing/ colour washing/ distembering) surfaces to match with existing specifications all as specified and as directed by Engineer-in-Charge.
Suuply and fixing ceiling fan of 1200mm sweep white in color of BEE five star rating including all electric connection and testing complete all as specified by the Engr-in-Charge.
S&F Plug and socket DBs, single pole and neutral enclosure with a two pin earth plug and socket with one single DP20 Amps, 240 Volts MCB complete all as specified and directed by the Engr-in-charge.
M&Lfor sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V including 25mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, juctiong boxes etc, as required fixed on wall alongwith on run of 6 SQAmm single corfe PVC FRLS insulated unsheathed copper conductor cable as continous earth wire and connecting to existing main switch board, distribution baord and testing on completion etc, complete all as specified and directed by the Engr-in-charge. Note : Two runs of 6 Sqmm and one run of 6 Sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
Supply and fixing sheet metal enclosure double dooor single pole and neutral 240 Volts for DV's when MCBs to be used 12 way with 200 Amp rated bus bar with IP-43 protection complete all as specified and directed by the Engr-in-charge.
Supply and fixing, connection and testing MCB SP-6-32 Amp, 'C' series, breaking capacity 10 KA of rating 32-63 Amps complete all as specified and directed by the Engr-in-charge.
Supply and fixing, connection and testing MCB SP-32-63 Amp, 240 Volts. 'C' series, breaking capacity 10 KA of rating 32-63 Amps complete all as specified and directed by the Engr-in-charge.
M&L for earthing with galvanized steel earth electrode 60cmX60Cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, GI 4.0mm dia lead wire 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and medium grade wateriang pipe 15mm bore light grade protection pipe 5 Mtr length wire wire mesh and funnel PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No 3 of SSR-2009 (Part-1)
Supply and lay XLPE insulated screened PVC beded, glavanized steel strip or wire armored, electric power cable (heavy duty) 100 Volts grade with stranded aluminium conductor of size 25 Sqmm 2 corfe in trenches/floor/ple/GI pipe complete including cutting of bituminous road/chasing to any surface and making good to the disturbed surface to match the existing complete all as specified and directed by the Engr-in-charge.
M&L for dry sand cushioning to under ground cables provided with layer of sand 8cm deep before laying the cable, 15cm depth after laying cable & stretching the cable complete all as directed by Engineer-in-Charge
Supply and lay brick class 'B' covering as mechanical protection to cable with well burnt complete all as directed by Engineer-in-Charge
M&L GI tubing light grade with all fitting and fixing in wall and floor or fixed to pole of size 40mm dia complete all as directed by Engineer-in-Charge
S & F 3mm thick plastic laminated ebonite sheet cover of size 400mmx300mm including cutting / finished or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by Engineer-in-Charge
S & F steel terminal boxes of size 400mmx300mm including cutting/ finishing or making hole etc all as specified and a directed by Engineer-in-Charge
S&F switch socket combination 5 Amps, suitable for 240V, 50Hz, AC supply complete all as directed by Engineer-in-Charge
S&F switch socket combination 15 Amps, suitable for 240V, 50Hz, AC supply complete all as directed by Engineer-in-Charge
Supply and fixing sheet metal enclosure double dooor single pole and neutral 240 Volts for DB's when MCBs to be used 2 way with 200 Amp rated bus bar with IP-43 protection complete all as directed by Engineer-in-Charge
Supply and fixing, connection and testing MCB SP-40-63 Amp, 'C' series, breaking capacity 10 KA of rating 40-63 Amps complete all as directed by Engineer-in-Charge
Supply and fix sheet metal enclosure VTPN 08 way 415 Volt 250 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection fixed in repair complete all as directed by Engr-in-Charge
S & F MCCB 4 pole, 415 Volt, Adjustable type 200 Amp with breaking capacity 25 KA complete all as directed by Engineer-in-Charge
Supply and lay XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty ) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core in trenches/floor/pole/GI pipe complete including cutting of bituminous road/ chasing to any surface and making good to the distrubed surface to match the existing complete all as directed by Engineer-in-Charge
kerni electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .